Loading...
HomeMy WebLinkAboutARCHITECT SUPPLEMENTAL INSTRUCTIONSM 4) VISAIA Document G710'0 —1992 Architect's Supplemental Instructions PROJECT (Name and address): ARCHITECT'S SUPPLEMENTAL Surgery Center of St Lucie County INSTRUCTION NO: 001 6830 US Highway 1 Port St Lucie, Florida OWNER (Name and address): Surgical Specialties of St. Lucie County,LLC 4632 South 25"i Street Fort Pierce, Florida 34981 FROM ARCHITECT (Name and address): Gordon & Associates, Architects 3797 Lake Center Drive Mount Dora, Florida 32757 TO CONTRACTOR'(Name and address): J. McLauchlin & Company 3019 Southwest 27" Avenue Ocala, Florida 34474 DATE OF ISSUANCE: November 3, 2010 CONTRACT FOR: General Construction CONTRACT DATE: ARCHITECT'S PROJECT NUMBER: 0801-DB OWNER: ARCHITECT: CONSULTANT: CONTRACTOR: FIELD: OTHER: The Work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these instructions indicates your acknowledgment that there will be no change in the Contract Sum or Contract Time. DESCRIPTION: Incorporate the following minor modifications and clarifications as required by the St Lucie County Building Department I- Life Safety Plan, Drawing A3.3 has been modified to be titled the LIFE SAFETY AND ACCESSIBILITY PLAN, to indicate the accessible rout from accessible parking into the building and to the business counter. 2- Specifications Section 08410 has been modified to change to Florida Product Approval Numbers for exterior storefront and fixed windows, to reflect recent changes in Florida's Web Site and adoption of the product approval data, which occurred subsequent to the release of the Construction Documents. 3- Drawings Aj A5.2 and A81, and Specifications Section 07460 have been modified to change to Florida Product Approval Number for exterior Hardi Products siding, to reflect recent changes in Florida's Web Site and adoption of the product approval data, which occurred subsequent to the release of the Construction Documents. 4- Specifications Section 07610 has been modified to change to Florida Product Approval Number for roof covering material, to reflect recent changes in Florida's Web Site and adoption of the product approval data, which occurred subsequent to the release of the Construction Documents. AIA Document G710--1992. Copyright® 1979 and 1992 by The American Institute of Architects. All rights reserved. WARNING: This AIA Document Is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or dlstribunon of this Ale Document, or any portion of it, may result In severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was produced by AIA software at 11:22:49 on 11/03/2010 under Order No. 1152557710 1 which expires on 05/04/2011, and is not for resale. User Notes: (1934847087) .a w 5- Site Plan Drawing A1.1 has been modified to add reference to the loading zone to match the Civil Engineering Drawing, and to add exterior pouch and covered drive -through square footages to the Drawing. These areas do not increase the occupied space, change the occupancy, or alter the life safety requirements of the building, but have been added at the request of the authority having jurisdiction. 6- Life Safety and Accessibility Plan A3.3 has been modified to add exterior pouch and covered drivc-through square footages to the Drawing. These areas do not increase the occupied space, change the occupancy, or alter the life safety requirements of the building, but have been added at the request of the authority having jurisdiction. ATTACHMENTS: (Here insert listing of documents that support description.) Drawing A 1.1 - Site Plan, revised November 3, 2010 Drawing A3.3 Life Satety and Accessibility Plan, revised November 3, 2010 Drawing A511 Wall Sections, revised November 3, 2010 Drawing A52 - Wall Sections, revised November 3, 2010 Drawing A8.1 - Details, revised November 3, 2010 Specifications Section 07460 - Cememtitious Siding, revised November 3, 2010 Specifications Section 07610 - Metal Roofing, revised November 3, 2010 Specifications Section 08410 - Storefront and Aluminum Entrances, revised November 3, 2010 ARCHITECT: Michael Lee Gordon, A.I.A. Gordon & Associates, Architects (Printed name and title) AIA Document G710--1992. Copyright® 1979 and 1992 by The American Institute of Architects. All rights reserved. WARNING: This AIA' Document Is protected by U.S. Copyright Law and International Trestles. Unauthorized reproduction or distribution of this AIA° Document, or any portion of It, may 2 result in severe civil and criminal penaltles, and will be prosecuted to the maximum extent possible under the law. This document was produced by AIA software at 11:22:49 on 11/03/2010 under Order No. 1152557710 1 which expires on 0510412011, and Is not for resale. User Notes: (1934847087) I. Nurses call system equipment. J. Code Blue system equipment. K. Television antennae system equipment. L. Dictation system equipment. M. Intercommunication and sound paging system equipment. N. Telephone system equipment. O. Patient monitoring equipment. P. Medical Imaging and Processing equipment. 1.3 QUALITY ASSURANCE A. Comply with applicable local, state and federal codes. B. Comply with applicable requirements of recognized industry associations which promulgate standards for the various trades. C. Employ only qualified journeymen for this work. Employ a competent qualified electrician to supervise the work 1.4 STANDARDS A. Perform work specified in Division 16 in accordance with standards listed below including amendments or revisions. When these specifications are more stringent, they take precedence. In case of conflict, obtain a decision from the Designer. B. National Fire Codes (NFPA) including, but not limited to following: 1. NFPA-70 - National Electrical Code. 2008 Edition. 2. NFPA-72 - National Fire Alarm Code. 2002 Edition. 3. NFPA-99 - Health Care Facilities. 2005 Edition. 4. NFPA-101 - Life Safety Code. 2006 Edition. 5. NFPA-110 -Power Systems, Emergency and Standby. 2002 Edition. 6. NFPA-780 - Lightning Protection Code. 2004 Edition. C. Applicable Codes: 1. 2. 3. 4. ANSI-A17.1: Elevators, Dumbwaiters, Escalators and moving walks. Florida Building Code 2007 Edition with 2009 supplements. State of Florida Administrative Code No. 59A-5, July 1997 Edition. AIA Guidelines for Design and Construction of Health Care Facilities, 2006 Edition. D. Should any work be construed as being contrary to or not conforming to aforementioned codes, such alleged confliction to be brought to attention of Engineer in writing ten (10) days prior to bid date for review so that such point in question may be resolved. All work to be installed in strict conformity with applicable codes without additional cost to Owner. ICT PROM 208179 GENERAL PROVISIONS 16010 - 2