HomeMy WebLinkAboutPRODUCT APPROVAL' • Florida Building Code Online
Page 1 of 1
d
Florida
bpr
BCIS Home 1 Log In 1 User Registration ( Hot Topics
a c44 Product Approval
DSeR: Public User
�1
4:
i4
p bepp,p Till 11 q Roi'ai.cd b
Product Approval Menu > Product or Application Search > Application List s
yr i7 C1 Lam® O
(��V
CODE COMP aANCE
Search Criteria
COUNTY
Refine Search
STo LUCRE
�ABNOCCO
Code Version
2017
FL#
16412
Application Type
ALL
Product Manufacturer
ALL
Category
ALL
Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Name
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact Resistant
ALL
Design Pressure
ALL
Other
ALL
Search Results - Aoollcations
FL#
Tyne
I Manufacturer
Validated By
Status
FL16412-R4
Editorial Change
Eastern Architectural Systems
Category: Windows
Subcategory: Single Hung
National Accreditation & Management Institute
(804) 684-5124
Approved
History
-Approved py DIs'R. Approvals Dy 08PR shall be reviewed and re00ed by the
necessary.
Contact us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EED employer. Copyright 2007-2013 State of Florida :: Privacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. if you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. if you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here.
product Approval Accepts:
® ® A M
� 1
MELLOW
11 securityAIETRICS'
SCANNED
BY
St. Lucie County
https://www.floridabuilding.org/pr/pr_app_lst.aspx 6/3/2019
5/15/2016 Florida Building Code Online
Date Submitted 06/12/2018
Date Validated 06/14/2018
Date Pending FBC Approval
Date Approved 06/19/2018
ummary f Products
FL St
Model, Number or Name
Description
16412.1
176 Vinyl Impact Single Hung
176 Vinyl Impact Single Hung
Ltmi of Use
Certification Agency Certificate
—AlYproved for use In HVHZ: Yes
FL16412 R4 C CAC NI012195-Rif
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2024
Design Pressure: N/A
Installation Instructions
Other: Design Pressures are as follows: Fin Window
FL16412 R4 II 08-02538B .pdf
+70.0/-85.Opsf, Flange Window+70.0/-85.0psf. Maximum Size:
Verified By: Louis R. Lomas, P.E. 62514
54" x 77". Frame Material to be Rigid PVC From Deceuninck
Created by Independent Third Party: Yes
North America AAMA Certified (DEP-1). GLASS INTERLAYER
Evaluation Reports
COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA
F1,16412 R4 AE 5133115,pd
BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY
Created by Independent Third Party: Yes
INTERLAYERS
16412.2
Series HD2451/Series HD2461 Single
Series HD2451/Series HD2461 Vinyl Impact Single Hung
Hung
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: No
FL16412 R4 C CAC NI011536-Ili
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
09/30/2024
Design Pressure: +65.0/-65.0
Installation Instructions
Other: Maximum Size: 44" x 84", Nailing Fin or Flange Frame.
F1.16412 R4 rI 08-01933A.Ddf
Frame Material to be Rigid PVC From Deceuninck North America
Verified By: Luis R. Lomas, P.E. 62514
AAMA Certified (DEP-1)
Created by Independent Third Party: Yes
Evaluation Reports
FU6412 R4 AE 512641A.Ddf
Created by Independent Third Party: Yes
aack Next
Contact Us :: 2601 elalr Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The state of Florlda Is an AA/EEO employer. copyright 7007-2013 State of Florida.:: privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to secure 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. h determine If you am a licensee under chapter 455, F.S., please dick hem .
product Approval Accepts:
® ® ® F
Credit Card
Safe
httpsllfloridabuilding.org/prlpr app_d8.aspx?param=wGEVXQwtDgvXaHHDwAAyb6gTC!QEOVdoOwcHd2S7DJYA3fmgyTl7Qa/a3d°/a3d 2/2
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4`.
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 2 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR FIN INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
TABLE OF CONTENTS
DESCRIPTION
1 NOTES
2 — 3 ELEVATIONS
REVSMNS
REV DM IPIIDN 611E IPPRDVED
B REVISED GLAZING DETAILS 01708/18 R.L
15. FOR FRAME ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 7/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
16. FOR FRAME ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT
LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM
EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
17. FOR FRAME ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR
WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
18. ALL FASTENERS TO BE CORROSION RESISTANT.
19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3.192 PSI.
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER).
D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM
20. UNITS MAY BE INSTALLED WITH OR WITHOUT FLANGE, OUTSIDE THE HVHZ.
SIGNED: 0111812018
evrecr unnrzavwen,m
.oNsua•
I SERIES 176 SH VINYL SINGLE HUNG WINDOW I
IMPACT 54" X 77"
NOTES
swc NTs o1>E 11/17/14 OB SozE52 OF 7 B '77ijD11NAL0N\��`
L. Ro9ERTO LOWS P.E Luis R. Lomas P.E.
T�,az WOODFORDAD LEw15WLLE Mcmozs FL No.: 62514
as4sesasos mmnasOu7wamemN
7
FIR
HEI
6' MAX
L
6" MAX
J_
13"
MAX O.C.
7" T—
WE
GHT
6" MAX
RFASIONS
HEV p6CRIP110x
6" MAX
B REVISED CU21NG DETAILS
SERIES 176 SH VINYL SINGLE HUNG WINDOW
EXTERIOR VIEW
FIN INSTALLATION
DESIGN PRESSURE RATING
IMPACTRA77NO
+70.01-85.OPSF
LARGE
MISSILE IMPACT
MISSILE LEVEL D, WIND ZONE AND HVHZ
54'X 77' UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS
FRAME AREA DOES NOT EXCEED 2&87 FP
NOTES:
1. MAXIMUM SASH SIZE: 50 3/8" X 37 3/4",
2. MAXIMUM D,L.O.: 49 1/8" X 34 3/4`,
3. (2) WEEPS WITH COVER (97-03) AT SILL FACE 2" FROM EACH CORNER.
4. (2) 1 1/2" X 1/4" WEEP SLOT AT SILL FACE 2" FROM EACH CORNER.
5. (2) 1/2" X 1/8" WEEP SLOT AT SILL BEHIND GLAZING LEG.
3/16" ANN.
1"
1/8" ANN.
