HomeMy WebLinkAboutSPECIFICATION SHEETSpecification sheet SCANNED BY St. Lucie Coontl RECEIVED MAY 2 S 2919 ST. Lucie County, Permlttina Quiet Connect`�N= LAN REVIEW Series BLDG: DATE: RS80 ELE DATE: i t PLUMB: FILE C®Py DATE: MECH: Features and benefits DATE' Robust product design and testing - The generator is designed to operate under extreme environmental conditions including cold weather starts at as low as -40 OF when equipped with the necessary accessories. The generator is tested and certified per the latest EPA, UL and IBC Seismic standards and is capable of meeting NFPA110 requirements when equipped with the necessary accessories and properly installed. Flexible exercise mode - The innovative, flexible exercise mode enables the generator to exercise at a time, frequency and duration that suits the customer's preference - as little as 2 minutes every 6 months - reducing unnecessary fuel consumption, emissions and noise. C Power Generation Advanced enclosure design - The aesthetically appealing enclosure incorporates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint provides the best anti -corrosion performance. The generator set enclosure has been evaluated to withstand 180 MPH wind loads in accordance with ASCE7-10. The design has hinged doors to provide easy access for service and maintenance. Self -diagnostics and easy service - The generator is equipped with Cummins PowerCommand® electronic control to provide industry -leading selfdiagnostic capabilities. In addition, critical components of the generator are designed to ensure service and preventive maintenance can be completed in a short period of time. Weight, size and sound level Weight: 2782 lbs. (1262 kg) Size: Length 118.7 in (3016 mm), width 40.0 in (1016 mm), height 58.3 in (1480 mm) Sound: 70.5 dB(A) at 23 ft. (7 m) with sound level 2 enclosure Series Model Phase Voltage(V) Frequency(Hz) Rated amps' (NG/LPVfuel) Circuit hreaker (Amps) RS80 CBON6 1 1201240 60 333/333 125-400 3 120/208 60 278/278 1 125-400 3 120/240 60 241/241 70-250 3 277/480 60 120/120 150 ' Dend ing guidelines: Engine power available up to 1829 m (6000 it.) at ambient temperatures up to 40 'C (104 19. Above these elevations derate at 4 % per 305m (10001L) and 2 % per 10 `C above 40 `C (104 fl. Our energy working for you.- 022016 CumMns Inc. I NAs-6170.4EN (eA6) power.cummins.com It Product features Generator set performance Governor regulation class: ISO 8528 Part 1 Class 33 Engine Voltage regulation, no load to full load: ±1.0% • Natural gas/propane 1800 rpm engine Random voltage variation: ±1.0%, • Engine air cleaner —normal duty Frequency regulation:Isochronous • Electronic governor, isochronous Random frequency variation: ± 0.25%@ 60 Hz • Engine starter, 12 VDC motor Radio frequency emissions compliance: FCC code • Shutdown — low oil pressure • Extension —oil drain Title 47 part 15 Class B • Engine oil — included Fuel system • Single fuel — natural gas or propane vapor, field selectable Alternator • 60. Hz, 1 phase, 4 lead, or 3 phase, 12 lead, 120 °C temperature rise at 40 •C ambient • Exciter/voltage regulator —torque match Control • PowerCommand 1.1 • Display language — English • Control mounting, left facing Electrical • Single circuit breaker, UL certified, right -side mounted • Battery charging alternator, normal duty • Battery charger —6Amp, regulated Cooling • Generator set cooling capability— 50 °C • Shutdown —low coolant level • Engine coolant —50150mixture • Extension —coolant drain Enclosure • Aluminum enclosure Sound Level 1 with muffler installed, sandstone color • Wind rating —180 MPH Code compliance • UL 2200 • EPA emissions, stationary emergency, 40CFR60 • IBC Seismic • NFPA110 capable Generator set application • Coolant heater • Crankcase vent heater • Battery rack • Flexible fuel line • Literature (English) —operator's manual, installation manual Warranty • Base warranty — 2 year standby • Extended warranties available Packaging • Shipping pallet Our energy working for you.