HomeMy WebLinkAboutEVALUATION REPORTTECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer; TAMKO BUILDING PRODUCTS, INC.
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
http://www.tamko.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1
Properties:
Physical properties
PRODUCT DESCRIPTION
TAMKOO ASTM Slate
Surfaced Roll Roofing
TAMKOO ASTM Tile
Underlayment
TAMKO@ Master
Smooth
TAMKO@ Moisture
Guard@
TAMKO@ No. 15 ASTM
Asphalt Saturated
Organic Felt
TAMKO@ No. 15 UL
Asphalt Saturated
Or anic Fel
OO DZ
lt Sic Felt
TAMKOO No. 30 UL
Asphalt Saturated
Organic Felt
TAMKO@ TW Metal and
Tile Underlayment
TAMKO@TW
Underlayment
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, Bra EDITION
SCANNED
BY
St. Lucie County
Issued October 19, 2017
ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
with asphalt and coated on both sides with asphalt and surfaced with granules.
ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with granules.
ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
saturated with asphalt.
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
saturated with asphalt.
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
saturated with asphalt.
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
saturated with asphalt.
Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
with a polymer film on the surface and a removable release film on the adhesive side.
Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS, INC.
°Gtr,{`[ CREEK TAMKO Underlaymenfs
\k , 1!T
"i`/' TECHNICAL SERVICES, LLC
TAMKOO TAM -FELT Alternate to ASTM D 226,'Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50"F except as follows:
a) The minimum application temperature of TAMKOO TW Metal and Tile Underlayment and TAMKOO TW
Underlayment shall be 40"F.
b) The minimum application temperature of TAMKOO Moisture GuardO shall be 35"F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturers recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanical1 fas ned through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof
Mineral
Wood
Asphalt
Panels and
Surfaced Roll
Shingles and
Slate
Clay and
Underlayment
Shinales
Shingles
Roofing
Shakes
Shingles
Concrete Tile
TAM KOO ASTM Slate
Y'
N
N
N
Y
Surfaced Roll Roofing
TAM KOO ASTM Tile
N
N
N
N
N
Underlayment
TAMKOO Master Smooth
Y'
N
N
N
N
N
TAMKOO Moisture Guard(g)
Y
N
N
N
TAMKOO No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y'
N
N
Felt
TAMKOO No. 15 UL Asphalt
Y
Y
Y
Y
N
,.Saturated Organic Felt
TAMKOO No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKOO No. 30 UL Asphalt
Y
Y
N
Y
N
Saturated Organic Felt
TAMKOOTW Metal and Tile
Y
Y
N
N
N
Y
Underlayment
TAM KOO TW Underlayment
Y
Y
N
N
N
TAMKOOTAM-FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4 FL12328-138 Page 2 of 4
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
�lf`C��ffO TAMKO BUILDING PRODCUTS, INC.
CREEK
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be Installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck In a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturers application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
REFERENCES
Entitv
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST6049)
TAP-192-02-01
ASTM D
1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-193-02.01
ASTM D
1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-214-02-01
ASTM D
4869
2016
PRI Construction
Materials Technologies (TST6049)
TAP-215-02-01
ASTM D
226
2009
PRI Construction
Materials Technologies (TST6049)
TAP-216-02-03
ASTM D
6380
2003(2013)
PRI Construction
Materials Technologies (TST6049)
TAP-217-02-01 REV
ASTM D
6380
2003(2013)
PRI Construction
Materials Technologies (fST6049)
TAP-218-02-01
ASTM D
226
2009
PRI Construction
Materials Technologies (TST6049)
TAP-219-02-01
ASTM D
226
2009
PRI Construction
Materials Technologies (TST6049)
TAP-220-02-01
ASTM D
6380
2003(2013)
PRI Construction
Materials Technologies (TSi6049)
TAP-222-02-01
ASTM D
4869
2016
PRI Construction
Materials Technologies (TST6049)
TAP-245-02-01
TAS 103
1995
ASTM D
4798
2011
PRI Construction
Materials Technologies (TST6049) O
TAP-311-02-01
ASTM D
1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-319-02.01.1
ACC 188
2012
PRI Construction
Materials Technologies (TST6049)
TAP-387-02-01
ASTM D
1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-388-02-01
ASTM D
1970
2015a
UL LLC (TST9628)
13CA12269
ASTM D
226
2009
FL12328-R8
of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKhx.
