Loading...
HomeMy WebLinkAboutCERTIFICATION REPORTV�r—% Metal Roof Certification & Listing Program KElI'STOIy. C:. INCertification Report Im CERTIFICATIONS, _L J=­1 0"12 11027-003-KCI 145 Limekiln Road, Suite 1008 Issue Dated: 9/29/2017 New Cumberland, PA 17070 Revision Date: 01/23/2018 www.kevstonecerts.com Expiration Date: 9/29/2022 SCANNED BY St. Lucie County Construction Specifications Institute (CSI) Category: Division: 070000—Thermal & Moisture Protection Section: 07 41 13 — Metal Roof Panels 1. Program Licensee: MFMRS Mid Florida Metal Roofing Supply, Inc. 28328 County Road 561 Tavares, FL 32778 352-742-7070 http://www.midfloridametaIroofingsupply.com 2. Certified Roof Covering: MFMRS Multi -Rib structural through -fastened metal roof panels installed over 2x4 purlins for use in new construction. 3. Scope of Certification: This Certification Report provides technical data substantiating that the use of the certified roof covering and the evaluated roof systems are in compliance with the following: • 2017 Florida Building Code - Building, 6th Edition, Section 1504.3.2. • Florida Product Approval Rule 61G20-3. Properties Evaluated: • Wind Uplift Resistance This Certification Report was used in the qualification of Florida Product Approval FL23490. 4. Evaluated Roof System Description: 4.1. Roof Covering: MFMRS Multi -Rib metal roof covering panels are cold roll -formed from 29 gauge (0.016" / 0.406mm coated thickness) steel sheet having a minimum yield strength of 90ksi. The panels are aluminum -zinc alloy coated per ASTM A792 (AZ50), and shall be installed in accordance with the manufacturer's instructions and this Certification Report. 4.2. Roof Deck: MFMRS Multi -Rib metal roof panels are certified for use over No. 2 nominal 2x4 lumber purlins, maximum 24" O.C., complying with 2017 Florida Building Code, Section 2303.1.1 and as specified in this report, with a minimum roof slope of 25% (3:12). 4.3. Anchorage: MFMRS Multi -Rib metal roof panels shall be through -fastened to the specified purlins using #12-8 x 1" HWH Woodgrip XG screws with''/:" self-sealing washers applied in the patterns described in Appendix 1. S. Installation MFMRS Multi -Rib metal roof panels in new construction applications shall be installed in accordance with the 2017 Florida Building Code Section 1507.4, the manufacturer's published installation instructions and this Certification Report. The manufacturer's installation instructions shall be made available at the time of installation. If there are differences between this report and the manufacturer's installation instructions, this report shall take precedence. Refer to www.kevstonecerts.com to ascertain the ongoing status of this Compliance Certificate. Approval of building products and/or materials can only be granted by the building official having Jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. 1, i' <i. Metal Roof Certification & Listing Program Certification Report `'] CL'riTIFICAT10N5. INC. 11027-003-KCI ``� Page 2 of 4 i f 4 : 1 6. Product Performance The performance of the MFMRS Multi -Rib structural 'through -fastened metal roof panels described in this Certification Report has been demonstrated via testing in accordance with the following referenced standards: ASTM E1592-01, Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference" As tested & reported by the following independent accredited laboratory: Laboratory Report Ref. PRI Construction Materials ' Technologies FAE-008-02-01 Note: The ASTM E1592-01 standard is equivalent to the ASTM E1592-05(2012)standard. 7. Wind Resistance The allowable design uplift pressures for MFMRS Multi - Rib anchored as described in Appendix 1, when tested in accordance with the referenced standards with an applied safety factor of 2.0 are found in Table 1. Table 1 Description Max Design Uplift Pressure 29 Ga, 90ksi Steel Over No. 2 Nominal 2x4 Purlins 105.0 psf Maximum 24" O.C. r 1 8. Conditions of Use MFMRS Multi -Rib structural through -fastened metal toof`,`) "I panels must be insulated against other materials or metals including concrete, lead, copper and treated , lumber that contains corrosive materials. i 9. Limitations of Use MFMRS Multi -Rib non-structural through -fastened. r metal roof panels are not qualified for use in the High - Velocity Hurricane Zone (HVHZ). Fire classification, shear diaphragm design and purlin ; attachment to supporting members are not within the scope of this Certification Report. Roof support framing shall comply with 2017 Florida' I� Building Code Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. 10. Licensed Manufacturing Facilities This Certification Report is applicable only to MFMRS,. ,? ••-I Multi -Rib structural through -fastened metal roof panels, manufactured at the following locations. Each licensed.? facility is subject to periodic inspection by Keystone Certifications to verify conformance with Keystone Roof. Covering Certification & Listing Program requirements: Mid Florida Metal Roofing Supply, Inc. 28328 County Road 561 uI Tavares, Florida 32778 • G'� ; ' :Refer to www.kevstonecerts com to ascertain the ongoing status of this Evaluation Report. Approval of building ,II Rproductsand/ormaterials can only be granted by he building official havingjurisdfctional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or • suitability of a product for a given use. Metal Roof Certification & Listing Program EIYSTO NF Certification (deport .':, CErtTIFIOA'I•IONS. INC. 11027-003-KCI Page 3 of 4 '11.Identification MFMRS Multi -Rib structural through -fastened metal roof panels represented by this report shall be identified with Keystone Roof Covering Certification & Listing Program certification labeling illustrated below, to be applied to individual panels, packaging, invoicing or bills of lading: keystonecerts.com .7 I 11027-003-KCI Aaron Shultz .1 2018.01.23 13:53:38 it -05,00, ' Aaron Shultz Validations Manager i .a i' Refer to www.kevstonecerts.com to ascertain the ongoing status of this Evaluation Report. Approval of building products and/or materials can only be granted by the '! building official having Jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance oK ` �d i suitability of a product for a given use. I ; .' `7 Metal Roof Certification & Listing Program KjEYSTON Certification Report j. 11027-003-KCI Page 4 of 4 Appendix 1 Multi -Rib Panel'Open Frame Fastener Location Anchored to 2x4 Purlins Maximum 24" O.C. i. Y4-14 X Ya- HWH SD WITH SELF-SEALING WASHER #12-8X I"HWHWOODG91PXG WITH SELF-SEALING WASHER 6--3--6--3-PATTERN ' Refer to www,keystonecerts.corn to ascertain the ongoing status of this Evaluation Report. Approval of building products and/or materials can only be granted by the building official havinglurisclictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance ori suitability of a product for a given use. f IA: