HomeMy WebLinkAboutMISC LETTERM.A. CORSON & ASSOCIATES, Inc.
ARCHITECTURE * STRUCTURAL DESIGN
412 Colorado Ave., Ocean Blvd., Stuart, Fl. 34994
(772) 223-8227 * Lie. #AR91665
Date: December 02, 2019 `Sf e�NF
To: St. Lucie County - Building & Code Regulation Division CI,
Re: Robert Brennan
9500 S. Ocean Drive, Unit 406 (End)
Jensen Beach, Fl. , 34957
It is acceptable to replace existing sliding glass door, picture window, & single hung
window openings for the address listed above with units as follows:
1) S.G.D.- The EGS International "Atlantic" series S.G.D. has a Florida number NOA
#17-1218.22 with a +105 / -130 design pressure. It has a large missile "D" approval and
HVHZ.
2) P.W. - The EGS International Rampart series" 5500" Impact alum. picture window
has a Florida number FL-#21899.1. The nominal wind speed is 132 mph and the ultimate
wind speed is 170 mph. It has a +100 /-130 design pressure and has a large missile "D"
approval and HVHZ .
3) S.H. - The PGT "SH 700" alum. single hung window has a Florida number NOA-
#17-0630.08. The nominal wind speed is 132 mph and the ultimate wind speed is 170
mph. It has a +80 /-80 design pressure and has a large missile "D" approval and HVHZ .
The actual building design pressures of address listed above in Zone 4 is +58.7 / -
63.7 The building has a type II classification and exposure category "D" for the 6th
Edition of the FBC (2017). Worst case scenario has been calculated .
Thank you for your time and consideration. If you have any questions please call.
RespectfullY,` FILE COPY
R VIEWED FOR
Mark A.Cprson_A:LA.,NCARB CODE COMPLIANCE
President - ST. LUCIE COUNT
BOCC 0 (7 4