Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED JUN 0 6 Zp,9 BY NEORECtd. Si. Lucie Count+ L , Lucie County, Permitting eerojicare of Authror&ovon®32455 53 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Owens Coming Roofing and Asphak LLC Evaluation Report 111980:11.08+R6 One Owens Corning Parkway FL11602-11116 Toledo, OH 43659 Date of Issuance:111/03/2008 (740) 321-6345 Revision 6: 06/20/2018 SCOPE: This Evaluation Report is Issued under Rule 63G203 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Wit Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium"' Roof Underlayments LASEuNo: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc, requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADvornsEMENr: The Evaluation Report number preceded by the words "NEM01etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report Is displayed, then R shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to -the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared b • uo." Robert J.M.Nieminen P.E.s'e� ° +oy^^.�," Tne facsim8e seaiappeadngvras authorized by 8a6ert HorfdaRegistrationNo. 59266,Florida DCAANE1983 a:Nn^•O• Nieminen.P.Fon86128/2818.Mdoesnotserveasan electronically signed document CERMIGTION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it Intend to acquire or will it acquire, a financial Interest In any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products R evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. S. This Is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project an which this Evaluation Report, or previous versions thereof, Wwas used for permitting or design guidance unless retained specifically for that purpose. ONEMOjetc. COMPONENT EVALUATION: Sub -Category: Underlaytlent Compliance Statement: Titanium^' Roof Underlayments, as produced by Owens coming Roofing and Asphalt, LLC,have demonstrated compliance with the Intent of the following sections of the 0 Edition (2017) Florida Building Code through testing In accordance with applicable sections the following Standards. Compliance is subject to the installation Requirements and limitations / Comfitions of Use set forth herein. 1507.1.1,R905.1.1Exception Unrolling,8reakingStre 1507.1.2, R905.1.1 Exception Tear Strength.. 15071.1, T15071.1,15072.92 Physical. Properties 1507.33 Physical Properties TAS 110 Accelerated:.W6atheriry TAS 110 Pul4hrough resistance, ERD(TST6049) Physical. Properties 6RD (TST6049) Physical Properties ERD M6049) Physical Properties ERD (TST6049) ASTM D226 ERD (TST6049) Wind Uplift IT5(TM509) ASTM D226 ITS (TST1509) ASTNi 0226 ITS(TST1509) Physical Properties ITS(TST1509) ASTM D226 Owens Coming Product equivalency PRI (TSS878) ASTM 01970 , PRI (TST5878) ASTM D3970; Tear strength PRI(TST5878) ASTM D1970; Tear strength PRI OWS878) ASTM 01970; Tear strength PRI(ISf5878) ASTM. D4799 PRI(TST5878) TAS 117(4);. Pull -through ITS (QUA1673) Qualify Control IS(QUA1673) Quality Control ASTIN 61970 2015 ASFMD1970 2015 FRSA/M April 2012 (04-12) 2012 ASTM 04798 2011 TAS UAB) 1995 115010.05.10 05/14/2010 135520.06.11 06/25/2011 138010A811 08/11/2011 135520.0811-1 08/12/2011 3118D3000Q-003 04/26/2007 3130639CC -002A 09/21/2007 3126617COQ-005 10/3112007 101823107CCIO 011 01/23/2015 Declaration 06/18/2018 C CF-341-02-01 09/20/2017 OCF-331-02-02 10/03/2017 OCF-332.02-02 10/03/2017 OCF,334-02-02 10/03/2017 OCF-34102-01 11/27/2017 OCF-422-02-02 04104/2018 ITS Ustings _ Current Service Confirmation 09/30/2017 4.1.1 Titanium"' PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer - coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 lbs/square. Meets ASTM D1970 as a singIL4ayer and meets FRSA/TRI April 2012 when used in 2-ply system. MEMO ETC, LLC Evaluation Report 111980.11.MR6 Certij¢ate ofAuftr¢odana32455 6- EDITION (2017) F13C NON44VHZ EVALUATION FL11602-R6 Thanlum Roof Undemaymetns Revision 6: 06/20/2018 Page 2 of 7 ONEmoletc. 4.2 MechanicaRv Fastened Underlayments:. 4.2.1 Titanlumu UDL-25 Is a synthetic sheet type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 lbs./square; meets FBC 1507.1-1 & R905.1.1(Exception). 4.2.2 Titanlumi a UD630 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.01bs./square; meets FBC 1507.1A & R905.1.1(Exception). 