Loading...
HomeMy WebLinkAboutNOACOUNTY `d ; DEPARTMENT OF REGULATORY AND ECONOMIC BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MAR 12 29i MI -DAD" COUNTY O'DU -CONTROL SECTION ST. Lucie County, permit inl80 'SW 26 Street. Room 208 3 9 iami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy International Impact Building Products, LLC 5900 Australian Avenue, Suite #300 SCANNED West Palm Beach, FL 33407 BY SCOPE: St. Lucie County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Titan 90" Aluminum Sliding Glass Door w/ reinforcements -Impact APPROVAL DOCUMENT: Drawing No. WII-47 Rev D, titled "Series Titan 90 Alum Sliding Glass Door (L.M.I.)", sheets 1 through 7 of 7, prepared by AL-Farooq Corporation, dated 08/22/11 and last revised on MAR 27, 2018, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. The frame area of alternate size unit shall not exceed the frame area of the tested approved unit per FBC 2411.3.2.4 (i) (1). The panel height also must not exceed. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 14=0624.22 and consists of this page 1 and evidence pages E-1 & E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq 1. Chanda, P.E. MIAMI-DADE COUNTY NOA No. 18-0412.01 Expiration Date: July 01, 2024 Approval Date: June 28, 2018 Page 1 International Impact Building Products, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under previous approvals A. DRAWINGS (submitted under files #11-0923.01/# 09-0127.14) 1. Manufacturer's die drawings and sections. 2. Drawing No. WII-47 Rev C, titled "Series Titan 90 Alum Sliding Glass Door (L.M.I.)", sheets 1 through 7 of 7, prepared by AL-Farooq Corporation, dated 08/22/11 and last revised on AUG 12, 2014, signed and sealed by Javad Ahmad, P.E. B. TESTS (submitted under files #11-0923.01/# 09-0127.14) 1. Test reports on 1) Air Infiltration Test, per TAS 202-94 2) Uniform Static Air Pressure Test, Loading per TAS 202-94 3) Water Resistance Test, per TAS 202-94. 4) Forced Entry Test per FBC 2411.3.2.1 and TAS202-94. 5) Large Missile Impact Test, per TAS 201-94 6) Cyclic Wind Pressure Loading, per TAS 203-94 Along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Hurricane Testing Laboratories, Test Report No. HTL-0171-0713.07, dated 08-01- 2008, signed and sealed by Vinu Abraham, P.E. 2. Additional OXO sliding Glass Door test report No. HTL-0171-106-07, dated 03-16-07 per TAS 201, 202 and 203-94, signed and sealed by Vinu Abraham, P.E., issued to Plaza Door Co (Now known as International Impact Products, LLC). C. CALCULATIONS (submitted under files #11-0923.01) 1. Anchor verification calculations and structural analysis, complying with FBC-2007, prepared by Al Farooq Corporation, dated 09/20/11 and last revised on 0CT25, 2011, signed and sealed by Javad Alimad, P.E. 2. Glazing complies w/ ASTME-1300-02,-04 &-09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0624.02 issued to E.I. DuPont DeNemours & Co., Inc. for the "DuPont Sentry Glass interlayer@", expiring on 01/14/17. F. STATEMENTS 1. Statement letter dated 06/24/14, compliance to FBC2014 (5'n edition) and No financial interest, prepared by