^ ®2016 Qlmnins Inc. I NA"170-AEN (6/16) Engine Design: Turbocharged and aftercooled Bore:102.1 mm (4.02 in) Stroke: 119.9 mm (4.72 in) Displacement: 5.9 liters (359 in3) Cylinder block: Cast iron, in -line 6 cylinder Battery capacity: 850 amps at ambient temperature of 0 OF to 32 OF (-18 °C to 0 °C) Battery charging alternator: 52 amps Starting voltage: 12 volt, negative ground Lube oil filter type(s): Spin -on with relief valve Standard cooling system: 500 C (1220 F) ambient cooling system Rated speed:1800 rpm Fuel supply pressure Minimum fuel supply pressure: 1.5 kPa (6.0 in H20) Maximum fuel supply pressure: 3.5 kPa (14.0 in H20) Control system The PowerCommand® electronic control is standard equipment and provides total generator set system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto -shutdown at fault detection and NFPA 110 Level 1 compliance. Sound attenuated enclosure The aesthetically appealing enclosure incorporates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint provides the best anticorrosion performance. The generator set enclosure has been evaluated to withstand 180 MPH wind loads in accordance with ASCE7-10. The design has hinged doors to provide easy access for service and maintenance. pomr.cummins.com Average fuel consumption Fuel consumption —natural gas Load: 1 1/4 1 1/2 314 Full Ft3/hr. 1 455.3 1 678.7 877.0 1083.5 M'/hr: 1 12.9 1 19.2 24.8 30.7 Conversion factor. 8.58f3=1 lb 0.535m3=1 kg 36.39 W = 1 gal Basic dimensions / DAMMURECLUIREn rOOPEVYWORS \ 330 130 126.151 126.75) Im :Q90ai4M!9 CENTER Or CENTER 01 ORAVITT—\ `SERVICE DOOR `SERVICE =3 MGM ME VIEW IwRT►31AU SERVICE PANEL ICL la.0 51R fill Fuel consumption — LP vapor Load: 1/4 112 3/4 Full Fe1hr: 181.9 263 339.8 1 420.8 MD/hr.::1 5.2 7.5 9.6 11.9 Gal/hr 5.00 7.23 9.34 1 11.56 AKE AREAS TOPMEW 1016 [118.11 SERVICE PANEL SERVICE MR 1 145 Q 5. 11 A1R TLar Io3 168 601 119 HI [6.61 I23.91 // 125.31 lix.q FUEL J// 12117MEM W [OnxECTIOV Note: This outline drawing is provided for general reference only and is not intended for use in design or installation. For more information, see Operators and Installation manuals or contact your distributor or dealer for assistance. SERVICE MR --x1 LATCH Our energy working for you: m2016 CAmnim 111c I NASS17PbEN (v16) powef.cummins.com Accessories • HMI211 RS in -home display, including pre -configured 12" harness • HMI211 remote display, including pre -configured 12" harness • HM1220 remote display • Auxiliary output relays (2) • Auxiliary configurable signal inputs (8) and relay outputs (8) • Annunciator—RS485 • Internet monitoring device —PowerCommand 500 • Battery chargers —stand-alone, 12V • Enclosure Sound Level 1 to Sound Level 2 upgrade kit • Enclosure paint touch up kit • Base barrier— elevated generator set • Alternator heater • Maintenance and service kit • Extreme cold weather kit for operating temperatures below 0 OF (-17 eC) 9lendsyrmlrm 6esedon: AppBmbm 9edrmedm emarysydanem terse ror•rpplyingare,gernyPoworrorma etecbxmbn•rNorprepeMdvroew dm&bnotnormplposerlrttemgWn 0o nmwnnatto mry Wimmg xowsrommoretom ep6mryro e1sWWevxytmtoW6mi�Pmvm evallaElemrtNsrming(E@uvabum devimorMerdtlWmy malnbreeke�m roCstoppowerinecm r open 15Oe018, A5rla9,onA2ll O1&o1 ere W ssla) nomwiiY tea sw T W a Contact your North America 1400 73rA Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 more Transfer switch (sold separately) • Automatic Transfer Switches available in various amperages. • Service Entrance models are also available, which helps reduce the installation cost. • All models UL listed to UL 1008 standard. • Available for both Indoor and Outdoor