HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online,_ _
Page 1 of 3
I
Mn�en
z�
Z
&CIS Home '. Log In US., Regmuatlon Hot Topics Submit Su.h.,. Stan&Fa= P.Inications
F&C staff 1 SC19 Site Map Links :•Search
� USER: PUEIicAUSPrroval
y �Product FILE
dbor
COPY
Produd Approval Menu >Produdpr Aooglicatio-n
Search >Alllkat'/i U!� AP Uon Oetall
• '1 { ,'
FL L )Q ���1
#J
`U^3
^— FL389-119
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
C
SCANNED
St LuBy
cie County
American Shutter Systems Association, Inc.
4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Bill Feeley
lrodriguez@easternmeta1.com
REVIEWED FOR
CODE' COMPLIANCE
Shutters ST• LUCIE COUNTY
Accordion BOCC
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
5 Evaluation Report - Hardcopy Received
Walter A.. Tillit, Jr. P.E.
PE-44167
National Accreditation and Management Institute
12/31/2018
John Henry Kampmann Jr.
J, Validation Checklist - Hardcopy Received
Certificate of Independence FIL 9 R9 COI AMERICAN SHUTTER SV;�f M ASSOC. INr. DRAWING
17-107 CERTIFICATE 17F INDEPENDENCE,,FOF
FL389 R9 COI AMERICAN SHUTTER SVSTEEMS ASSOC..
INC
DRAWING ON OF INDEPENDENCE
( I) PDF
FL3HP_R9 COI AMERICAN SHUTTER SV$'fEMS DRAWING 1Z:j03_
CERTIFICATE OF INDEPENDENCE.PDF
Referenced Standard and Year (of Standard) Standard
Year
ASTM E-1886
2005
ASTM E-1996
2005
ASTM E-330
2002
TAS 201, 202, 203
1994
Equivalence of Product Standards
Certified By
https://floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgvYYHH2vJvx53Mws... 1 /3/2018
Florida Building Code Online_ r Page 2 of 3
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/16/2017
Date Validated 10/18/2017
Date Pending FBC Approval 10/19/2017
Date Approved 12/12/2017
FL dr I Model, Number or Name
389.1 Bertha HV Accordion Shutter -
Blade 3 - (Non-HVHZ) - Drwg 17-
108
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level'D".Max span is 12'-3" for 40 psf
positive ASO load and 13'-0" for 35 psf negative ASD load
the HV3 blade w/o window blade,5'-2" for 110 psf ASD load
for HV3 blade w/o window blade and W-11" for 62 psf, 9'-
11" for 55 psf HV3 blade w/window blade working in
unison.Max.span for HV3 blade w/o window blade for
installations into Metal Stud walls is 79" for max. ASD
pressure rating of +72,-72 and 84" for +64,-64 psf. See
sheet 5 for other spans and ASD pressures.
Description
Extruded aluminum interlocking blades retained by tracks
(top and bottom) for storm protection
Installation Instructions
FL389 R9 II AMERICAN SHUTTER SYSTEMS DRAWING
17-108 BERTHA HV ACCORDION SHUTTER SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER 5VST,IiMS DRAWING
17-108 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
389.2 I Bertha HV Accordion Shutter -Blade I Extruded aluminum interlocking blades retained by tracks
1 Only- (Non-HVHZ)- Drwg 17-107 (top and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. Span Is. 16'-0' for 30
p.s.f negative ASD load depending on centermates and
locking rod configuration for the HVS blade, 8'-0"for +64,
-72 p.s.f. A.S.D. load for HV blade for Keystone mountings
7'-0" p.s.f. for metals stud mountings and e'-O" for 110
p.s.f. for HV1A working In unison. See sheets 7, 11 and 20
respectively of Installation drawings for other spans and
Installation Instructions
FL389 R9 II AMERICAN SHUTTER SYSTEM ASSOC
INC. DRAWING 17-107 BERTHA HV ACCORDION SHSITTER
SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEM ASSOC„
INC. DRAWING 17-107 PRODUCT OF EVALUATION
REPORT.PDF
Created by Independent Third Party: Yes
389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
COMBO- (Non-HVHZ)- Drwg 17- (top and bottom) for storm protection
106
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile. Max. 16'-0" span at 30 p.s.f ASD load
for Blade 1 and 18'-0" for Blade 2. See schedules on sheet
12, 25 and 28 respectively
Installation Instructions
FL389 R9 lI AMERICAN SHUTTER SYSTEMS ASSOC
INC. DRAWING 7-106 BERTHA HV ACCORDION SH—I TIER
SYST.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEMS ASS>OCC.
INC. DRAWING I7-106 PRODUCT EVALUATION
Third Party: Yes
Bark E
The State of Florida is a Mean employer. Convrlaht 2007-2013 State of Florida.:: 1ylwUv Statement:: p r ss0lli�Statement Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a puble-records notional, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.'Pursuant to
Section 455.275(t), Flonda statutes, effective October 1, Z012, licensees licensed under chapter 455. F.S. must provide the department with an email address 1
they have One. The emails provided may be used for official c mon nmcation with the Iicement. However email addrones are public record. Ir you do net wish to
supply a personal address. Please provide the 0epartment with an email address which an be made available to the public. To determine if you are a licensee under
Chapter 455. F.s., please dick bete .
Product Approval Accepts:
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGE V XQwtDgvYYHH2vJvx53 Mws... 1 /3/2018
Florida Building Code Online , _ Page 3 of 3
Credit Card
Safe
https://flor-idabuilding.org/pr/pr_app_dtl.aspx?param=wGE V XQwtDgvYYHH2vJvx53 Mws... 1 /3/2018