Loading...
HomeMy WebLinkAboutMISC LETTERM.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Ocean Blvd., Stuart, Fl. 34994 (772) 223-8227 * Lie. #AR91665 Date: December 02, 2019 `Sf e�NF To: St. Lucie County - Building & Code Regulation Division CI, Re: Robert Brennan 9500 S. Ocean Drive, Unit 406 (End) Jensen Beach, Fl. , 34957 It is acceptable to replace existing sliding glass door, picture window, & single hung window openings for the address listed above with units as follows: 1) S.G.D.- The EGS International "Atlantic" series S.G.D. has a Florida number NOA #17-1218.22 with a +105 / -130 design pressure. It has a large missile "D" approval and HVHZ. 2) P.W. - The EGS International Rampart series" 5500" Impact alum. picture window has a Florida number FL-#21899.1. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +100 /-130 design pressure and has a large missile "D" approval and HVHZ . 3) S.H. - The PGT "SH 700" alum. single hung window has a Florida number NOA- #17-0630.08. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +80 /-80 design pressure and has a large missile "D" approval and HVHZ . The actual building design pressures of address listed above in Zone 4 is +58.7 / - 63.7 The building has a type II classification and exposure category "D" for the 6th Edition of the FBC (2017). Worst case scenario has been calculated . Thank you for your time and consideration. If you have any questions please call. RespectfullY,` FILE COPY R VIEWED FOR Mark A.Cprson_A:LA.,NCARB CODE COMPLIANCE President - ST. LUCIE COUNT BOCC 0 (7 4