HomeMy WebLinkAboutPRODUCT APPROVALBCIS Home Log In User Registration _ Hot Topics I Submit Surcharge Stabs & Facts I Publications Contact Us BCIS Site Map I Links Search
(cnda
Product Approval
d:,.pr 0 USER: Public User
Product Approval Menu > Product or Application Search > Audicabon List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
SCANNFD
St By
Lucie
C
FL22378-R6 �u1)ty
Revision
2017
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
0
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800) 663-3667
sschrelber@masonite.com
Steve Schreiber
sschreiber@masonite.com
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 201
year
1994
TAS 202
1994'
TAS 203
1994
Method 1 Option A
Date Submitted O1/25/2019
Date Validated 01/28/2019
Date Pending FBC Approval
Date Approved 02/04/2019
FL # I Model, Number or Name
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FL0170 for
anchor details and water performance where required.
Description
Opaque I/S Single
Certification Agency Certificate
FL22378 R6 C CAC NI007077.07-R2.odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL0170.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514010A ndf
FL22378 R6 AF 514014A.ndf
Created by Independent Third Partv: Yes
- 22378.2 Door Umtrd Fiberglass Side -Hinged 16'-8" Opaque O/S Single Door
=; .3 Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 3'-0" x V-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FL0170 for
anchor details and water performance where required.
_ 22378.3 I Stormguard Fiberglass Side -Hinged
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50.5/-50.5
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FL0170 for
anchor details and water performance where required.
22378.4 I Stormguard Fiberglass Side -Hinged
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55.0/-50.5
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FL0170 for
anchor details and water performance where required.
Certification Agency Certificate
FL22378 R6 C CAC NI007077.07-R2.ndf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 Ii FL0170 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AP 514010A.12df
FL22378 R6 AE 514014A odf
Created by Independent Third Party: Yes
6'-8" Opaque I/S Single or Double Door w/ or w/o Sidelites
Certification Agency Certificate
FL22378 R6 C CAC NI007077.07-R2 odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL0170.Odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514008A.odf
FL22378 R6 AE 514012A odf
Created by Independent Third Party: Yes
6'-8" Opaque O/S Single or Double Door w/ or w/o Sidelites
Certification Agency Certificate
EL22378 R6 C CAC NIO07077.07-R2 ndf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 f7 F10170.ndf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
F122378 R6 AE 514008A.ndf
FL22378 R6 AE 514012A.odf
Created by Independent Third Party: Yes
22378.5 Stormguard Fiberglass Side -Hinged 16'-8" Impact Glazed I/S or O/S Single Door w/ or w/o Sidelites
Door Unit
-. ..... ......-
',, Limits of Use ,
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55/-55
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 9'-0" x 6'-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO172 for
anchor details and water performance where required.
Certificatic, ;ency Certificate
FL22378 R. -,AC NI007077.09-R3 odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 iI FL 0172.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514008A.odf
Created by Independent Third Party: Yes
22378.6 Door Unit
Fiberglass Side -Hinged 1 6'-8" Impact Glazed I/S Double Door w/ or w/o Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-55
Other: Evaluated for use In locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO172 for
anchor details and water performance where required.
Certification Agency Certificate
FL22378 R6 C CAC NI007077 09-R3 odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL 0172.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514008A odf
FL22378 R6 AE 514012A.odf
Created by Independent Third Party: Yes
I.22378.7 ( Stormguard Fiberglass Side -Hinged 16'-8" Impact Glazed O/S Double Door w/ or w/o Sidelites
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55/-55
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO172 for
anchor details and water performance where required.
22378.8 I Stormguard Fiberglass Side -Hinged
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO171 for
anchor details and water performance where required.
22378.9 ( Stormguard Fiberglass Side -Hinged
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO171 for
anchor details and water performance where required.
