HomeMy WebLinkAboutSUBMITTED PAPERSa `®
ST. I..UCIE COUNTY PERMIT•APPI&ICATIO./
[ I° IT NO. \ CODE �f SESIAGE PERMIT NO. A3
APPLICATION FOR PEP�T TO CONSTRUC:T� �orveme ` CtCBbi�
JOB LOCATION/ADDRESS _10249 Lennard Road Port St. Lucie, FL 34952
L,SGAL DESCRIPTION' s
VX
PERTY TAX ID --
i ,
PLAN -NAMgo�y(�t, ft `# -- FLOOD ZONE N�%� RLRV
S/D
E0 �/� / Trp 37S
-OT
SIZE/E
SST BACKS:
_ LOT ALK
RGII(k ce- ZONRi y �,
/ FRONT /J /R- RSAR_ ^ BIDS !���G S..IDE Zl-)Iq._
/ EST COST�B 000.00B—P V1�LGR F_ PADON
/s0 FT BUILDINGS: LIVING AREA ACCESSOR� 9/07�
ARCHITECT: NAME Gary Kelly FROM 283.3492
ST 118 W. 6sth Street CTY Stuart ST FL ZIP 3499/4;_
CONTRACTOR: STATE R�/CBRT q d CGC 022955 CITY CERT 0 027
NAME Don Campora Const. Co. Inc. PHONE 283-4761
6335- GAi Ave. CTY Stuart ST FL ZIP`34997
OWNER OF old DBA
PROPr�ERTYF rical
ConLracting PHON$ 39 -9 9
ZSTEeOr
Box 7096 (ort St.,LucieST FL ZIP 34985 FLORIDA,. COUNTY OF ZT. LUCIE''nn
&dspozes
Before me, the undersi ned authorlt
4 y, penally
appeared, Douglas Campora who .upon being duly sworn,
an'd gaye that the nfo oration con(tai d in the forcagoing
ff\�� application !e true and car act ,• ���--,�.,�at
SwaFn to
and su scribed betore
me this
�[��
day of
-G
-19a
SCHOOL IMPACT ROAD
IMPACT
Notary Public,
State Of FL at Lamle
Req yrsKno
Req
ve,sXno
MY :oruniss.Lon expires
Amt Pd
Dist
1Jofdiy PUHC;-S1dr2 of Flbrih --
-- - ------
Date Pci
Zone—
My Commi,:ioa Expires ScPL 18, 1991
---
- -
6omdcd rhri'. is n -in. ,. , Inc.
Fr n
PRO 90-0261
Project Name:
Architect:
Contractor:
Owner:
Address:
BAY�E-1Z
GRIGGS INDUSTRIAL PARK - INTERIOR IMPROVEMENTS (SOUTH STAR ELECTRICAL)
GARY KELLY
Ph: 283-3492
DON CAMPORA CONST. CO., INC. ph_ 283-4761
CHARLES E. GRIGGS
Ph: 335-9393 (S. STAR)
10219 LENNARD RD. PORT ST. LUCIE, FL 34952
Occupancy Classification:
S
Type of Construction:
Height and Area:
Occupancy Requirements per Chapter IV: t G P17 )7 c717 J ��
Construction Requirements:
A. Fire Protection:
d /
B. Egress Requirements: '�,�\
Other JRequirements:
f /u-
/Y
eSK
U�
s tl
Elevators
Sprinklers-& Standpipes
Combustible Materials - Interior
Roof Coverings
Light - Ventilation - Sanitation
Handicap Requirements
Plana sent to Fire Dept. - Date: 02 -A?P �0 Approved:
Plot Plan Check
dater
Energy Code
Sever
Paving & Drainage approval by Engineering Dept.
Special Conditions prior to issuance
Threshold Affidavit/Before Issuance Affidavit
y
BUILDING PLAN CHE
ST. LUCIE COUNTY -FORT PIERCE FIRE PREVENTION BUREAU
FORT PIERCE, FLORIDA
TELEPHONE 465-6655
JURISDICTION: St. Lucie County
PROJECT NAME: SOTITH STAR RLECTRTCAT,
CONTRACTOR: Don Campora Construction
ARCHITECT: Gary Kelly
OWNER: Charles Griggs
LOCATION: 10219 Lennard Rd.
BUILDING SIZE: 1,000 sq. ft.
OCCUPANCY TYPE: Storage/Business
CONSTRUCTION TYPE: SBCCI.
1►127•t
FIRE PROTECTION: Automatic Sprinkler Yes— No
Occupancy Hazard N.F.P.A. #13
Requirements:
1. Stairs shall comply with NFPA 101, 5-2.2
Maximum height of risers 7".
Minimum height of risers 4".
Minimum tread depth 11".
Minimum head room 6' 8".
PLAN NUMBER #1993
BUILDING DEPT. NO. 90-0261
PHONE NUMBER 283-4761
PHONE NUMBER 283-3492
DATE RECEIVED 335-9393
NUMBER OF STORIES 2
BUILDING HEIGHT
2. 2A-IOBC rated portable fire extinguishers every 75' of travel distance.
REVIEWED BY
CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS
24 HOUR NOTICE REOUIRED ON ALL INSPECTIONS
DATE—��
Sheet No. — of —
P.O. BOX 7096
PORT ST. LUCIE, FLORIDA 34985-7096
(407) 335-9393
LOAD CALCULATION
South Star Electrical Contracting - Tenant Space
GENERAL LIGHTING LOAD
1000 sq. ft. @ 3.5 per sq. ft. 3367 x 1.25 = 4375
RECEPTACLE LOAD
27 outlets @ 180 SCANNED 4860 @ 100% = 4860
BY
FUTURE SIGN OUTLET St. Lucie County 1500
REFRIGERATOR 980
TOTAL GENERAL LIGHTING LOAD 11,715
FIXTED DQUIPMENT
A/C / HEAT 5,000
TOTAL CONNECTED LOAD 16,715
16,715 . 230 = 72.67 Amps