April 26, 2019 I G o,` a 13
Orange Avenue Baptist Church
Atm. Laurence Ivey, Director SCANNED
100 Cyclone Drive BY
Fort Pierce, FL 34945 St. Lucie Count
n g.+eb9 V
y I
iRE: Finished floor waiver
r
4}
Dear Mr. Ivey:
Please accept this letter in response to your written request received April 17, 2019 to waive
the finished floor elevation of 18" above the crown of the road. The waiver request is for an
enclosed restroom within a proposed open basketball pavilion for an existing church and
school at 100 Cyclone Dr., Fort Pierce.
Pursuant to Section 7.04.01(C-3) of the St. Lucie County Land Development Code, the Planning
and Development Services Director has the authority to grant administrative relief, when
topographical conditions are such that compliance with this subsection would be impracticable
or cause grade level conditions detrimental to adjacent or nearby property, consistent with the
intent of the Flood Protection regulations and any other applicable portion of this Code.
The Planning and Development Services Director has granted your request for administrative
relief of the finished floor elevation based on the following determinations:
1 The property is in Flood zone X.
2 The center line of the adjacent road is 23.28' NAVD.
3 The finished floor elevation of existing buildings (church, school and accessory) are at
24.05' NAVD.
4 The proposed finished floor elevation for the proposed restroom of the basketball
pavilion is 24.05' NAVD which is 0.77' above the center line of the road and matching
the existing buildings on the property.
This approval does not in any way constitute authorization to begin construction. Prior to the
commencement of any construction on this property, an application for specific building permit
must be obtained from this department.
Please feel free to contact me at (772) 462-2822 if you have any questions.
IS�inc�erely
W_v
Leslie Olson, AICP
Planning and Development Services Director
cc: Monica Graziani, Building and Code Compliance Manager
Gary Stepalavich, Building Official
Melissa Brubaker, Zoning and Permitting Supervisor
WEBSITE
W W W.STLUCIECO.GOV
ORANGE A V ENS BAPTIST CHURCH
ORANGE AVENUE BAPTIST SCHOOL
MAILING ADDRESS CONTACT
100 Cyclone Drive Phone: 772.461.1225
Fort Pierce, Fl. 34945 Fax: 772.461,0605
April 9, 2019
Ms. Leslie Olson
Director
St. Lucie County Planning & Development
2300 Virginia Avenue
Fort Pierce, Florida 34982
RE: Orange Avenue Baptist Church Basketball Pavilion
Permit #1903-0373
Dear Leslie:
Please accept this letter requesting relief from the St. Lucie County Development Code chapter
7.04.01 finished floor requirement. In that code the finished floor elevation is required to be
18" above the crown of the road. This proposed basketball pavilion is one of several existing
structures on the site, all of which have existing finished floor elevations that are the same. The
existing buildings do not meet the current County's code requirement. The crown of the road is
at elevation 23.28' thus requiring the building finished floor elevation to be 14.78'. We are
proposing to construct the basketball pavilion matching the other existing structures at a
finished floor elevation of 24.05'.
We thank you in advance for your time and consideration.
Sincerely,
Laurence Ivey
Director
Orange Avenue Baptist Church, Inc.
Planning & Development
Servkes
APR 17 2019
RECEIVED
Lydia Galbraith
From: Roger Priest <rpriest@rkdavis.com>
Sent: Monday, March 25, 2019 1:39 PM
To: Lydia Galbraith
Subject: Orange Avenue Baptist Basketball Court - Permit 1903-0373
Lydia,
May we ask a question of clarification before we set off to create a response to a Zoning Review Comment?
For the Open Basketball Pavilion we do not have any exterior lighting shown on the plan. We do have interior lighting,
however, understand that there are only partial walls on this proposed building. So, does the comment "the conditions
of approval number 1 in PDS order 17-202 requires "the exterior lighting that is provided for the covered playground
area shall be shielded with zero footcandle readings at adjacent property lines" pertain to lighting within the building or
jus x riot iightirr lighting intended to light the area surrounding the building? All lighting within the building will be
s ie a rom ie neighboring properties by the skirt wall panels that will surround the building. That skirt wall
combined with the fact that this building sits 100' away from any property line should be enough assurance that no light
will spill over into neighboring properties.
