Product Manufacturer
Sunlast Metal
Address/Phone/Email
2120 SW Poma Drive
Palm City, FL 34990
(772) 223-4055
FILE
Flvalidati on@yahoo.ahoo.co
C
Authorized Signature Terry Kapron l ^O�57�
Flerry Kapron hoo.com REVIEWED (`� g�
Technical Representative FOR
Address/Phone/Email CODE COMPLIANCE
Quality Assurance Representative ST. LUCIE CO�I�IaT♦Y
Address/Phone/Email ®OCC
Category Roofing ,
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Diane G. Marotta, P.E.
the Evaluation Report
Florida License PE-82591
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 03 026
Validated By Locke Bow en P.E.
Il Validation Checklist - Hardcopy Received
Certificate of Independence FL21473 R3 COI SUNI AST METAL REV odf
Referenced Standard and Year (of Standard) Standard Year
TAS 100 1995
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/20/2018
Date Validated 06/20/2018
Date Pending FBC Approval 06/28/2018
Date Approved 08/15/2018
Summary of Products
FL #
Model, Number or Name
Description
21423.1
JAX BEACH SERIES CLIPLESS SNAP
1.5 24GA 15-19" WIDTHS OVER 15/32" 4-PLY CDX PLYWOOD
LOCK
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161PSF
Other:-161PSF@3"0.C.,-97.25PSF@6"0.C. INSTALL PER
MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH FBC
Installation Instructions
FL21423 R3 11 FL21423 1 ]AX BEACH Se 'es-CLIPLESS
SNAPLOCK 24GA-sss.odf
Verified By: Diane G. Marotta, P.E. 82591
Created by Independent Third Party: Yes
Evaluation Reports
FL21423 R3 AE 171,21423 I-JAX BEACH Series-CLIPLESS
SNAPLO K 4 A-sss odf
Created by Independent Third Party: Yes
2017.
21423.2
JAX BEACH SERIES CLIPLESS SNAP
1.5 ALUMINUM .032 SL 15-19" WIDTHS OVER 4-PLY CDX
LOCK ALUM
PLYWOOD
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--108.5
Other:-108.5psf@3"O.C.,-76.75@6"O.C. INSTALL PER
MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH FBC
Installation Instructions
FL21423 R3 11 ]ax Bea h 0.32 ALUM SNAP LOCK BINDER -
ismdi
Verified By: Diane G. Marotta, P.E. 82591
Created by Independent Third Party: Yes
Evaluation Reports
FL21423 R3 AE Jax Bach 0.32 ALUM SNAP LOCK BINDER-
ss.odf
Created by Independent Third Party: Yes
2017.
21423.3
MIAMI SERIES SNAP LOCK 1.75
24GA 14-18 WIDTHS OVER 15/32" APA PLYWOOD
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.75
Other:-114.25PSF @I6"O.C.,-156.75PSF @8"O.C. INSTALL
PER MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH
Installation Instructions
F1 21423 R3 IT FL21423.3-SS-MIAMI SERIES 24GA SNAP
I OCK 1.75 COMPLETE with detalls.odf
Verified By: Diane G. Marotta, P.E. 82591
Created by Independent Third Party: Yes
Evaluation Reports
FL21423 R3 AE FL21423 3 SS MIAMI SERIES 24GA SNAP
LOCK 1.75 COMPLETE with detalls odf
Created by Independent Third Party: Yes
FBC 2017.
21423.4
MIAMI SERIES SNAP LOCK 1.75
.032 ALUMINUM 14-18 WIDTHS OVER 15/32" APA PLYWOOD
ALUM
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-114.25
Installation Instructions
FL21423 R3 II FL21423 4-SS-MIAMI SERIES SNAP LOCK
1,75 ALUM 0,032 COMPLETE WITH DETAILS odf
Verified By: Diane G. Marotta, P.E. 82591
Created by Independent Third Party: Yes
Other: -110.5PSF@12"O.C.-114.25PSF@6"O.C. INSTALL
PER MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH
Evaluation Reports
FL21423 R3 AE FL21423 4-SS-MIAMI SERIES SNAP LOCK
1.75 ALUM 0,032 COMPLETE WITH DETAILS odf
Created by Independent Third Party: Yes
FBC 2017.
