Loading...
HomeMy WebLinkAboutMISC LETTERS. •- . PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com Racerv, February 26, 2019 Re: Shutter Installation 9900 S. Ocean Dr. (#1008) Jensen Beach, FL 34957 To Whom It May Concern: MqR 0 a ae oltb9 �9Z) 29j Cfl%10,7rt �qt SCByNED St. Lucie county Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of accordion shutters at the above referenced address. I Ro�-C,1-77 Wind speed: Vwc: 165 mph, Vad: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter Location: Covered Porch (See Attached Sketch) Required Design Pressure: +51.3 / -68.7 PSF ST. LUC1E COUNITY BUILDING DIVISION REVIEWED FOR COMPUANCE. DATE 3_ 62_ NS AND PER>d:T MUST BE KEPT ON -X 3 09 NO INSPECTICPN %%It I. 'ir C i."E Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure"." Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2017. Accordion Shutters shall be FL# 389.2. for your attention to this matter. Submi ed by: PAU LCH INC. Paul W lch P.E. Reg. No 9945 THESE PLANS AP40 ALL PROPOSMD VrPOR ARE 8UE3JCCT TO Ah1Y COl?(,E'CTIi !PI, tREQUIRED BY FIELD INSPECTQRS T! L T "� MAY BE NECESSARY IN ORMM TO COFJPLY MTH ALL APPLICABLE COCES. CONCP'ALHO FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILTTy OF THE CONTRgCTOR OFRECORO FILE