Roger A Priest T
Richard,K•.Oavis-Copstruction Carp_
P. O3 Box 9 6 *
Fort Pierce. ",Florida -34954
(772) t61-83,5 _.._I
E-mail rpriest@rkdavis pirm
J
Lydia Galbraith
From: Linda Pendarvis
Sent: Tuesday, March 19, 2019 8:23 AM
To: Lydia Galbraith
Subject: RE: Orange Ave Baptist Church play ground, 1903-0373
Attachments: Warranty Deed and Res. 2017-152.pdf, Recorded Revocable License Agreement.pdf
Lydia
Based on the documents attached that satisfied conditions of approval for this project the project is vested and is not
expired.
Thank you.
z
Linda Pendarvis
Planning Division
Planning & Development Services
(772) 462-1562
2300 Virginia Ave
Fort Pierce, FL 34982
St. Lucie County Planning Division is committed to great service and your feedback is vital.
Please take our short survey to let us know how we're doing.
http://www.stlucieco.gov/planning/SLCP]anningSurveV.htm
From: Lydia Galbraith
Sent: Monday, March 18, 2019 4:27 PM
To: Linda Pendarvis <pendarvisl@stlucieco.org>
Subject: Orange Ave Baptist Church playground, 1903-0373
Hi Linda,
I have a permit in for a 10,000 covered playground for above site plan. The playground was approved but the PDS order
has an expiration date of 5/3/18. 1 have checked the GM Data base and the files under Group -Planning but couldn't find
a request for an extension. Are there any other places where an extension request could be filed?
Thank you,
Lydia C5aCbraith,
Zoning Specialist
Building and Code Regulation
(772) 462-1555
galbra ithl@stlucieco.org
ea?s�sT
p aces
,ow t$•
aT. I.UGY@ C6UNTY
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and 1
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection. examination and
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error;
please notify the sender by reply e-mail and delete all materials from all computers.
.. App R�C�pFo
1
es 1etio 71p19
F C4 P�epB
C��Ofy eft
April 5, 2019
Plans Review Agent
Jpi, Inc. - Andrew
St. Lucie County Building Dept.
2300 Virginia Avenue
Fort Pierce, FL 34982
Re ljtci dflC#' 1903 03]3- Orange Avenue Baptist Church Basketball Pavilion
Dear Andrew:
The following answers to your plans review comments are offered for the project referenced above:
Plans Examiner Review:
1) S-2, Structural notes reference the 2014 FBC. Note has been corrected
2) Please fix the conflict between notes on sheet A-2 `Building Code Data Applied to this Project"
and sheet S-2 "Certification for Design Load Compliance." Notes have been corrected
3) Please update the construction type or provide the protection to achieve the 1-hour fire resistant
rating for Type V-A construction (Table 601). The Construction Type has been revised to Type V-
B.
4) The metal building shop drawings have not been submitted. Please submit three original sets,
reviewed and approved by the engineer of record. Acknowledged.
5) Please see Sections (F-907.2 and F-907.2.3) for Fire Alarm requirements. A note has been added
to the drawings indicated compliance to the Florida Building Code sections 907.2 and 907.2.3.
Zoning Review:
1) The conditions of approval number 1 in PDS order 17-020 requires "the exterior lighting that is
provided for the covered playground area shall be shielded with zero footcandle readings at the
adjacent property lines." Please provide the type of lighting, how they are going to be shielded
and provide a photometric plan based on the type of lights. Light type and photometrics are
forthcoming.
2) The enclosed restroom area is required to meet 18" (24.78') above the crown of the adjacent road.
Highest point in front of the building is 23.28'. Only the restrooms will need to be 18". The open
areas do not have that requirement. Please indicate on the site plan the area of the enclosed
restrooms +FFE. Please see letter from owner requesting a variance from this requirement. This
proposed structure and all existing structures on -site shall be at the same finished floor elevation.
