HomeMy WebLinkAboutINPUT DATA REPORTr SCANNED _ EnergyGauge Summit® v3.20 BY St. Lucie County INPUT DATA REPORT Pro.'ect Information Project Name: ST LUCIE SURGERY Orientation: North Project Title: SURGERY CENTER OF ST LUCIE Building Type: Healthcare -Clinic Address: SECTION 15, TOWNSHIP 36S, RANGE 40E Building Classification: New Finished building State: Fl, No.ofStories: I Zip: 0 GrossArea: 9047 SF Owner: Zones No Acronym Description Type Area [sf] Multiplier Total Area ]sfj 1 PrOZol SURGERY CONDITIONED 9047.0 I 9047.0 ❑ Spaces No Acronym Description Type Depth IN Width Height Multi [ft] ]ft] plier Total Area lsf] Total Volume lcf] 2/25/2010 EnergyGauge Summit® v3.20 1 In Zone: PrOZal 1 PrOZo1Sp1 SURGERY. Exam/Treatment (Hospital) 100.00 90.47 10.00 1 9047.0 90470.0 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Recessed Fluorescent - General Lighting 41 128 5248 Occupancy Sensor with 1 El No vent Timer without Daylighting 2 Recessed Fluorescent - General Lighting 23 64 1472 Occupancy sensor without 1 No vent Daylighting 3 Recessed Fluorescent - Lighting for medical 24 192 4608 Occupancy sensor with 1 No vent procedures/equipment Daylighting On/Off 4 Recessed Fluorescent - General Lighting 39 40 1560 Occupancy Sensor with 1 No vent Timer without Daylighting 5 Compact Fluorescent General Lighting 14 100 1400 Occupancy Sensor with 1 ❑ . Timer with Daylighting 4 step 6 Compact Fluorescent General Lighting 8 26 208 Occupancy sensor without 1 El . Daylighting 7 Compact Fluorescent General Lighting 9 26 234 Occupancy sensor with 1 El Daylighting On/Off 8 Compact Fluorescent General Lighting 14 25 350 Occupancy sensor with 1 El Daylighting On/Off 9 Compact Fluorescent General Lighting 15 100 1500 Occupancy sensor with 1 El Daylighting On/Off 10 Compact Fluorescent General Lighting 2 13 26 Occupancy sensor with 1 El Daylighting On/Off 11 Compact Fluorescent Exit Sign 14 10 140 Occupancy sensor with I El Daylighting On/Off 2/25/2010 EnergyGauge Summit® v3.20 Y f • 4 � Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [all [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtul [Btu/sSF] In Zone: PrOZol 1 PrOZolWal 5/8" stucco 100.00 10.00 1 1000.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"I80 BTWN24"oc/.5" Gyp 2 PrOZolWal 8"CMU/3/4"ISO 100.00 10.00 1 1000.0 South 0.2642 9.696 62.72 3.8 ❑ BTWN24"oc/5/8 Gyp 3 PrOZolWal 518"stucco 90.47 10.00 1 904.7 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 PrOZolWal 5/8"stucco 90.47 10.00 1 904.7 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (ERec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: Pr0Zo1 In Wall: EAST 1 PrOZolWalWil User Defined No 0.9000 0.68 0.66 8.00 4.00 1 32.0 In Wall: NORTH 1 PrOZolWalWil User Defined No 0.9000 0.68 0.66 4.00 4.00 7 112.0 In Wall: WEST 1 PrOZolWalWil User Defined No 0.9000 0.68 0.66 4.00 4.00 2 32.0 El 2 PCOZolWalWi2 User Defined No 0.9000 0.68 0.66 8.00 4.00 1 32.0 El 2/25/2010 EnergyGauge Summit® v3.20 3 i Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [it] lit] plier [sf] [Btu/hr. sE F] ]Ib/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: PrOZol In Wall: NORTH I PrOZolWalDrl Aluminum door, No 3.00 7.00 1 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: EAST 1 PrOZolWalDrl Aluminum door, No 3.00 7.00 8 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In all: WEST I PrOZolWalDrl Aluminum door, No 3.00 7.00 3 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene Roofs No Description Type Width H (Elfec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [it] [ft] plier [sf] [deg] [Btu/hr. St. F] [Btu/sE F] [[b/cf] [h.sf.FBtu] In Zone: Pr0Zo1 1 Pr0Zo1Rf1 Slmgl/l/2"WD 90.47 100.00 1 9047.0 0.00 0.0320 1.50 8.22 31.2 ❑ Deck/WD Truss/9" Batt/Gyp Brd Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] In Zone: In Roori. 