4.2.3 Titanium'" UDL-501s a synthetic sheet -type polymer coating. Unit weight 4.7 (bs./squari sed of a woven core coated on both sides with a & R905.L1(Exception). of Record for any project an which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that.purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fre.Class(fication is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product 5.4 Tltan)ufn" Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FSC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: OPTIONS ''=-'A9PHAlT :w^x < � ,N ;>�'"� ��` :' WOODSIiItKES ''� '-�,•'',: UNDER[AYMENi SHINGLES ,HAD.-0NT1LE FOAM-0N T0.E ... _ ... ._METAL &SNiPIGtES SIATE� Titanium PSU-30 yes Yes Yes Yes Yes Yes (Dubai, UAE) (See 5.5.1) Titanium PSU-3D Yes No Na Yes Yes Yes (Brentwood, NH) Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes is„eamin2-Fir iBu,esiroeiin2-yr Yes Yes Yes gVeml nuemi Titanium UDL-50 I Yes No. No Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use tile adhesives / underlayment combinations. Dow TileBond"' I FL22525 Titanium PSU-30 (Dubo, UAE) ICP Adhesives Polysete AH-160 I FL6332 Titanium PSU-30(Dubai, UAE) 'Refer to Tile Manufacturers or Adhesive Manufacturers Florida Product Approval far Overturning Moment Resistance Performance. NEMa ETC, U.0 Evaluation Report I11960.IL06-R6 Certfi teo(Auleoriniftn F32455 eEDITION (Z017)FBC NON-HVHZ EVALUAtiON ft11602-R6 Titanium Firm} Underlayments Revision 6: 06/20/2018 Page 3 of 7 "NEMOletc. 5.6 Allowable Substrates: Titanium PSU-30: " 5.6.1 Direct -Bond to Deck: > New untreated plywood; > Existing untreated plywood, primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base Sheet: > ASTM D226, Type I or II felt. > Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted). 5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -an tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations.apply to underlayment systems that are not addressed in FRSA/TRI April 2022 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-4S osf: Deck: Min. IS/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM .D41 Underlayment: One or two plies, Titanium PSU-30 (Dubai, LIRE), self -adhered #2 Maximum Design Pressure= -30 PW Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-Inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered #3 Maximum Design Pressure=-30 DW: Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga: annular"ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8' diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered NEMO ETC, LLC Evaluation Report 121980.11.08-0 OeMpmre opaumoraanon 032455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FU16021116 Titanium Roof Underlairme is Revision 5t 06/20/2018 Page 4 of 7 "NEM0 I etc. #4 Maximum Desian Pressure =-45 psi": Deck: Min, 15/32 inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30(inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per Inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32ga, 1-5/80 diameter tin caps Spacing: 64nch o.c.. at 4-inch wide side laps and 8-inch o.c; at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin•caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered #5 Maximum Design Pressure =-45 csf': Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per Inch, heads not less than 3/8 inch diameter and length sufticlent to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps. Spacing: 6-Inch o.c. at Minch wide side laps and 8-Inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Undertayment: One or two plies, Titanium PSU 30 (Dubai, UAEJ, self -adhered 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case; Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention DataSheet.l-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations. Titanium UDL-25, Titanium UDL-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 190-days. 5.9 Tile Slippage Limitations (per FRSA/TRI April 2012 (OM22)1: When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as follows: -These slope limitations -an only be exceeded6Yusing battens during loading ofthe-roofiiles.- — -- Titanium PSU-30 (Dubai, UAE) Max.1D-tile stack Max.10-tile stack 6:12 MEMO ETC, LLe Evaluation Report 111980.11.08-R6 Ce,ofto0r ofAmmmmVon A32A55 6- EDMON(2017) FBC NON-WHZ EVALUATION FL116OZ-R6 Titanium Roof Underlayments Revision 6.06/20/2029 Page 5 of 7 published Installation requirements subject to the Umitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6,3 TiFaniun UDLiS,,fitaniumU6L36orTftanium,UDl-SOt_ m _ . 