Loading...
HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE CGUN1 f Y FIRE DIS i RICT Fe PLAN REVIEW FORM N AI Milner Drive t511 t 5166 1 i1 Port SAnt Lucie, FL 34983 Telephone: 772-621-3322 `DISt.4'�r fax: 772-621-3604 Web Address; www.slcfd.com Building Dept sLc s FMO Permit # 6-19-255 Project Name House of Winners Y v i.. BLDG:Permit# 1905-0051 -Address 7173 South US Hwy I _ City p5L A d Contractor DW Residential - Address 11807 Lakefrcnt Blvd City Ft Pierce .State. FL Zip r4932 —^•- Telephone 237-1248T --~ Architect/Engineer DFI Engineering -_ Telephole (,i21i 727700 Occupancy Type Assembly Construction Type illB , Square Feet F�—` IE r- .v OccupantLoad r601 perp!an5 Numborof Stories jl Access Box Required Access Key Switch AFSPermit Required FAPermit ;Required FFP Permit w General Notes 1. An electronic copy of the construction documents submitted on a CD is required. she file format shall be.pdf only. 2. All revisions, including the electronic copy must he received prior to permitting. 8. The Fire Marshal requires 24 hour notice on all inspectiom. 4.'The respective Building Department shall schedule all final Inspections through tt.e Fire Marshal's Office. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the. proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. 8. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC systenits that exceed 2,000 cfm design capacity, 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire protection Systems require a separate review and. permit. THE FLORIDA FIRE PREVENTION CODE, 2015 EOITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARRED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.412AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required Revisions Below 1. A separate review and c>erin * is required for the installation or alteration of the fire alarm and fire sprinkler systems. 2. Assembly occupancies with an occupant load greater than 100 persons require panic hardware or fire exit hardware on the required means of egress doors. 3. Automatic fan shutdown is required fur HVAC system/,that exceed 2.000 cfm design capacity. Provide a remote test and inspect appliance equipped with anaudible/visual indicator for each HVAC duct rmokedetector. HVAC duct smoke detector(s) shall be tied into the fire alarm system. *"*Fire Alarm System shalt be of voice evacuation *** Page ri of 5 Beuleuredhy }YDny'lerger Date 09-05.2019