Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Projec} Name: PURSUIT BOATS COMPRESSOR SHELTER Project Address: 3901 ST. LUCIE BLVD. Permit #: Occupancy Type: INSTRUCTIONS FOR USE • Construction Type: V SCANNED BY St. Lucie County • This certification must be completed, signed,, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or mufti -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that a 1. DESIGN CODE: Florida Building Code 2017 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): _ Enclosed X Partially Enclosed _ Open 3. Risk Category: _ I X II_ Ill_ IV Exposure Category: _ B X C_ D 4. Design Wind Velocity 160 -mph 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 11.6 ft Roof Pitch: 0.4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based bn 10sgft @ 1VMRH, dearly label on all plan openings): 24.2 24.2 24.2 44.1 44.1 N/A Zone is -44.1 Zone 2: -66.8 Zone 3: _95.3 Zone 4: -46.9 Zone 5: _55.5 Garage: N/A 7. Design Loads: Floor: 100 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF Dods: N/A PSF Deck: _ N/A_ PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF /"CONCENTRATED 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X yes. _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSFSoil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plansl specifications have been designed to comply w the applicable structural portions of the building ;odes currently adopted and enforced by St. Lucie County. I a certify that structural elements depicted on these plans provide adequate resistance to the design Paul Welch P.E. 29945 / 5115 Print Name - Cert# & Co. CertAuth., Paul Welch Inc. Signature, qi:e, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL COPY C G Company Name&Address FI L SLCLUV Form n p21F12 Renseo 3/1S/12 (!5) - ' I. �✓