.090' SENTRY GLAS BY KURARAY
1/8" ANN. 3/16' TEMP —
INTERIOR
EXTERIOR
OURASEAL EXTERIOR
SPACER SYSTEM
BY OUANEX
GLAZING BEAD
STRUCTURAL SEALANT GLAZING BEAD
SIKAFLEX 552
SETTING BLOCK (30096)
1/2" ERE
85 DUROMETER 1/2" BITE
BY CENTRAL RUBBER
1n
EXTRUSIONS .
WE MPROh➢
"OB/18 1 R.L.
1"
1/8" ANN.
.090" SENTRY GLAS BY KURARAY
1/8" ANN.
INTERIOR
DURASEAL
SPACER SYSTEM
BY OUANEX
STRUCTURAL SEALANT
SIKAFLEX 552
SETTING BLOCK (30096)
85 CER
BY CENTRAL
RUBBER
EXTRUSIONS
r� Eastern A "
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
ELEVATION
DMWN: MG NO,
N.G. 08-02538
'� NTS oTE 11/17/14 s"`O`O2 OF 7
SIGNED: Of/18/2018
Luis R. Lomos P.E.
FL No.: 62514
FR
HE
54III* FRAME WIDTH
6" MAX MAX 6' MAX
MAX
6
10
MAX
OO.C.
7
WE
GHT
4�
6' MAX
_ 7
FR
HE
I
SERIES 176 SH VINYL SINGLE HUNG WINDOW
EXTERIOR NEW
THROUGH FRAME INSTALLATION
FORMASONRYAND METAL STRUCTURE
54' FRAME WIDTH
6" MAX 12" MAX O.C. 6" MAX
6" MAX
6"
MAX O.C.
7"
WE
GHT
O /
4�
6" MAX
I
SERIES 176 SH VINYL SINGLE HUNG WINDOW
EXTERIOR VIEW
THROUGH FRAME INSTALLATION
FOR WOOD FRAMING
DESIGNPRESSURERATING
IMPACTRARNG
+70.01-85.OPSF
LARGE
MISSILE IMPACT
MISSILE LEVEL D. WIND ZONE AND HVHZ
51'XI UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS
FRAME AREA DOES NOT EXCEED 28.87 FT -
REVISIONS
REV
FRIMN
DATE
I -PR—O
D
REVISED GU NG DETAILS
01/08/18
R.L
1� Eastern " pe
�im®°rur�m'�i. rivPODi �mn
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
ELEVATIONS
N: OWG NO.
OB-02538
. NTS 11/17/14 JsNfl3 OF 7
LROBERMLOWSP.E
1492 DFDRDRDLEWISVXLE, NC2N20
49168Rd dbmos®IROm ,Dom
SIGNED: 01/182018
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1/2" MIN.
EDGE DISTANCE
l l/4" MIN.
EMBEDMENT .
BACKER R00
& APPROVED
SEALANT
uo LJ�Q
0
n
L�
1/4" MAX.
SHIM SPACE
b10 WOOD SCREW
1 1/4" MIN.
EMBEDMENT
J
MIN.
EDGE
DISTANCE
1/4" MAX.
SHIM SPACE
INTERIOR
000
O
a
EXTERIOR
//10 WOOD
D o
SCREW
WOOD FRAMING
OR 2X BUCK
_
BY OTHERS
On
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
INTERIOR
ILL TO BE SET
A BED OF
PPROVED SEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
REVISIONS
REV OES m"ON WE MPRMD
B REVISED GLAZING DETAILS 0,/OS/,B R.L.
BACKER ROD EXTERIOR
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR2X BUCKWTALLARON
NOTES:
1. INTERIORAND EXTERIOR FNISHES, BYOTHERS,
NOTSHOWNFOR CLARITY.
P. PERIMETERANDJOINTSEALANTBYOTHERSTOSE
DESIGNED IN ACCORDANCE WITH ASTM E2112
SIGNED: 01/1&(2018
a' Eastern.
SERIES M176"SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
INSTALLATION DETAILS
DRPWN: ow0 NO.
N.G. OB-0253B
SW NTS JpTE 11/17/14 1SN 4 OF 7
LR SCRTOLDMASPE I Luis R. Lomas P.E.
U WDDOFORD RD LEWISVILLE NC270T.1 FL ND.: 62514
13(dB8O609 illorr1az®Irbmeye.mm
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
METE
STRUCTUF
BY OTHEF
VERTICAL CROSS SECTION
METAL STRUCTUREINSTAU A77ON
3/4" MIN
DGE DISTANCE
1/4" MAX.
SHIM SPACE
:MS OR
DRILLING
v
INTERIOR
TO BE SET
BED OF
ROVED SEALANT
1/4" MAX.
SHIM SPACE
3/4"
MIN.
EDGE
DISTANCE
I
#10 SMS OR �
SELF DRILLING
SCREWS
METAL
STRUCTURE
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
RENSION$
REV DESCRIPTION DUE I EPRO
B 1 REVISED GWING DETAILS 01/08/18 I R.L.
/4" MAX.
FSHIM SPACE
1 INTERIOR
EXTERIOR
JAMB INSTALLATION DETAIL
METAL STRUCTUREINSTALLARON
NOTES:
I.INTERIORAND EXTERIOR FlNISHES, BYOTTIERS,
NOTSHOWNFORCL4RITY.
2. PERIMETERAND JO/NTSEALAAT BYOTHERS TORE
DESIGNED W ACCORDANCE WITH ASTM E2112
earssiwE...nr...
SERIES 176 SH VINYL SINGLE HUNG WINDOW
IMPACT 54" X 77"
INSTALLATION DETAILS
DR .N: UYX NO.
N.G. 08-02538
:calc HIS o"� 11/17/14 s"oo`5 OF 7
L ROSERTO LOMAS PE
14 WOODPORD RDLEWISVILLE, NG20
dSO.RBRO602 Nl�..
SIGNED. 01/1&2018
Luis R. Lomas P.E.
FL No.: 62514
OPTIONAL 1X BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
I OPTIONAL 1X BUCK
SEE NOTE 3 — 7
SHEET 1
CONCRETE/MASONRY
2" MIN. BY OTHERS
EDGE DISTANCE
a
• ° a • 1 1/4" MIN. 1 1/4" MIN.
°e° EMBEDMENT EMBEDMENT
• a'
}' CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK ae°
D u SEE NOTES 3 — 7
O 1MAX. SHEET 1
SHIM M SPACE
rT1� 3/16" TAPCON
3/16" TAPCON
• v .
INTERIOR
2"
MIN.
EDGE c
DISTANCE
RNMONS
RU DESLRIPOON GATE APPRWED
B REVISED GLAZING DETAILS 01/OB/18 R.L.
1/4" MAX.
SHIM SPACE
INTERIOR
D)=C
Y EXTERIOR
JAMB INSTALLATION DETAIL
CONCRETEMASONRY INSTALLATION
L RE SET
L
NOTES: '
NINTER/OR
B
BED OF
1. AND EXTERIOR FM/SNES, BYOTHEgS,
SEALANT
NOTSHOWNFOR CLARITY.
2.PERIMETERANOJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE W/THASTME2112
kAPIPROVED
1/4" MA%.SHIM
SPACESIGNED:O1/18/2018
law- Eastern A a
cwEra �+nw ar•nr
S it. LL T
`�J�S R. LpWiii
M176"SH
•
°•
SERIES VINYL SINGLE HUNG WINDOW
S*• 0 6 '+t?
e, °
IMPACT 54" % 77"
- (�(tclla/+�xs+'
°. e
•
INSTALLATION DETAILS
�p TAT E OF ; Qy
i0 .
�i�'�A
oRAwN: Rwc NO. REv
N.G.08-0E2E538 B
.'�ORIV% �
��iAsE�/......tN
CONCRETE/MASONRY
DArE
NTS 11/17/14 6 OF 7
VERTICAL CROSS SECTION BY OTHERS
LROBERTOLOMASP.E.
Luis R. Lomas P.E.
CONCRETE41ASONRYINSTALLATION
Ian WDODFORDRDLEWISVILLENC2T023
FL No.: 62514
a3 e-c6c9 mamas®4loniesPRsan
APPROVED
SEALANT
BEHIND FIN
#10 WOOD
SCREW
1/2' Al
EDGE DISTP
NOOD
"RAMING
3Y OTHERS
1/4" MAX.
SHIM SPACE
WOOD FRAMING —.{ 1/4 MAX
BY OTHERS SHIM SPACE
INTERIOR
1 1/4'
o
MIN.
EMBEDMENT
00 O®
T--
Do
INTERIOR
EXTERIOR
#10 WOOD
SCREW
APPROVED
MIN
EXTERIOR
SEALANT
EDGE DISTANCE
BEHIND FIN
III
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
1/2' MIN
J
EDGE DISTANCE
#10 WOOD
SCREW
APPROVED
1/4' N
EMBEOME
SEALANT
BEHIND FIN
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
1/4^ MAX
SHIM SPACE
WOOD
FRAMING
BY OTHERS
NOTES:
I.INTERIORANDEXTERIORFWISHES,BYOTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETERANDJO/NTSEALANTBYOTHERSTOBE
DESIGNED IN ACCORDANCE WITH ASTM E2112
RMSIONS
DESCRPRON I DUC I •PMNVE➢
REVISED GLAZING DETAILS 01/08/18 JR.L.
SIGNED: 01/18/2018
SERIES 176 SH VINYL SINGLE HUNG WINDOW*•
D..8�261 +�
IMPACT 54" X DETAILS
INSTALLATION DETAILS
9 rf(L',(cT
TATEE
iIA'
OF � yytL�,L
PO••
�i4•�S.A[ORIOP
N:
M No.
reLv
OB-0 538
B
�ONA 11�a\X�.
Luis R. Lomas P.E.
FL NO.: 62514
04TE
NTS 11/17/14 s7 OF 7
L ROBERTO LOMAS P.E
1432 WOODFORD RD LEWISVILLE, W=23
xomas@
G909330609 Pbmasp
Flqrida Building Code Online
Page 1 of 5
BUS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Scats & Facts i Publications I contact Us I KIS Site Map ! unxs Search
dbd r
Product Approval COPY
svu3�r a USER: Public User C O PY
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL20470-R2
Application Type Revision
Code Version 2017 REVIEWED FOR
Application Status Approved CODE COMPLIANCE
Comments ST. LUDIE COUNTY
Archived ❑ B®,''kk��9' C
Product Manufacturer Therma-Tru Corporation 66dd
Address/Phone/Small 118 Industrial Drive
Edgerton, OH 43517
(419)298-1740
rickw@mbidgconsultants.com
Authorized Signature Vivian Wright
rickw@ rwb Idgconsu Rants. com
Technical Representative
Address/Phone/Email
SCANNED
Quality Assurance Representative BY
Address/Phone/Email St. Lucie
County
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Lyndon F. Schmidt, P.E.
PE-43409
National Accreditation and Management Institute
12/31/2021
Ryan J. King, P.E.
9 Validation Checklist - Hardcopy Received
FL20470 R2 COI (a) Certificate of Indeoendence.odf
PikT
ASTM D1929
1996
ASTM D2843
1999
ASTM D635
2003
ASTM D638
1996
ASTM E1300
2004
ASTM E84
2000
ASTM G26
1995
ASTM G7
1997
TAS 201, 202, 203
1994
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9D/o2f... 6/28/2019
Florida Building Code Online
Page 2 of 5
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Florida Licensed Professional Engineer or Architect
FL20470 R2 Equiy Equivalency of Standards.odf
Method 1 Option D
04/10/2019
04/17/2019
04/25/2019
06/18/2019
Go to Page
it ''!y Pagel/ 24 0
FL If
Model, Number or Name
Description
20470.1
a. Therma-Tru Fiber -Classic and
Nominal 68 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL20470 R2 II (b) Tnst 20470.1.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.1 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470.1.odf
additional use limitations, Installation instructions and
FL20470 R2 AE (b) TT PlaSUCs.2.odf
product particulars.
Created by Independent Third Party: Yes
20470.2
b. Therma-Tru Fiber -Classic and
Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470.2.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.2 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics.2.odf
additional use limitations, Installation instructions and
FL20470 R2 AE (c) Eval 20470.2.odf
product particulars.
