HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Pagel of 3
�sl��ess,�&xprof�s�onal�Regulatto'ny�� �� �
? garguorc? ieH11 oer�{ oevnwv�b orn .jvNrIQperry
d�110% Product Approval
FILE • •.
'6
FL
;T1389=R9
Application Type
Code Version
Revision SCANNED
2017
Application Status
Ppr v- e—dZ- BY
St. Lucie County
Comments
Archived
Product Manufacturer
American Shutter Systems Association, Inc.
Address/Phone/Email
4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature
Bill Feeley
lmdriguez@easternmetal.com
Technical Representative
Address/Phone/Email
�p�
REVIEWED FOR
REVIEWED
Quality Assurance Representative
CODE COMPLIANCE
Address/Phone/Email
ST. LUCIE COUNTY
Category
Subcategory
Shutters
BOCC
Accordion
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed
Walter A.. Tillit, Jr. P.E.
the Evaluation Report
Florida License
PE-44167
Quality Assurance Entity
National Accreditation and Management Institute
Quality Assurance Contract Expiration Date
12/31/2018
Validated By -
John Henry Kampmann Jr.
Validation Checklist - Hardcopy Received
Certificate of Independence
EI 369 R9 COI AMERICAN SHUTTER SYSTEM ASSOC., INC,DRAWING
17-107 CERTIFICATE OF INDEPENDENCF,M
EQU R9 COI AMERICAN 5HUT-rizil SYSTEMS ASSOC IN
DRAWING 17-106 CERTlEIC8n N OF iND P ND N E r I PDF
FL.389 R9 COI AMERICAN SHUTTER SYS3-EMS DRAWIN 1710R
CERTIFICATE OF INDEPENDENCE PDF
Referenced Standard and Year (of Standard)
Standard Year
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
https://www.floridabuildina.ora/nr/i)r ann dtl.asnx?naram=wCTF.VXOwN)nvYYHN?vTx,';
Florida. Building Code Online
Page 2 of 3
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/18/2017
Date Validated 10/18/2017
Date Pending FBC Approval 10/19/2017
Date Approved 12/12/2017
Summary of Products
FL ffi j Model, Number or Name I Descriutinn 1
389.1 Bertha HV Accordion Shutter -
Blade 3 - (Non-HVHZ) - Drwg 17-
108
Limits of use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D".Max span is 12'-3" for 40 psf
positive ASD load and 13'-0" for 35 psf negative ASD load
the HV3 blade w/o window blade,5'-2" for 110 psf ASD load
for HV3 blade w/o window blade and 8'-11" for 62 psf, 9'-
11" for 55 psf HV3 blade w/window blade working in
unison.Max.span for HV3 blade w/o window blade for
installations Into Metal Stud walls is 79" for max. ASD
pressure rating of +72,-72 and 84" for +64,-64 psf. See
Extruded aluminum interlocking blades retained by tracks
(top and bottom) for storm protection
Installation Instructions
verinea By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER R YST M DRAWING
17-108 PRODUCTEVAIIIATIONREPORT.IODIF
Created by Independent Third Party: Yes
389.2 I Bertha HV Accordion Shutter -Blade I Extruded aluminum interlocking blades retained by tracks
1 Only- (Non-HVHZ)- Drwg 17-107 (top and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. Span Is 16'-0" for 30
p.s.f negative ASD load depending on centennates and
locking rod configuration for the HVI blade, 8'-0" for+64,
-72 p.s.f. A.S.D. load for HV blade for Keystone mountings
7'-0" p.s.f. for metals stud mountings and 8'-0' for 110
p.s.f. for HV1A working in unison. See sheets 7, 11 and 20
respectively of installation drawings for other spans and
pressures.
Bertha HV Accordion Shutter-
COMBO- (Non-HVHZ)- Drwg 17-
106
Installation Instructions
FL389 R9 II AMERICAN SHU ER SYSTEM ASSOC._
SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc
Created by Independent Third Party: Yes
Evaluation Reports
Party: Yes
cxrruci aluminumTnterlocking blades retained by tracks
(top and bottom) for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL389 R9 II AMERICAN SHUTTER SYSTEMS ASSOC
Approved for use outside HVHZ: Yes INC DRAWING 17-106 BERTHA HV ACLQRDfON SHI 17TER
Impact Resistant: Yes SYST PDF
Design Pressure: N/A Verified By: American Test Lab of South Florida Inc.
Other: Large missile. Max. I6'-0" span at 30 P.s.f ASD load Created by Independent Third Party: Yes
for Blade 1 and 18'-0" for Blade 2. See schedules on sheet Evaluation Reports
12, 25 and 28 respectively FL389 R9 SE AMERICAN SHUTTER c51EMS ASSOC,
INC DRAWING 17-106 PRODUCT EVALUATION
� , REPORT.PDF
Created by Intlependent Third Party: Yes
Bark neat
The state of Fbdda Is an AA/EEO employer. Cm,mht 7007.70t a State of Florida
S"aMment ;; Ar�c.ibili_��ent ;; aenna teat
Under Florida law, email addresses are public records. If you do not want your e-ri ll address released in response te a publicrecords repuesp do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any Questions, please contact 850.487.1395. -Pursuant to
section 455.275(1), Florida Statutes, enecaw October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if
May have one. The emalis provided may be used far official communication with the licensee. However email addresses are public recent. If you do not wish to
supply a personal address, pleats provide the Department with an email address which ran be made available to the public To determine if you are a Ikensee under
chapter 455. F.S., please 9klr here .
Product Aperture] Axepts:
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQwtDgvYYHH2vJvx5... 1/8/201 R