applications. • Compatibility with Cummins generator set helps reduce the installation time for the complete application. Warranty policy The Cummins RS and FIX liquid cooled generator set models come with a 2 year base warranty when used in EPA -Stationary Emergency application. The RA series Automatic Transfer Switches come with a 2 year base warranty. Extended warranty options are available. Please contact Cummins dealers/distributors for details. After sale support Largest distributor/dealer support network Cummins Power Generation generator sets are supported by the largest and best trained worldwide certified distributor/dealer network in the industry. The network of knowledgeable and highly trained dealers will help you select the right generator for your application and advise you on associated accessories for your generator. The dealer network can also help answer any questions you may have regarding operation and maintenances requirements of the generators. This same network offers a complete selection of commonly used generator set maintenance parts, manuals and specification sheets. Manuals: Operation and installation manuals ship with the generator set. To obtain additional copies or other manuals for this model, see your distributor/dealer. To easily locate the nearest certified distributor/dealer for Cummins generators in your area, or for more information, contact us at 1-800-344-0039 or visit oower.cummins.com. NEWMAN'S POWER SYSTEMS 3076 N KINGS HWY FORT PIERCE, FL 34951 772-465-2490 Our energy working for you.- ON16 Cummins Inc All rights reserved Cummins is a registered trademark of Cumrrdns Inc 'Our energy working for you.- is a trademark o1 Cumnuns Power Generation. Other company, product, or service names may be trademarks or service marks of others. Spedfications are subject to change witlmm notice. NA"170iTEN (8116) Power Generation 0 power.cummins.com Generator set data sheet Model: Frequency: Fuel type: kW rating: Emissions level: C80 N6 60 Hz Natural gas/propane 80 natural gas Standby 80 propane Standby EPA Emissions Fuel consumption Natural gas Standby Propane Standby kw WA) kW (WA) Ratings 80 (100) 80 (100) Load 1/4 112 3/4 Full 1/4 112 314 Full scfh 450.5 671.5 867.7 1072.0 182.9 264.2 340.0 427.2 m3/hr 12.76 19.02 24.57 30.36 5.18 7.48 9.63 12.10 Engine Natural gas Standby rating Propane Standby rating Engine model QSJ5.9G-G3 Configuration Cast iron, in -line 6 cylinder Aspiration Turbocharged and after -cooled Gross engine power output, kWm (bhp) 121.3 (162.7) Bore, mm (in.) 102.1 (4.02) Stroke, mm (in.) 119.9 (4.72) Rated speed, rpm 1800 Compression ratio 8.5:1 Lube oil capacity, L (qt) 14.2 (15) Overspeed limit, rpm 2250 Fuel supply ressure Minimum operating pressure, kPa (in H2O) Maximum operating pressure, kPa (in H2O) 3.2 (13.0) -Air Natural gas Standby rating Propane Standby rating Combustion air, m3/min (scfm) 7.6 (268.1) 7.6 (269.1) Maximum normal duty air cleaner restriction, kPa (in H2O) 0.4 (1.5) 0.4 (1.5) Maximum heavy duty air cleaner restriction, kPa (in H2O) 3.7(15) 3.7(15) RECEIVED 1 6) ST Lucie L.ouncy, Permitting Our energy working for yom- 02018Cumm.ft. I NADi W-ENDCCX(12/18) power.cummins.com Natural gas I Propane Exhaust flow at rated load, ms/min (cfm) 23.0 (810.8) 21.2 (750.2) Exhaust temperature, °C (00 633.9 (1173.1) 644.0 (1191.2) Exhaust maximum back pressure, kPa (in H2O) 7(28.1) 7(28.1) Standard set -mounted radiator coolinal Ambient design, 'C (OF) 50 (122) Fan load, kW (HP) 9 (12) Coolant capacity (with radiator), L (US gal) 16(4.2) Cooling system air flow, m3/min (scfm) 218.0 (7700) Maximum cooling air flow static restriction, kPa (in H2O) 0.12 (0.5) Wei hts2 Unit dry weight kgs (Ibs) 1216 (2680) Unit wet weight kgs (Ibs) 1255 (2766) Notes: 1 For non-standard remote installations contact your local Cummins representative. 