HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSJALL AMERICANI ll SHUTTERS & GLASS 1838 D inna Road; West Palm Beach, FL 33409 (561) 712-9882 • www.allamerlcanshutters_eom SCANNED BY St. Lucie County Property Information =11 Building Information Owner: Address: ROTH, STEVEN 3000 N HIGHWAY AlA APT 3D FT PIERCE, FL 34949 Wind Zone: 170 MPH. Exposure Category: D Minimum Building Dimension: 160 ft. Mean Roof Height: 112 ft. Risk Category: III Design Pressure Calculations Opening Number Location Zone Device Width (m) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Ivlax Negative Pressure s 1 Int 80 101.50 82 51.9 -56.0 2 Int 82 51.9 -56.0 3 Int 75 101.15 82 52.2 -56.2 4 Int 82 52.2 -56.2 5 Int 760 101.75 82 41.3 -48.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1 TALL AMERICAN I SHUTTERS & GLASS 1838 Donna Road, West Palm Beach, FL 33409 (561) 712-9882 • wvmallamericanshullers_com Property Information L Building Information 1 Owner: ROTH, STEVEN Wind Zone: 170 MPH. LAddress: 3000 N HIGHWAY AlA Exposure Category: D APT 3D Minimum Building Dimension: 160 ft. FT PIERCE, FL 34949 Mean Roof Height: 112 ft. Risk Category: III Opening Number Pressure Calculations Location Device Device Device Max Positive Max Ne alive Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 80 101.50 82 51.9 -56.0 2 Int 82 51.9 -56.0 3 Int 75 101.75 82 52.2 -56.2 4 Int 82 52.2 -56.2 5 Int 760 101.75 82 41.3 -48.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1