HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSSCANNED 1 ' - _
BY ALL AMERICAN
St. Lucie County SHUTTERS & GLASS
1638 Donna Road, Msl Palm Beach, FL
riz•9suz • tiwnv-aitamencansnuuers-com
Information
Owner: ROHR, MARY
Address: 3000 N HIGHWAY AIA
10-B
FORT PIERCE, FL 34949
Information
Wind Zone: 170 MPH.
Exposure Category: D
Minimum Building Dimension: 160 ft.
Mean Roof Height: 112 ft.
Risk Category: III
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
LPressure s
1
hit
90
0.0
0.0
2
Int
460 101.75 90
41.9
-48.6
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components aad Cladding. 6ih Edition (2017) Florida Building Code.