Created by Independent Third Party: Yes
20470.3
c. Therma-Tru Fiber -Classic and
Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL20470 R2 II (b1 Inst 20470.3.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.3 for Design Pressure Ratings, any
FL20470 R2 AE (b1 TT Plastics.2 odf
additional use limitations, installation Instructions and
FL20470 R2 AE (c) Eval 20470.3.odf
product particulars.
Created by Independent Third Party: Yes
20470.4
d. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL20470 R2 II (c) Inst 20470.4.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.4 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics.2 odf
additional use limitations, Installation instructions and
FL20470 R2 AE (c) Eval 20470.4.odf
product particulars.
Created by Independent Third Party: Yes
20470.5
e. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sidellte(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL20470 R2 TT (c) Inst 20470.5.0df
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEV XQwtDgsJ9a49YAgXJuu9%2f... 6/28/2019
Florida Building Code Online
Page 3 of 5
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.5 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics 2 odf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 5 odf
product particulars.
Created by Independent Third Party: Yes
20470.6
f. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approvedforuse in HVHZ: Yes
FL20470 R2 H (c) Inst 20470.E odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.6 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plast cs 2 odf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 6 odf
product particulars.
Created by Independent Third Party: Yes
20470.7
g. Therma-Tru Fiber -Classic and
Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470 7 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.7 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics 2 pdf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 7 odf
product particulars.
Created by Independent Third Party: Yes
20470.8
h. Therma-Tru Fiber -Classic and
Nominal 6'8 "Impact' Glazed Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL20470 R2 II (b) Inst 20470 8 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Intlependent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.8 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics 2 p_df
Ilion imitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 8 odf
pro articula
Created by Intlependent Third Party: Yes
0470.9
Fiber -Classic and
Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass
LI.Therma-Tru
ooth-Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limi f Use
Installation Instructions
wApproved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470.9 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.9 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics 2 odf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 9 odf
product particulars.
Created by Independent Third Party: Yes
20470.10
j. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (c) Inst 20470 10 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.10 for Design Pressure Ratings, any
FL20470 R2 AE (b) Tr Plastics.2 odf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 10 odf
product particulars.
Created by Independent Third Party: Yes
20470.11
k. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL20470 R2 II (c) Inst 20470 11 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.11 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics 2 odf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470.11 odf
product particulars.
Created by Independent Third Party: Yes
20470.12
I. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2f... 6/28/2019
Florida Building Code Online
Page 4 of 5
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (c) Inst 20470.12.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.12 for Design Pressure Ratings, any
FL20470 R2 AE (b) TT Plastics.2.Ddf
additional use limitations, installation instructions and
FL20470 R2 AE (c) Eval 20470 12 odf
product particulars.
Created by Independent Third Party: Yes
20470.13
m. Therma-Tru Fiber -Classic and
Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with "Non -Impact" Sidelite(s)
(Inswing/Outswing; XO, OX or OXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470.13 pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.13 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470.13.odf
additional use limitations, installation Instructions and
FL20470 R2 AE (b) TT Plastics.2.1)df
product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
Sidelites, this product approval requires the use of "I" part
numbers for these Sidelites, which have been stained or
painted within six months of Installation.)
20470.14
n. Therma-Tru Fiber -Classic and
Nominal 68 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with "Non -Impact" Sidelites (Inswing/Outswing;
OXXO configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470 14.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.14 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470 14.Ddf
additional use limitations, installation instructions and
FL20470 R2 AE (b) TT Piastics.2.Ddf
product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
Sidelites, this product approval requires the use of "J" part
numbers for these Sidelites, which have been stained or
painted within six months of installation.)
20470.15
o. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with "Non -Impact" Sidelite(s)
(Inswing/Outswing; XO, OX or OXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470.15.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.15 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470.15.Ddf
additional use limitations, Installation instructions and
FL20470 R2 AE (b) Tr Plastics.2.odf
product particulars. (For Fiber -Classic and Smooth -Star
Created by Intlependent Third Party: Yes
Sidelites, this product approval requires the use of'7" part
numbers for these Sidelites, which have been stained or
painted within six months of installation.)
20470.16
P. Therma-Tru Fiber -Classic and
Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with "Non -Impact" Sidelites (Inswing/Outswing;
OXXO configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470.16.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.16 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470 16 odf
additional use limitations, installation instructions and
FL20470 R2 AE (b) IT Plastics.2.odf
.product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
Sidelites, this product approval requires the use of'7" part
numbers for these Sidelites, which have been stained or
painted within six months of installation.)
20470.17
q. Therma-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Composite Edge
Smooth -Star
Fiberglass Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470.17.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Intlependent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.17 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470.17.Ddf
additional use limitations, Installation Instructions and
FL20470 R2 AE (b) TT Plastics.2.odf
product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu96/o2f... 6/28/2019
Florida Building Code Online
Page 5 of 5
Sidelltes, this product approval requires the use of "J" part
numbers for these Sidelites, which have been stained or
painted within six months of installation.)
20470.18
r. Therryl Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Composite Edge
Smooth -Star
Fiberglass Single Door with Sldelite(s) (Inswing/Outswing;
XO, OX or OXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470 18 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.18 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470 18 odf
additional use limitations, Installation Instructions and
FL20470 R2 AE (b) TT Plastics 2 odf
product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
Sidelites, this product approval requires the use of "J" part
numbers for these Sidelites, which have been stained or
painted within six months of installation.)
20470.19
S. Therma-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Composite Edge
Smooth -Star
Fiberglass Double Door with or without Sidelites
(Inswing/Outswing; XX or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470 19 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.19 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470 19 odf
additional use limitations, installation instructions and
FL20470 R2 AE (b) Ti Plastics 2 1nddf
product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
Sidelites, this product approval requires the use of "I" part
numbers for these Sidelites, which have been stained or
painted within six months of Installation.)
20470.20
t. Therma-Tru Fiber -Classic and
Nominal 8'0 "Non -Impact" Opaque Composite Edge
Smooth -Star
Fiberglass Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL20470 R2 II (b) Inst 20470 20 odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20470.20 for Design Pressure Ratings, any
FL20470 R2 AE (b) Eval 20470 20 odf
additional use limitations, Installation Instructions and
FL20470 R2 AE (b) TT Plastics 2 odf
product particulars. (For Fiber -Classic and Smooth -Star
Created by Independent Third Party: Yes
Sidelites, this product approval requires the use of'7" part
numbers for these Sidelites, which have been stained or
painted within six months of installation.)