21423.5
PALM BEACH SERIES MECHANICAL
24GA 12 - 20" WIDTHS OVER 15/32" 4-PLY CDX PLYWOOD
LOCK 1.5
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-112PSF
Other: Method 1-90 DEGREE SEAM-93.5psf 24"O.C. Method
2-90 DEGREE SEAM-101PSF 6" O.C. Method 3-180 DEGREE
Installation Instructions
F1.21423 R3 II FL21423 S-SS-PALM BEACH SERIES 1.5
MECHANICAL LOCK -COMPLETE WITH DETAILS odf
Verified By: Diane G. Marotta, P.E. 82591
Created by Independent Third Party: Yes
Evaluation Reports
FI 21423 R3 AE FL21423 5 SS PALM BEACH SERIES 1 5
MECHANICAL LOCK -COMPLETE WITH DETAILS odf
Created by Independent Third Party: Yes
SEAM-112psf 6"O.C. Fasteners per Clip: 2 INSTALL PER
MANUFACTURER'S INSTALL DETAILS IN COMPLIANCE WITH
FBC 2017
21423.6
PALM BEACH SERIES MECHANICAL
.032 ALUM 16 OR 20" WIDTHS OVER 15/32- 4-PLY CDX
LOCK 1.5 ALUM
PLYWOOD
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131PSF
Other: METHOD 1- 90 DEGREE SEAM-63.SPSF 24"O.C.
Installation Instructions
FL21423 R3 11 SUNLAST METAL REV odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL21423 R3 AE SUNLAST METAL REV df
METHOD 2- 90 DEGREE SEAM-86PSF 6"O.C. METHOD 3-
Created by Independent Third Party: Yes
131PSF 180 DEGREE SEAM-6"O.C. 2 FASTENERS PER CLIP
INSTALL PER MANUFACTURER'S INSTALL DETAILS IN
COMPLIANCE WITH FBC 2017
21423.7
SERIES - KEY WEST 5 V CRIMP
26GA 24"WIDTH 3/8" RIB OVER 15/32" APA PLYWOOD
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FQ1423 R3 11 EL 21423N METAL 5 V CRIMP -
ss s.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Diane G. Marotta, P.E. 82591
Design Pressure: +N/A/-189.25
Created by Independent Third Party: Yes
Other:-189.25PSF@8"O.C.,-78.5PSF@16"O.C. THRU
Evaluation Reports
FASTENED. INSTALL PER MANUFACTURER'S INSTALL DETAILS
FL21423 R3 AE FL 21423 SUNLAST METAL 5 V CRIMP -
559.,0df
IN COMPLIANCE WITH FBC 2017
Created by Independent Third Party: Yes
21423.8
SERIES - STUART LINE NAIL
1.0 24GA NAIL STRIP/SNAP LOCK 16" COVERAGE WIDTH
STRIP/SNAP LOCK
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL21423 R3 11 F 4 .0 SERIES STUARTIN
Nail Strip -Snap Lock -HVHZ-COMPLETE WITH DETAILS Ddf
Approved for use outside HVHZ: Yes
Verified By: Diane G. Marotta, P.E. 82591
Impact Resistant: N/A
Design Pressure: +N/A/-136.75
Created by Independent Third Party: Yes
Other:-136.75PSF @ 6"O.C.,-84.25PSF @ 12" O.C.
Evaluation Reports
INSTALL PER MANUFACTURER'S INSTALL DETAILS IN
FL21423 R3 AE FL21423 B-SS-1.0 SERIES - STUART LINE
Nail Strip -Snap Lock -HVHZ-COMPLETE WITH DETAILS.pdf
COMPLIANCE WITH FBC 2017
Created by Independent Third Party: Yes
eatl Nert
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Flodda N an WEED employer. Copyright 2007-2013 State of Florida.:: Pdvacv Statement :: Accessibility Statement :: Refund Statement
Under Flodda law, email addresses are pudic records. If you do not want your e-mail address released in response to a publicremrds request, do not Send electronic
mail to Nis entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1),
Florida StaNtes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The Smalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. T4 determine If you are a licensee under Chapter 455, F.S., please thick bm-.
Produce Approval Accepts:
® = N�A RE
EMPOT-1411IF0
A
r w 'w ww w
al-OR�ID� ¢PE20DUCT' APPR�L3\t�l\L°�°�'
-.STUARTT-11NE SER NAILv •,"
A- 16"AOOF PANEL PLYWQOO'
KT
Product Evaluation Report
1.0 Nail StriP/Snaplock Seam Roof Panel over 15132" Plywood
Florida Product Approval # 21423.8
Florida Building Code 2017 6th ed
Per Rule 61G20.3 Method: I —o
Category: Roofing Subcategory: Metal Roofing Compliance Method:
Rule 61G20.3
HVH2
Product Manufacturer.