6e
't- TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
��� P •'v,�G E N SF• �s�'•
No 74021
z9 STATE OF
RIP
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
--04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have. nor will It acquire, a financial Interest In any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not ovmed, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any other entity involved In the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
• ! j�l._ M A
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer: TAMKO BUILDING PRODUCTS, INC.
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
http://www.tamko.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, 6T" EDITION (2017)
Issued October 19, 2017
Category: Roofing Subcategory: Underlayments SCANNED
Code Sections: 1507.1.1 BY
Properties: Physical properties St. Lucie County
PRODUCT DESCRIPTION
TAMKOO ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKOO ASTM Tile ASTM D 6380, Class M, Type 11 underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKOO Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOO Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard@ with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKOO No. 15 ASTM ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No. 15 UL ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Or anic Fel
Q
OO No. 30 ASTM ASTM D 226, Type II underlayment constructed from anon -perforated organic felt that is
alt Saturated saturated with asphalt.
nic Felt
TAMKOO No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@ TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO@ TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODCUTS, INC.
- TAMKO Underlayderlayments
TECHNICAL SERVICES, LLC
TAMKO®TAM-FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50T except as follows:
a) The minimum application temperature of TAMKO@ TW Metal and Tile Underlayment and TAMKO(D TW
Underlayment shall be 40"F.
b) The minimum application temperature of TAMKO@ Moisture Guard® shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMK0(DASTM State Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanical) fas,jened through the underlayment to the roof deck.
Allowable Roof Coverinas:
Metal Roof
Mineral
Wood
Asphalt
panels and
Surfaced Roll
shingles and
Slate
Clay and
Underlayment
Shinales
Shin les
Roofing
Shakes
Shingles
Concrete Tile
TAMKO@ ASTM Slate
Y'
N
N
N
Y
Surfaced Roll Roofing
TAMKO@ ASTM Tile
N
N
N
N
N
Underlayment
TAMKO®Master Smooth
Yt
N
N
N
N
OF N
TAMKO@ Moisture Guard@
Y
N
N
N
TAMKO@ No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y'
N
N
Felt
TAMKO@ No. 15 UL Asphalt
Y
Y
Y
Y
N
,.Saturated Organic Felt
TAMKO@ No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKO@ No. 30 UL Asphalt
Y
Y
N
Y
N
Saturated Organic Felt
TAMKO@ TIN Metal and Tile
Y
Y
N
N
N
Y
Underlayment
TAMKO@ TW Underlayment
Y
/YN_
N
N
N
TAMKO@TAM-FELT
Y
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4
FL12328-R8
of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
'tea CREEK TAMKO BUILDINGPROderlay INC.
CREEK TAMKO Underlayments
''- TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses In accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST6049)
TAP-192-02-01
ASTM
D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-193-02-01
ASTM
D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-214-02-01
ASTM
D 4869
2016
PRI Construction
Materials Technologies (TST6049)
TAP-215-02-01
ASTM
D 226
2009
PRI Construction
Materials Technologies (TST6049)
TAP-216-02-03
ASTM
D 6380
2003(2013)
PRI Construction
Materials Technologies (TST6049)
TAP-217-02-01 REV
ASTM
D 6380
2003(2013)
PRI Construction
Materials Technologies (TST6049)
TAP-218-02-01
ASTM
D 226
2009
PRI Construction
Materials Technologies (TST6049)
TAP-219-02-01
ASTM
D 226
2009
PRI Construction
Materials Technologies (TST6049)
TAP-220-02-01
ASTM
D 6380
2003(2013)
PRI Construction
Materials Technologies (TSi6049)
TAP-222-02-01
ASTM
D 4869
2016
PRI Construction
Materials Technologies (TST6049)
TAP-245-02-01
TAB 103
1995
ASTM
D 4798
2011
PRI Construction
Materials Technologies (TST6049) •
TAP-311-02-01
ASTM
D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-319-02-01.1
ACC 188
2012
PRI Construction
Materials Technologies (TST6049)
TAP-387-02-01
ASTM
D 1970
2015a
PRI Construction
Materials Technologies (TST6049)
TAP-388-02-01
ASTM
D 1970
2015a
UL LLC (TST9628)
13CA12269
ASTM
D 226
2009
TBP14001.4 FL12328-138 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
r CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6lh Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
t''FY rR"P����i
GAP
�Q:•�\GE NSF•. S�
No 74021
9 STATE OF .�
:O c 41J:
•� F . 0 R
s3 �O INAII E, .�``�
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest In any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.