2/25/2010 EnergyGauge Summit® v3.20 { Floors No Description Type Width [ft] H (Effec) Multi [ft] plier Area Cond. Heat Cap. Dens. 77alue [sf] [Btu/hr. sE F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol I Pr0Zo1F11 Concrete floor, 90.47 carpet and rubber pad 100.00 1 9047.0 0.5987 9.33 140.00 1.67 ❑ Systems AHU-1 System 1 Constant Volume Packaged System No. Of Units 1 • Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 4 Air Distribution System 482000.00 239008.00 7900.00 13.00 11.00 1.00 0.82 6.00 ❑ ❑ ❑ ❑ AHU-2 System 2 Constant Volume Packaged System No. Of Units 1 • Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 4 Air Distribution System 286000.00 187792.00 6400.00 13.00 11.00 1.00 0.82 6.00 ❑ ❑ ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV 2/25/2010 EnergyGauge Summit® v3.20 Water Heaters W-Heater Description CapacitlCap.Uuit UP Rt. Efficiency Loss 1 Electric water heater 50 [Gal] 9 [kW] 0.9200 [Ef] [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf%ft/No] Control Type Wattage [W] 1 Ext Light 1 Other (doors) than main 4 26 entries 6.00 Photo Sensor control 104.00 ❑ Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonalpipe Diameter [in] Insulation Thickness [in] IsRunout? 1 Domestic and Service Hot Water Systems 105.00 0.28 1.00 1.00 No ❑ Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/b.sf.F] ASHULDbIC1rM User Defined 2 0.9000 0.6800 0.6600 ❑ tl-Oth frm 2/25/2010 EnergyGauge Summit® v3.20 Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sLF/Btu] [ft] [Btu/h.ft.F] [lb/ct] [Btu/Ib.F] 264 a o4SO.UO 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/41N, 187 Mat(187 GYP ORPLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 151 Mat1151 CONC HW, ORD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 4IN 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 105 MatII05 CONC BLK HW, 81N, No 1.1002 0.6667 ' 0.6060 69.00 0.2000 ❑ HOLLOW 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mati42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Ma11244 PLYWOOD, 1/2IN No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sLF] [lb/cf] [h.sf.FBtu] 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 0.53 43.67 5.2 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 264 ALUMINUM, 1/16IN 0.0050 0.000 ❑ 2 214 POLYSTYRENE, EXP., 1-1/4IN, 0.1042 0.000 ❑ 3 264 ALUMINUM, 1/16IN 0.0050 0.000 ❑ 2/25/2010 EnergyGauge Summit® v3.20 No Name Simple Construct Massless Conductance _ Heat Capacity Construct [Btu/h.sf.F] [Btu/sGF] Density [lb/cf] RValue [h.sf.FBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.7 ❑ Layer Material Material Thickness Framing No. [it] Factor 1 151 CONC HW, DRD, 140LB, 4IN 0.3333 0.000 ❑ 2 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sUl [Btu/sLF] Density [lb/ci] RValue [h.sCF/Btu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. IN Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP ORPLAS BOARD,112IN 0.0417 0.000 ❑ No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/II.SEF] [Btu/sEF] Density [Ib/cf] RValue Ih.sf.F/Btu] 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.8 ❑ Layer Material Material Thickness Framing No. Ift] Factor 1 105 CONC BLK HW, 81N, HOLLOW 0.6667 0.000 ❑ 2 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 3 187 GYP OR PLAS BOARD, 1/21N 0.0417 0.000 ❑ 2/25/2010 EnergyGauge Summit® v3.20 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sGF] [Btu/sGF] [Ib/ct] [h.st:FBtu] 1038 ShngUl/2"WD Deck/WD Tmss/9" BatUGyp No No 0.03 1.50 8.22 31.2 ❑ Brd Layer Material Material Thickness Framing No. [it] Factor 1 81 ASPHALT -ROOFING, ROLL 0.000 ❑ 2 244 PLYWOOD, 1/21N 0.0417 0.000 ❑ 3 12 3 in. Insulation 0.2500 0.000 ❑ 4 23 6 in. Insulation 0.5000 0.000 ❑ 5 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 2/25/2010 EnergyGauge Summit® v3.20 9