HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Projec} Name: PURSUIT BOATS COMPRESSOR SHELTER
Project Address: 3901 ST. LUCIE BLVD.
Permit #: Occupancy Type:
INSTRUCTIONS FOR USE •
Construction Type:
V
SCANNED
BY
St. Lucie County
• This certification must be completed, signed,, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or mufti -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that a
1. DESIGN CODE: Florida Building Code 2017 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): _ Enclosed X Partially Enclosed _ Open
3. Risk Category: _ I X II_ Ill_ IV Exposure Category: _ B X C_ D
4. Design Wind Velocity 160 -mph 124 ASD N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 11.6 ft Roof Pitch: 0.4 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based bn 10sgft @ 1VMRH, dearly label on all plan openings):
24.2 24.2 24.2 44.1 44.1 N/A
Zone is -44.1 Zone 2: -66.8 Zone 3: _95.3 Zone 4: -46.9 Zone 5: _55.5 Garage: N/A
7. Design Loads: Floor: 100 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF
Dods: N/A PSF Deck: _ N/A_ PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF /"CONCENTRATED
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X yes. _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSFSoil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plansl specifications have been designed to
comply w the applicable structural portions of the building ;odes currently adopted and enforced by St. Lucie
County. I a certify that structural elements depicted on these plans provide adequate resistance to the design
Paul Welch P.E. 29945 / 5115
Print Name - Cert# & Co. CertAuth.,
Paul Welch Inc.
Signature, qi:e, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL
COPY
C
G
Company Name&Address FI L
SLCLUV Form n p21F12 Renseo 3/1S/12 (!5) - ' I. �✓