HomeMy WebLinkAboutDRAWINGSCANNED
BY
St. Lucie Counf,
Rosenbach Residence
3000 N Hwy A 1 A# PHV-11 C
Fort Pierce
Stack as much as
possible here.
-----------------------------------------------\
No shutters to remove here.
BEIGE HV Accordion Shutters.
71"
4
UNDERSIDE OF CONCRETE SLAB
SEALANT, TYPICAL
BOTH SIDES
CONT. TOP TRACK SET IN TWO
CONT, PARALLEL SEALANT
BEDS
5/8" FIRE RATED GWB
R-19 FIBREGLAS BATT
INSULATION
5/8" EXT. FIRE RATED
GYPSUM SHEATHING PER ASTM
C79 REQUIREMENTS
6" GALV. STEEL STRUCTURAL
STUDS 0 16" O.C. MIN.
EXTERIOR STUCCO FINISH
SYSTEM OVER 2" THICK
POLYSTYRENE INSULATION
CONT. GALV. STEEL BASE
TRACK SET IN TWO CONT. -
PARALLEL SEALANT BEDS
SEALANT, TYPICAL
CONCRETE FLOOR SLAB
-- ----- - -' CONTROL JT. W/SEALANT &
BACKER ROD
1-1/2" RECESS ® 1ST FLOOR
ONLY
aFEIRE RATING: 1 HR DESIGN: UL 465or
GA-WP-1200
. RATING: N/A TESTING NO. ; N/ARATING: N/A TESTING N0, ; N/A
UNDERSIDE OF CONCRETE SLAB
SEALANT, TYPICAL
v
[A]