Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONULTIMATE TENSION AND SHEAR VALUES (LBS/KN) IN CONCRETE ANCHOR DIA In.(mm) MIN. DEPTH OF EMBEDMENT mm In.() . - TENSION Lbs. (kN) SHEAR Lbs. (kN) ... TENSION Lbs. (kN) SHEAR Lbs. (kN) TENSION Lbs. (kN) SHEAR Lbs. (kN) TENSION Lbs. (i SHEAR Lbs. (kN) 3/16 (4.8) 1(25.4) 600 (2.7) 720 (3.2) 625 (2.8) 720 (3.2) 650 (2.9) 720 (3.2) 800 (3.6) 860 (3.8) 1-1/4 (31.8) 845 (3.7) 720 (3.2) 858 (3.8) 720 (3.2) 870 (3.9) 720 (3.2) 1,010 (4.5) 860 (3.8) 1-1/2 (38.1) 1,090 (4.8) 860 (3.8) 1,090 (4.8) 860 (3.8) 1,090 (4.8) 860 (3.8) 1,220 (4.8) 860 (3.8) 1-3/4 (44.5) 1,450 (6.5) 870 (3.9) 1455 (6.5) 870 (3.9) 1,460 (6.5) 990 (4.4) 1,730 (7.7) 990 (4.4) 1/4 (6.4) 1(25.4) 750 (3.3) 900 (4.0) 775 (3.4) 900 (4.0) 800 (3.6) 1,360 (6.1) 950 (4.2) 1,440 (6.4) 1-1/4 (31.8) 1,050 (4.7) 900 (4.0) 1,160 (5.2) 900 (4.0) 1,270 (5.6) 1,360 (6.1) 1.515 (6.7) 1,440 (6A) 1-1/2 (38.1) 1,380 (6.1) 1,200 (5.3) 1,600 (72) 1,200 (5.3) 1,820 (8.1) 1,380 (6.1) 2,170 (9.7) 1,670 (74) 1-3/4 (44.5) 2,020 (9.0) 1,670 (7.4) 2,200 (9.8) 1,670 (7.4) 2,380 (10.6) 1,670 (74) 2.770 (12.3) 1.670 (7.4) Safe working loads for single installation under static loading should not exceed 25%of the ultimate load capacity. ULTIMATE TENSION AND SHEAR VALUES (LBS/KN) IN HOLLOW BLOCK LIGHTWEIGHT BLOCK MEDIUM WEIGHT BLOCK ANCHOR ANCHOR DIA Isn(mm) EMBEDMENT In.(mm) TENSION SHEAR TENSION SHEAR Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 3/16 (4.8) 1(25.4) 220 (1.0) 400 (1.8) 340 (1.5) 730 (3.2) 1/4 (6.4) 1(25.4) 250 (1.1) 620 (1.8) 500 (2.2) 1,000 (4.4) Safe working loads for single Installation under static loading should not exceed 25%of the ultimate load capacity. NOTE: 3/16" Tapcon requires 5/32" bit. 1/4" Tapcon requires 3AV bit. ALLOWABLE EDGE AND SPACING DISTANCES NORMAL WEIGHT CONCRETE CONCRETE MASONRY UNITS [CMU) PARAMETER ANCHOR DIA. In.(mm) FULL CAPACITY REDUCED LOAD FULL CAPACITY REDUCED LOAD (Critical Distance CAPACITY REDUCTION (Critical Distance CAPACITY REDUCTION Inches) (Minimal FACTOR Inches) (Minimal FACTOR Distnce Inches) Distance Inches) Spacing Between 3/16 3 1-1/2 0.73 3 1-1/2 1.00 Anchors -Tension 1/4 4 2 0.66 4 2 0.84 Spacing Between 3/16 3 1-1/2 0.83 3 1-1/2 1.00 Anchors -Shear 1/4 4 2 0.82 4 2 0,81 Edge Distance- 3/16 1-7/8 1 0.83 3 2 0.91 Tension 1/4 2-1/2 1-1/4 0.82 4 2 0.81 Edge Distance- 3/I6 2-1/4 1-1/8 0.70 3 2 0.93 Shear 1/4 3 1-1/2 0.59 4 2 0.80 For SI:1 inch = 25.4 min 7. The uniform load distribution on each member shall be calculated in accordance to Section 2, Engineering Design Rules, of the AAMA 103.3 Procedural Guide. 8. Compared unit shall not exceed the maximum cyclic pressure when tested per TAS 201, TAS 202 and TAS 203 or ASTM E 1886 and ASTM E 1996. R.7k114'4E31E te> io�r daor assem6G7. Exterior door assemblies not covered by Section 1714.5.2 or Section 1714.5.3.1 shall be tested for structural integrity in accordance with ASTM E 330 Procedure A, at a load of 1.5 times the required design pressure load. The load shall be sustained for 10 seconds with no permanent deformation of any main frame or panel member in excess of 0.4 percent of its span after the load is removed. High -velocity hurricane zones shall comply with TAS 202. After each specified loading, there shall be no glass breakage, permanent damage to fasteners, hardware parts, or any other damage which causes the door to be inoperable. The minimum test sizes and minimum design pressures shall be as indicated in Table 1714.5.3. The unit size tested shall qualify all units smaller in width and/or height of the same operation type and be limited to cases where frame, panels and structural members maintain the same profile as tested. TABLE 1714.5.3 MINIMUM TEST SIZES, INCLUDING FRAMING MINIMUM PERFORMANCE PERFORMANCE WIDTH WIDTHX GRADE (DESIGN CLASS' HEIGHT (mm) HEIGHT (IN.) PRESSURE) Residential (R) 900 x 2000 (36 x 79) 720 Pa (15 psi) Light 1200 Pa Commercial 900 x 2100 (36 x 83) (25 psf) (LC) Commercial 1000 x 2100 (40 x 83) 1440 Pa (C) (25 psfl Heavy 1920 Pa Commercial 1200 x 2400 (48 x 95) (40 psfl (HQ Architectural 1200 x 2400 (48 x 95) 1920 Pa (AW) (40 psfl 1. Performance Class and Performance Grade per ANSI/AAMA/NWWDA 101/I.S.2. 1714.5.3.1 Sectional garage doors and rolling doors shall be tested for determination of structural performance under uniform static air pressure difference in accordance with ANSI/DASMA 108, ASTM E 330 Procedure A, or TAS 202. For products tested in accordance with ASTM E 330, testing shall include a load of 1.5 times the required design pressure load sustained for 10 seconds, and acceptance criteria shall be in accordance with ANSI/DASMA 108 (HVHZ shall comply with TAS 202).