HomeMy WebLinkAboutSPECIFICATION SHEETSpecification sheet
SCANNED
BY
St. Lucie Coontl
RECEIVED
MAY 2 S 2919
ST. Lucie County, Permlttina
Quiet Connect`�N=
LAN REVIEW
Series BLDG:
DATE:
RS80 ELE
DATE: i t
PLUMB:
FILE C®Py DATE:
MECH:
Features and benefits DATE'
Robust product design and testing - The
generator is designed to operate under extreme
environmental conditions including cold weather
starts at as low as -40 OF when equipped with the
necessary accessories. The generator is tested
and certified per the latest EPA, UL and IBC
Seismic standards and is capable of meeting
NFPA110 requirements when equipped with the
necessary accessories and properly installed.
Flexible exercise mode - The innovative, flexible
exercise mode enables the generator to exercise
at a time, frequency and duration that suits the
customer's preference - as little as 2 minutes
every 6 months - reducing unnecessary fuel
consumption, emissions and noise.
C Power
Generation
Advanced enclosure design - The aesthetically
appealing enclosure incorporates special designs
that deliver the quietest generator of its kind.
Aluminum material plus durable powder coat paint
provides the best anti -corrosion performance. The
generator set enclosure has been evaluated to
withstand 180 MPH wind loads in accordance with
ASCE7-10. The design has hinged doors to
provide easy access for service and maintenance.
Self -diagnostics and easy service - The
generator is equipped with Cummins
PowerCommand® electronic control to provide
industry -leading selfdiagnostic capabilities. In
addition, critical components of the generator are
designed to ensure service and preventive
maintenance can be completed in a short period of
time.
Weight, size and sound level
Weight: 2782 lbs. (1262 kg)
Size: Length 118.7 in (3016 mm), width 40.0 in (1016 mm), height 58.3 in (1480 mm)
Sound: 70.5 dB(A) at 23 ft. (7 m) with sound level 2 enclosure
Series
Model
Phase
Voltage(V)
Frequency(Hz)
Rated amps'
(NG/LPVfuel)
Circuit hreaker
(Amps)
RS80
CBON6
1
1201240
60
333/333
125-400
3
120/208
60
278/278
1 125-400
3
120/240
60
241/241
70-250
3
277/480
60
120/120
150
' Dend ing guidelines: Engine power available up to 1829 m (6000 it.) at ambient temperatures up to 40 'C (104 19. Above these elevations
derate at 4 % per 305m (10001L) and 2 % per 10 `C above 40 `C (104 fl.
Our energy working for you.-
022016 CumMns Inc. I NAs-6170.4EN (eA6)
power.cummins.com
It
Product features Generator set performance
Governor regulation class: ISO 8528 Part 1 Class 33
Engine Voltage regulation, no load to full load: ±1.0%
• Natural gas/propane 1800 rpm engine Random voltage variation: ±1.0%,
• Engine air cleaner —normal duty Frequency regulation:Isochronous
• Electronic governor, isochronous Random frequency variation: ± 0.25%@ 60 Hz
• Engine starter, 12 VDC motor Radio frequency emissions compliance: FCC code
• Shutdown — low oil pressure • Extension —oil drain Title 47 part 15 Class B
• Engine oil — included
Fuel system
• Single fuel — natural gas or propane vapor, field
selectable
Alternator
• 60. Hz, 1 phase, 4 lead, or 3 phase, 12 lead, 120 °C
temperature rise at 40 •C ambient
• Exciter/voltage regulator —torque match
Control
• PowerCommand 1.1
• Display language — English
• Control mounting, left facing
Electrical
• Single circuit breaker, UL certified, right -side mounted
• Battery charging alternator, normal duty
• Battery charger —6Amp, regulated
Cooling
• Generator set cooling capability— 50 °C
• Shutdown —low coolant level
• Engine coolant —50150mixture
• Extension —coolant drain
Enclosure
• Aluminum enclosure Sound Level 1 with muffler
installed, sandstone color
• Wind rating —180 MPH
Code compliance
• UL 2200
• EPA emissions, stationary emergency, 40CFR60
• IBC Seismic
• NFPA110 capable
Generator set application
• Coolant heater
• Crankcase vent heater
• Battery rack
• Flexible fuel line
• Literature (English) —operator's manual, installation
manual
Warranty
• Base warranty — 2 year standby
• Extended warranties available
Packaging
• Shipping pallet
Our energy working for you.^
®2016 Qlmnins Inc. I NA"170-AEN (6/16)
Engine
Design: Turbocharged and aftercooled
Bore:102.1 mm (4.02 in)
Stroke: 119.9 mm (4.72 in)
Displacement: 5.9 liters (359 in3)
Cylinder block: Cast iron, in -line 6 cylinder
Battery capacity: 850 amps at ambient temperature of
0 OF to 32 OF (-18 °C to 0 °C)
Battery charging alternator: 52 amps
Starting voltage: 12 volt, negative ground
Lube oil filter type(s): Spin -on with relief valve
Standard cooling system: 500 C (1220 F) ambient
cooling system
Rated speed:1800 rpm
Fuel supply pressure
Minimum fuel supply pressure: 1.5 kPa (6.0 in H20)
Maximum fuel supply pressure: 3.5 kPa (14.0 in H20)
Control system
The PowerCommand® electronic control is standard
equipment and provides total generator set system
integration including automatic remote starting/stopping,
precise frequency and voltage regulation, alarm and
status message display, output metering, auto -shutdown
at fault detection and NFPA 110 Level 1 compliance.
