HomeMy WebLinkAboutPROJECT INFORMATIONSCANNED
CEMENT ALL St. Luce County
Multi -Purpose Repair Material & Nan -Shrink Grout
PRODUCT DATASHEET
DESCRIPTION: Rapid Set® CEMENT ALL® is a high-performance, fast -setting, multi-
purpose concrete repair material and non -shrink grout. Durable in wet environments,
CEMENT ALL is a blend of Rapid Set hydraulic cement and specially graded fine
aggregates. CEMENT ALL is non-metallic and no chlorides are added. Mix CEMENT ALL
With water to produce a workable, high qualitymaterial that is ideal where rapid strength
gain and high durability are desired. CEMENT ALL sets in 15 minutes and achieves
structural strength in 1 hour*
USES: Use CEMENT ALL for general and structural concrete repair, doweling and
anchoring, industrial grouting, formed work, vertical and horizontal trowel applications.
CEMENT ALL is ideal for airport, highway, industrial and marine applications.
ENVIRONMENTAL ADVANTAGES: Use CEMENT ALL to reduce your carbon footprint
and lower your environmental impact. Production of Rapid Set cement emits far
less CO2 than portland cement. Contact your representative for LEED values and
environmental information.
APPLICATION: Apply CEMENT ALL in thicknesses from featheredge to 4" (10 cm). For
heavy loads and vehicle traffic, minimum thickness will vary. Not intended for high heat
applications above 300OF (1490C). For deeper sections, use Rapid Seto Mortar Mix or
Rapid Set® Concrete Mix. For overlay applications, a minimum of one test section should
be prepared to evaluate the suitability of the materials and procedures.
SURFACE PREPARATION: For repairs, application surface must be clean, sound and free
from any materials that may inhibit bond, such as oil, asphalt, curing compound, acid,
dirt and loose debris. Roughen surface and remove all unsound material. Apply CEMENT
ALL to a surface that is thoroughly saturated with no standing water.
MIXING: The use of a power -driven mechanical mixer, such as a mortar mixer or a drill -
mounted mixer, is recommended. Organize work so that all personnel and equipment are
in place before mixing. Use clean potable water. CEMENT ALL may be mixed using 3 to
5 quarts (2.8 L to 4.7 L) of water per 55-lb (25-kg) bag. Use less water to achieve
higher strengths. Do not exceed 5 quarts (4.7 L) of water per bag. For increased
fluidity and workability, use Rapid Set° FLOW Control® plasticizing admixture from the
Rapid Set° Concrete Pharmacy9. Place the desired quantity of mix water into the mixing
container. While the mixer is running, add CEMENT ALL. Mix for the minimum amount of
time required to achieve a lump -free, uniform consistency (usually 1 to 3 minutes). Do
not retemper.
PLACEMENT: CEMENT ALL may be placed using traditional construction methods.
Organize work so that all personnel and equipment are ready before placement. Place,
consolidate and screed quickly to allow for maximum finishing time. Use a method of
consolidation that eliminates air voids. Do not wait for bleed water; apply final finish
as soon as possible. CEMENT ALL may be troweled, floated or broom finished. On flat
work, do not install in layers. Install full -depth sections and progress horizontally. Do not
install on frozen surfaces.To extend working time, use Rapid Set° SET Control® retarding
admixture from the Concrete Pharmacy or cold mix water. CEMENT ALL may be applied
in temperatures ranging from 450F to 90OF (7°C to 320C).
Rapid Sef
OVERVIEW
Highlights:
Fast: Sets in 15 minutes, structural strength
in 1 hour'
Durable: Formulated for long life
in critical applications
Excellent Bond: Superior adhesion to concrete,
stone, brick, block, stucco and more
Structural: For repair and new construction
Multi -Purpose: Use for concrete repair, grouting,
anchoring, casting, underlayment and more
Conforms to:
ASTM: C1107, C928, C387 and CRD C621
Army Corps of Engineers
LA Research and Report 24654
State and Local Approvals
MasterFormat® 2016
03 01 30
Maintenance of Cast -in -Place Concrete
0301 40
Maintenance of Precast Concrete
0301 60
Maintenance of Grouting
0301 70
Maintenance of Mass Concrete
035319
Concrete Overlayment
0354 16
Hydraulic Cement Underlayment
03 60 00
Grouting
0361 00
Cementitious Grouting
036213
Non -Metallic Non -Shrink Grouting
0401 00
Maintenance of Masonry
Manufacturer:
CTS Cement Manufacturing Corp.
12442 Knott St.
Garden Grove, CA 92841
Tel: 800-929-30301 Fax: 714-379-8270
Web: www.CTScement.com
E-mail: into®CTScement.com
RaplASot r
CEMENU4LL
-Yll4MM1� �bW YI[YW �N• W4���Yf
Q')
CEMENT ALL Multi -Purpose Repair Material & Non -Shrink Grout
CURING: Water cure all Rapid Set® CEMENT ALL® installations by keeping exposed
surfaces wet for a minimum of 1 hour. Begin curing as soon as the surface starts to
lose its moist sheen. When experiencing extended setting time due to cold temperature
or the use of retarder, longer curing times may be required. The objective of water
curing shall be to maintain a continuously wet surface until the product has achieved
sufficient strength.
