HomeMy WebLinkAboutMISC LETTERS. •- .
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com Racerv,
February 26, 2019
Re: Shutter Installation
9900 S. Ocean Dr. (#1008)
Jensen Beach, FL 34957
To Whom It May Concern:
MqR 0 a
ae oltb9
�9Z) 29j
Cfl%10,7rt �qt
SCByNED
St. Lucie county
Our office has calculated the required design pressures in accordance with ASCE 7-10
and Florida Building Code 2017 for the installation of accordion shutters at the above
referenced address.
I Ro�-C,1-77
Wind speed: Vwc: 165 mph, Vad: 128 mph
Exposure: D
Enclosure Type: Enclosed
Shutter Size: 96" Maximum Height
Shutter Location: Covered Porch (See Attached Sketch)
Required Design Pressure: +51.3 / -68.7 PSF
ST. LUC1E COUNITY
BUILDING DIVISION
REVIEWED
FOR COMPUANCE.
DATE 3_ 62_
NS AND PER>d:T
MUST BE KEPT ON -X 3 09
NO INSPECTICPN %%It I. 'ir C i."E
Shutters to be installed shall be equal to, or exceed the required design pressures as listed
above "Required Design Pressure"."
Accordion Shutters shall be installed in accordance with the shutter manufacturer's
installation instructions and Florida Product Approval and Florida Building Code 2017.
Accordion Shutters shall be FL# 389.2.
for your attention to this matter.
Submi ed by:
PAU LCH INC.
Paul W lch P.E.
Reg. No 9945
THESE PLANS AP40 ALL PROPOSMD VrPOR
ARE 8UE3JCCT TO Ah1Y COl?(,E'CTIi !PI,
tREQUIRED BY FIELD INSPECTQRS T! L T
"� MAY BE NECESSARY IN ORMM TO
COFJPLY MTH ALL APPLICABLE COCES.
CONCP'ALHO FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILTTy OF THE
CONTRgCTOR OFRECORO
FILE