HomeMy WebLinkAboutWIND LOAD DESIGN PRESSURE CALCULATIONS`�'�%�%� ENGINE SING
0�. EXPRESS®
Order (Ref) #: 48958 (043516-3853240741)
Contractor: J&G CARPENTRY, INC.
j SCANNED
BY
St. Lucie County
Project Details: VAN HAITSMA CONDO DOOR REPLACEMENT
7030 S.W. 16TH COURT PEMBROKE
PINES, FL
5167 N. HIGHWAY AlA, UNIT 1001
FORT PIERCE, ST. LUCIE COUNTY, FL
Subject: Wind Load Design Pressure Calculations (Components & Cladding)
Site Information
Building Classification:
enclosed
Wind Speed (V It):
170 mph
Exposure Category:
d
Roof Type:
monoslope
Roof Slope (0):
1.2 deg
Mean Roof Height (h):
97.0 ft
Min. Building Dimension (L):
71.0 ft
Parapet —: 3 feet?
No
General Calculation
Directionality Factor (Kd):
0.85
Gust -Effect Factor (G):
0.85
Internal Pressure
Coefficient (GCpf )•
±0.18
Topographical Factor (K,t):
1.0
Velocity Pressure Exposure
Coefficient ( nK):
1.43
Velocity Pressure (qh):
89.64 psf
End Zone (a):
7.1 ft
ASD Method:
P = 0.6w
NOTES: Design is in accordance with ASCE 7-10 (ASD method) and the Florida Building Code Sixth Edition (2017). Results
are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering Express. Valid Only With
Results are based on contractor -supplied data and shall be field verified by others priorto use. Selection & installation of
products shall be approved using these dimensions and. pressures as verified by others. \��
LIGENs
Note: For openings to be properly rated in Zone 4, no part of the opening shall be within 7.1 feet of any building coZn�7',(�� Wed, Febru
This engineer has not field visited this location and if this cannot be clearly identified by others, the opening shall_4e re=
evaluated prior to installation of any fenestration. All other information provided above including mean roof heighhett.. ..:
building minimum dimensions, opening sizes, & other supporting data was provided by others. For definitions othL
above terms, visit EngineeringExpress.com/Wiki " —
�O
ised Engineer
STATE OF
"40RIOP.•'•
. RIVAL ENG\\
160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA 33442
48958 (043516-3853240741) PHONE: (954) 354-0660 — FAX: (954) 354-0443
AutoPrint ENGINEERINGEXPRESS.COM
PAGE 1 OF 1