HomeMy WebLinkAboutPRODUCT APPROVAL4/4/2019 Florida Building Code Online
BUS Home i Leg In User Registration I Hot Tapl6 I submit Surdiarge i Stats & Facts i Publications i Contact Us I acts Site Map I Links I Search
ik, "� 'Product Approval
i
$�—� USER: Public User
`-4 'Zr:
'rSA:SS.tr.R[RY2t Ng� > ProR11:LRCARRIS?StP.n3eaa;7! > AR9L42[LGa.LLSt > Application Detall
FL F
FL389-R9
Application Type
Revision
SCq
Code Version
2017
' i 'Vl
Approved `D
Application Status
St C(%Qf�
County
Comments
Archived
^1
Product Manufacturer
American Shutter Systems Association, Inc.
Address/Phone/Email
4268 Westroads Drive
West Palm Beach, FL 33407
(561)209-8263
bfeeley@easternmetal.com
Authorized Signature
Bill Feeley
lrodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
+7 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A.. Tillit, Jr. P.E.
Evaluation Report
Florida License
PE-44167
Quality .Assurance Entity
National Accreditation and Management Institute
-Quality Assurance Contract Expiration Date
12/31/2019
Validated By
John Henry Kampmann Jr.
'M Validation Checklist - Hardcopy Received
Certificate of Independence FL389 R9
COI AMERICAN
SHUTTER SYSTEM
ASSOC., TNC. DRAWING 17-
107 CERTIFICATE
OF INDEPENDENCE.PDF
FL389 R9
COI AMERICAN
SHUTTER SYSTEMS
ASSOC.. INC. DRAWING
17-106
CERTIFICATION
OF INDEPENDENCE
(1) P� DF
FL389 R9
COI AMERICAN
SHUTTER SYSTEMS
DRAWING 17-108
CERTIFICATE
OF INDEPENDENCE.PDF
Referenced Standard and Year (of Standard) Standard
Year
ASTM E-1886
2005
ASTM E-1996
2005
ASTM E-330
2002
TAS 201, 202, 203
REVIEWED FOR
Equivalence of Product Standards
CODE COMPLIANCE
Certified By
ST. LUCIE COUNTY
httpslifloridabuilding.orgipripr app_dti.aspx?param=wGEVXOwtDgvYYHH2vJv 53MwsXdCOtOXQsoPMYK7UC8%3BOCC
1/3
4/4/2019
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/18/2017
Date Validated 10/18/2017
Date Pending FBC Approval 10/19/2017
Date Approved 12/12/2017
FL # Model, Number or Name Description
389.1 Bertha HV Accordion Shutter - Blade Extruded aluminum interlocking blades retained by [racks (top
3 - (Non-HVHZ) - Drwg 17-108 and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D".Max span is 12'-3" for 40 psf
positive ASD load and 13'-0" for 35 psf negative ASD load the
HV3 blade w/o window blade,5'-2" for 110 psf ASD load for HV3
blade w/o window blade and W-11" for 62 psf, 9' 11" for 55 psf
HV3 blade w/window blade working in unison.Max.span for HV3
blade w/o window blade for Installations into Metal Stud walls is
79" for max. ASD pressure rating of +72,-72 and 84" for
+64,-64 psf. See sheet 5 for other spans and ASD pressures.
Installation Instructions
FL389 R9 II AI R1 AN SHUTTER SAS—EM __u{iAt�rINCi17-
108 BERTHA HV AC_CORDION SHUTTER SY>TEM.,PDF
Verified By: American Test Lab of South F :OI'Ida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEMS _GRAINING 17-
108 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
389.2 I Bertha HV Accordion Shutter -Blade 1 Extruded aluminum interlocking blades retained by tracks (top
Only- (Non-HVHZ)- Drwg 17-107 and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. Span is 16'-0" for 30 p.s.f
negative ASD load depending on centermates and locking rod
configuration for the HV3 blade, 8'-0" for +64, -72 p.s.f. A.S.D.
load for HV blade for Keystone mountings T-0" p.s.f. for metals
stud mountings and 6'-0" for 110 p.s.f. for HV1A working in
unison. See sheets 7, IS and 20 respectively of Installation
drawings for other spans and pressures.
Installation Instructions
FL389 R9 11 AMERICAN SHUTTER SYSTEM SSS�_
INC. DRAWING 17-107 BERTHA HV ACCORDION SHUTTER
SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 P.9 AE AMERICAN SHUTTER SYSTEr6 A65QC,.
INC. DRAWING 17-1,07 PRODl1TT OF EVALUATTOly
REPORT.PDF
Created by Independent Third Party: Yes
389.3 Bertha HV Accordion Shutter- I Extruded aluminum interlocking blades retained by tracks (top
COMBO- (Non-HVHZ)- Drwg 17-106 1 and bottom) for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL389 R9 11 AMERICAN SHUTTER SYSTEMS ASSQ1
Approved for use outside HVHZ: Yes PIP L iNG 17-j,QC,�ERzjj(LFjV ACC 1�tQ(-Q1y_Si;(f�=[J
Impact Resistant: Yes SYST.PDF
Design Pressure: N/A Verified By: American Test Lab of South Florida Inc.
Other: large missile. Max. 16'-0" span at 30 p.s.f ASD load for Created by Independent Third Party: Yes
Blade 1 and 18'-O" for Blade 2. See schedules on sheet 12, 25 Evaluation Reports
and 28 respectively FL389 R4 AE_6ME12ICAN SFWUER SYSTLIA SgSjs
DRAWING 17-106 PRODUCT EVALUATION RrPOO T.
Created by Independent Third Party: Yes
ttaok next
Contact ❑s :: 2601 Blair Stone Road. Tallahassee FL 32399 ape: 850-487,1824
The State of Flonda Is an AA/EEO employer. CopvJgh[ 200J-2013 state of Fleritla.:: Pdvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. It you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the ofnce by phone or by traditional mail. Ifyou have any questions, please contact 850.487.1355. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click M1 g.
product Approval Accepts:
EN ER EM
hffps://floridabuilding.org/prlpr_app_ U.aspx?param=wGEVXQvADgvYYHH2vJvx53MwsXdCOtOXQsoPMYK7UC8°/p3d 2/3