Loading...
HomeMy WebLinkAboutDESIGN CERTIFICATION FOR WIND LOAD COMPLIANCESt. Lucie County SCANNED BY St. Lucie County Building and Zoning Department 2300 Virginia Avenue FILE Fort Pierce, FL 34982 C 0 772-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls,,columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. Project Name MORNINGSIDE Office Use Only Street Ad ress i Permit Number �VJU61 i Occupancy pe LOT BX Construction Type Certification Statement: 1 certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. 1 also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the a propriate box.) 1. Florida Building Code 2004 Edition ASCE 7-98 V 2. Building Design is (check one) Enclosed No/ Partially Enclosed Open Building 3. Building Height: 24 t _41, 4. Wind Speed Used in Building Design: 130 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line 111): B 6. Average Wind Velocity Pressure on Exterior Faces of Structure 25.74 PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure NSA PSF 8. Importance/Use Factor (obtain from Building Code): 1.0 9.Loads: Floor__55__PSF Roof/dead 25 PSF Roof/live in PSF 10. Were Shear Walls Considered for Structure (check one): Yes ✓ No if No, attach explanation) 11. Is a Continuous Load Path Provided (check one): Yes ✓ No I(if No, attach explanation) 12. Are Component and Cladding Detail Provided (check one): Yes )V/ No _(if No, attach explanation) 13. Minimum Soil Bearing Pressure: 2,500 PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: SCOTT R. BRENNAN Design Firm: BRENNAN ENGINEERING, INC Certification 4: 51311 [Seal Here] Date: 9- a-3 "0 / 0� SLCCDV Form H 020-00 rev. IVPJ5 g