HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSSCANNED
BY
St. Lucie County
South
GJGO VKBtlunuuuw ofvu, Yvebi fUIm o@VOn, M OJ9VY • °OI-/ IZ-YVW • l KU IJJUOLL
R�cCF�'FO
AP,p o
Per'/a/ o �1p�e
CO60ty e0C
Property Information Building Information
Owner: DOUGLAS & ROBERTA EGER Wind Zone: 170 MPH.
Address: 23 LAKE VISTA TRAIL #105 Exposure Category: C
PORT ST. LUCIE, FL 34952 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
Risk Category: B
Design
Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft) _
Max Positive
Pressure (psf) _
Max Negative
Pressure (psf)
1
hit
36
49.50 7
37.3
-40.5
2
Ent
36
49.50 7
37.3
-40.5
3
hit
52
49.50 7
36.4
-39.6
4
hit
35.75
37 7
37.8
-41.0
5
hit
52
37 7
37.1
-40.3
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (N]7) Florida Building.Code.