Loading...
HomeMy WebLinkAboutFLORIDA ENERGY EFFECIENCY CODEFARM 60OA-2004R EnergyGauge® 4.5 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: CNETX MOORNINGSIDE 1851 Builder: CENTEX HOMES Address: Lot: D2 Q.S Sub: MOORNINGSIDE, Plat: Permitting Office: City, State: ST LUCIE COUNTY, FL Permit Number: Owner: CUSTOM Jurisdiction Number: Climate Zone: Central I. New construction or existing New _ 2. Single family or multi -family Single family 3. Number of units, if multi -family I _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? yes _ 6. Conditioned floor area (W) 1851112 _ 7. Glass type I and area: (Label regd. by 13-104A.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 166.0 ft' - b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 166.0 W - 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 182.0(p) ft - b. N/A c. N/A 9. Wall types a. Concrete, Int htsul, Exterior R=4.1, 2273.0 ftrb. _ c. N/A Frame, Wood, AdiacengCANNED R=11.0, 306.0 ft' d. N/A' $t. t U�BY e. N/A County - 10. Ceiling types _ a. Under Attic R=19.0, 1851.0 ft' b. N& _ e. N/A _ 11. Ducts _ a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems Cap: 41.5 kBtu/lw - SEER: 13.00 a. Electric Heat Pump Cap: 15.5 kBtu/hr HSPF: 8.50 _ b. N/A LEffo C 0 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.92 _ b. N/A a Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits PT, - (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZGMultizone cooling, MZH-Multizone heating) Glass/Floor Area: 0.09 Total as -built points: 22151 Total base points: 24336 PASS I hereby certify that a an and spec' s covered by this calculation are i mpiianneyri the Flori n rg Code. PREPARED BY DATE: - -C7 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. )WNERJ,AGEN . DATE: � 71 Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant class tune. For actual nh.sq tvnn anA araac �aP s� �mn,o� Glace nitnnf nn nanoe EnergyGauge® (Version: FLRCSB v4.5) FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: . Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang II.Single, Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1851.0 24.35 8113.0 Clear S 1.0 4.0 6.0 48.22 0.87 251.0 2.Single, Clear S 13.0 8.0 40.0 48.22 0.51 984.0 3.Single, Clear W 1.0 6.0 30.0 57.68 0.97 1678.0 4.Single, Clear N 1.0 6.0 15.0 30.19 0.98 441.0 5.Single, Clear E 1.0 6.0 75.0 63.97 0.97 4655.0 As -Built Total: 166.0 8009.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 306.0 0.70 214.2 1. Concrete, Int Insul, Exterior 4.1 2273.0 1.18 2682.1 Exterior 2273.0 1.90 4318.7 2. Frame, Wood, Adjacent 11.0 306.0 0.70 214.2 Base Total: 2579.0 4532.9 As -Built Total: 2579.0 2896.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 18.0 1.60 28.8 1.Exterior Insulated 24.0 4.80 115.2 Exterior 24.0 4.80 115.2 2-Adjacent Wood 18.0 2A0 43.2 Base Total: 42.0 144.0 As -Built Total: 42.0 158.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1851.0 2.13 39426 1. Under Attic 19.0 1851.0 2.82 X 1.00 5219.8 Base Total: 1851.0 3942.6 As -Built Total- 1851.0 5219.8 FLOOR TYPES Area X BSPM = Paints Type R-Value Area X SPM = Points Slab 182.0(p) -31.8 -5787.6 1. Slab -On -Grade Edge Insulation 0.0 182.0(p -31.90 -5805.8 Raised 0.0 0.00 0.0 Base Total: -5767.6 As -Built Total: 182.0 -5805.8 INFILTRATION Area X BSPM =Points Area X SPM = Points 1851.0 14.31 26487.8 1 .0 14.31 26487.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A m Details ADDRESS: Lot: . Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT Summer Base Points: 37432.7 Summer As -Built Points: 36965.6 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 41500btuh ,SEER/EFF(13.0) Duds:Unc(S),Con(R),Int(AH),R6.0(INS) 37432.7 0.3250 12165.6 36966 1.00 (1.08 x 1.150 x 0.S5) 0.260 36965.6 1.00 1.061 0.260 0.950 0.950 9686.8 9686.8 EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 600A-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT # - I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1851.0 9.11 3035.0 1.Single, Clear S 1.0 4.0 6.0 9.90 1.05 62.0 2.Single, Clear S 13.0 8.0 40.0 9.90 2.15 852.0 3.Single, Clear W 1.0 6.0 30.0 13.25 1.00 398.0 4.Single, Clear N 1.0 6.0 15.0 15.07 1.00 225.0 5.Single, Clear E 1.0 6.0 75.0 12.37 1.01 935.0 As -Built Total: 166.0 2472.