6.3.1 Shall be installed In compliance with the requirements for ASTM D226, Type I or it underlayment In FBC Table 1507.L1 or R905.11 for the type of prepared roof covering to be installed, considering the wider sheet -width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-t5 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of Titanium UDL-SO is limited to ring shank roofing nails with minimum 3/8-4nch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3.2.1 Code Reference: The Exception statement In FEC 1507.1.1 and FBC R905.1.1 states: ':_except metal cap nails shall be required where the ultimate design wind speed, V,,,ry equals or exceeds 150 mph." Owens Coming Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the Titanium"' UDL.25, Titanium UDL-30 or Titanium UDL- 50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.3 Slooes of 4:12 or greater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Minimum, attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the exposed face of the underlayment. When batten systems are to he installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: Double layer application; begin by fastening a 254nch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25- inch side (horizontal) laps, resulting in a double -layer application. 6A Titanium"' PSU30r _ 6.4.1 Shall -be installed in compliance with the codified requirements for ASTM D1970 underlayment-in FBC Table 1507.2.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Cover: Cut manageable sections and re -roll with the release film side out. Membrane Application: ➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place, printed side up. > Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. D Apply subsequent courses parallel to the eave in a shingle -type, water -shedding manner. ➢ End (vertical) laps shall be minimum 124nches and side (horizontal) laps shall be minimum 34nches. ➢ If the membrane becomes misaligned, cut the roll and re -start. 7 Upon completion, inspect the membrane and repair any defects or fish -mouths. NEMO ETC, LLC Evaluation Report 111980.11.0R-R6 Cvtiflmte,fAvdWdmti,ns32455 eEDmON(2017)F11C NON-NVIR EVALUATION FL11602-R6 Titanium Roof Underlayments Revision 6:06/20/2018 Page 6 of 7 ONEMOjetc. 6.4.3 Tile Applications rl'rtanium PSU-30 /Daboi, UAE p I Reference is made to FRSAf1 RI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and OwensComing Roofing and Asphalt, LLC published requirements for tile staging. 65 Titapiutni-Ply System' .... 6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UD43o (top -surface primed or inverted) mechanically attached to the wood roof deck followed by Titanium PSU30 (Dubai, uAE), self -adhered. 6.5.2 Non -Tile Application: Install Titanium UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3 followed by Titanium PSU-30 (Dubai; UAE) in accordance with Section 6.4. 6.5.3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) installation Manual and Table i herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing, refer to Owens Corning Roofing and Asphalt, LLC published installation instructions, but not less than the fastener density from FRSA/TRI April 2012 (04-12), Table 1, considering the wider sheet -width. For adhesive -set tile roofing, refer to Section 5.6.3 herein. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underiayment Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading of roofing tiles. The use of sealant or mastic at file fastener.penetrations is required for all the roofing installations. Contact mans rnrninti Roofine and Asphalt, LLC for approved sealant or mastic types. of this product. The following plants have qualified products under their respective pnystcai Prpperues hp--u - - END OF EVALUATION REPORT - Evaluation Report 11198611.68-R6 MEMO ETC, LLC FL11602•R6 CertiBtute ofAefnonlAttan 932455 6- EDITION I1D171 FBC NON-WMZ EVALUATION Revision 6:06/la/Z018 Titanium Raaf undedaymenes Page 7 of 7 RECEIVED CREEKMAV ®7 1019 Certificate of Auth7520 Edinburgh 29824 mitring Department Tampa, FL 33647 `TECHNICAL, SERVICES, �,Lrt. Lucle