Al Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Statement letter dated 11/16/11 compliance to FBC2010, prepared by Al Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (submitted under files #11-0923.01) 3. Statement letter dated 04/09/09, issued by Plaza Doors of all assets sold to Impact Building Products, signed by Roy Elwell, president Plaza Door (original in file # 09-0127.14) 4. Statement letter dated 04/09/09, issued by Impact Building Products of all assets purchased from Plaza Doors, signed by Michael Fry, Managing Partner, International Impact Building Products ( original in file #09-0127.14) 5. Laboratory compliance, as a part of above test reports. Ishaq I. Chanda, P.E. Product Control Examiner NOA No. 18-0412.01 Expiration Date: July 01, 2024 Approval Date: June 28, 2018 E-1 International Impact Building I ucts, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED G. OTHER 1. This NOA revises & renews NOA # 11-0923.01, expiring 07/01/18. 2. Bill of Sales Assignment and Loan Purchase agreement between National City Bank and International Impact Building Products. 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. Wll-47 Rev D, titled "Series Titan 90 Alum Sliding Glass Door (L.M.I.)", sheets 1 through 7 of 7, prepared by AL-Farooq Corporation, dated 08/22/11 and last revised on MAR 27, 2018, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2017 (6` Edition), prepared by Al Farooq Corporation, dated MAR 27, 2018, signed and sealed by Javad Abmad, P.E. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.17-0808.02 issued to Kuraray America, Inc. (former E.I. DuPont De Nemours & Co., Inc.) for "Kuraray Sentry Glass interlayer®", expiring on 07/04/23. F. STATEMENTS 1. Statement letter of conformance to FBC 6t1 Edition (2017) and of no financial interest, prepared by Al Farooq Corporation, dated 01/26/18, signed and sealed by Javad Ahmad, P.E. 2. Statement of lab compliance, as part of test report. G. OTHER 1. This NOA revises & renews NOA # 14-0624.22, expiring 07/01/24. Ishaq I. Chanda, P.E. Product Control Examiner NOA No.18-0412.01 Expiration Date: July 01, 2024 Approval Date: June 28, 2018 E-2 DESIGN LOAD CAPACITY - PSF AVG. PANEL WIDTH INCHES PANEL HEIGHT INCHES EXT.(+) INT.(-) 36 42 48 52 54 60 96 1 90.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 86.7 86.7 1 78.0 78.0 36 42 48 52 54 60 102 90.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 86.7 86.7 78.0 78.0 36 42 48 52 54 108 90.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 86.7 86.7 36 42 48 52 54 114 90.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 86.7 86.7 36 42 48 52 120 90.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 DOOR HEIGHT AND WIDTH SIZE MUST COMPLY EGRESS REQUIREMENTS PER FBC. SERIES 'TITAN 90' ALUMINUM SLIDING GLASS DESIGN LOAD RATING FOR DOORS TO BE AS PER CHART SHOWN ABOVE. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (GTH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). DAYLITE OPENINGS: 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE D.L.O. HEIGHT = PANEL HEIGHT - 7.000" M ow a� 0 o- MAX. DOOR FRAMF WInTH OX (SHOWN) XO (REVERSE) XX OXX (SHOWN) OXXO (SHOWN) OXXX "MU APPROVED CONFIGURATIONS 1/4" HEAT STREN'D GLASS .090" Interlayer SentryGlas By 'Kuraray America, Inc.' 1/4" HEAT STREN'D GLASS BILL OF MATERIAL ITEM PART # QUANTITY DESCRIPTION 1 PDC-009 1 FRAME HEAD 2 PDC-012 1 FRAME SILL 3 PDC-010 2 FRAME JAMB 4 PDC-058 1/ PANEL PANEL TOP RAIL 5 PDC-059 1/ PANEL PANEL BOTTOM RAIL 6 PDC-060 1/ PANEL JAMB/LOCK STILE 7 PDC-061 1/ PANEL INTERLOCK STILE 8 PDC-002 AS READ. ASTRAGAL STILE 10 PDC-022 AS REOD. SCREEN ASTRAGAL 11 PDC-041 AS READ. HAND RAIL 12 PDC-062 1/ PANEL INTERLOCK STILE REINFORCEMENT, LENGA 13 PDC-092 2/ PANEL INTERLOCK REINFORCEMEM, 12" LQ7",� 14 PDC-093 1/ PANEL STILE REINFORCEMENT, LENGTH �= _ IL 15 PDC-085 1 HI —RISE ADAPTER 16 2-270-0 AS READ. GLAZING GASKET (X-1842) 17 3-310-0 2/ MOV. PANEL ADJUSTABLE ROLLER ASSEMBLY ALUMINUM HOUSING, DELRIN TIRE, ST. ST 18 2-322-0 — DEADLOCK #1847-02 SS 19 2-351-0 — LOCK ESCUTCHEON #4430 20 3-001-0 — LOCK KEEPER 21 3-008-0 — TRACK RAIN PAN 22 3-009-0 — H.P. WEATHER TAB 23 2-400-0 AS READ. .270 WIDE POLY —BOND FINSEAL #PB-84: 24 2-402-0 AS READ. .270 WIDE POLY —BOND WOOLPILE #PB-7 25 2-407-0 AS REOD. .270 WIDE POLY —BOND FINSEAL #PB-75: 26 2-222-0 AS READ. BULB W'STRIPPING (EV-277) 27 2-025-0 — #10-24 X 1/4" PFH UC SMS _ — 30 2-010-0 — #12 X 1-1/4" PPH SS SMS i 31 2-040—D — #8 X 1" FH SMS 32 2-007-0 — #14 X 1-1/4" PH SMS 33 2-019-0 — #8 X 1/2" PH SMS 34 2-069-0 — #8 X 1-1/4" SMS 35 2-027-0 — #10 X 1-1/4" MS TYPE F FH 36 2-042-0 — #8 X 3/4" PH SMS 39 2-027-0 1 #10 X 1-1/4" MS TYPE F FH TYPICAL ANCHORS IN PAIRS CLUSTER OF 4 PAIRS AT STILE ENDS TYPICAL ANCHORS IN PAIRS Y m o TYPICAL AN( SEE ELEV. FOR SPACING CLUSTER OF 4 PAIRS AT STILE ENDS a M w CLUSTER OF EE ELEV. FOR SPACING m m SEE ELtV. I 1BY WOOD BUCK O o EDGE DIST. 3" MIN. (SEE NOTE BELOW) 3 '� z 0 'e,CONCRET6 a I } ow 3 }AIN.' ' a"• CONCRETE N o 3 )Ktf ° - EDGE DIST. 3". MIN. 3 KSI MIN. EDGE DI 3" MIN. ULu O23 203 N w N w 1BY OR 2BY WOOD BUCKS AND METAL STRUCTURE NOT BY PLA MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1 /4" DIA. ULTRACON BY 'ELCO (Fu=177 KSI, Fy=155 r INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/JAMB THRU 1BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/JAMBS 1-1/2" MIN. EMBED INTO GROUT FILLED —BLOCKS DIRECTLY INTO CONC. OR BLOCKS 1-1/2" MIN. EMBED INTO CONCRETE (HEAD/SILL) 2" MIN. EMBED INTO CONC. OR FILLED -BLOCKS (JA 1 /4" DIA. TEKS OR SELF DRILLING SCREWS (GRADE e INTO MIAMI-DADE COUNTY APPROVED MULLIONS TYPICAL ANCHORS TYPICAL ANCHORS IN PAIRS OSEE ELEV. FOR SPACING F 1/4" MAX. .. META STRUCTUR O FRAME HEAD 082 TYP. 3. O PANEL TOP RAIL I O PANEL BOTTOM RAIL O 4. FRAME SILL �.125 4.000 2. 0 JAMB/LOCK STILE Q INTERLOCK STILE 1- 1.575 --1 1 .125 2.339 .931 .250 � INTERLOCK STILE STIFFENER �.239 .750 INTERLOCK REINFORCEMENT I �{ 1.250 .250 .125 � 1.650 i I ASTRAGAL STILE ---1 M—.570 14 STILE REINFORCEMENT 675 1 1.323� .062 o SCREEN ASTRAGAL PANEL TOF FRAME TOP CORNER JAMB NOTCHED TO RECIEVE HEADER AND SILL RIBS APPLY BEAD OF SONNEBORN NP1 SEALANT AT TOP AND BOTTOM JOINTS APPLY BEAD OF SONNEBORN NP1 SEALANT AT TOP AND BOTTOM JOINTS 32