HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSSCANNED 1 ' - _ BY ALL AMERICAN St. Lucie County SHUTTERS & GLASS 1638 Donna Road, Msl Palm Beach, FL riz•9suz • tiwnv-aitamencansnuuers-com Information Owner: ROHR, MARY Address: 3000 N HIGHWAY AIA 10-B FORT PIERCE, FL 34949 Information Wind Zone: 170 MPH. Exposure Category: D Minimum Building Dimension: 160 ft. Mean Roof Height: 112 ft. Risk Category: III Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative LPressure s 1 hit 90 0.0 0.0 2 Int 460 101.75 90 41.9 -48.6 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components aad Cladding. 6ih Edition (2017) Florida Building Code. Page 1 of 1