Certification Agency Certificate
FL22378 R6 C CAC NI007077 09-R3.odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL 0172 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514008A odf
FL22378 R6 AE 514012A.odf
Created by Independent Third Party: Yes
8'-0" Opaque I/S Single Door
Certification Agency Certificate
FL22378 R6 C CAC NI007077.08 .odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL0171 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514009A.0df
FL22378 R6 AE 514013A.ndf
Created by Independent Third Party: Yes
8'-0" Opaque O/S Single Door
Certification Agency Certificate
FL22378 R6 C CAC NI007077.08 .ndf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL0171 ndf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514009A.odf
FL22378 R6 AE 514013A.ndf
Created by Independent Third Party: Yes
22378.10 1 Stormguard Fiberglass Side -Hinged 1 W-0" Opaque I/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50.0/-50.5
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO171 for
anchor details and water performance where required.
22378.11 Stormguard Fiberglass Side -Hinged
Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55.0/-50.5
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO171 for
anchor details and water performance where required.
Certification Agency Certificate
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL0171.ndf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514011A.Ddf
Created by Independent Third Party: Yes
8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites
Certification Agency Certificate
FL22378 R6 C CAC NIO07077 08 odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 IT FL0171.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AE 514007A.Ddf
FL22378 R6 AF S14011A.ndf
Created by Independent Third Party: Yes
122378.12 I Stormguard Fiberglass Side -Hinged 18'-0" Impact Glazed I/S Single or Double Door w/ or w/o
Door Unit Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +43/-47
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane
protective system Is NOT required. See DWG-MA-FLO173 for
anchor details and water performance where required.
Certification Agency Certificate
FL22378 R6 C CAC NIO07077.04-R6 odf
Quality Assurance Contract Expiration Date
Installation Instructions
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6-AE 514007A.ndf
FL22378 R6 AE 514011A.odf
Created by Independent Third Party: Yes
22378.13 I Stormguard Fiberglass Side -Hinged 8'-0" Impact Glazed O/S Single or Double Door w/ or w/o
Door Unit Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +47/-45
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane
protective system is NOT required. See DWG-MA-FLO173 for
anchor details and water performance where required.
Certification Agency Certificate
FL22378 R6 C CAC NI007077 04-R6 odf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL22378 R6 II FL 0173.Ddf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R6 AF 514007A.ndf
FL22378 R6 AE 514011A.Ddf
Created by Independent Third Party: Yes
say e
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275(I),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click bcuE.
Product Approval Accepts:
M PWM�111 � �kc_ >a
NOTICE OF PRODUCT CERTIFICATION
Company: Masonite International Corporation Certification No.:
1955 Powis Road Certification Date:
West Chicago, IL 60185 Expiration Date:
Revision Date:
N1007077.07-R2
05/22/2017
12/31/2020
05/02/2018
p 180 4� r' Product: Fiberglass Impact Rated Opaque Inswing or Ontswing Door w/ and w/o Impact Rated Sidelites
