HomeMy WebLinkAboutPLAN REVIEW FROM99fD ��v`�X
SAINT LUCIE COUNTY FIRE DISTRICT
PLAN REVIEW FORM
5160 N.W. Milner Drive
Port Saint Lucie, FL 34983
Telephone: 772-621-3322
Fax: 772-621-3604
Web Address: www.slcfd.com
SCANNED
By
St. Lucie County
Building Dept.
Saint Lucie County
FMOPermit# B-11-05
Project Name
The Surgery Center of Saint Lucie County _
_— BLDG Permit 10092139
Address
68305outh 15 Highwayl
city Port Saint Lucie
Contractor
Address
State
J. McLaunchlin &Company
3019 SW 27th Avenue, Suite 102 _ I city Ocala
Florida Zip 34471 III Telephone 352.873.3900
Architect/Engineer Gordon&Associates Telephone 352.383.6505
Occupancy Type Ambulatory Health Care/Business Construction Type VB —� St uare Feet 9138
Occupant Load 92perplan Numberof Stories h Access Box Required Access Key Switch
AFS Permit Required FA Permit Required FIT, Permit
General Notes
1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be.pdf only.
2. All revisions, Including the electronic copy must be received prior to permitting.
3. The Fire Marshal requires 24 hour notice on all Inspections.
4. The respective Building Department shall schedule all final Inspections through the Fire Marshal's Office.
S. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans.
7. Fire alarm panels shall be located Indoors within air conditioned space.
B. Plans and construction are subject to corrections in the field to maintain code compliance.
9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity.
THE FLORIDA FIRE PREVENTION CODE, 2007 EDITION IS CURRENTLY ENFORCED.
BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVr:D FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY.
Required Revisions
The project manual, In some locations, indicates the 2003 Life Safety Code edition, however the 2007 Florida Fire Prevention
.ode references the Florida Modified 2006 Life Safety Code. In addition, the Fire protection section refers to the Englewood Fire
Aarshal jurisdiction.
A separate review and permit is required for the installation of fire sprinkler, fire alarm, and emergency standby generator.
i. Provide a remote test and inspect appliance equipped with an audible/visual indicator for the HVAC duct -smoke detectors.
Paged of n Reviewed by T_Liento __ _ _ ___ J Date 1-5-2011