3) Approved storm water permit is required. See attached e-mail and letter from water quality.
Acknowledged
4) The drain field should be on the property of the Church and not on the neighbor's property. The
two properties will need to be combined with Unity of Title or the drain field will need to be
relocated to the Church property. A Unity of Title shall be executed by the owner.
5) . Stormwater permit is pending. Acknowledged
Thank you for your comments. Please feel free to contact us should there be further comments or needs for
additional information.
a' I �'Velc}
Pa alchIne"
Engineer of Record
PAUL WELCH INC.
MECH-ELECT-CIVIL ENG.
1984 BILTMORE ST. #114
PORT SAINT LUCIE, FL 34984
PAUL WELCH P.E.
FLA REG NO 29945
nec&vEo
APR l 71819
Permitting D
St. luc,e COenty ent
April 5, 2019
Plans Review Agent
Jpi, Inc. - Andrew
St. Lucie County Building Dept.
2300 Virginia Avenue
Fort Pierce, FL 34982
Re: 'P rmrt #g1903_0_ 3 Orange Avenue Baptist Church Basketball Pavilion
Dear Andrew:
The following answers to your plans review comments are offered for the project referenced above:
Plans Examiner Review:
1) S-2, Structural notes reference the 2014 FBC. Note has been corrected
2) Please fix the conflict between notes on sheet A-2 `Building Code Data Applied to this Project"
and sheet S-2 "Certification for Design Load Compliance." Notes have been corrected
3) Please update the construction type or provide the protection to achieve the 1-hour fire resistant
rating for Type V-A construction (Table 601). The Construction Type has been revised to Type V-
B.
4) The metal building shop drawings have not been submitted. Please submit three original sets,
reviewed and approved by the engineer of record. Acknowledged
5) Please see Sections (F-907.2 and F-907.23) for Fire Alarm requirements. A note has been added
to the drawings indicated compliance to the Florida Building Code sections 907.2 and 907.2.3.
Zoning Review:
1) The conditions of approval number 1 in PDS order 17-020 requires "the exterior lighting that is
provided for the covered playground area shall be shielded with zero footcandle readings at the
adjacent property lines." Please provide the type of lighting, how they are going to be shielded
and provide a photometric plan based on the type of lights. Light type and photometrics are
forthcoming.
2) The enclosed restroom area is required to meet 18" (24.78') above the crown of the adjacent road.
Highest point in front of the building is 23.28'. Only the restrooms will need to be 18". The open
areas do not have that requirement. Please indicate on the site plan the area of the enclosed
restrooms +FFE. Please see letter from owner requesting a variance from this requirement. This
proposed structure and all existing structures on -site shall be at the same finished floor elevation.
3) Approved storm water permit is required. See attached e-mail and letter from water quality.
Acknowledged.
4) The drain field should be on the property of the Church and not on the neighbor's property. The
two properties will need to be combined with Unity of Title or the drain field will need to be
relocated to the Church property. A Unity of Title shall be executed by the owner.
5) . Stormwater permit is pending. Acknowledged
Thank you for your comments. Please feel free to contact us should there be further comments or needs for
additional information.
tMelch
Pa
h, Inc.
Engineer of Record
PAUL WELCH INC.
MECH-ELECT-CIVIL ENG.
1984 BILTMORE ST. #114
PORT SAINT LUCIE, FL 34984
PAUL WELCH P.E.
FLA REG NO.29945
PAUL WELCHIMC
MECHANICAL ELECTRICAL CIVIL ENGINEERING
1994S.W.. B/LTMORESr. Surr--&l 14
PORT SAINT LOcm; FL 34984
(772) 785-988$ PWELCHINC@AOL COM
PAIIL WELCH, P.E. FLALICNO. 2.9945
June 3, 2019 Receweo
jUNO r, g019
Plans Review Agent perMtt�a9 Counbl ne
Jpi, Inc. - Andrew St, Lucie
St. Lucie County Building Dept.