Go to Page = 40
Back Next
00 Page 1/21* 0
Contact Us:: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2997-2913 State of Floritla :: Privacy Statement:: Accessibility Statement ::Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida statutes, effeRive October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please pmvide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click hem.
Product Approval Accepts:
Mal 9 M
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2f... 6/28/2019
THERMAITRU®
DOORS
Fiber -Classic. & Smooth -Star.
COMPOSITE EDGE
GLAZED FIBERGLASS DOUBLE DOOR
w/ or w/out SIDELITES
INSWING/OUTSWING
GE14ERALNOTES
T. This product evaluation drawing has been developed In comp6cr with the 6th motion 12DI71 flado Balding
Code (FBC) including the'lBgh Velocity Hurricane Zone° (HVHZ).
2. Product anchors shoo be as feted and Weed as shown an details. Anchor embedment to base material W be
beyond well dressing orstucco.
3. When used in the'HVHP this product compiles With Section 1626 of the FBC and does not require on impact
resMantcovering.
4. When used in areas outside ofthe 9lVHrmWFing wind bane debris profedion, this product compir with FBC
Section 1609.12 & R301.21.2 end does not require an Impact resistant covering. This product meets missile level
'D°and Indudes Win Zone 4 as der. ad in ASTM E 1996 and FBC Sections 1609.11.28 R3011.12.1.
S. For 2xstud hurling construction, anchoring of these units shall be the same as that shown forts buck masonry
construction.
6. Site condition thatdeviute from the details of INS drawing requirefirdhe.rengineaing analysis by a licensed
engineer a reghtered arohilecl.
7. Ihh product meets the water Infiltration requirements taase'HVHr.
8. Oulswi o configuation using Caastd Si (Rem #19) A Composite SIT (dem 016) undaactive dean meet water
hilthation requirementsfar N/IP. At olherconfiguraFan do not meetlhewoternfdfrationrequiremerds lathe
91VHP and shall be instated onlyn non -habitable areas prat habitable IocoBons protected by an overhang or
canopy such that the angle between the edge of canopy a overhang to s01s less than 45 degrees.
TABLE OF CONTENTS
sNFF71
DESCRIPTION
I SHEET#
1
Typical NevaDesign Presams S General Notes
8
1Vmlrc Croy SecHan nilvesholdt
2
Daar Panel Detolls
9
flue M
3
Sdnel elte PaValais
TD
Fsome Anehang
4
Elevatba
II
Hadwve Details
1
5
Horaonlot S Venccol Cons Sections aBUc
12
Gaft Details
6
Hoftontal K Venice] Cons Sechaa I
13
Components
7
a B enccal Cross Se D fto Mdwnr,
14
9iol Materiels
�7475'WIL CA FRAME WIDTH
00
o�
^ O
^
;J!5Z7S
MA% FAFRAMETH37S. 74.75MAIL FRAME WIDTHFRAMTH
{
{
d9
0o
= Hon
m�
O
X e
O
X
O
Lj
DESIGN PRESSURE (PSI)
DESIGNPRESSURE(PSF)
CONFIGURARON
LOCK
INSWING
OIDSWING
HARDWARE
POSITIVE
NEGATIVE
POSITIVE
NEGATIVE
xx. oxxo
Latch a Deadbolf
+50.0
-50.0
+50.0
-50.0
fox. oxxo
Multipoird
+55.0
-55.0
+55.0
-55.0
See Sheet 4 for Hardware Specifications
$<g'a = n
za*/4YrOFd
a
FL-20470.9
I
T 88 X 2.5- PFH WS IIYP. @ EACH DOOR CORNER)
HOP RAIL
' (COMPOSITE/ ..�
30- MAX. DOOR 35.813'MAK DOOR 35.8lrMAX.DOOR ENGINEEREDWOOD)
PANEL WIDTH PANEL WIDTH F PANEL WIDTH
INTERIOR
N
1
X o X m1 o X°
� 8 �
DOOR PANEL DOOR PANEL @A001PAN11
40 800K 4, NAMd Door Ul Doan
FOAM CORE
)POLYURETHANE- .*
1.9 PCF MIN.)
%11EKTERIOR INT3ROR
FlBE2GlASS SqN o`06102116
scar: N.T.S.
I-171'�-I lw^^I'•) 1-171'--i ;Wert LFS
VERTICALCROSSSECTION (VERTICAL CROSS SECTION CROSS SECTION wFL 2-0 a
2 2 FL-9 ;;7, 9 a
cxm � K 16 �
we �: JK c
R:10entAnTh Tu PBtNANFNRA-lmxa PmEuRAppmve R-3H70KOR-OmMste(C-ORwhn XFt-303A(R017)1R-10110.13.dy3.3
�7975 MA%. PANEL HEIGHT -{
a I
0
w
O 0 0 n n n n 0 n n=
,pa z O A 33
z O O g
Oj A
g> O f3 A
O a
G
N
m
n
Ait
m O Z g
�o as
N
y�
0 n.
0
-8a
8o o
wN OOA ]S Zm pgEO
A
n �
A 1:
Q I+y
�g A
va
V ����11f,SCHM.�IiII
V,...ue..xec+.,.T
/may INC.
7zy17
qp PRODUCT: 9ocumem. PnPm.x W. BGTBOP
1 �" o THERMS -MU C N. r q mt------- ` ••
I61 a Z mo FlBERCLL55 DOOR IIIIs�'O1NALt`;`s��
R V 4 N PART OR AS6EMBLY: 6UILDINO CONfiULTANIB. L6N.
1 ] 1I 1] UPO4TE 10 6M m. 201] feC JK SIDELITE PANEL DETAILS �V�/ P.O. Box MO. Voleco, R M595
N` sO N NO DATE BY Ph-ne No.: 813.659.9197
REVI50 S FBPE CA No. 9R13
O SDIB R.W. BuiLu1MY Cuxeuti.,ne :xe.
