HomeMy WebLinkAboutWINDOW-DOOR SCHEDULE5UANNED BY St. Lucie County WINDOW/DOOR SCHEDUL ID NO APPROX OPENING SIZE WXH DESIGNATION ** TYPE IMPACT PROTECTION REMARKS IMPACT GLASS NEW SHUTTER EXISTING SHUTTER 1 37 X 37 PGT HR7610A HR X 18-0627.02 DP +65/-78.4 2 72 % X 37 PGT HR7610A HR X 18-0627.02 DP +65/-83.4 3 109 X 49 PGT HR7610A HR X 18-0627.02 DP +65/-104 4 138xs0 PGTSGD670 SL X 17-0420.09 DP +60/-102.9 5 6 7 8 9 VED 10 11 12 13 Lucie County, Permlt02g 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 *Window Replacement using existing shutters to comply with impact protection will require the existing shutters to meet the requirements ofthe 2010 FBCIResidential R301.2.1.2 TOTAL GLAZED OPENING AREA FOR STRUCTURE: 8.F. PERCENTAGE OF NEW GLAZED AREA: (TOTAL INSTALLED GLAZED AREA DIVIDED BY TOTAL GLAZED OPENINGS FOR STRUCTURE) NOTE: The replacement of more than 25 of the aggregate area of exterior glazing (windows & doors) in one & two family dwellings within a 12 month period will require impact protection on all proposed glazed opening replacement (approved shutters or impact resistant glazing) as per 20 10 FBCI EXISTING BUILDING 606.4. ** TYPE WINDOWS _SH—SINGLE HUNG AWN —AWNING SL—SLIDING DR —DOUBLE HUNG CAS —CASEMENT FIX —FIXED KEATING 10152 S OCEAN DR 215B JENSEN BEACH, FL 65-t/73 FILE COPY Building height Zone 4 Area 15 20 25 30 35 40 45 50 55 60 10 pos 46 48.5 50.4 52 53.2 54.5 55.7 56.7 57.6 58. neg 49.9 52.6 54.7 56.4 57.7 59.1 60.4 61.5 62.5 63.5 20 pos 44.1 46.5 48.3 49.8 51 52.2 53.4 54.3 55.2 56.1 neg 47.9 50.5 52.5 54.1 55.4 1 56.7 58 59 60 60.9 50 pcs 43 45.3 47 48.5 49.7 50.8 52 52.9 53.8 54.6 neg 45.1 47.5 49.4 50.9 52.1 53.3 54.6 55.5 56.4 100 pos 39.2 41.3 42.9 44.2 45.3 46.4 47.4 48.2 49 49.8 neg 43 45.4 47.1 48.6 49.8 50.9 52.1 53 53.9 54.8 500 pos 34.3 36.2 37.6 38.7 39.7 40.6 41.5 42.2 42.9 43.6 neg 38.2 40.3 41.8 43.1 44.2 1 45.2 46.2 1 47 47.8 48.6 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pos. 46 48.5 50.4 52 53.2 54.5 55.7 56.7 57.6 58.6 neg 61.7 65 67.5 69.6 71.3 73 74.7 75.9 77.2 I 78.4 20 pos 44.1 46.5 48.3 49.8 51 52.2 53.4 54.3 55.2 56.1 neg 57.5 60.6 63 64.9 66.5 68.1 69.6 70.8 72 73.2 50 pos 43 45.3 47 48.5 49.7 50.8 52 52.9 53.8 54.6 neg 51.9 54.8 56.9 58.7 60.1 61.5 62.9 64 65 66 100 pos 39.2 41.3 42.9 44.2 45.3 46.4 47.4 48.2 49 49.8 neg 47.9 50.5 52.5 54.1 55.4 56.7 58 59 59.9 60.9 500 pos 34.3 36.2 37.6 38.7 39.7 40.6 41.5 42.2 42:9 43.6 neg 38.2 40.3 41.8 43.1 44.2 45.2 46.2 47 47.8 48.6 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure D ( I MAY 2 9 2019 Wall component and Cladding pressures from Table R302.2(2) modified by adjust ent factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1 Sr. Lucie County, Permitting KEATI N G 10152 S. OCEAN DRIVE #2156 JENSEN BEACHIL