Loading...
HomeMy WebLinkAboutFORM H-2FORM H-2 MANUFACTURER'S DATA REPORT FOR ALL TYPES OF BOILERS Page 1 of 2 EXCEPT WATERTUBE AND THOSE MADE OF CAST IRON As Required by the Provisions of the ASME Code Rules, Section IV 1. Manufactured and certified by Botiersmilh Ltd., 156 Main Street south. Sealorth. Ontario, NOK 1WO, Canada (name and address of manuraclurer) . Manufactured for MacDonald Steel Ltd., 200 Avenue Road, Cambridge, Ontario, N1R BHS, Canada (name and address of purchaser) Islamorada Distilling LLC, 3259 St. Lucie Blvd, Unit A, Fort Pierce, Florida, 34946 3. Location of installation name and a ess 4. Unit identification Com late Boiler 53004 M9846.512467890 EL-1623 270 2018 comp e e i er, supe eater, (man acture s serial no.)�CRA� rawmg no. a Iona . no. ear ui waterwill, economizer, eta) 5. The chemical and physical properties of a0 parts meet the requiremen(s of material speciriations of the ASME BOILER AND PRESSURE VESSEL CODE. The design, construction andworkmarishlp conform to ASME Code, Section IV, 2017 NIA , ear a a as app is e a e a cam no. Manufacturer's Par0al Data Reports propedy identified and signed by Commissioned Inspectors have been furnished for the fo0ovring items of this report (name of pan, Item number, manufacturers name, and identifying stamp) 6. Shells or drums 1 SA-211,C 0.375 in 3' 8" x 5' 7.375" 7' 3.5" NIA na matena spec, gr.) i ess msi a lame er eng oven msi a came r NIA en9t ovem IUF 7. Joints Seamless NIA Seamless 1 ng, sea ess, weidedil —raTwinwaita to seamless)] sea ass, We ) no. of Shell courses 8. Tubesheet SA-285-C 0.375 Tube holes 94.2.03" (material spec, grade) (Odckness) (numberanddiameter) 9. Tubes: No. 94 SA-178-A Straight Diameter 2.r Length 66S" 88.25" Gauge 13 rrat spea, g. a sbalg or 0f vanous, give max. ano mm. or thickness) 10. Heads SA-265-C 0.375" FLAT NIA (maderial spec, no. ( ess) (flat. dished, ellipsoidal) (radius of dish) SA-285-C 0.375" 1 35"x29.75" 66.125" 1 lain Seams 11.Fum--[� aR �az>area emn seamless seam ass, we nc ace mawW—pp—,ass sce .or z se im .12.Stayboits 32 1" SA-36 0.111" 0.023 si 0.757 st 11.75" 11.25" 15 si na srze lame 0 mate spea, gr, size (tell a (net area itrwnzon an verea J. Stan or braces: Material Spec Type Numberand Size Pitch TotalNet Fig.HG-'43 LA Dist Tubes to Shell MAWP Location (a) F.H. above tubes NIA (b) R.H. above tubes NIA (c) F.H. belowtubes jSA6jThrg1gh7,1" WA (d) R.H. belowtibes 11.75" 5.299 si 14A" 15 psi (e)Throughstays HIA 14. Other pads: 1. Shell to Shell Slays 2. Door Ring 3. NIA (boat description, i.e. dome, boiler piping) 1. SA361"diameter 4575"long 30 os1 2. SA-10&B 16" pipe, standard 30 psi 3. NIA (matedal spec, grade, size, material thickness. MAWP) 15. Nozzles, inspection and safety valve openings: Purpose(nlet duffel. drain, etc. No. Diameleror Size Type How Attached Material hidcness Reinforcement Material Location Handhole 8 325"x4.5" NA Bolted NA FH, RH, SHELL Manhole 0 supply Conn. 1 61n. Pipe Welded SA-106-B STD Integral Shell Return Conn. 1 2.5 in. CPI Welded SA-105 Class 30001ntegral RH DrainlBlowoN 1 1.51n. Cpl Welded SA-105 Class 30001ntegral RH Safety Valve 2 2S in. CPI Welded SA-105 Class 3000 Integral I Shell SCANNED BY St. Lucie County PKEY 3213731 exe: v6.3.35 FORM H-2 I Paget oft Manufactured by Boilersmith Ltd., 156 Alain Street South Seafodh, Ontario, NOK 1WO, Canada Mfrs Serial No, 53004 National Board No, 270 16. Boger supports 2 Lees Welded (no.) INPe(saddlee,legs, lugs)) [attachment(bolted or welded)) 17. MAWP 15 psi Based on H0,340 Heating surface 358 so-f . Shop hydro. lest 60 osl (Codepacandfor(annula) (total) (wmpletebaler) 18.Maumumwaterlemperahue 25VF 19. Remarks Minimum Required Relieving Capacity 3289 lb/hr CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made In this data report are comectand that all details of design, material, construction, and workmanship of this boiler conform to Section IV of the ASME BOILER AND PRESSURE VESSEL CODE 'H' Certificate of Authorization no. 22029 expires July 1D 2020 Date 11/21/2018 Signed Name Boilersmith Ltd. 11hy1reptegiflative) (manufacturer that constructed and certified Dollar) CERTIFICATE OF SHOP INSPECTION Boger constructed by Boilersmith Ltd. at 156 Main Steel South Seaforth Ontario NOK 1WO, Canada 1, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and employed by TSSA have inspected parts of this boiler referred to as data items 1-19 and have examined Manufacturers' Partial Data Reports for items and state that, to the best of my knowledge and belief, the manufacturer has Constructed this boiler in accordance with the applicable sections of the ASME BOILER AND PRESSURE VESSEL CODE. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the boiler described in this Manufacturer's Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from „r ire—� roman iah rhi� le�r,Anl.,r, Date 111211201B Signed ]_,.,�.---� Commission: 13918, ONT155349 Authonzedlnspe or (National Board Authored lnspectorCommission Number) CERTIFICATE OF FIELD ASSEMBLY COMPLIANCE We certify that the field assembly construction of all parts of Nis boiler conforms with the requirements of SECTION IV of the ASME BOILER AND PRESSURE VESSEL CODE, 'H'CeNficateofAuNorizationno. expires Date Signed Name (by representative) (assembler that certified and constructed field assembly) CERTIFICATE OF FIELD ASSEMBLY INSPECTION I, the undersigned, holding a valid commission Issued by The National Board of Boiler and Pressure Vessel Inspectors and employed by have compared the statements In this Manufacturer's Data Report with the described boiler and state that the parts referred to as data items , not included in the certificate of shop inspection, have been inspected by me and that to the best of my knowledge and belief, the manufacturer and/or the assembler has constructed and assembled this boiler In accordance with the applicable sections of the ASME BOILER AND PRESSURE VESSEL CODE. The described boiler was inspected and subjected to a hydrostatic test of By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the boiler described in this Manufacturer's Data Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Dale Signed Commission (Authorized Inspector) (National Board Authorized Inspector Commission Number) F"aI1d YElS%L M-13 PKEY 3213731 axe: v6.3.35