Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT398 E Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop Dania Beach, FL 33004954.399.8478 PH Certificate of Authorization: 29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of Trinity Glass International "6'8 9 Opaque Fiberglass Door Outswing" .>GANNED (Impact) BY inie County for Florida Product Approval FL# FL20867 Report No. 4419 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Exterior Door Sub — Category: Swinging Exterior Door Assemblies Product: Opaque Fiberglass Door Outswing Material: Fiberglass Product Dimensions: See Installation Instructions, FL-20867.2 Prepared For: Trinity Glass International 33625 1" Way S Federal Way, WA 98003 Prepared by: Hermes F. Norcro, P.E. Florida Professional Engineer # 73778 Date: 07/25/2016 Contents: Evaluation Report Pages 1— 4 Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2016.08.26 14:51:10-04'00' ``�StF frnOrrr''' - ` �0 7 s a TT `9/ONAL Hermesrff! MiWo, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Date: 07/25/2016 Certificate of Authorization: 29575 Report No: 4419 Manufacturer: Trinity Glass International Product Category: Exterior Door Product Sub -Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(d) Product Name: Opaque Fiberglass Door Outswing (Impact) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Trinity Glass International based on Method id of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions FL-20867.2, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, includiDE the "High Velocity Hurricane Zone' (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing FL-20867.2 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions FL-20867.2 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS A Perfect Solution in Every Drop Date: 07/25/2016 Certificate of Authorization: 29578 Report No: 4419 Quality Assurance: The manufacturer has demonstrated compliance in Accordance with the Florida Building Code and Florida Product Approval system for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation Management Institute. (FBC Organization # QUA1789) Performance Standards: Referenced Data: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM 283-04 • ASTM E330-02 • ASTM E331-00 • AAMA 1304-02 1. Product Testing performed by Architectural Testing, Inc. (FBC Organization # TST1910) Report #: F5877.01-109-18, Report #: F7081.01-109-18, Report#:F8603.01-109-18, Report #: B5950.01-106-18, Report #: C3995.01-106-18, Report #: D8467.01-106-18, Report #: D8467.02-106-18, Report Date:04/12/2016 Report Date:05/12/2016 Report Date:05/27/2016 Report Date:08/29/2012 Report Date:12/10/2012 Report Date:01/23/2015 Report Date:01/23/2015 2. Product Testing performed by Testing Evaluation Laboratories, Inc. (FBC Organization # TST4317) Report #: TEL 06-0918-2, Report Date: 10/10/2006 3. Report #: TEL 01370079, Report #: TEL 01370210, Report #: TEL 01470437, Report #: TEL 04251336, Report #: TEL 02010411, Report #: TEL 02010412, Report #: TEL 08-01370020, Report Date:12/05/2008 Report Date:12/21/2009 Report Date:11/30/2011 Report Date:05/05/2015 Report Date:10/11/2011 Report Date:10/11/2011 Report Date:06/10/2008 Product Testing performed by ETC Laboratories (FBC Organization # TST2411) Report #: ETC-05-781-16179.0, Report Date: 12/21/2005 Report #:ETC-05-781-16208.0, Report Date:12/21/2005 Report #:ETC-05-781-17122.0, Report Date:10/19/2005 Report #:ETC-05-756-10828.0, Report Date:12/31/2001 Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 Installation: 1 BUILDING DROPS A Perfect Solution in Every Drop Date: 07/25/2016 Certificate of Authorization: 29575 Report No: 4419 Refer to Installation Instructions (FL-20867.2) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (FL-20867.2) for design pressures based on size, configuration, and glass types. Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4