&-WntNna Tm PEQIMNEN - F P d Ay vahWL-M470 N T7 - f mpm XlC - OraWWFXFL-2M (417)VL-2HM.7AdX, Ij
2m
cmw
0
z
0
R
-n
S
Pimp
® m W
00
0
0
o
z o'l
r.::
11 A
1111,111C
F,S
NO.43409
7 2-
PRODUM
OF
o
MERMA-TRU
nBERGLASS OGOR
Bi-Idt
P.E. NO. 434a9
—f
PANT OR ASSEMBLY:
BUIMING CONSULTANTS,
7 14 17
UPNM m ON ED. 017 MC
JK
ELEVA77ONS ]RU(P-0-
BOX 2W, V01"co. 33595
NO.
DATE
BY
813.659.9197
MPE CA No. 9813
REV IRIMq—
—
O
�1 HORIZONTAL CROSS SECTION
5 o tsving sh wn(Inswing shNarl
5)HORRONTALCROSSSECHON
5 O..%shown ll g ar)
DR
OR
/'21 HORIZONTAL CROSS SECTION
5 Stwvmw/MUUM
oulswing shown (hwmg molar)
�61 HORRONTAL CROSS SECTION
5 Ou ngsnown prawing similar)
Notes:
�p� i •...•
;'GO':
I.Sidefitea mbly=miocated6'fmmeachendondSmoresaewa
C:'
'••y
n
equalyspaced between[7u totalpersldojornb).
2. Sidefde assembly spews located 3'from each end a at centerfine
—
(3 screva along headjamb).
=0
_ y?;
#
Q—. a
�) 2Y n
z
...
E .. - ..
d'm
v
a
ay_Z
v •
V P
$ i w
�
e ma:fe
L
a
3a
b
C
Y
F
Fm
�
41 42
Ho
6 T
7s
gU
EXTERIOR INTERIOR
u
�1 VERTICAL CROSS SECTION
d
5 Oul
ng sham(Ins*g simko
D
v
n
rc
L
?a
c
wF
1
_�s
25
n
¢o
SEE NOTE
-o
y
Z n
50
z
oaa OS 02116
x
scee N.T.S.
EXTERIOR INTERIOR c
JK m
aa. er.
LFS
CROSS SECTIONCROSS SECTION
"'"'°'0 N6
4VERTICAL
5 Shownw/2
Fl.-20470.9
m
°e
(I
OulsNng shown Omwlne molar)
msxr s
-J4 U
Notes:
`�O�C .%........,
H/���
I. Sidelite assembly saaws located 6° from each and and 5 more screws
Q.'
'•.�' n
equaly spaced between(] screws total per ddeJamb].
fmm
2. Slde6te assemb"ciews located T each end &at centerline._�'�
(3screwsolongheadjamb(.
ICI d
.`y
?0�
., .. y;
��•.,•
,.q
////III
n
111\
\l\\\\\`, i a
A�
o 6
0Roz
A
C
Aas
90�;
E
C
E
40 41 42
� o?
C
O
P.
6 1
•�
J
EXTERIOR INTERIOR
8
��,Ym
k
6 50
3
'
VERTICAL CROSS SECTION
G L INTERIOR
6 Snamm w/lX seb-buck
50%( lnsM(g
gSIhx.-m similar)
m
Y Ny
�
K�a
a
•�
of
K
•
J
6
V
6
7m
)
a.
'
23 24 DMIOR 25 E • . ..
SEE NOTE
I-1/4°MIN. 29 40 41 42
1 p
n
EMB. (TYP.I
m
MIN.
13
w
(IYP.)
A
i—
C
I' I \ liOR120MAL CROSS SECTION %1NORROMAL
CROSS SECTION
m
a=
6 SnaVmw/Ixsub-buck 6
snownw/Ixsubbuc
25
T�
Oulsvingshown(Inswirgshfar)
Outswing shown (Inswing s Wcq
SEE NOTE
3
C
50
1
4
Yr
^Q
i
EXTERIOR INTERIOR
g
oar: 08 02 16 °
�1 VERTICAL CROSS SECTION
...,.. N.T.S.
6 5nownw/1XsuGbuck
oum. er: JK m
OUISMw shown(Inswing sumlar)
oo°en LFS 3
vuvw ao:
m
FL-20470.g u
a¢sr 6 as 14 0
s I -IS
2y
E IX
��• E '�' r MW� E � MIN : V•.
'A•6/II ul
E% `102 INfEmOR
3 VERTICAL CROSS SECTION
7 Shown D'oecf to MasoruT
OUIR oNy w/49/16jamb
Douhle DaorONy jN/Aw/SideFfas)
Notes:
1.SIdeG1e assemby somm located 6' from each end plus 5 mare
equally spaced between p screws total persldejambj.
2.SIderde assembly screw: located r from each and & at centelfoe
t3 screws abrg head jamb).
�g n Q
INTERIOR
1-1/4'MW.
EMR. g9R.l
DMIOR
I HORIZONTAL CROSS SECTION
7 Shown D'uect to Mosom
Ouhwtng onlyw/4-9/16 jamb
Double Door Only )NIA w/ Sidelites)
E%IERIOR INTERIOR
%S"\ VERTICAL CROSS SECTION
7 Sncwnumcrto Mosonrt
Oufswing oNyw/ 0/16 jamb
4 HORIZONTAL CROSS SECTION
7 OuWngonywa9/16 jamb
EXTERIOR INT960R
r�61 VERTICAL CROSS SECTION
7 Soh �Die�f� jamb
4��
INTERIOR
ILW
�V•� n
em
n
OAm2
UN•:
o 0,E zm a
6
4� Za:fLj
P2114�1109
a
p
. No�Item AS 17,18,32,34,35,36,37.38d39ore attached to pmbsw/(3)k8X2-1/Tpfh=e at each end. Q'.• 0�
SBhem RS168,33areattachedto)otnbsw/(2)88X2-1/Tp8sso afe chend.
Sill Item715Ts attached to)ambs utaing(2) 810XTpphSNS ateach end.