>;P" (w/Wood Frame or Worldwide Composite Frame' unless noted)
Specification: TAS 201/202/203-94/ASTM E330-02
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification
label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within
NAMI's Certified Product Listin at www.Nainicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI).
Inswing Glazed Structural Water Missile Test Report Number
Configuration or or Maximum Design Test Impact Drawing Number&
X
Single
1/S
Opaque
3'0" x 6'8"
+60/-65
0 psf
Yes
NCTL-210-3102-I/ATLNC 0129.02-15/ATLNC 10 1201-16
Maximum Panel Sim 3'0"x6'8"
Anchor Details-MA-FLOI70-07/W-I807
Single 1010"V ._,.5 pssff/'._r_.9.0 psi 4 •yam Maximum Panel Size: 3'0"x6'8"
7.5 psfs Anchor Details-MA-FL0170-07/W-1807/W-1835/W-1860
XX US Opaque 6'0" x 6'8" +501-50.5 0 psf Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Double Maximum Panel Size: 3'0" x 6'8"
Anchor Details-MA-FLO170-07/W-1807
XX O/S Opaque 6'0" s 6'8" +551-50.5 3.75 psf/ 6.0 psf I Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Double 8.25 psf 1/8.25 psf 4 Maximum Panel Size: 3'0" x 6'8"
XO/OX
I/S
Opaque Door
6'0"x 6'8"
+50.51-50.5
0psf
Door -Yes
NC'I'L-210-31U5-1/A'ILNCU129.01-15/A'1'LNCIU12.U1-16
Single w/Sidelite
Glazed Sidelite
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0"x6'8"
Anchor Details-MA-FL0170-07/W-1807
XO/OX
O/S
Opaque Door
6'0" x 6'8"
+551-50.5
3.75 psf/ 6.0 psf
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Singlew/Sidelite
Glazed Sidelite
8.25psf'/9.0psf4
Sidelite-Yes
Maximum Panel Size: 3'0"x6'8"/Sidelite::TO" x6'8"
Anchor Details-MA-FL0170-07/W-1807/W-1835
OXO
I/S
Opaque Door
9'0" x 6'8"
+50.51-50.5
0 psf
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012,01-16
Single w/Sidelites
Glazed Sidelite
Sidelite-Yes
Maximum Panel Size: 3'0" x CV/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
OXO
O/S
Opaque Door
9'0" x 6'8"
+551-50.5
3.75 psf/ 6.0 psf
Door -Yes
NCTL-210-3105-I/ATLNC 0129.01-15/ATLNC 1012.01-16
Singlew/Sidelites
Glazed Sidelite
8.25psf 2/9.0psf 4
Sidelite-Yes
Maximum Panel Size: .3'0"x6'8"/Sidelile:.3'0"x6'8"
Anchor Details-MA-FL0170-07/W-1807/W-1835
OXXO
US
Opaque Door
12'4" x 6'8"
+50/-50.5
0 psf
Door -Yes
NCTL-210-3105-I/ATLNC 0129.01-15/ATLNC 1012.01-16
Doublew/Sidelites
Glazed Sidelite
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
OXXO
O/S
Opaque Door
12'4" x 6'8"
+551-50.5
3.75 psf/ 6.0 psf
Door -Yes
NCTL-210-3105-I/ATLNC 0129.01-15/ATLNC 1012.01-16
Doublew/Sidelites
Glazed Sidelite
8.25 psf 1/8.25 psf I
Sidelite-Yes
Maximum Panel Size: 3'0"x6'8"/Sidelite:3'0"x6'8"
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE: _,�t4�
1111 MASONITE.
STORMGUARD FIBERGLASS DOOR UNIT
6' 6" DOUBLE DOOR WITH / WITHOUT SIDELITES
GENERAL NOTES
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED.
2. THIS PRODUCT DOES NOT REQUIRE THE USE OF
A HURRICANE PROTECTIVE SYSTEM (SHUTTERS).
3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
4. PLASTICS TESTING:
TF T ncanaiPnnu nvaruennu cerlun
SELF IGNrtION TEMP
ASTM D1929
752 'F > 650 'F
642 'F > 650 'F
RATE OF BURNING
ASTM D635
0.56 IN MIN
1.28 IN MIN
SMOKE DENSITY
ASTM D2843
53.4%
70.2%
TENSILE STRENGTH' I
ASTM D638
3.2% DIFF
1.8% OFF
5. PIASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED):
TRT ❑FSCRIPTION )FSIGNATON RFCIIIT
SELF IGNITION TEMP
I ASTM DI929
1 779 'F > 650 'F
PATE 0E BURNING
ASTM D635
0.0 IN MIN
SMOKE DENSITY
ASTM D2843
39.0%
TENSILE STRENGTH'
ASTM D638
3.6%. DIFF
" COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
I
149' MAX. OVERALL FRAME WIDTH
21" MAX 36.375" MAX.