Sunlast Metal
21205W Perna Drive
Palm City. Florida 34990
Engineer Evaluator
Diane G. Marotta, P.E. FL reg N
82591
1915 NE45m5T.0107
Fort Lauderdale, FL 33308
954.776-8004
Validator:
Locke Bowden, P.E., FL 049704
9450 Alysbury Place
Montgomery, AL 36117
Diane G. Marotta, P.E.
FL reg N 82591
seal
Page 1 of 4
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1507.1.1, 1507.4.3, 1518.9, 1523.6.5.2.4
Product Description: 24GA Panel,16" Nail Strip/snap lock mechanical attached
16" Coverage Width Roof panels 1.0" Rib height
Panel thru fastened; into 15/32" APA Plywood decking. Non-structural Application.
FOR USE IN HVHZ.
Material: 24GA Steel, Galvalume conforming to Florida Building Code 2017 Section 1507.4.3
56ksi yield strength min. Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3
and Section 1517 for HVHZ
Fastener: #10 X 1" Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support. Corrosion
Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Sealant: Bostick Chem Calk 915 (Silyl modified polymer (SMP) apply 1/16" bead atop rear leg of male joint, adjacent to fasteners
continuously along entire length of panel.
15/32" APA plywood, plywood supports at maximum 24' O.C. Design of plywood and plywood supports are outside the scope of
this evaluation. Must be designed in accordance w/ Florida Building Code 2017 and RAS 133.
TABLE A Safety factor of 2:1 included
Design Pressures
Field
Perimeter/Corner
Max Design Pressure
-84.25psf
-136.75psf
Fastener Spacing
12" o.c.
6" o.c.
Fastener Size
#10
# 10
Insulation: Optional Rigid Insulation board, 3" max thickness compliant with FBC 2017 section 1508.2
Quality Assurance: In accordance with FBC 2017 and Rule # 61620-3: Keystone Certification, Inc. QUA 1824
Test References: Hurricane Test Laboratory (TST1527) 0412-0306-06 RA TAS 125-2003
Architectural Testing Inc (TST 1527) # 0412-1203-07 and 0412-0621-07 TAS 125-2003
Architectural Testing Inc. (TST 1527) C6413.01-450-18 REV 1 TAS 125-2003
PRI Construction Material Technologies(TST5878) SFMS-002-02-01 R3 TAS 100-1995
PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 ASTM B 117-2002
PRI Construction Material Tech nologies(TST5878) AKZC-001-02-01/05 TAS 110-2000
AKZO Nobel Coatings, Inc. Lab Form ASTM G 153
Code Compliance: The product described herein demonstrated compliance with The Florida Building Code (FBC) 2017 Section
1504.3.2., 1523.6.5.2.4.1. The product evaluation is limited to compliance with the structural wind load requirements of the FBC
2017, as relates to Rule 61G20-3.
Minimum Slope Range 2/12 Minimum Slope per Florida Building Code 2017, and in accordance with Manufacturers
recommendations.
Installation: Install per manufacturer's recommended details in compliance with FBC 2017 and RAS 133
Underlayment: Per Manufacturers installation guidelines per Florida Building Code 2017, Chapter 1507 Chart 1507.1.1
Roof Panel Fire Classification: No classification.
Shear Diaphragm: values are outside the scope of this report.
Page 2 of 4
Design Procedure: Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the
Florida Building Code 2017 -roof cladding wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. Design professional shall select the applicable erection details to reference in drawings for
correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be
compliant with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
Required wind loads shall be determined per project per FBC 2017 and any rational analysis computation shall be prepared by a
licensed design professional.
Certificate of Independence: Diane G. Marotta, P.E. does not have nor will acquire financial interest in any company
manufacturing or distributing products under this evaluation. Diane G. Marotta, P.E. is not owned or operated or controlled by
any company manufacturing or distributing product under this report.
PRODUCT EVALUATION REPORT
Page 3 of 4
;5',unlast Meta/
Value Engineered Meta/ Roofing Tm
STUART LINE SERIES(NAILqSTRIP/ SrNAP LOCK
TABLE A #10 X 1" Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support
Roof Areas
Field Perimeters and Corners
Maximum Design Pressures -84.25psf
Screw Spacing
12" o.c.
