Loading...
HomeMy WebLinkAboutSIGN PLANSINDIVIDUAL INTERNALLY LED ILLUMINATED CHANNEL LETTERS ON RAC HLE COPY SCANNED BY St. Lucie County 20' STOREFRONT REVIEWED FOR S.F. CODE COMPLIANCE STn LUCIE COUNTY BOCC ALLOWABLE 51GN AREA 5TOREFRONT = 15' X 20' = 300 5.F. 500 X 20% = 60 S.F. 51 G N = 21" X 198" = 28.9 5. F, MIN.SETBACK FRONT CNR RECEIVED APR 2 3 2019 ST. Lucie County, Permitting JOB TITLEAMERICANWEINE55 ADDRESS P5L OAPPROVED 4444 S.E. COMMERCE AVE. FL. S4997 TnLa..m4 una.nna a.p.n. .w iM s�u.tw Vrn br Dt fltunlnao NOTE: ALL ARTWORK 6 COLORS MUST BE SIGNED OFF BEFORE ANY WORK 15 TO BEGIN O APPROVED W/CHANGES STUART, 772.220.7768 61ym. Ma mq nm4.�mm to un qn.n '°:na n.v: Mur ui joE noieeuaE IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER 15 V O NOT APPROVED Ramingaslgns@aol.com In, u.C%u aomta.Qo%wa.n,Z.ncnn..m RESPONSIBLE FOR ANY CHANGES ONCE WORK BEGINS. RESUBMIT CHANGES N `'1NDIVIDUAL 1NTERNALLYIED ILLUMINATED'.CHAN,NEL LETTERS ON RACEWAY Letters to be fabricated of .063 aluminum backs with.040 black returns. Interior of letters to be �®R white. gloss white. W W REVIEED pQ� ply Faces to be 3/16" 7328 white acrylic with 1" ��®C CD�r9�1/'��`+D� G II black Gemini 2026 lrimcaps, 5 in 4 ��I L Lighting to bright white Hanley led modules STo LUCIE COUNTY attached with 3M VHB tape, Power be with Hanley 120 / 12 v. 1.1a premium power supplies. O..DD��DD power sus li SOCC Letters mounted to EMS aluminum extruded , raceway minimum 4 per letter #8 tech screws. Raceway fabricated of .125 aluminum to meet _ UL standards. Backs have Inset track to accept 2" mounting clips. Clips to be spaced no more than 48" max. 1 top & 1 bottom with minimum 2 pair per raceway. " Raceway painted to match wall section. UL Rated disconnect mounted to and of raceway Primary electrical feed in UL conduit connected to existing power supply to be provided. Wall section: Concrete Block Sign mounted to wall section with 318" hardware to be determined by wall type with minumum 2" embedment. 4 SETS OF 2 - 3/8" X 3.25" EXPANSION ANCHORS (1) 20 amp 120V Circuit Req. This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. UL TED 1) Grounded and bonded per NEC 600.7/NEC 250 2) Existing branch circuit In compliance with - NEC 600.5,not toexceed 20amps SIGN TO BE INSTALLED ACCORDING 3) Sign is to be UL listed per NEC 600.3 U� TO 2014 NEC (N. F.P.A. 70) 600.3 4) UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer' 'For multiple signs, a disconnect is permitted but not required for each section ULTIMATE WIND VELOCITY = 170 MPH R15K CATEGORY II EXPOSURE "C" I'� 6th EDITION "2017 FBC" JOB TITLEAMERICANN WELLNE55 ADPFE55 P5L 5LC - ff 4&'!® 44445.E.COMMERCE AVE ' STUART, FL. 34997 JAME5E. PAIT, P.E. PEG #25497 NOTE: ALL ARTWORK & COLORS MUST BE SIGNED OFF BEFORE ANY WORK 15 TO BEGIN 122015.E. COLEY AVE. HOSE SOUND, FL 33455 IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEA5E NOTE, CUSTOMER 5 77222 D 7377 FAX 772 22 0 7768 PHONE 265-2677 RESPONSIBLE FOR ANY CHANGES ONCE WORK BEGIN5,