2. Sidefte assemblyscrexs localedTfrom each end aatcenterfine(3saemdongsill).
7 tl1; C
�(" 6;
..... ' `�� § s n n
INTERIOR EXTERIOR INTERIOR EXTERIOR i��'7jT7 0� H>�m
z dr;
40 41 42 40 41 42 o 7w
g EXTERIOR INTERIOR a y4 9 d a
16 171819 847 maaE
38 39 32 33 34 S5 36 37 40 41 42 7 z
SEE NOTE vW (�
SEE NOTE 1 E E 3d " a
SEE NOTE 1 E
0
M
• I •.. . z v �m FG
0
T VERTICAL CROSS SECTION `� VERTICAL CROSS SECTION 3�VERIICAL CROSS SECTION \ � a a
g Irlswv19 SR g Iruwin95a 8 OuhvAng S6
y}
� aI
INTERIOR EXTERIOR
EXTERIOR INTERIOR SEENOTE2 25 50 EXTERIOR INTERIOR
m
40 41 42 77 75 32 33 34 35 36 37 38 39 SEE NOTE 25 50
16 17 18 d z
10 o rc
15 E E 76 E d
SEE NOTE I
^w S
21
0 sesa: N.T.S. _
_ ic' \ W. JK m
F
er. LFS ?
��VERIICAL CROSS SECTION VERTICAL CROSS SECTION �61 VERTICAL CROSS SECTION
g PubSc Access SB = g Nrv6n9 S�➢ 8 OuhwlnB Sa ft-20470.9 n
sear 8 W 14 O
3C� 6 ams
0
a 6'OL40Z—ii
a ve awvw
i Sd7 w n
rr '"° 9NIHOHJNV )iJ118 XZ
6 'S'TN a
0 9l ZO SO sw
o z
m a oxxo Aallosvw xx
V
� C
T
a, � II II II
I
o � II II II II
y 9 II II II II
0_ II II II II
�w II II II 0— II
II II II '' II
m� II II II II
9 II II II II
II II II
a � II II pdw II haw
m II II sawvr-a avaH II II NAD
�a I II Q II II sswvrvavdH
Nil
A $� 9 II II II 3y II
a �L II II -L II
l7i t; ('dw� WA0.e (dw9
fdwa hdw� faAU.e •.
e� 3 s 1'dw s ram, r I'dw.v
Woymsy
UPI ,�
}zoyo� u
o m o i
w a bp
•T i
•'Oi�a0•'A
u CCAv
u $;,
"/nnnn,n
DIRECT iO u
MASONRY P
AS RAGAL
HEAD
(TYP.) 3' (TYP.)
II\
SEEDETAILI
II (SHEET II)
FRAME
VRUCK
I
(TYP.)
J 1XBUCKI
HEAD &JAMBS
I
ITYP.)
II
DIRECTTO M
II
MASONRY
JAMBS
I
IttP.I
I I
- D SILL
(Typ)
II
I SEE DETAIL:
1 (SHEET 11I
— I I
I II
xX
1 n6°(TYP.I
Bul
(1Y
DIRECT TO
MASONRY
d
6d
DIRECTTO D
MASONRY
HEAD ASTRAGAL
DyP•I
`lwi8x2-JjT
PFlI WS
JAMB TO HEAD DETAIL
(n•P.)
IMULUON
4'(TYP.)
8 nP.I
I I
11I ISEE DETAILI
I(SHEEPIIJ11
V
- -
.K
HEAD b JAMBS I
hYP.J II
—
N
II
II
D
SILL�) (TYp.I 11 SEE DUAIL2
(SHEET II)
II
L
MASONRY OXXO
"P.l
FRAME ANCHORING
* 0 Q
S
o
� W
�
o
a
Tm
�
EE
e JK m
L e LFS
77. rva
FL-20470.9 =°
0
n 70 Rr� u
0.,1,1,111IE//
..�
� s'� � B"•mac B
�� ,GE•, C,:O��n
NO � O
SEE HINGE i %'•• .i�aC u'm,a
DETAIL W.)
O2730YE I III LX c z dm d
ga@ Em z m c a
LATCH&DEADSOLTDETAIL LATCH& DEADSOLT DETAIL Vr d7"sf 961
Schloge/KwUml p o q 'Polo
BBL,SotL
°�
(2XX
RECITO b rym M DIRECTTOASONRYRg �+� "1 MASONRY
BUCK G IX BUCK
BUCK 80 BFEIATCN 25 7X BUCK 78 0
SEEWCX &OFADBOLT g o
DEWL }j�
& DETAIL
IT n oBo guT 3
� 3
� o
DETAIL I o
Coastal Astragal Strike Plate ® Head DETAIL I
MulBpoinf Lock Strike Rate ®Need ?
ASTRAGAL HINGEJAMB ASTRAGAL
Latch and Deadbolt Mdlipolnt Lock
n
n �
JGD�F�rAJL2
o
29 L 2X BUCK F i80 DETAIL2 G a:(�• 1X BUCK 79 ra-CowidAshag Str8'ePlateGS& M DIRECTTO ra
MASONRY MulU oinl LockSWe PlatedSLl
y
lirOHOIE 24 — _
23
a
L
HINGEDETAIL np 16
DL2 G DETAIL2 S
80 DETAIL G why —mg
°
=Br. JK m°
Outwv Multipolnl Lock5tnle Pkde0
htw�re AshogalB011Hde®SA f-1�2��4:70!9
F LFc
CoanwmtragalshamPwre@sm MULTIPOINTLOCK STRIKE DETAILS LATCH&DEADBOLTSTRIKEDETAILS nwou
1 w�
0 ...... ..
EXTERIOR
z s
CELLULAR
GLARING TAPE 1/21GLASSBFTE
I"THK.GLASS 01%
y,
IfirTE.MPERED GLASS VE
I/TAIRSPACE qF, d
.:z
513T ANNEALED GLASSyg�- j
DOW 995 INTERNAL GRID (GBGI WROUGHT IRON INSERT
#10 X I -Irr PPH S M S
OD9(rPVBRMLAYER
OR (SAFM OR KURARAY BUrAC[M
SIKA552 of
118'ANNE4UED GLASS
3A SVAGGLEGLAZiNGSPACER
MEMOR
Gl=AVN0 DETAIL
GI A�
� hp� Ut. fir�
D=Pamb&SideMo
PRIVACY INSERT DECO TIVEINSE RT
20.Br DLO. b
—I 1"LAMINATED INSULATED IMPACT GLASS INSERT OPTIONS
WIDTH R
1,7 PPH S SWIG GL.ZN
DECO TIVE IN lEl
Im 3�
#lDX 1-1/2PPH SMS d
fryp.l
9-MMM.—NuM FRAME
I
=Pc=me
cdleLrffte d•'F:08102116
N.T.S. 0
ALUMINUM LITE FRAME owe en UK
0..
