HomeMy WebLinkAboutMISC LETTERArchitectonic Inc St Lucie County Building Department Plan Review Division May 31, 2019 RE: 3171 Morning Dew lane Building 21 Permit # 1904-0518 To Whom it May Concern: SCANNED BY St. Lucie County RECEIVED JUN 0 3 2019 ST. Lucie County, Permitting Please accept the following responses to the comments dated 5/16/2019 from your agency. Response shown on plans corresponding (if required) to these comments are noted with revision clouds. 1. Provide Mechanical ventilation calculations for the meeting room based on 46 occupants not 22. GS. DWG. M-2 Response: Meeting room occupancy is correct at 16.5 People. Meeting room is 330 sq. ft.; FBC Mechanical Table 403.3.1.1 meeting room occupancy is 50 people per 1000 sq. ft. (.330 x 50 =16.5 People not 46 People 2. Provide corrected HVAC load analysis for the occupant count and room names. GS. DWG. M-2. . Response: Occupancy for ventilation and load calculation shall remain unchanged; HVAC load analysis shall remain unchanged. 3. Waiting for updated occupant load. Response: Occupant load is correct based on the following responses and dose not require updating. 4. occupancy load count is incomplete, please see section Chapter 10, Section 1004, and definitions for area, building. Exterior porches and restroom were not included within the horizontal projection of the roof or floor above. Response: Per the definitions from the Florida Building Code toilet rooms are not occupied spaces and the entry porches are not a room or enclosed space designed for human occupancy. Definitions: Floor Are Net: The actual occupied area not including unoccupied accessory area's such as corridors, stairways, ramps, toilet rooms, mechanical rooms and closets. Occupant Load: The number of persons for which the means of egress of a building is designed. Occupiable Space: A room or enclosed space designed for human occupants in which individuals congregate for amusement, educational or similar purposes on in which are engaged at labor and which is equipped with means of egress and light and ventilation facilities meeting the requirements of this code. Tel: 7724607751 www.architectonicinc.com Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 Architectonic Inc 9�ecevso St Lucie County SUN 131019 BuildPlanRev ew D v s onDepartment percr Ili^9 Pa ncvent June 12, 2019 RE: 3171 Morning Dew lane Building 21 Permit # 1904-0518 To Whom it May Concern Please accept the following responses to the comments dated 5/16/2019 from your agency. Response shown on plans corresponding (if required) to these comments are noted with revision clouds. 1. Provide Mechanical ventilation calculations for the meeting room based on 46 occupants not 22. GS. DWG. M-2 Response: See revised mechanical plans showing 22 occupants 2. Provide corrected HVAC load analysis for the occupant count and room names. GS. DWG. M-2. . Response: See revised load calculations. I�..........:�q`F a�^ Inc. PR96�9 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 Architectonic Inc St Lucie County Building Department Plan Review Division June 12, 2019 RE: 3171 Morning Dew lane Building 21 Permit # 1904-0518 To Whom it May Concern: Please accept the following responses to the comments dated 5/16/2019 from your agency. Response shown on plans corresponding (if required) to these comments are noted with revision clouds. 1. Provide Mechanical ventilation calculations for the meeting room based on 46 occupants not 22. GS. DWG. M-2 Response: See revised mechanical plans showing 22 occupants 2. Provide corrected HVAC load analysis for the occupant count and room names. GS. DWG. M-2. . Response: See revised load calculations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 I ♦ / Mike Halter From: Lynn Swartzel Sent: Monday, March 16, 2020 4:22 PM To: Mike Halter Cc: Amy Griffin; Jennifer McGee; Jill Arnold Subject: 1904-0518 Mike, I spoke with Amy and she said will allow them to transfer the landscape inspection to the pool permit. Thank you, Lynn�- Lynn A. Swartzel I Environmental Regulations Specialist f �f Ph: 772-462-6423 1 Fax: 772-462-1684 12300 Virginia Ave. Fort Pierce 34982 Poo ( 20C (— 0 03Y facebook-com/stluciegov I twitter.com/stluciegov I instagram.com/stluciegov I youtube.com/stluciegov 2016 ..SST 4 pares 7' SF.4t�tS Cf1UNiY Sf.c l Se at Ba�x6arCan¢gCeamY�uaaen Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error. please notify the sender by reply e-mail and delete all materials from all computers. CULPEPPER & TERPENING, INC. CONSULTING ENGINEERS '.. LAND SURVEYORS C&T Project \o.:15-051 File: SLC ENG Sender's Email• scum 's n c -en .yom September 12, 2019 VIA: Hand Delivery Mr. David Hays, P.E, CFM Senior Project Engineer St. Lucie County Water Quality Division St. Lucie County 2300 Virginia Avenue Ft. Pierce, n 34982 RE: Sedona PUD — Phase 1 Construction St. Lucie County Stormwater Permit No. 17-02 Engineer's Partial Certification — Southern Portion of Project Dear Mr. Bays: This is to certify that the requited infrastructure improvements for the southern portion of the Sedona PUD Phase 1' project have been completed in substantial conformance with the approved construction plans and specifications. The completed portion includes the entire stormwater system, detention pond and outfall, and paving and drainage infrastructure associated with Buildings 13, 14, 15, 16, 18, 19 and 20. The only minor deviation for the partial certification are as follows: • Minor changes in final grade, and invert elevations for the project These deviation does not affect the paving and drainage improvements of the site which are completed in substantial accordance with the approved Construction Plans. As always, should you have any questions, please do not hesitate to contact me at (772)464-3537 or via the Email address referenced above. ,�}1t 11117tt/1�� Sir4hielygLA IF L �� `6'Q`�i.`�'•' 1GENSF •. �' i j f PEI�PER & Tt6E�IING, INC. .38 3 J_ -13 F� { ffiri, �Px.+ Sett 12Z de��,�� FlorTd./ 38723 r rnittt Cc: Gregg R. Wexler RECEIVED SEP 13 2019 ENGINEERING DIVISION A LEGACY OF EXPFRTISE AND EXCELLENCE 2980 SOUTH 25TH STREET I FT. PIERCE, FL 34981 . (772) 464-3537 . FAX:(772) 464-9497