2300 Virginia Avenue
Fort Pierce, FL 34982
Re: Permit # 1903-0373 — Orange Avenue Baptist Church Basketball Pavilion
Dear Andrew:
The following answers to your plans review comments are offered for the project referenced above:
Plans Examiner Review:
1) The revised A-2 sheet came in with the corrected construction type. Sheet S-2 will also need to be
corrected for construction type. Sheet S-2 has been corrected as to construction type.
2) We are waiting on the Metal Building Drawings to complete the review. Sign and sealed metal
building erection shop drawings are attached to this plans review response along with our local
engineer's review and approval.
Additional Plans Revisions:
1) Drawing page A-1 and S-1 have beenrevised to coordinate with the metal building manufacturer's
frame designs and reactions. Foundation sizes have been adjusted. Restroom door locations have
been adjusted to avoid the tapered metal building column.
Thank you for your comments. Please feel free to contact us should there be further comments or needs for
additional info ation.
Sincerely,
Paul Welch
Paul Welch, Inc.
Engineer of Record
PAUL WELCHBVC
NECHAN/CAL E'LEC7NICAL CML ENG/NEWUNG
19645.W BILTMORESr. SUHE#114
PomrSAINTLUC/E, FL34984
tr70 785-9888 PWEL CH1NC@AOL COM
PAUL WELCH, P.E. FL4LtCNO.29945
June 3, 2019
Plans Review Agent
Jpi, Inc. - Andrew
St. Lucie County Building Dept.
2300 Virginia Avenue
Fort Pierce, FL 34982
Re: Permit# 1903-0373 — Orange Avenue Baptist Church Basketball Pavilion
Dear Andrew:
The following answers to your plans review comments are offered for the project referenced above:
Plans Examiner Review:
1) The revised A-2 sheet came in with the corrected construction type. Sheet S-2 will also need to be
corrected for construction type. Sheet S-2 has been corrected as to construction type.
2) We are waiting on the Metal Building Drawings to complete the review. Sign and sealed metal
building erection shop drawings are attached to this plans review response along with our local
engineer's review and approval.
Additional Plans Revisions:
1) Drawing page A-1 and S-1 have been revised to coordinate with the metal building manufacturer's
frame designs and reactions. Foundation sizes have been adjusted. Restroom door locations have
been adjusted to avoid the tapered metal building column.
Thank you for your comments. Please feel free to contact us should there be further comments or needs for
additional info atiop.
Sincerely,
Paul Welch
Paul Welch, Inc.
Engineer of Record
April 5, 2019
Plans Review Agent
Jpi, Inc. - Andrew
St. Lucie County Building Dept.
2300 Virginia Avenue
Fort Pierce, FL 34982
Re: Permit # 1903-0373 — Orange Avenue Baptist Church Basketball Pavilion
Dear Andrew:
The following answers to your plans review comments are offered for the project referenced above:
Plans Examiner Review:
1) S-2, Structural notes reference the 2014 FBC. Note has been corrected
2) Please fix the conflict between notes on sheet A-2 "Building Code Data Applied to this Project"
and sheet S-2 "Certification for Design Load Compliance." Notes have been corrected.
3) Please update the construction type or provide the protection to achieve the 1-hour fire resistant
rating for Type V-A construction (Table 601). The Construction Type has been revised to Type 1/
B.
4) The metal building shop drawings have not been submitted. Please submit three original sets,
reviewed and approved by the engineer of record. Acknowledged.
5) Please see Sections (F-907.2 and F-907.2.3) for Fire Alarm requirements. A note has been added
to the drawings indicated compliance to the Florida Building Code sections 907.2 and 907.2.3.
Zoning Review:
1) The conditions of approval number 1 in PDS order 17-020 requires "the exterior lighting that is
provided for the covered playgroundarea shall be shielded with zero footcandle readings at the
adjacent property lines." Please provide the type of lighting, how they are going to be shielded
and provide a photometric plan based on the type of lights. Light type and photometrics are
forthcoming.
2) The enclosed restroom area is required to meet 18" (24.78') above the crown of the adjacent road.
