Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSN i7 BUILDING PLAN CHECK ST. LUCIE COUNTY -FORT PIERCE. FIRE PREVENTION BUREAU FORT PIERCE, FLORIDA TELEPHONE 465-6655 JURISDICTION:' St. Lucie County PLAN NUMBER 6041 PROJECT NAME: MIKE CLANCEY CONSTRUCTION OFFICEBUILDING DEPT. NO. 90-1461 , CONTRACTOR: Mike Clancey ARCHITECT: OWNER: Griggs Industrial Park LOCATION: 10225 Lennard Rd. BUILDING SIZE: 1 -000 sq. ft. OCCUPANCY TYPE: Sr" aga CONSTRUCTION TYPE: SBCCI. IV un NFPA. II (000) PHONE NUMBER 335-2660 PHONE NUMBER DATE RECEIVED 6-19-90 NUMBER OF STORIES I BUILDING HEIGHT. FIRE PROTECTION: Automatic Sprinkler Yes No X Occupancy Hazard N.F.P.A. #13 Requirements: SCANNED BY St. Lucie County 1. Provide approved exit lights above rear storage area exit door and the storage exit door into the office area. 2. Provide a'4A-20BC rated fire extingusiher. Mount inside storage area just inside the office exit door. The light shall have a 90 minute battery back-up. 3. Provide an approved emergency light. Mount as marked on plan. 4. Walls separating occupancies of the same group shall be constructed of materials having a fire resistant rating of one (1) hour except that in Group "B" Business and Group "S" Storage buildings. Non -rated partitions may be used to separate tenants provided no area between partitions rated one hour or more exceeds 3,000 square feet. Partitions shall extend from the floor to tight against the underside of the roof deck and shall extend outward to include the eave line. A two (2) hour rated wall will be required between this storage tenant and the factory industrial occupancy (Frank's Auto Care). CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS 24 HOUR NOTICE REQUIRED ON ALL INSPECTIONS REVIEWED BY: !� T!� �E-/ ,;,�.• DATE II_-..i_ 1 - CBTuCK UiT PRO 90-1461 Project'Name: Architect: GRIGGS INDUSTRIAL PARK - INTERIOR IMPROVEMENTS (PHASE II-BLDG. B) Ph: Contractor: MIKE CLANCY CONST. GENERAL CONTR. Ph: 335-2660 (RICHARD) Owner: CHARLES GRIGGS JR. Ph: Address: 10225 SE. LENNARD RD. PORT ST. LUCIE, FL 34952 occupancy Classification: Type of Construction: Height and Area: occupancy Requirements per Chapter IV: Construction Requirements: A. Fire Protection: S � � Y B. Egress Requirements: other Requirements: r Elevators • Sprinklers 6 Standpipes �— Combustible Materials - Interior ✓ Roof Coverings Light - Ventilation - Sanitation Handicap Requirements Plana sent to Fire Dept. - Date: 6-18 Plot Plan Check Water Serer Energy Code Paving 3 Drainage approval by Engineering Dept. Special Conditions prior to issuance Threaholq•.Affidavit/Before Issuance Affidavit Z " Approved: LM 11111D � \ > FIRERESISTANCE RATED STEEL STUD DRYWALL PARTITIONS I�oregaP and C sum board ev i A(; f � 1 � , N - 1 r h- •' f� \ 4i L'P h'JI.rW C 4.MPi "n F::d NN , - r l �6regward gypsum board 1 V S 4t p' ' if ::l I 1 + ti 1 tt +; ��,' + •, t Refer to Drywall Sound Resistance ''•^ Rated Construction notes on \t� " back page, ,BA SIC ASSEMBLY STC' 119 STC i (Authority (Authority + DRC'70-151)�-DRD'71-21)15u+ n '.'23/< INSUL'•r' UL DESIGN, U412 F'UL ®ESIGItI'U4181 n'su Ji.. • Partition thickness: 41A" -! 1 Partition thickness:41/2"' STC ;.? e' �N O F=- r 3 I STC' (Authority DRC' 76 40)., r3, to to INSUL )L ®c`b'- IGH U412' UL. DESIGN, U412. nsul; Phrtition thickness 5% ` '+ Partition thickness '55/e RS J. ASIC AS3E'MBLY STC( STC thony (Estimated)!' GA WP7540 50�tzmV ❑ 1.+ 1 1• � V UL ®e ➢ign ,U4111 •'Partitionthickness:5" STC ! r. (Estimated) Y' Eslimatetl ❑ 1. r �r 1 UL'Deidg�a„19 11', �Partition'thicknem 61/e" o n '1 23/ INSUL N xl ZI Based On UL %4�artition thickness: 5" GA ,utl6a8J � � t � � N \ r I - 2.112 INSUL, -UU Based on UL. U411 y'shl • Partition thickness: 61/e"; 11