HomeMy WebLinkAboutDOOR REPLACEMENT PLANSCANNED
BY
St. Lucie County
36" X 80"
REPLACE DOOR IN 1 OPENING ONLY
NEW DOOR TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
RECEIVED
APR 3 0 2019
ST. Lucie County, Permitting
l qn y -r>Yyb
a �EYIEWED FOR
COMPLIANCE
LUCIE COUNTY
gpw—
�
FILE
OPENING
PRODUCT
� DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO. WIDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 36 80
20.00
4
56.3 1 -57.1
1 FL16708.1
1 66.0 1 -65.0
1 FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 87 FT 4 IN
FAZIO CONDO UNIT
9490 S. OCEAN DRIVE, UNIT 911A
JENSEN BEACH, FLORIDA
DOOR REPLACEMENT PLAN