Highest point in front of the building is 23.28'. Only the restrooms will need to be 18". The open
areas do not have that requirement. Please indicate on the site plan the area of the enclosed
restrooms +FFE. Please see letter from owner requesting a variance from this requirement. This
proposed structure and all existing structures on -site shall be at the same finished floor elevation.
3) Approved storm water permit is required. See attached e-mail and letter from water quality.
Acknowledged.
4) The drain field should be on the property of the Church and not on the neighbor's property. The
two properties will need to be combined with Unity of Title or the drain field will need to be
relocated to the Church property. A Unity of Title shall be executed by the owner.
5) . Stormwater permit is pending. Acknowledged
Planning & Development
Services
APR 17 2019
RECEIVED
Thank you for your comments. Please feel free to contact us should there be further comments or needs for
additional information.
Si re ,
au Welch
Paul Welch, Inc.
Engineer of Record
PAUL WELCH NC
MECH ELECT-C VIL ENG.
PORT SAINT LUC E, FL 349a4
PALL WELCH P.E.
FLA REG NO.29945
r�
Planning and` Development
Services Department
Planning Division
MEMORANDUM
TO: DAVID HAYS, ENGINEERING
FROM: LYDIA GALBRAITH, BUILDING & CODE DIVISION
DATE: March 26, 2019
SUBJECT: Orange Ave Baptist Church covered playground, building permit 1903-0373
Please review attached civil drawings for above site plan. Permit is for a covered playground
approved per site plan and PDS order 17-020.
Lydia Galbraith
From:
Jodi Nentwick
Sent:
Tuesday, June 18, 2019 1:30 PM
To:
Lydia Galbraith
Cc:
Linda Pendarvis
Subject:
RE: Orange Avenue Baptist Church - Basketball Pavilion - PHOTOMETRICS, bid permit
%T503YON,31.
Lydia,
This has been approved and updated in the building permit review.
Jodi Nentwick
Sr. Planner
Planning and Development Services
2300 Virginia Avenue
Ft. Pierce. FL 34982
(772) 462-1580
nentwickiCd.)slucieco.org
www.stlucieco.orq
T, LSE
BfS1
t e i plats
% 1111Qf ri- +, .
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and I
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
From: Lydia Galbraith
Sent: Tuesday, June 18, 2019 10:59 AM
To: Jodi Nentwick <NentwickJ@stlucieco.org>
Cc: Linda Pendarvis <pendarvisl@stlucieco.org>
Subject: FW: Orange Avenue Baptist Church - Basketball Pavilion - PHOTOMETRICS, bid permit 1903-0373
Jodi,
Please review attached photometric for the basketball pavilion of Orange Ave Baptist Church. It was a condition of
approval. Please let me know if they are meeting so I can sign off on the comment.
Thank you,
Lydia CgaCbraith,
Zoning Specialist
1903 --0:! p
Lydia Galbraith
From: Roger Priest <rpriest@rkdavis.com>
Sent: Monday, June 17, 2019 10:20 AM
To: Lydia Galbraith
Subject: Orange Avenue Baptist Church - Basketball Pavilion - PHOTOMETRICS
Attachments: Orange Avenue Baptist Church - INTERIOR PHOTO M ETRICS.pdf, Orange Avenue Baptist
Church - EXTERIOR PHOTO METRICS.pdf
Lydia,
RE: Orange Avenue Baptist Church — Photometrics
Permit 1903-0373
In response to the Planning Review comment: The conditions of approval number 1 in PDS Order 17-020 requires "the
exterior lighting that is provided for the covered playground area shall be shielded with zero footcandle readings at
adjacent property lines." Please provide the type of lighting, how they are going to be shielded and provide a
photometric plan based on the type of lights. Attached please find the light fixture proposed for this building along with
interior photometrics. Additionally, we have prepared exterior photometrics 25' beyond the building's structural
line. The light levels at 25' outside of the building are less than 1 footcandle. Note that the closest property line is 100'
away from the structural line of this building!