Sound attenuated enclosure
The aesthetically appealing enclosure incorporates special
designs that deliver the quietest generator of its kind.
Aluminum material plus durable powder coat paint
provides the best anticorrosion performance. The
generator set enclosure has been evaluated to withstand
180 MPH wind loads in accordance with ASCE7-10. The
design has hinged doors to provide easy access for
service and maintenance.
pomr.cummins.com
Average fuel consumption
Fuel consumption —natural gas
Load:
1 1/4
1 1/2
314
Full
Ft3/hr.
1 455.3
1 678.7
877.0
1083.5
M'/hr:
1 12.9
1 19.2
24.8
30.7
Conversion factor.
8.58f3=1 lb
0.535m3=1 kg
36.39 W = 1 gal
Basic dimensions
/
DAMMURECLUIREn
rOOPEVYWORS
\
330 130
126.151 126.75)
Im
:Q90ai4M!9
CENTER Or
CENTER 01 ORAVITT—\
`SERVICE DOOR `SERVICE =3
MGM ME VIEW
IwRT►31AU
SERVICE PANEL
ICL
la.0
51R
fill
Fuel consumption — LP vapor
Load:
1/4
112
3/4
Full
Fe1hr:
181.9
263
339.8
1 420.8
MD/hr.::1
5.2
7.5
9.6
11.9
Gal/hr
5.00
7.23
9.34
1 11.56
AKE AREAS
TOPMEW
1016
[118.11
SERVICE PANEL SERVICE MR
1
145
Q
5. 11
A1R TLar
Io3
168
601
119
HI
[6.61 I23.91 // 125.31 lix.q
FUEL
J// 12117MEM W
[OnxECTIOV
Note: This outline drawing is provided for general reference only and is not intended for use in design or installation.
For more information, see Operators and Installation manuals or contact your distributor or dealer for assistance.
SERVICE MR
--x1 LATCH
Our energy working for you:
m2016 CAmnim 111c I NASS17PbEN (v16) powef.cummins.com
Accessories
• HMI211 RS in -home display, including pre -configured
12" harness
• HMI211 remote display, including pre -configured
12" harness
• HM1220 remote display
• Auxiliary output relays (2)
• Auxiliary configurable signal inputs (8) and relay
outputs (8)
• Annunciator—RS485
• Internet monitoring device —PowerCommand 500
• Battery chargers —stand-alone, 12V
• Enclosure Sound Level 1 to Sound Level 2 upgrade kit
• Enclosure paint touch up kit
• Base barrier— elevated generator set
• Alternator heater
• Maintenance and service kit
• Extreme cold weather kit for operating temperatures
below 0 OF (-17 eC)
9lendsyrmlrm 6esedon: AppBmbm 9edrmedm emarysydanem terse
ror•rpplyingare,gernyPoworrorma etecbxmbn•rNorprepeMdvroew
dm&bnotnormplposerlrttemgWn 0o nmwnnatto mry Wimmg
xowsrommoretom ep6mryro e1sWWevxytmtoW6mi�Pmvm
evallaElemrtNsrming(E@uvabum devimorMerdtlWmy malnbreeke�m
roCstoppowerinecm r open
15Oe018, A5rla9,onA2ll O1&o1 ere
W ssla) nomwiiY tea sw T W a
Contact your
North America
1400 73rA Avenue N.E.
Minneapolis, MN 55432
USA
Phone 763 574 5000
Fax 763 574 5298
more
Transfer switch (sold separately)
• Automatic Transfer Switches available in various
amperages.