county (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 61e EDITION (2017) Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued Octobers, 2017 P.O. Box1404 Joplin, MO 64802 (417) 624-6644 hlta t/www.tamko corn S'CA Manufacture Location: Silvassa, India St uClt? y ,, L Quality Assurance: Intertek Testing Services NA Inc. (QUA1673) COun)y Category: Roofing Subcategory: Underlaymenis Code Sections: 1507.1.1, 1518.4 Properties: Physical properties PRODUCT DESCRIPTION TAMKO SyntheticGuard A mechanically attached, synthetic underayment composed of a black coated Polypropylene spun bond fabric surface, a polypropylene 5x5 scrim on the exposed side and a black coating on the sheathing side (nominal weight = 2.11 Ib/100P). The undedayment shall be used an altemative to ASTM D 226, Type II roofing underiayments and has demonstrated a minimum tear strength of 20 pounds when tested in accordance with ASTM D 1970. The product is supplied in 9.2-sq rolls with nominal dimensions of 4-ft x 250.5-ft. Unless otherwise noted, the following application details shall be followed for New and Existing construction. See manufacturer's installation instructions for further detail. TAMKO SyntheticGuard A mechanically attached, synthetic undedayment composed of a grey coated Plus polypropylene spun bond fabric surface, a Polypropylene 10x5 scrim on the exposed Side and a grey coating on the sheathing side (nominal weight = 3.05 Ib/100P). The underlayment shall be used an alternative to ASTM D 226, Type II roofing undedayments and has demonstrated a minimum tear strength of 20 pounds when tested in accordance with ASTM D 1970. The product is supplied in 9.2-sq rolls with nominal dimensions of 4-ft x 250.5-ft. Unless otherwise noted, the following application details shall be followed for New and Existing construction. See manufacturer's installation instructions for further detail. Ihis evaluation report is provided for State of Florida product tty CREEK duration far which this report valid. I under Rule 61GZ0-3. The manufacturer shall notify C age 1 of 3 Technical Services, LLC of any product changes or quality assurance changes throughout the This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS, INC. TECHNICAL SERVICES, LLC SynthaticGuard APPLICATION fitted construction. Deck shall be installed in accoIrdance wiittho FBC requirements. s Roof Deck: The roof deck shall be constructed of close) ng shall have no more than 1/8° gap at abutting joints. Roof deks Application: Non-HVHZ: Underayment shall be installed in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions. HVHZ: Underlayment shall be installed with a minimum 4-inch head lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings: Non-HVHZ: Underlayment shall be used with mechanically attached roof covering systems as prescribed in FBC Section 1507.1.1. HVHZ: Underlayment shall be used with mechanically attached asphalt shingles, wood shakes and shingles, non-structural metal roofing, or quarry slate. 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) The underlayment may be used as described in other current FBC product approval documents. 7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 8) The underlayment shall not be installed over existing roof coverings. 9) All undedayments shall be installed with the roll length parallel to the save, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Enti Report No. Standard Intertek Testing Services NA Ltd. (TST1509) 102404168COQ-004 ASTM D 226 Year Intertek Testing Services NA Ltd. (TST1509) 102404168COQ-012 2012 Intertek Testing Services NA Ltd. (TST1509) 10275111000Q-002 ASTM A 08 2011 PRI Construction Materials Technologies ST5878 ASTM E 226 2009 9 R ) TAP-393.02-01 ASTM D 226 2009 ASTM D 4869 2016 PRI Construction Materials Technologies (TST5878) TAP-394.02-01 ASTM D 4533 2015 ASTM D 226 200909 ASTM D 4869 2016 ASTM D 4533 2015 •- .••--���� ��� ���e yr riunoa proauct approval under Rule 61G20-3. The manufacturer shall n� Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes specifically addressed herein. 