Loading...
HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTPAUL J. FORD &COMPANY Date: May 1, 2019 SCANNED Andera Slaughter BY Crown Castle St. Lucie County 8000 Avalon Blvd, Suite 700 Alpharetta, GA 30009 Subject: Carrier Designation: Crown Castle Designation: Engineering Finn Designation: Site Data: Dear Andera Slaughter, Structural Analysis Report AT&T Mobility Co -Locate Carrier Site Number: Carrier Site Name: Crown Castle BU Number: Crown Castle Site Name: Paul J. Ford and Company 250 East Broad st., Suite 600 Columbus, OH 43215 (614)921-6679 10080462 FP33 (MINUMAID) 813700 MINUTE MAID BRA360 Crown Castle JDE Job Number: 553217 Crown Castle Work Order Number: 1694638 Crown Castle Order Number: 475132 Rev. 4 Paul J. Ford and Company Project Number: 37519-0281.002.8700 R1 2651 Minute Maid Road, Ft. Pierce, St. Lucie County, FL Latitude 27' 29' 0", Longitude -800 34' 1.3" 250 Foot - Self Support Tower Paul J. Ford and Company is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. The purpose of the analysis is to determine acceptability of the tower -stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 153 mph as required by the 2017 Florida Building Code, 6t^ Edition. Applicable Standard references and design criteria are listed in Section 2- Analysis Criteria. Respectfully submitted by:\\\N\n(C LEE yA�////, Matthew Buske,P.E. Project Engineer mbuske@pauliford.com * No. 80107 STATE OF ly i \. A CORIOP 6� \� 10` NAL\\ot,i� FILE COP V MAY 012019 tnxTower Report - version 8.0.4.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No 813700 Project Number 37519-0281.002.8700, Order 475132, Revision 4 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 — Tower Component Stresses vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations - — A tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0261.002.8700, Order475132, Revision 4 1) INTRODUCTION May 1, 2019 CCI BU No 813700 Page 3 This tower is a 250 ft Self Support tower designed by FWT INC. in May of 1998. The tower was originally designed for a wind speed of 110 mph per TIA/EIA-222-F. The tower has been modified multiple times in the past to accommodate additional loading. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 153 mph Exposure Category: C Topographic Factor: 1 Service Wind Speed: 60 mph Table 1 - Proposed Equipment Configuration . Center:- a. Mounting iner Number An Antenna ' ' Number Feed¢ ' mLeyel(ft) of . EleJation Antenna Model Manufacturer ofkFeed Line Antennas Lines . Size (in} �• .. c' _.°'; fin) F. _°. � . , e ; t. 3 commscope SBNHH-1D85C ericsson RRUS 32 1 200.0 1„ ericsson RRUS 4449 B5/B12 6 1 5/8 � 195.0 yll u 1 W� ericsson RRUS 8843 B2/B66A 3 3/4 1 _.... ra ca DC6-48 60 18-8F 4 3/8 PVFM12-3-3-96 Sector I 195.0 1 connect -it Frame 2 ericsson J RRUS 32 2 ericsson RRUS 4449 135/B12 2 edesson RRUS 8643 B2/866A 14 1 5/8 160.0 160.0 6 3/4 kathrein 80010966K 3 raycap DC6-48 60-18-BF PVFM12 3 3 96 Sector 2 connect -it Frame tnxTower Report - version 8.0.6.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 Table 2 - Other Considered Equipment May 1, 2019 CC/ BU No 813700 Page 4 Cent-er"— Number' 'gU [rs, Level(ft W,-ountVnx ElbVaton ;Antenna MAnt A rof Feed Une) :7ne a Antennas ,anu�acurer 'NFeed i Size(m) 1 decibel 932DG33T2A-M 238.0 2 decibel 950G65VTZE-M 237.0 1 9 1 om kathrein 742218 237.0 j 1 tower mounts Side Arm Mount [SO 1 305- 3] 3 --- decibel DB848H105ESX 225.0 224.0 i decibel DB878H120ESX 6 15/8 224-0 J­ _?]