Loading...
HomeMy WebLinkAboutENGINEERINGr , ENGINEER: JCH 1 OF 1 WALL COMPONENTS & CLADDING SERVICE WIND LOADS AREA Interior End ft2 Zone (pso Zone s 10 48 -52 48 -64 20 46 -50 46 -60 30 44 -48 44 -57 40 43 -48 43 -55 50 43 -47 43 -54 75 42 -46 42 -51 100 41 -45 41 -50 200 38 -43 38 -45 500 36 -40 36 -40 ADDRESS: 325 Pandora Ave., Fort Pierce, FL 34951 CODE: A.S.C.E. 7-10 Velocity = 170 m.p.h. Risk Category= II RECEIVED Exposure = D Mean Roof Height = 15 Feet MAR 2 7 2019 Kzt = 1.0 Kd = 0.85 Si. Lucie County, Permitting G = 0.85 GCpi = +/- 0.18 qh = 40.5 p.s.f. End zone = 3.0 Feet SCANNED BY St. Lucie County Jason Hanchuk, P.E. #56787 1770 Pierside Circle ellington, FL 33414 (561) 818-1935 Date: 3/20/2019 •i5 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COuNTy ®®CC 3/20/2019