D.L.O, - PANEL WIDTH I - 37.5" MAX. Y W/ASTRAGAL IT FRAME WIDTH
-LL
m � �
x � S
a
� III !1! III Ali II ill
11 III
ICI I��
ill Ili
I
III �I�
�I III
STRUCTURAL
DESIGN PRESSURE
RATING
WHERE WATER INFILTRATION PERFORMANCE IS
REQUIRED TO BE 15% OF DESIGN PRESSURE
CONFlG
MA%.WIDTH INSWING
ALL OUTSWING
INSWING
BUMPER O S
Z-SERIES 0 S
HP 0 S
T4 0 5
HIGH DAM 0 5
X
37.5 +60.0 -65.0
+60.0 -60.0
N A
-4D.0
+50.0 -50.0
+60.0 -60.0
+60.0 -60.0
+55.0 -50.5
N A
+25.0 -25.0
+40.0 -40.0
N A
+55.0 -50.5
+55.0 -50.5
0% or XO
75 +50.5 -50.5
+55.0 -50.5
N A
+25.0 -25.0
0
+40.0 -40.0
N A
+55.0 -50.5
+55.0 -50.5
OXO
112.5 +SOS -50.5
+55.0 -50.5
N A
+25.0 -2,
+40.0 -40.0
N A
+55.0 -50.5
+55.0
OXXO
149 +50.0 -50.5
+55.0 -50.5
N A
+25,0 -25.0
+40. 1 -40.0
N A
+55.0 -50.5
+55.0 -5D.5
_ TABLE OF CONTENTS
SHEET #1 DESCRIPTION
W
KURT RALTHAZOR
FLORIDA P.E.
156533
In
a -
p O
O
O
3 c�D
2 d U
ti to U
LL)
03 ��
W
W:
SEE DETAIL
.D.
#8 x 2"
#8 x 2"
6' SEE DETAIL 3.
j E.
6
1 3' ---1 i-3•
��
3"
I I I
i
_
_
W
y
_
A
_w
B
o
a
oB
,
6" 3 _
�� 11Ir
6•
-�
II
c Y 3 t
3" 3' _ 3•
6'
SEE DETAIL
'F.
#10 x 5/8"
#10 x 5/8"
#10 x 1"
#10 x 2-1/2"
#10 x 1"
#10 x 5/8"
DETAIL "C"
0.9621 ■
p
\. \ •� l•_� BUMPER • HA.. ••.• HP O/S THRESHOL
: fjU�" �, .. fl
'L
3"
3'
6 #8 x 2"
E5 I
DETAIL "E" ASTRAGAL
ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME
AS SHOWN.
mill
r asulm wd
EE DETAIL
C.
6.
ASTRAGAL RETAINER BOLT HOLE
MUST BE DRILLED THROUGH
THE THRESHOLD & INTO THE
STRUCTURE DEEP ENOUGH
FOR A 1.375" THROW
DETAIL "F" ASTRAGAL
m& d"W"
owamm r a
mtowDe '
r ixsvrto oAv
CC91AlM i311i 0.1SP M/]
]✓ '0.1 a6o- SMd (ru 1}Im].Ip 1M ]�!
-1]]V. 0.1]f IPY ARWTO.'m N' m0.
an.- vAi
CNY LY]F1 pW IYI]pL
Im
0.W IPM1] 611mCIX6m
AI}.
W"'L fMll 011 MLIK YKG
1/Y SIL
—TI—
TYPICAL GLAZING DETAI
IMPACT RATED GLASS
fGIIYL IW1. M KIY 9VILG ix�i�tiC 1/9' 9K
c co
UQ
0 (p
O0�
<tn0
U
CL _
��U
Q F-
N
CTw
M.... N.T.S. '
owc. ar. SWS
fK
f
6" —
3' --I 3" I —
MIN
� � e
U
a SEE DETAIL
J'D" SHT, 2
� o
SEE DETAIL
'C' SHT. 2
i y I
ATTACHMENT DETAIL
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY ROBERTO LOMAS, PE
(FLORIDA #62514) WITH THE LOWEST (LEAST) 1M2IN
7' 'A .
0.15'
FASTENER RATING FROM THE DIFFERENT FASTENERS MAX
BEING CONSIDERED FOR USE. JAMB, HEAD, AND SHIM
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CLI-
#10 WOOD SCREWS, 1 4' TAPCONS, AND #10 TEK SCREWS..e�'�,:
A PHYSICAL SHIM ML77977IC= SHIM SPACE AT EACH
ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2".
WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE TYPICAL MASONRY
DISTANCE MIN 1/2". ANCHOR INSTALLATION
2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO 7�
ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. (> '
3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM
ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE
MINIMUM EMBEDMENT OF 1-1/4".
4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO
TRANSFER LOADS TO STRUCTURE.
5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS.
