Loading...
HomeMy WebLinkAboutDOOR REPLACEMENT PLANST. LUCIE COUNTY BUILDING OIVIS REVIEWE FOR COMP" REVIEWED DATE NS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE MESE PLAINS AND ALL PROPOSED SR/Ol: ARE SUBJECT TO ANY CORRECTICHS REQUIRED BY FIELD INSPECTORS TH MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD 36' X 80" REPLACE DOOR IN 1 OPENING ONLY. NEW DOOR TO BE IMPACT RESISTANT - HURRICANE SHUTTERS NOT REQUIRED. SCANNED BY St. Lucie County RFc 06 10 011 r'�''9 1QJB C4�7POPpd OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A. #) POS. NEG. 1 36 80 20.00 4 57.8 1 -58.1 FL15210.1 1 75.0 1 -75.0 1 FRONT ENTRY - LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 96 FT 4 IN LAGRAND CONDO UNIT 5167 N. HIGHWAY A1A, UNIT 1104 FORT PIERCE, FLORIDA DOOR REPLACEMENT PLAN