-136.7S psf
6" o.c.
INSTALLATION METHOD
DRAWINGS
TYPICAL ASSEMBLY PROFILE VIEW
16"
Striations Optional
TYPICAL ASSEMBLY ISOMETRIC VIEW
hew.
q" Bead of Bosfik
Chem-Cautk 915
atlhe.W. .
Feet.... spacing
as per TableA
here!.
Page 4 of 4
B�usitisoessional Reu one ` ; A
� a'9 � • �",� _ ' w.kx+>as ✓aw�~a�' .ratlAoroern
Ronda
'�? `$a Product Approval
"0 USER: Public User
aim ProductAonrovalMenu>ProdudarAoolim"nsearch >Aooltratlonllat>ApplicenonDetail RECEIVED
FL # FL16342-R2 MAY :� `� r'
Application Type Revision
Code Version
Application Status Approved Detail[
Lucie County. Permirting
Comments SCANNED
Archived ❑ BY
St. Lucie County
Product Manufacturer Drexel Metals, Inc.
Address/Phone/Email 204 Railroad Drive
Nyland, PA
rexm FILE COPY
(502) 303-1511
jshumate@drexmet.com
Authorized Signature Jason Shumate e nO / iti/f�
jshuma[e@drezmet.com (��—/vl✓h C/
Technical Representative REVIEWED FOR
CODE COMPLIANCE Quality Assurance Representative STa LUCIE CO
y
Y
Address/Phone/Emall BOCC/r
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Blren P.E.
El Validation Checklist - Hardcopy Received
Certificate of Independence FL16342 R2 COI DRX13004 2 2017 FBC Evaluation Report MetShield
FINAL.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/15/2017
Date Validated 09/18/2017
Date Pending FBC Approval 09/20/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
16342.1
MetShield
ASTM D 1970 self -adhering roofing underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No �Vf7,AVt
FL36342 R2 II DRX33004 2 2017 FBC Evaluation Report
MetShield FINAL.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use
Evaluation Reports
FL16342 R2 AE DRX13004 2 2017 FBC Evgljigtign Report
MetShield FINAL.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road Tallahassee IT 32399 Phone: 850-487-1824
The State of Flonda is an AA/EW employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
II addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
id, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.'Pumuant to Section 455.275(1),
e October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
r official communication with the licensee. However email addresses are public record. If you do not wish W supply a personal address, please
with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click hem .
product Approval Accepts:
® F 0
st'Gtin, t�-, cg"Rres,
CREEKi �1K' Certificate of Authorization No. 29824
.��I I 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6" EDITION
Manufacturer:
DREXEL METALS, INC. Issued September 14, 2017
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
www.drexmet.com
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Undedayments
Code Sections:
1507.1.1, 1507.2.4
Properties:
Physical properties
REFERENCES
Entity
Report No. Standard Year
TrinityJERD (TST6049)
C41280.10.12 ASM970 2015a
ICC-ES (EVL2396)
ESR-2206 ASTM D 1970 2015a
PRODUCT DESCRIPTION AND APPLICATION
'
MetShield
MetShield is a coated-polyolefin-composite film surfaced, self -adhered ASTM D 1970
underlayment for use on steep slope roofs.
Deck Type:
Solid or closely fitted plywood sheathing for new or existing
construction. Plywood deck shall be installed in accordance
with FBC requirements. Roof decks shall have no more than
t/a" gap at abutfing joints.
Min. slope:
In accordance with FBC requirements
Attachment method:
Underlayment shall be attached in accordance with the FBC
Table 1507.1.1 and manufacturer's installation instructions.
Min. application temperature:
40°F. Contact the manufacturer when installing at temperatures
below 40°F.
Allowable roof coverings: Permitted to be used as prescribed in FBC Table 1507.1.1 with
mechanically fastened roof coverings.
DRX13004.2 FL16342-R2 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C R E E n' DREXEL METALS, INC.
n MetShield
TECHNICAL SERVICES, LLC
LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) MetShield may be used as described in other current FBC product approval documents.
7) MetShield shall not be used with adhered tile roof coverings nor installed over existing roof coverings.
8) MetShield shall be exposed on the roof deck for a maximum duration of 30 days.
9) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6v' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
t111111111111
E N
No 74021
PO: STATE OF
ORtOP
CERTIFICATION OF INDEPENDENCE
2017.09.14
16:26:20
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
DRX13004.2 FL16342-R2 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.