6
3° 1 L
C c -- I I 3l
0
—
w
I II
j--oG V
II II
II 11
B
% 6" 4 t 6" y — 1—"6" 3, I
1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED
AT 5-1/2" CENTERLINE.
— 0.25'
SHIM
CL — —
�i
1X BUCK MASONRY
ANCHOR INSTALLATION ,
BUTT HINGES.
1'X1/2" CORRUGATED #IOX2' WOOD SCREW
3' FROM EACH END 6' FROM EACH END
AND 7" OC AND 12" CC
( ACRYLIC
CAULK
A A EMX
CAULK CL
:OMBINATION WOOD COMBINATION WOOD
MULLION (BOXED) MULLION (BOXED)
CL
TYPICAL WOOD BUCK
ANCHOR INSTALLATION INTEGRAL WOOD
MULLION (CHS)
(4 gq1OX2-1/2'
00D SCREWS
EACH END
A
INTEGRAL WIN
MULLION (CHS)
W:
OF
L. Roberto Lomas P.E.
1432 Woodford Rd.
Manufacturer. Masonite
Lewisville. NC 27023
Report #. 514010A
434-688-DW9
Date: 10/10/2017
rllomas,51domasDe. corn
Test Report: N/A
Product: Single door Tx 6'8" (Wood Frame)
Scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code.
Anchor capacity in shear condition:
Solid members w/ 8 w/out gap:
a. With threads present in shear plane
Fastener Type: #10 wood screw
(NOS 2012, NOS 2015, TR12)
Nominal diameter: D: 0.190 in
Gap: g: 0.0000 in
Root diameter: Or: 0.152 in
Moment arm: 0.0000 in
Minimum required penetration: p: 1.140 in
Screw bending yield strength: Fy= 80,000 psi
Side member: Douglas Fir -Larch (G-050)
Main member: Spruce -Pine -Fir (6=0.42)
Side member thickness: tr= 1.000 in
Main member thickness: tm= 1.500 in
Side member dowel bearing strength: F„= 4.650 psi
Main member dowel bearing strength: Fa,= 3.350 psi
Side member dowel bearing length: I.= 1.000 in
Main member dowel bearing length: 1„= 1.140 in
Made h,
qm= 636.5 lbs/in
P= 725.61 lbs
Ko= 2ADO
Z,,,= 302 lbs
Mode I.
qs = 884 Ibs/in
P = 884 lbs
Ko = 2.400
Z,- 368 lbs
Min. Design wIue: Z= 110 Ibs
Duration Factor: Co= 1.6
Made II
A: 0.0007
B: 1.07
C:-427.674
P= 331 lbs
Ka = 2.400
Z= 138 Ibs
Made III
A: 0.00097
8: 0.57
C:-253.623
Ms = 46.8 in-lbs
p = 297 lbs
Ko= L,100
Z= 124 lb.
Fastener type: 1/4 1TW Tapcan Tabulated wNas
N.O.A. 16-122206
Substrate: Hallow black
Minimum embedment: 1.25 in
Actual edge distance: 250 in
Made III,
A:
0.00107
8:
0.5
C:
-267.699
Mm=
46.8 in-lbs
P =
319 Ibs
Kro =
2,400
Z=
133 Ibs
edge
distance
apac1-9 fin)
2.00
4.00
2.00
130
161
4.00
163
202
Actual C To C spacing: 3.00 in
Allowable Design Value: Z..= 155 lbs/anchor four iaternalothm when neededl
Tabulated design wiue: Z= 1266 lbs
Safety factor: Fs= 4 _
Allawable Design Value (ZFs): Z'= 316 Ibs/anchor
Minimum anchor capacity: 155 Ibs/anchar
Note. Anchorswith N¢ least capaelryis used /or calculations ro qualiyanchors wiN higher capacity.
Anchor calculations. minimum reaufred anchors
36.38 Design pressure: 85.0 psi
M1 79.25
1 of 3
Max.
Anchor
Area
Load
Ind.
Cap.
qty
I
Load
I
(fir') a)
(lbs)
(in)
O.C.
