Loading...
HomeMy WebLinkAboutWIND LOAD DESIGN PRESSURE CALCULATIONS�-/ ENGINE=._RING EXPRESS SCANNED BY St. Lucie Countv Order (Ref) #: 48958 (043516-3838888889) Project Details: O'CONNOR CONDO DOOR REPLACEMENT Contractor: AG CARPENTRY, INC. 5167 N. HIGHWAY AlA, UNIT 804 7030 S.W. 16TH COURT PEMBROKE FORT PIERCE, ST. LUCIE COUNTY, FL PINES, FL Subject: Wind Load Design Pressure Calculations (Components & Cladding) Site Information Building Classification: enclosed Wind Speed (V It): 170 mph Exposure Category: d Roof Type: monoslope Roof Slope (0): 1.2 deg Mean Roof Height (h): 97.0 ft Min. Building Dimension (L): 71.0 ft Parapet >: 3 feet? No General Calculation Directionality Factor (Kd): 0.85 Gust -Effect Factor (G): 0.85 Internal Pressure Coefficient (GCpi . )• ±0.18 Topographical Factor (Kt): 1.0 Velocity Pressure Exposure Coefficient ( nK): 1.43 Velocity Pressure (qh): 89.64 psf End Zone (a): 7.1 ft ASD Method: P = 0.6w ®� r :r r �m r r � :� � •� r •r NOTES: Design is in accordance with ASCE 7-10 (ASO method) and the Florida Building Code Sixth Edition (2017). Results are not valid for use unless approved via original signature and raised engineer seal of a FIE from Engineering Express. \\ Results are based on contractor -supplied data and shall befield verified by others priorto use. Selection & installatio,) off products shall be approved using these dimensions and pressures as verified by others. � Q Note: For openings to be properly rated In Zone 4, no part of the opening shall be within 7.1 feet of anybuild This engineer has not field visited this location and if this cannot be clearly identified by others, the openings evaluated priorto installation of any fenestration. All other information provided above including mean roof building minimum dimensions, opening sizes, & other supporting data was provided by others. For definition above terms, visit EngineeringExpress.com/Wiki " O; gcoPe.. DI be ri- i � i afid orY,9[th fed Engineer Nt ��OENSF' O� Gordan STATE 09'8,85 r.s.0 fiL.. /�frlllNl lit t\\ 160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA 33442 48958 (043516-3838888889) PHONE: (954) 354-0660 — FAX: (954) 354-0443 AutoPrint ENGINEERINGEXPRESS.COM PAGE 1 OF 1