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 306.0 1.80 550.8 1. Concrete, Int Insul, Exterior 4.1 2273.0 3.31 7512.3 Exterior 2273.0 2.00 4546.0 2. Frame, Wood. Adjacent 11.0 306.0 1.80 550.8 Base Total: 2579.0 5096.8 As -Built Total: 2579.0 8063.1 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 18.0 4.00 72.0 1.Extedor Insulated 24.0 5.10 122.4 Exterior 24.0 5.10 122.4 2.Adjacent Wood 18.0 5.90 106.2 Base Total: 42.0 194.4 As -Built Total: 42.0 228.6 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1851.0 0.64 1184.6 1. Under Attic 19.0 1851.0 0.87 X 1.00 1610.4 Base Total: 1851.0 1184.6 As -Built Total: 1851.0 1610A FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 182.0(p) -1.9 -345.8 1. Slab -On -Grade Edge Insulation 0.0 182.0(p 2.50 455.0 Raised 0.0 0.00 0.0 Base Total: 345.8 As -Built Total: 182.0 455.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1851.0 -0.28 -518.3 1851.0 -0.28 -518.3 EnergyGauge® DCA Form 60OA-2004R EnergyGauge@/FIaRES'20D4 FIRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: Lot: _, Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: -I BASE AS -BUILT Winter Base Points: 8646.8 Winter As -Built Points: 12310.8 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier. Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 15500 btuh ,EFF(8.5) Ducts:Unc(S),Con(R),Int(AH),R6.0 8646.8 0.5540 4790.3 12310.8 1.000 (1.068 x 1.160 x 0.87) 0.402 12310.8 1.00 1.083 0.402 0.950 0.950 5084.7 5084.7 EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FQRM 60OA-2004R EnergyGauge® 4.5 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: Lot: _, Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.92 3 1.00 2460.00 1.00 7380.0 As-Bultt Total: 7380.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water = Total Points Points Cooling Points + Heating + Hot Water = Total Points Points Points 12166 4790 7380 24336 9687 5085 7380 22151 PASS EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FIaRE52004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: Lot: . Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKI IRT COMPONENTS SECTIOW---7 REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 efrn/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top Diate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the Perimeter, Penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from Insulation; or Type IC rated with < 2.0 cfrn from conditioned space, tested. Multi -story Houses 606.1ABC.1.25 Air barrier on perimeter of floor cavity between floors. Additional Infiltration regts 606A.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA. have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump Omer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed. Insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readil accessible manual or automatic thermostat for each system. Insulation 604.1. 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. J I- . Common ceiling & floors R-11. - EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.8 The higher the score, the more efficient the home. CUSTOM, Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, 1. New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, ifmuld-family I _ 4. Number ofBedmoms 3 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft') 1851 ft' 7. Glass typel and area: (Label reqd. by 13-104A.5 if not default) a. U-factor. Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 166.0 ft' _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 166.0 ft' _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0,182.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, hit Imul, Exterior R=4.1, 2273.0 ft' b. Frame, Wood, Adjacent R=11.0, 306.0 ft' _ c. N/A _ d. N/A _ e. N/A _ 10. Ceilingtypes a. Under Attic R=19.0, 1851.0 ft' _ b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, BF -Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone hearing) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection Otherwise, a new EPL Display Card will be completed based on installed Code c features. Builder Signaturi!. Q L (� .nDate: "a -c)llddress of New Home: 1 l 16 1'or' y -lrtP- O' City/FL Zip: *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86for a US EPAIDOEEnergyStartxrdesignation), your home may qualify for energy efficiency mortgage (EEA1) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. Cap: 41.5 kl3ftOw _ SEER: 13.00 Cap: 15.5 kBtu/hr HSPF: 8.50 Cap: 40.0 gallons EF: 0.92 I Predominant glass type. For actual glass type and auras see Summer & Winter Glass output on aSyBges 2&4. LnergyGauge® (Version: FLRCv4.5) PT, _