2 of is valid. are not ®CREEK TECHNICAL SERVICES, LLC TAMKO BUILDING PRODUCTS, INC. SyntheticGuard COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6'n Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. `%%,G�PRO E N Sp9�Cc�'�i ,• �;: � F • sue'% No 74021 ��: STATE OF :414 �,. •:OR�pP��C;,� CERTIFICATION OF INDEPENDENCE 2017.10.05 12:51:28 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor all it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, norwill acquire, a financial Interest In any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest In any other entity Involved in the approval process of the product END OF REPORT --' - I ---ioFL19948-RI This evPage 3 of 3 aluatn report is provided for State of Florida product approval under Rule 81G20-3. The manufa Technical Services, LLC of any product changes or quality assurance notify CREEK chcturer shall This evaluation report does not express nor imply warranty, Installationanges throughout the duration for which this report is valid. specifically addressed hereto. , recommended use, or other product attributes that are not 5-Ol y 2 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, r EDITION (2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September25, 2017 220 West 40 Street Joplin, MO 64801 61 VL (417)624-6544 SCANNED /�J6— QMO Manufacturing Plants: Joplin, MO BY RECEIVED REVIEWED FOR Phillipsburg, Ks St. Lucie County Frederick, MD tom 0 7 ' ;ODE COMPLIANCE Dallas, TX Tuscaloosa, AL p,,mltSt.tm 00ST.`LUCIE COUNTY Quality Assurance: UL LLC (QUA9625) BOCC SCOPE Category: Roofing W I IJLL, E Copy Subcategory: Asphalt Shingles (I..lfill Code Sections: 1504.1.1, 1507.2.5. 1507.2.7.1. 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain Enti Reoort No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-064-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130.02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP303.02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP307-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies (TST5878) TAP317-02-01 TAS 100 1995 UL LLC (TST9628) UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (rST9628) 04NK24368 ASTM D 3462 2010A 05NK28008 ASTM D 6381 2008(2013)e1 UL 2390 UL LLC (TST9628) (T ) 06NK03898 ASTM D 7158 ASTM D 3161 2011 2016 UL LLC (TST9628) R ) 08CA59132 ASTM D 3462 ASTM D 3161 2010A 2016 ULLLC (TST9628) 09NK07896 ASTM D 3161 2016 UL LLC (TST9628) (T 1OCA50498 ASTM D 3462 ASTM D 3462 2010A 2010A UL LLC(TST9628) UL LLC (TST9628) 10CA64882 ASTM D 3161 2016 11NK14014 ASTM D 3161 2016 ULLLC (TST9628) R ) 12CA24551 ASTM D 3462 ASTM D 3161 2010A 2016 UL LLC (TST9628) LLC (TST9628) 4786110543 ASTM D 6381 2008(2013)et UL UL LLC (TST9628) 4787043752 ASTM D 3161 2016 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 CREEK Technical Services LLC ( ANE11669 ) TBP15001.3 ASTM D 3462 2010A Calculations 2017 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. W CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite GlassSeal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4' x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-114" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin, Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 13-1/4' x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Vintage® 17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage® Hip and Ridge 12" x 12', ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC INSTALLATION Elite GlassSeal® Basic Wind Speed (V g,): (Frederick, Joplin & Basic Wind Speed (Va,e) Tuscaloosa) Deck (HVHZ): Glass -Seal (Frederick, Joplin (Non- HVHZ) & Tuscaloosa) Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ) TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in, plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or 06 Nail Pattern" detailed below. -718n 5-1I81, Figure 1. Elite Glass -Seal & Glass -Seal 4 Nail Pattern (Non-HVHZ only) -7/8a i"118" Figure 2. Elite Glass -Seat & Glass -Seal 6 Nail Pattem TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed (V°10: (Dallas, Frederick, Joplin, Basic Wind Speed (V,,d): Phillipsburg & Tuscaloosa) Deck (HVHZ): Heritage® Premium (Dallas, Frederick Phillipsburg & Tuscaloosa) Deck (Non-HVHZ): Heritage® Woodgate (Dallas & Frederick) Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Patterns or "6 Neil Pattern" detailed below. NAIL ZON E BOND EXPOSURE &6/8" I" �111— 12-1 /2" -+-12-318r' —►- 12-1 /2"--►I h--1" Figure 3. Heritage®, Heritage® Premium, and Heritage® Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE COMMON BOND EXPOSURE 5-5/8° 1^� �T-1/2'+�7-1/2°� 7�8°�-7-i/2"-►h-7-1/2"� h—i° Figure 4. Heritage® & Heritage® Premium 6 Nail Pattern This evaluation report is provided for State of Flonda product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical. Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installafion, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC 7-1 1 �7-1/2+7-1/2'7.3/8"-1/2+4/294 Figure 6. Heritage® Woodgate 6 Nail Pattern TAMKO BUILDING PRODUCTS Asphalt Shingles NAIL ZONFJ COMMON BOND Common Bond 3t1.9/8" Figure 6. Heritage®, Heritage® Premium, S Heritage® Woodgate Alternate 6 Nall Pattern raw r C"C r7 10CATION Figure 7. Heritage® (Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 i nis evawatlon report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Heritage® Premium Basic Wind Speed (Vwa: (Frederick) Basic Wind Speed (V,,d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published Installation instructions. Shingles shall be attached using "6 Nall Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. NAIL ZONE/ bOMMON BOND $u Figure 8. Heritage® Premium (Frederick) 4 Nall Pattern (non-HVHZ only) Figure 9. Heritage® Premium (Frederick) 6 Nall Pattern OND TBP15001.4 FL18355-R4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall n Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes specifically addressed herein. 6 of 11 is valid. are not ®CREEK TECHNICAL SERVICES, LLC Heritage® Woodgats Basic Wind Speed (Vuo: (Frederick) Basic Wind Speed (Ve,e): Deck (Non-HVHZ): Underiayment: Min. slope: Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with. FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. 1 --T�nT 7 EXPOSURE r .i 1 ■t 1'I—rl 11e—a-12-3/8'r..... 11" —� 11,41.1" Figure 10. Heritage®Woodgate (Frederick) 4 Nail Pattern (non-HVHZ only) ZONEf NON BOND 1 !i•1/2' EXPOSURE 5' rrt Figure 11. Heritage® Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not .specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Heritage® Vintage® Basic Wind Speed (V jJ: (Phillipsburg) Basic Wind Speed (V.w): Deck (HVHZ): Deck (Non-HVHZ): Undedayment: Min. slope: Installation (HVHZ): Installation (Nan.HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements, Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "5 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 12. Heritage® Vintage® 6 Nail Pattern (non-HVHZ only) Figure 13. Heritage® Vintage® 6 Nail Pattern i ms evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall n Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes specifically addressed herein. 8 of 11 Is valid, are not ®CREEK TECHNICAL SERVICES, LLC Hip & Ridge Basic Wind Speed (V u): (Frederick & Joplin) Basic Wind Speed (Vase): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direado�n of prevailing wind exposure Figure 1 Fastener t5�n Figure 2 Figure 14. Hip & Ridge (Frederick & Joplin) >xposure This evaluation report Technical Services, LLC provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Vintage® Hip & Ridge Basic Wind Speed (V lt): (Phillipsburg) Basic Wind Speed (Vase): Deck (HVHZ): Deck (Non-HVHZ): Undedayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Dlredlo�n of prevailing wind ire Figure 1 :r Fastener Figure 2 Kposure rigure 3 Figure IS. Vintage® Hip & Ridge (Phillipsburg) TBP15001.4 FL18355-R4 p This evaluation report is provided far State of Florida product approval under Rule 61G20-3. The manufacturer shall n Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes specifically addressed herein. of 11 Is valid. are not ®CREEK TAMKO BUILDING PRODUCTS TECHNICAL SERVICES, LLC Asphalt Shingles LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to undedayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 60 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. J%,,GPR'r E R ,S fpR�,���i �p • V\ G ` VV No 74021 Cam: �'. STATE OF �0 N 181111A11 t��A,�p CERTIFICATION OF INDEPENDENCE 2017.09.25 11:31:41 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE11669 CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest In any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. TBP15001.4 END OF REPORT FL 11 oyo �, , evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are n specifically addressed herein. ot