Loading...
HomeMy WebLinkAboutDOOR REPLACEMENT PLANSCANNED BY "t. Lucie County 36" X 80" REPLACE DOOR IN 1 OPENING ONLY. NEW DOOR TO BE IMPACT RESISTANT - HURRICANE SHUTTERS NOT REQUIRED. RECEIVED ppR 29 mg permitting Depert..ent St. Luce County /fay-o&qL REVIEWED F'OF CODE COMPL1AN ST, LUCIE COUNT BO C LE COP OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A. #) POS. NEG. 1 36 1 80 20.01 4 52.5 1 -60.9 FL16708.1 65.0 1 -65.0 FRONT ENTRY - LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT = 126 FT 6 IN LUNSFOR CONDO UNIT 9600 S. OCEAN DRIVE, UNIT502 HUTCHINSON ISLAND, FLORIDA DOOR REPLACEMENT PLAN