Result
(in)
(Ibs)
(Ibs)
A,
2.3
195
N/A
N/A
155
2
98
OK
Ar
7.7
656
6.001
18.00
1 155
5
1 131
OK
Mode IV
A: 0.00135
8: DODD
Ca -93.6
p= 263 lbs
Kb = 2,400
Z= 110 Has
\S 11�1 I !L/j///�/i
i
t• 0 51 •1t�
;; STATE OF
'OFSORtdQ: G� %
1
111ONAL1E \\`�
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P. E
1432 WO0r//Ord Ra, ManUlacturer: Masonite
LeMsnne. NC 27023 Report #: 514010A
434-668-06o9 Date: 10/10/2017
rllomasAlrlomasoe com
Anchor Locations:
i38
tBA9
6.00 NP. 6.00 NP.
6.00
1 e•
MAX
O.C.
79.25
J-
6.00
2of3
„6251 •1k —
�� TAT OF
m�?G��\
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P.E.
1432 WWdI0rd Rd.
Manufacturer: Masonite
teMwille. NC 22023
Report #. 514010A
434-6BB-0609
Date: 10/10/2017
rllomaspirlonlaspe corn
Installation instructions:
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW.
2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW.
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.00D PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048') FY=33KSVFU=52KSI OR ALUMINUM 6063-T5 FU=30KSI
.052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN.
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD.
8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL.
10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
3of3
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
1 of 3
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville. NC 27023
434-68&0609
Manufacturer: Masonite
Report#: 514014A
Date: 10/10/2017
rllDmas(ci)Irlomasoe.com
Test Report: N/A
Product: Single door 3'x6'6' (Composite frame)
Scope;
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Flodda Building Code.
Anchor capacity in shear condition:
Solid members w/ 6 /out gap:
a. With threads present in shear plane
Fastener type: 910 wood screw
Nomml diameter D: 0.190 in
(NOS 2012, NDS 2015, TR12)
rap: g: 0.0000 in
Auer diameter: Or: 0.152 in
Moment arm: 0.0000 in
Minimum required penetration: p: 1140 in
Screw bending yield strength: F,= 80,000 psi
Side member: PVC
Main member: Spruce -Pine -Fir (G=0.42)
Side member thickness: ;= 1A00 in
Main member thickness: t•= 1.500 in
Side member dowel bearing strength: F.= 10.000 psi
Main member dowel bearing strength: F., = 3,350 psi
Side member dowel bearing length: 1,= 1.000 in
Main member dowel bearing length: 1,= 1.140 in
Made In Mode I, Mode II
Mode III• Mode III,, Mode IV
qm= 636.516s/in qs= 190016s/in A: 0.0005
A: 0.00066 A: 0.00092 A: 0.00105
P= 725.61 lbs P= 1900 lbs B: 1.07
8: 0.57 8: 0.5 8: 0.000
Ko= 2.400 Ko= 2.400 C: .681.799
C: .253.623 C. -521.824 C: -93.6
Z,= 302 lbs Z,= 792 lbs P= 510 lbs
Ms= 46.8 in-lbs Mm= 46.8 fir-lbs
Ko = 2.400
P = 324 lbs P = 529 lbs P = 299 lbs
Min. Design value: Z= 125 lbs Z= 212 lbs
Ka= 2.400 Ko= 2AGO Ko= 2.400
Duration Factor: Ca= 1.6
Z= 135 lbs Z. 221 lbs Z= 125 lbs
Allowable Design Value CZCo): Z'= 199 lbs/anchor
Fastener type: 1/4 rM Tapcon
Tabulated values
N.O.A. 16-1222.06
edge
spvchg (in)
Substrate: Hallow block
distance
2.00 4.00
Minimum embedment: 1.25 in
1 2.00
130 161
Actual edge distance: 2.50 in
4.00
163 1 02
Actual C To C spacing: 3.00 in
Allowable Design Value: Z"= 155 lbs/anchor (per Interpolation when needed)
Fastener type: 910 Self tapping screw
(Calculations per 2015 Aluminum Design Manual, section 7.&5)
