Please note that some coordination changes are being issued along with the changes required to
satisfy the comments below. Said changes required the energy calculations to be revised. Please find
them attached along with the revised plans and this letter.
Comments: SCANNED
Documents Missing: BY
St. Lucie County
1. Notice of Commencement
RESPONSE: Noted. Plan expediter shall submit when available.
2. Please provide sub agreements for electric, plumbing and mechanical. Front counter please input into
computer.
RESPONSE: Noted. Plan expediter shall submit when available.
Mechanical Review:
1. NO NOA PROVIDED FOR NEW ROOFTOP STAND, PROVIDE NOA# ON THE DRAWINGS. (301.15 WIND
RESISTANCE)
RESPONSE: The Florida Approval Number has been added to the drawing and the installation drawing is
attached. Please refer to the HVAC Roof Plan on sheet M-2
2. ROOF STAND HEIGHT NOT PROVIDED. ROOF MOUNTED MECHANICAL UNITS SHALL BE MOUNTED ON
CURBS RAISED A MINIMUM OF 8 INCHES ABOVE THE ROOF SURFACE, OR WHERE ROOFING MATERIALS
EXTEND BENEATH THE UNIT, ON RAISED EQUIPMENT SUPPORTS PROVIDING A MINIMUM CLEARANCE
HEIGHT IN ACCORDANCE WITH (TABLE 1510.10)
RESPONSE: The clear height of the stand has been added Please refer to the HVAC Roof Plan on sheet
M-2
3. SMOKE DETECTOR IS SHOWN IN THE RETURN. PER (606.2.1) A DETECTOR APPROVED FOR AIR DUCT
USE SHALL BE INSTALLED ON THE SUPPLY SIDE OF AIR -HANDLING SYSTEMS AS REQUIRED BY NFPA 90A,
pg. 1
1905-0343 — One Plant, Port Saint Lucie, FL [ BD Comments - Response letter 1 10/08/2019
STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS. SMOKE
DETECTORS LISTED FOR USE IN AIR DISTRIBUTION SYSTEMS SHALL BE LOCATED DOWNSTREAM OF THE
AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTIONS IN AIR SUPPLY SYSTEMS HAVING THE
CAPACITY GREATER THAN 2000 CUFT/MIN.
RESPONSE: An additional smoke detector is now shown in RTU-2 (RTU-1 is not over 2,000 CFM) and
Note B in the Mechanical Notes has been modified to require this. Please refer to the HVAC roof plan
on sheet M-2 and the Mechanical Notes on sheet M-1
4. RETURNS MISSING FROM THE CONSULTATION OFFICE & BACK OF HOUSE. (601.6)
RESPONSE: See correction on HVAC plan, M-1. Returns for consultation office & back of house are now
present.
5. ROOF HEIGHT & ACCESS IS NOT CLEAR ON THE PLANS, PLEASE CLARIFY. (306.5)
RESPONSE: Roof height and location of existing roof access has been added to the HVAC Roof Plan on
sheet M-2
6. NEW ROOFTOP CONDENSER APPEARS LESS THAN 10' FROM ROOF EDGE. VERIFY GUARDS ARE
PROVIDED. ([BE] 304.11
RESPONSE: The roof has a 6' high parapet all around. This is now noted on the HVAC Roof Plan on sheet
M-1
pg. 2
av�
e
ARCHITECT. PA.
RECEIVED
JUL 0 3 2019
ST. Lucie County, Permitting
3330 NE 34 St.
Ft Lauderdale, FI. 33308
Office 954.566.5051
www.laskyarchitect.com
TO:.
DATE:
CITY OF PORT St. LUCIE
07/02/2019
BUILDING DEPARTMENT
PROJECT:
PERMIT/PROCESS #:
Zen Leaf
1905-0343
ADDRESS:
DISCIPLINES:
7510 US 1
Documents Missing, Plumbing, Plans Examiner
PORT St. LUCIE. FL 34953
Comments:
Documents Missing:
1. Notice of Commencement
RESPONSE: Noted. Plan expediter shall submit when available.
2. Please provide sub agreements for electric, plumbing and mechanical. Front counter please input into
computer.
RESPONSE: Noted. Plan expediter shall submit when available.
Plumbing:
1. Need To Show Hi/Low Drinking Fountain Per Table 403.1 And 410 Of The Florida Plumbing Code 6th
Edition 2017
RESPONSE: There is an existing Hi/Low Drinking Fountain in place that shall remain. See CS-3, keynote
20.
Plans Examiner Review:
1. The property appraiser has the base area of 2,908 square feet on record. Please update drawings and
occupant count as required. ([A] 107.2.1)
RESPONSE: See revised occupancy load calculations and plumbing calculations on CS-1 & life safety plan
on LS-1.
2. Life safety plan- please provide the travel distance from the most remote point. This appears to in the
office, verify on drawings. (A] 107.2.3)
RESPONSE: Travel distance has been revised to show path form the office. See revised LS-1.
pg. 1
1905-0343 — Zen Leaf, Port Saint Lucie, FL ) BD Comments - Response letter ) 07/02/2019
3. Provide maneuvering clearances at doors at breakroom cabinets & restrooms. (FBC, E1006.1)
RESPONSE: See door & cabinet clearances on CS3.
4. Please provide accessible restrooms. (FBC, E 1006.1)
RESPONSE: Our office inspected the space. The existing restrooms are fully accessible and up to code.
See CS-3.
pg. 2
A e
ARCHITECT, P.A.
3330 NE 34 St.
RECEIVED
Ft Lauderdale, FI.33308
SCANNED AUG 15 1010
BY Office 954.566.5051
Permitting Department
St. Lucie County St. Lucie County www.laskyarchitect.com
TO: DATE:
CITY OF PORT St. LUCIE 08/12/2019
BUILDING DEPARTMENT
PROJECT: PERMIT/PROCESS #:
One Plant ,.473WW
ADDRESS: DISCIPLINES:
7510 US 1 Documents Missing, Plans Examiner
PORT St. LUCIE. FL 34953
Please note that some coordination changes are being issued along with the changes required to
satisfy the comments below. Said changes required the energy calculations to be revised. Please find
them attached along with the revised plans and this letter.
Comments:
Documents Missing:
1. Notice of Commencement
RESPONSE: Noted. Plan expediter shall submit when available.
2. Please provide sub agreements for electric, plumbing and mechanical. Front counter please input into
computer.
RESPONSE: Noted. Plan expediter shall submit when available.
Plans Examiner Review:
3. PROVIDE MANEUVERING CLEARANCES AT DOORS AT BREAKROOM CABINETS & RESTROOMS. (FBC, E
1006.1)
**BATHROOM DOOR MANEUVERING CLEARANCE- 12" REQUIRED FOR PUSH SIDE ON A DOOR WITH
ACLOSER.**
RESPONSE: Per FPC 2017 403.2, Exception 3: "Separate facilities shall not be required in mercantile
occupancies in which the maximum occupant load is 100 or fewer". In compliance with this exception,
both restrooms have been designated as unisex. One of the existing restrooms has been modified for
full compliance with the current accessibility code, including the door approaches. Please see CS-3.
4. PLEASE PROVIDE ACCESSIBLE RESTROOMS. (FBC, E 1006.1)
**SEE SECTION (404.2.4) OF THE ACCESSIBILITY CODE FOR MANEUVERING CLEARANCES AT DOORS. 12"
REQUIRED FOR PUSH SIDE ON A DOOR WITH A CLOSER.
RESPONSE: See response to comment 3 above.