2 Weights represent a set with standard features. See outline drawing for weights of other configurations. Alternator data Natural gas/propane Full single single phase phase output, Standard alternators table Natural gaslpropane three phase table reconnectable Maximum temperature rise above 40 `C 120 `C 120 "C 120 9C 120 `G 120 'C 120 °G 120 'C ambient Feature code BB90-2 B986-2 B946-2 B943-2 B952-2 BB86-2 BB88-2 Alternator data sheet ADS-206 ADS-205 ADS-205 ADS-205 ADS-205 ADS-206 ADS-208 number Voltage ranges 120/240 120/240 120/208 277/480 347/600 127/220 120 - 480 Voltage feature code R104-2 R106-2 R098-2 R002-2 R114-2 R020-2 Varies by voltage Surge kW 96.9 103.4 103.4 103.2 103.2 103.2 Varies by voltage Motor starting Shunt 313 260 260 260 260 313 422 kVA (at 90 sustained PMG 368 306 306 306 306 368 497 voltage) Full load current amps 333 241 278 120 92 262 Varies by at Standby rating voltage Our energy working for you CZOta CIll111 Mhc. I NAD50W7ENZOCX(1018) power.cummins.com I Alternator data (continued) Natural Optional alternators gas/propane Full single for improved starting single phase phase output, capability table Natural gas/propane three phase table reconnectable Maximum temperature rise above 40 'C 105 `C 105 °C 105 `C 105 `C 105 'C 105 °C 105 `C ambient Feature code BB91-2 BB94-2 BB93-2 BB95-2 BB92-2 BB85-2 BB87-2 Alternator data sheet ADS-207 ADS-206 ADS-206 ADS-206 ADS-206 ADS-206 ADS-208 number Voltage ranges 120/240 120/240 120/208 277/480 347/600 127/220 120 - 480 Voltage feature code R104-2 R106-2 R098-2 R002-2 R114-2 R020-2 Varies by voltage Surge kW 97.7 102.8 102.8 103.6 103.6 103.6 Varies by voltage Motorstaning LShuMt 360 313 313 313 313 313 422 kVA (at 901/6 sustained PMG 423 368 368 368 368 368 497 voltage) Full load current amps 333 241 278 120 92 262 Varies by I at Standby rating voltage Derating factors Natural gastpropane Engine power available up to 1829 in (6000 ft) at ambient temperatures up to 40 `C (104 °F). Standby Above these elevations derate at 40/6 per 305 m (1000 ft) and 20% per 10 °C above 40 `C (104 -F). Retinas definitions Emergency Standby Power (ESP): Limited -Time Running Power (LTP): Prime Power (PRP): Base Load (Continuous) Power (COP): Applicable for supplying Applicable for supplying Applicable for supplying Applicable for supplying power to varying electrical power to a constant power to varying electrical power continuously to a load for the duration of electrical load for limited load for unlimited hours. constant electrical load for power interruption of a hours. Limited -Time Prime Power (PRP) is in unlimited hours. Continuous reliable utility source. Running Power (LTP) is in accordance with ISO 8528. Power (COP) is in Emergency Standby Power accordance with ISO 8528. Ten percent overload accordance with ISO 8528, (ESP) is in accordance with capability is available in ISO 3046, AS 2789, ISO 8528. Fuel Stop power accordance with ISO 3046, DIN 6271 and BS 5514. in accordance with AS 2789, DIN 6271 and ISO 3046, AS 2789, BS 5514. DIN 6271 and BS 5514. Formulas for calculating full load currents: Three phase output Single phase output kW x 1000 kW x SinglePhaseFactor x 1000 Voltage x 1.73 x 0.8 Voltage Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system except through an approved device or after building main switch is open. For more information contact your local Cummins distributor or visit power.cummins.com am Our energy working for you.^ C2018 Cummins Imx NI rights reserved Cummins Is a reystered trademark of Cummins Inc. Pe ,Command, ArrpSerdry, InPower acid Tur energy mddmg for you.- am harder ads of Cummins Inc. Morcmngany, product, or servce names nay be trademarks or service marls of ofhars. apearcatiors are subject b change WIVmn1 notice. 1A 61197- 14.130CX(12/18)