J —2 a- 4
7.5r
� Rot
L_ '+-� R ,
INSWING INRESHOID
32 InwAn9 Bask ComposHe AtlNslableSR 7-IR'
—I56 -j
ra
INSWING THMOSID
� te».g Bask rued Sm
U� 5JS
R a
�1MSWMG7NRESN010
•ri Imweg Moderate Climatesa"ir
�575�n
INSWING 7NRESNOLD
Inswtn9 Motlerate COmate 5m
�SJS�
INSWING MRESNOLD
36 Wwing Bask Ftred 53/4•Sm
INSWING47FU OLD
37 InrvAn9G Fhetl7-,%rtm
38 MfWING IXRESHOID
Im'^+p9 Composite Adut.tIo 93
5.7T
/11NM7N0 THRESHOLD
u� ImwtaR Base CompaSlte Adpatable Sm
o
1 I
15 PUBUC ACCESS iNRESHOID
L N'.•7 .. ..
I AAEE4n U
F--236'---�
1 WOOD JAMB \`
o OUISWING,HRESNOID
carapasle sm
0
456'
L -1
ff
,J9 -I I--I.9z � -4 T
o
9 SWFFP 9 SWEEP 10 SWEEP c
OUISW/NG,HRESHON
1i Composto ''Whim Sm
i.1 ONSWING MRESNOID
�l i omt�MmYnum SN
4W
236"
L
COASTAL UIS OWING THRESHOLD
19 ty�tl/aluminum SID
�1.91• I
FLUSH BOLT
N
FLUSH BOLT Cl
RESH N9
--4--0.12C
20 COASTAL ALUMINUM ASTRAGAL
2,T�
75 51 SPACER � ib SIOD� SSPACFR n SIOELIIESPACFR
M to CLmte H...tww
8H m
ayS Ndt
a ~ maa
FL-20470.9
BILL OF MATERIALS
BILL OF MATERIALS
11EMIF
DESCRIPTION
MATERIAL
17EM#
DESCRIPTION
MATERAL
A
I BUCK (SG >= 0.42)
WOOD
25
#8x2-1/T'PFH WOOD SCREW
STEEL
B
2X BUCK (SG >= 0.42)
WOOD
26
#Bx5/&"PFH WOOD SCREW
STEEL
C
1/4" MAX.SHIM SPACE
-
27
LATCH STRIKE PLATE
STEEL
D
1/4'X2-3/4" PFH ELCO OR TTW CONCRETE SCREW
STEEL
28
DEADBOLT STRIKE PLATE
STEEL
E
MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90
CONCRETE
29
4"X4"HINGE
STEEL
32
INSWING THRESHOLD
ALUM/COMP
G
3/16"X3-1/4"ITW CONCRETE SCREW
STEEL
33
INSWING THRESHOLD
ALUM/COMP
I
1/4"X 1J/4" PFH ELCO OR RW CONCRETE SCREW
STEEL
34
INSWING THRESHOLD
ALUM/COMP
J
1/4"X3-3/4"PFH ELCO OR ITW CONCRETE SCREW
STEEL
35
INSWING THRESHOLD
ALUM/COMP
L
#lOX2-1/2"PFH WOODSCREW(I.15" MIN. EMBEDMENT)
STEEL
36
INSWING THRESHOLD
ALUM/COMP
M
N
3/16"X2-1/4"I1W CONCRETE SCREW
3/16'X2-3/4" IIW CONCRETE SCREW
STEEL
STEEL
37
38
INSWINGTHRESHOLD
INSWING THRESHOLD
ALUM/COMP
ALUM/COMP
P
1/4"X2-3/4"PFH ELCO CONCRETE SCREW
STEEL
39
INSWING THRESHOLD
ALUM/COMP
1
JAMB (FINGER JOINT PINE)
WOOD
40
DOOR PANEL (BOOK)
6
WEATHERSTRIP (MEDIUM REACH)
FOAM
41
DOOR PANEL (HYBRID)
-
7
WEATHERSTRIP (LONG REACH)
FOAM
42
DOOR PANEL (U1)
8
SWEEP
VINYL
50
SIDELTTE
-
9
SWEEP
(USE W/ MODERATE CLIMATE THRESHOLD)
VINYL
75
SIDELITE SPACER (INSWING)
PVC
10
SWEEP
(USE W/ PUBLIC ACCESS THRESHOLD)
VINYL
76
SIDELIIESPACER (OUTSWING)
PVC
11
#LOX 1-3/4"PFH WOOD SCREW
STEEL
77
SI ant: SPACER(INSWING)- MODERATE CLIMATE SILL
PVC
15
PUBLIC ACCESS THRESHOLD
ALUM
78
MULTIPOINT LOCK STRIKE PLATE @ HEAD
STEEL
16
OUTSWING THRESHOLD
ALUM/COMP
1 79
1 MULTIPOINT LOCK STRIKE PLATE @SILL
STEEL
17
OUTSWING THRESHOLD
ALUM/COMP
1 80
1 ASTRAGAL STRIKE PLATE
STEEL
18
OUTSWING THRESHOLD
ALUM/COMP
88
2X MUWON(SG >=0.55)
WOOD
19
COASTAL OUTSWING THRESHOLD
ALUM/WOOD
CONCREIEANCHOR NOTES:
20
COASTAL ALUMINUM ASTRAGAL
ALUM
23
#lox3/4"PFH WOOD SCREW
STEEL
24
#10x 1"PFH WOOD SCREW
$TEFL
I. Conaefe anchwlacafiom at MB corners maybe aciusfed to maintain the min.
edge distance to mortorjoinb.
2. Conaefe anchorlocatiom noted as 9AAX ON CBQER"must be cdj sfed to
maintain the Mn. edge distance to mortarjoints, additional concrete anchors
may be required to en v e the 'MAX. ON CENTER•dvnerslon are not exceeded.
3. Conaefe anchor fable:
WOOD SCREW INSTALLATION NOTES:
1. Maintain a mWmum 5/8" edge distance, 1' end distance, 8 1•o.c. spacing of
mod smm to prevent the splifling of mod.
orn w.. JK I m
ao:ar: LFS ?
wrmc sa
FL-20470.9 a
°e
sxm 14 or 14 O