COLD WEATHER: Environmental and material temperatures below 70OF (21 °C) may delay
setting time and reduce the rate of strength gain. Lower temperatures will have a more
pronounced effect. Thinner sections will be more significantly affected. To compensate
for cold temperatures, keep material warm, use heated mix water, and follow ACI 306
Procedures for Cold Weather Concreting.
WARM WEATHER: Environmental and material temperatures above 70OF (21°C) may
speed setting time and increase the rate of strength gain. Higher temperatures will have
a more pronounced effect. To compensate for warm temperatures, keep material coal,
use chilled mix water, and follow ACI 305 Procedures for Hot Weather Concreting. The use
of Rapid Set® SET Control retarding admixture from the Rapid Set® Concrete Pharmacy
will help offset the effects of high temperatures.
YIELD & PACKAGING: CEMENTALL is available in 55-lb, 25-lb and 10-lb (25-kg,11.3-kg
and 4.5-kg) sizes. One 55-lb (25-kg) bag of CEMENT ALL will yield approximately 0.5 ft.
SHELF LIFE: CEMENT ALL has a shelf life of 12 months when stored properly in a dry
location, protected from moisture, out of direct sunlight, and in an undamaged package.
USER RESPONSIBILITY: Before using CTS products, read current technical data sheets,
bulletins, product labels and safety data sheets at www.CTScement.com. It is the user's
responsibility to review instructions and warnings for any CTS products prior to use.
WARNING: 00 NOT BREATHE DUST. AVOID CONTACT WITH SKIN AND EYES. Use
material in well -ventilated areas only. Exposure to cement dust may irritate eyes, nose,
throat, and the upper respiratory systemAungs. Silica exposure by inhalation may result
in the development of lung injuries and pulmonary diseases, including silicosis and lung
cancer. Seek medical treatment if you experience difficulty breathing while using this
product.The use of a NIOSH/MSHA-approved respirator (P-, N- or R-95) is recommended
to minimize inhalation of cement dust Eat and drink only in dust -free areas to avoid
ingesting cement dust Skin contact with dry material or wet mixtures may result in
bodily injury ranging from moderate irritation and thickening/cracking of skin to severe
skin damage from chemical bums. If irritation or burning occurs, seek medical treatment.
Protect eyes with gaggles or safety glasses with side shields. Cover skin with protective
clothing. Use chemical resistant gloves and waterproof boats. In case of skin contact
with cement dust, immediately wash off dust with soap and water to avoid skin damage.
In case of skin contact with wet concrete, wash exposed skin areas with cold running
water as soon as possible. In case of eye contact with cement dust, flush immediately
and repeatedly with clean water, and consult a physician. If wet concrete splashes into
eyes, rinse eyes with clean water for at least 15 minutes and go to the hospital for
further treatment.
Please refer to the SDS and www.CTSeement.com for additional safety information
regarding this material.
LIMITED WARRANTY: CTS CEMENT MANUFACTURING CORP. (CTS) warrants its materials
to be of good quality and, at its option, will replace or refund the purchase price of any
material proven to be defective within one (1) year from date of purchase. The above
remedies shall be the limit of CTS's responsibility. Except for the foregoing, all warranties
expressed or implied, including merchantability and fitness for a particular purpose, are
excluded. CTS shall not be liable for any consequential, incidental, or special damages
arising directly or indirectly from the use of the materials.
A WARNING
CANCER and REPRODUCTIVE HARM - www.P65Wamings.ca.gov
CTSGawn1MwtAacbmng Cory. 112442fttt St,Gardea Gm .GA92841 1800-929-3030 I nwnw.Mmnce ntwm
O
TYPICAL PHYSICAL DATA
Set Time, ASTM C191 Mod.
Initial set 15 minutes
Final set 35 minutes
Compressive Strength, ASTM C109 Mod.
1 hour' 3000 psi (20.7 Maa)
3 hours 5000 psi (34.5 Maa)
24 hours 6000 psi (41.4 Maa)
7 days 7000 psi (48.3 MPa)
28 days 9000 psl (62.1 MPa)
Slant Shear Bond, ASTM C882 per C928
24 hours 1500 psi (10.3 Mao)
28 days 2500 psi (172 Mao)
Splitting Tensile, ASTM C496
7 days 700 psi (4.82 Maa)
28 days 880 psi (6.o6 Moat
Flexural Strength, ASTM C78
7 days 600 psi (4.14Maa)
28 days 800 psi (5.51 Maa)
'Aftuftalset
Data obtained at flow consistency 102 by ASTM C1437
All data aaduced at 70-F (21-Q
I�nLN i4m,YP Y,vVaw\aeep,M UB f
a.VN aaov3 vtl Y �, p nrm4n