HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSJALL AMERICANI
ll SHUTTERS & GLASS
1838 D inna Road; West Palm Beach, FL 33409
(561) 712-9882 • www.allamerlcanshutters_eom
SCANNED
BY
St. Lucie County
Property Information
=11
Building Information
Owner:
Address:
ROTH, STEVEN
3000 N HIGHWAY AlA
APT 3D
FT PIERCE, FL 34949
Wind Zone: 170 MPH.
Exposure Category: D
Minimum Building Dimension: 160 ft.
Mean Roof Height: 112 ft.
Risk Category: III
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (m)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Ivlax Negative
Pressure s
1
Int 80
101.50 82 51.9
-56.0
2
Int
82 51.9
-56.0
3
Int 75
101.15 82 52.2
-56.2
4
Int
82 52.2
-56.2
5
Int 760
101.75 82 41.3
-48.5
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1
TALL AMERICAN I
SHUTTERS & GLASS
1838 Donna Road, West Palm Beach, FL 33409
(561) 712-9882 • wvmallamericanshullers_com
Property Information L Building Information 1
Owner: ROTH, STEVEN Wind Zone: 170 MPH.
LAddress: 3000 N HIGHWAY AlA Exposure Category: D
APT 3D Minimum Building Dimension: 160 ft.
FT PIERCE, FL 34949 Mean Roof Height: 112 ft.
Risk Category: III
Opening
Number
Pressure Calculations
Location
Device
Device
Device
Max Positive
Max Ne alive
Zone
Width (in)
Height (in)
Elevation (ft)
Pressure (psf)
Pressure (psf)
1 Int 80
101.50 82
51.9
-56.0
2 Int
82
51.9
-56.0
3 Int 75
101.75 82
52.2
-56.2
4 Int
82
52.2
-56.2
5 Int 760
101.75 82
41.3
-48.5
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1