Nominal screw diameter: D: 0.190 in
Screw root area: A, 0,0151 ine
Actual edge distance: de: 1.085 in
Screw shear ultimate strength: F. 54.0 ksi
Per table 33.2 of 2010 Steel Construction Manuel lath Edition
Side member material: Vinyl PVC
Main member material: 6063-T5 aluminum
Thickness: tI 1.000 in
Thickness: to 0,052 in
Ultimate tensile strength: Fwn 14 ksi
Ultimate tensile strength: F.e 22 ksi
Nominal strengthper bearing(sidemembery Rn=2Dt,Ft,,,
Rnl= 5320 lbs (Eq 7.5-12)
Nominal strength per bearing (main member): An 20t,,F,„ t
Rn2 = 435 lbs (Eq 7.5-12)
Nominal strength per tilting: Rn= 4.2(te31))v2f,.,,e
Rn= 478 lbs (Eq 7.5-13)
Nominal screw shear strength: Rn=A.Fw/1.25
Rn= 654 lbs (Eq 3.5-14)
Safety factor: n= 3
Allowable he., and bearing capacity: P. 145 lbs/anchor
Fastener type: #to 5d1' tapping screw
(Calculations per AISI-S100-12, sections A2.3.2 and E4.3.1)
Nominal screw diameter: D: 0.190 in
Screw shear ultimate strength: F,,, 54.0 ksi
Screw root ores: A, 0.0151 ine
Per table 73.2 of 2010 Steel Construction Manual 14th Edition
Side member material: Vinyl PVC
Main member material: Metal framing
Thicknus: tI LWO in
Thickness: to ^^•^'_
Ultimate tensile strength: F. 14 ksi
Ultimate tensile strength: Fa�r�/////
Nominal strength per tilting: An= 4.2(t23O)Ir1F12
Rn= 1001 lbs (Eq E4.3.1-1) � �. `O,��/�i
Nominal strength per bearing (side member): An 2.7DtIF,
AN = 7182 lbs (Eq E4.3.1-2 and 4) �N J\ e • e 4I
Nominal strength per bearing (main member): Rn= 2.7DieF,a
Rn2 = 1280 Ibs E4.3.1-3 •'\r E N .ram
(Eq and -5) ` �• s�'9s
Nominal screw shear strength: Rn=A,Fw/1.25
Rn= 654 lbs
Safety factor: 0=3
w 0 C7551
*.
Allowable shear and bearing capacity: P. 218 Ibs/amMor
y`' •
t
Minimum anchor capacity: 145 lbs/anchor
C`/'
��
TAT d F •
Note: Anchors with Me least cepaeiryls used for calculations to qualityanchors with highereepeeity. ��O . kI
N
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P.E.
1432 WWdrORI Rd.
Lewisville. NC 27023
434-688-0609
rl lomas,7lrlomasoe_ccm
Manufacturer Masonite
Report #. 514014A
Date: 10/1012017
Anchor calculations. minimum reauiredanchors
36.38 Design pressure: 85.0 psf
f
I
2 A2 79.25
Al
Zone
Area
(frz)
Load
(Ibs)
Ind.
(in)
Max.
O.C.
(in)
Anchor
Result
Cap.
(Ibs)
QtY
Land
(Ibs)
Al
2,3
195
N/A
WA
145
2
98
OK
Az
7.7
656
6.00
18.00
145
5
131
R
Anchor Locations:
38.38
t e.19
6.00 7YP. 6.00 NP.
6.00
I
18'
MAX
O.C.
79.25
6.00
2of3
\\\\J\s %�lII1Ll0/7i
�.••��CENS�'9s�y
*• 0 51 •yt=
STATE OF ; w0 ID
z�ssVoNA��eG�
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P. E-
1432 WWdbro Rd. Mawfaciurer. Masonite
Le.s.le. NC 27023 Report #. 514014A
434-688-0609 Date: 10/10/2017
rllomas(cl rloma soe.com
Installation instructions: -
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW.
2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Frn=2,000PS1 MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI
.052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN.
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD.
8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL.
10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
3 of 3
Oki I 11L O
13-.4T((A�ATTE OF
�8`S; ..� ORIOP GN�
NAhEa��`�
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017