• Service Entrance models are also available, which
helps reduce the installation cost.
• All models UL listed to UL 1008 standard.
• Available for both Indoor and Outdoor applications.
• Compatibility with Cummins generator set helps reduce
the installation time for the complete application.
Warranty policy
The Cummins RS and FIX liquid cooled generator set
models come with a 2 year base warranty when used in
EPA -Stationary Emergency application. The RA series
Automatic Transfer Switches come with a 2 year base
warranty. Extended warranty options are available.
Please contact Cummins dealers/distributors for details.
After sale support
Largest distributor/dealer support network
Cummins Power Generation generator sets are
supported by the largest and best trained worldwide
certified distributor/dealer network in the industry. The
network of knowledgeable and highly trained dealers will
help you select the right generator for your application
and advise you on associated accessories for your
generator. The dealer network can also help answer any
questions you may have regarding operation and
maintenances requirements of the generators. This same
network offers a complete selection of commonly used
generator set maintenance parts, manuals and
specification sheets.
Manuals: Operation and installation manuals ship with the
generator set. To obtain additional copies or other manuals
for this model, see your distributor/dealer. To easily locate
the nearest certified distributor/dealer for Cummins
generators in your area, or for more information, contact
us at 1-800-344-0039 or visit oower.cummins.com.
NEWMAN'S POWER SYSTEMS
3076 N KINGS HWY
FORT PIERCE, FL 34951
772-465-2490
Our energy working for you.-
ON16 Cummins Inc All rights reserved
Cummins is a registered trademark of Cumrrdns Inc
'Our energy working for you.- is a trademark o1 Cumnuns Power Generation. Other company, product, or service names
may be trademarks or service marks of others. Spedfications are subject to change witlmm notice.
NA"170iTEN (8116)
Power
Generation
0
power.cummins.com
Generator set data sheet
Model:
Frequency:
Fuel type:
kW rating:
Emissions level:
C80 N6
60 Hz
Natural gas/propane
80 natural gas Standby
80 propane Standby
EPA Emissions
Fuel consumption
Natural gas
Standby
Propane
Standby
kw WA)
kW (WA)
Ratings
80 (100)
80 (100)
Load
1/4
112
3/4
Full
1/4
112
314
Full
scfh
450.5
671.5
867.7
1072.0
182.9
264.2
340.0
427.2
m3/hr
12.76
19.02
24.57
30.36
5.18
7.48
9.63
12.10
Engine
Natural gas
Standby rating
Propane
Standby rating
Engine model
QSJ5.9G-G3
Configuration
Cast iron, in -line 6 cylinder
Aspiration
Turbocharged and after -cooled
Gross engine power output, kWm (bhp)
121.3 (162.7)
Bore, mm (in.)
102.1 (4.02)
Stroke, mm (in.)
119.9 (4.72)
Rated speed, rpm
1800
Compression ratio
8.5:1
Lube oil capacity, L (qt)
14.2 (15)
Overspeed limit, rpm
2250
Fuel supply ressure
Minimum operating pressure, kPa (in H2O)
Maximum operating pressure, kPa (in H2O) 3.2 (13.0)
-Air
Natural gas
Standby rating
Propane
Standby rating
Combustion air, m3/min (scfm)
7.6 (268.1)
7.6 (269.1)
Maximum normal duty air cleaner restriction, kPa (in H2O)
0.4 (1.5)
0.4 (1.5)
Maximum heavy duty air cleaner restriction, kPa (in H2O)
3.7(15)
3.7(15)
RECEIVED
1 6)
ST Lucie L.ouncy, Permitting
Our energy working for yom-
02018Cumm.ft. I NADi W-ENDCCX(12/18)
power.cummins.com
Natural gas I Propane
Exhaust flow at rated load, ms/min (cfm) 23.0 (810.8) 21.2 (750.2)
Exhaust temperature, °C (00 633.9 (1173.1) 644.0 (1191.2)
Exhaust maximum back pressure, kPa (in H2O) 7(28.1) 7(28.1)
Standard set -mounted radiator coolinal
Ambient design, 'C (OF)
50 (122)
Fan load, kW (HP)
9 (12)
Coolant capacity (with radiator), L (US gal)
16(4.2)
Cooling system air flow, m3/min (scfm)
218.0 (7700)
Maximum cooling air flow static restriction, kPa (in H2O)
0.12 (0.5)
Wei hts2
Unit dry weight kgs (Ibs) 1216 (2680)
Unit wet weight kgs (Ibs) 1255 (2766)
Notes:
1 For non-standard remote installations contact your local Cummins representative.
2 Weights represent a set with standard features. See outline drawing for weights of other configurations.
Alternator data
Natural
gas/propane
Full single
single phase
phase output,
Standard alternators
table
Natural gaslpropane three phase table
reconnectable
Maximum temperature
rise above 40 `C
120 `C
120 "C
120 9C
120 `G
120 'C
120 °G
120 'C
ambient
Feature code
BB90-2
B986-2
B946-2
B943-2
B952-2
BB86-2
BB88-2
Alternator data sheet
ADS-206
ADS-205
ADS-205
ADS-205
ADS-205
ADS-206
ADS-208
number
Voltage ranges
120/240
120/240
120/208
277/480
347/600
127/220
120 - 480
Voltage feature code
R104-2
R106-2
R098-2
R002-2
R114-2
R020-2
Varies by
voltage
Surge kW
96.9
103.4
103.4
103.2
103.2
103.2
Varies by
voltage
Motor starting
Shunt
313
260
260
260
260
313
422
kVA (at 90
sustained
PMG
368
306
306
306
306
368
497
voltage)
Full load current amps
333
241
278
120
92
262
Varies by
at Standby rating
voltage
Our energy working for you
CZOta CIll111 Mhc. I NAD50W7ENZOCX(1018)
power.cummins.com
I
Alternator data (continued)
Natural
Optional alternators
gas/propane
Full single
for improved starting
single phase
phase output,
capability
table
Natural gas/propane three phase table
reconnectable
Maximum temperature
rise above 40 'C
105 `C
105 °C
105 `C
105 `C
105 'C
105 °C
105 `C
ambient
Feature code
BB91-2
BB94-2
BB93-2
BB95-2
BB92-2
BB85-2
BB87-2
Alternator data sheet
ADS-207
ADS-206
ADS-206
ADS-206
ADS-206
ADS-206
ADS-208
number
Voltage ranges
120/240
120/240
120/208
277/480
347/600
127/220
120 - 480
Voltage feature code
R104-2
R106-2
R098-2
R002-2
R114-2
R020-2
Varies by
voltage
Surge kW
97.7
102.8
102.8
103.6
103.6
103.6
Varies by
voltage
Motorstaning
LShuMt
360
313
313
313
313
313
422
kVA (at 901/6
sustained
PMG
423
368
368
368
368
368
497
voltage)
Full load current amps
333
241
278
120
92
262
Varies by
I
at Standby rating
voltage
Derating factors
Natural gastpropane
Engine power available up to 1829 in (6000 ft) at ambient temperatures up to 40 `C (104 °F).
Standby Above these elevations derate at 40/6 per 305 m (1000 ft) and 20% per 10 °C above 40 `C
(104 -F).
Retinas definitions
Emergency Standby
Power (ESP):
Limited -Time Running
Power (LTP):
Prime Power (PRP):
Base Load (Continuous)
Power (COP):
Applicable for supplying
Applicable for supplying
Applicable for supplying
Applicable for supplying
power to varying electrical
power to a constant
power to varying electrical
power continuously to a
load for the duration of
electrical load for limited
load for unlimited hours.
constant electrical load for
power interruption of a
hours. Limited -Time
Prime Power (PRP) is in
unlimited hours. Continuous
reliable utility source.
Running Power (LTP) is in
accordance with ISO 8528.
Power (COP) is in
Emergency Standby Power
accordance with ISO 8528.
Ten percent overload
accordance with ISO 8528,
(ESP) is in accordance with
capability is available in
ISO 3046, AS 2789,
ISO 8528. Fuel Stop power
accordance with ISO 3046,
DIN 6271 and BS 5514.
in accordance with
AS 2789, DIN 6271 and
ISO 3046, AS 2789,
BS 5514.
DIN 6271 and BS 5514.
Formulas for calculating full load currents:
Three phase output Single phase output
kW x 1000 kW x SinglePhaseFactor x 1000
Voltage x 1.73 x 0.8 Voltage
Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's
electrical system except through an approved device or after building main switch is open.
For more information contact your local Cummins distributor
or visit power.cummins.com am
Our energy working for you.^
C2018 Cummins Imx NI rights reserved Cummins Is a reystered trademark of Cummins Inc. Pe ,Command, ArrpSerdry, InPower acid Tur energy mddmg for you.- am harder ads of
Cummins Inc. Morcmngany, product, or servce names nay be trademarks or service marls of ofhars. apearcatiors are subject b change WIVmn1 notice.
1A 61197- 14.130CX(12/18)