_tower mountsl Sector Mount [SM 409-1] 3 andrew, SBNHH-ID65C 6 celimax CMA-BDHH/6520/EO-8 technologies 217.0 217.0 3 12 15/8 nokia FRIG 3 11/4 6 nokia FXFB 2 rayGap RNSNDC-7771-PF-48 1 tower mounts Sector Mount [SM 404-3] 2 cci antennas HPA33R-CS4AA-K1 1 commscope TTTT65AP-lXR 3 ericsson RRUS 31 B25 210.0 3 ericsson RRUS82 W/SOLAR SHIELD 207.0 3 ericsson RRUS-1 1 800MH2 3 1 3/32 3 rfs celwave ACU-A20-N i rfs celwave I APXV9ERR18-C-A20 2 tower mounts Sector Mount [SM 301-1] 207.0 --- 1 tower mounts j Sector Mount [SM 502-1] 180.0 j 3 decibel D 848HI05ESX 1780 178.0 1 tower mounts Sector Mount [SM 409-1] 3 15/8 1 1 radiowaves SPD2-5.8 i 128.0 128.0 1 1/2 i I tower mounts I Pipe Mount [PM 601-1] 1 andrew j HPX6-59-P3A/K I 1 120.0 120.0 1 cet tower mounts Pipe Mount [PM601-1] I I tnxTower Report -version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 3) ANALYSIS PROCEDURE Table 3 - Documents Provided May 1, 2019 CC/ BU No 813700 Page 5 a < - ** bocument' ••., - `` .." Remarks eference ""R Source GEOTECHNICAL REPORTS PSI, #397 85050-3, 10/12/1998 429429 CCISITES POST -MODIFICATION B&T/Morrison Hershfield, INSPECTION #82906.002/6110008.00/CNO- 3041481 CCISITES 223R8, 10/14/11 TOWER FOUNDATION PSI, #772-80085-16a, 12/07/1998 447987 CCISITES DRAWINGS/DESIGN/SPECS TOWER MANUFACTURER FWT, #16922, 05/15/1998 245820 CCISITES i DRAWINGS -------------- TOWER REINFORCEMENT Morrison Hershfield, #6013009, 3106450 CCISITES DESIGN/DRAWINGS/DATA 06/01/2001 TOWER REINFORCEMENT B&T Engineering, #82906.002, 2918494 CCISITES DESIGN/DRAWINGS/DATA 7/7/2011 3.1) Analysis Method tnxTower (version 8.0.5.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. t 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Paul J. Ford and Company should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) 'Section tJo.3" - Elevation (ft) .. .4 Component Type . s _. Size . _ Critical; Element' - " P (K) . ; SF"P allow - (K) °/, ' - capacity Pass / Fail is ;. ._ , , :.. °. _ T1 ?: 250-240 E Leg - 2"solid 2 -1.84 51.75 3.6 Pass T2 j 240-220 Leg 3' solid 20 t -18.51 144.96 j 12.8 Pass T3 ! 220 - 200 Leg 3 112" solid 41 -68.39 246.21 I 27.8 Pass T4 1200 - 1 B6.667 4 Leg 4' solid 61 -110.81 371.28 29.8 Pass T5 1186.667 - 180 } Leg 4" solid 76 -132.10 371.28 j 35.6 Pass T6 180 - 160 ) Leg 4' solid 86 -193.01 446.95 g 43.2 Pass T7 160-140 Leg 41/4'solid 107 -270.24 522.41 } 51.7 Pass T8 g 140 - 120 Leg 4 1/2" solid 128 347.23 602.61 ; 57.6 Pass T9 120 - 100 Leg 4 3/4" solid 149 -425.94 687.57 61.9 Pass T10 i 100 - 80 ; Leg 5" solid 170 -482.62 783.48 1 61.6 Pass T11 j 80 - 60 Leg 5' solid 215 1 71.9 Pass T12 60-40 Leg 51/4"solid 260 -637.60 877.46 72.7 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 6 Component ' eal t-§`No �"' ElevaBon {B} Type ,,SlzeF4 + �' Element Pj�#r ' +{IQs Ca ac Ity +Pass 1 Falt e . r '°Y may:" p - ,', _(`-5' T13 g 40 - 20 Leg 5 1/2° solid 318 716.41 976.23... 73.4 Pass T14 i 20 - 0 Leg . 5 3/4" solid 375 }-792.65 1079.75. _ 73.4 Pass T1 250-240 Diagonal L2x2x3/16 7. -0.88 15.66 5.6 Pass ` T2 ii 240 - 220 Diagonal g L 3 x 3 x 3/16 27 { 4.67 26.87 p{ 17.4 Pass 8 _125.2.(b). _ T3 # 220 - 200 Diagonal L 3 x 3 x 1/4 48 } -10.11 29.97 4 ib) Pass r� 41 T4 200 - 186.667 Diagonal L 3 x 3 x l/4 68 -11.76 25.46 446 (b).. _ Pass .. 5.3. 18 T5 # 186.667 - 180 # Diagonal 2L 3 x 3 x 1/4 (3/8) 83 -12.24 80.04 2(b) _. Pass _ T6 Z 180 - 160 Diagonal 2L 2.5x 2.5 x 3/16 (112) 92 -15.38 31.54 1 48.8 .__....._.__.. Pass T7 160 - 140 Diagonal - -- 2L 2.5 x 2.5 x 3/16 (1/2) 111... -18.38 26.31 -- 69.8 Pass - t T8 140 - 120 Diagonal 2L 3 x 3 x 3116 (1/2) 134 -21.09 37.83 55. 3 (b) Pass- t 58.4 T9 120 - 100 Diagonal 2L 3 x 3 x 3/16 (1/2) 155 -24.97 33.07 75.5 Pass _ T10 100 - 80 } Diagonal 2L 3 x 3 x 5/l6 (1/2) 187 35.98 55.28 65.1 Pass I T11 80 - 60 .. Diagonal 21. 3 x 3 x 5/16 (1/2) 232_ _ -35.49 49.67 _.. 71.4 Pass # T12 # 60 40 Diagonal 2L 3 x 3 x 1/4 (1/2) 279.. E 38.65 70.43 7 6' (b) Pass _ T13 i 14 40 - 20 Diagonal 21. 3 x 3 x 5/16 (112) 336 -38.24 81.35 47.0 Pass 66.0 (b) T14 # , 20 - 0 Diagonal 2L 3 x 3 x 5/16 (112) 393 -40.28 76.16 _ ( 52.9 1 69.5 (b)- -- _ _Pass- -- T10 ( I 100 80 Horizontal 2L 2.5 x 2.5 x 3/16 (1/2) 172 -8.37 21.54 i 38.9 Pass ! -- - d 40.2 (b) T11 80 - 60 t Horizontal 2L 2.5 x 2.5 x 3/16 (1/2) 217 j -9.77 17.89 54.6 Passe- T12 60-40 Horizontal 2L 2.5 x 2.5 x 3/16 (1/2) 262 -11.06 15.12 T13 40 - 20 ) Horizontal 2L 3 x 3 x 3/16 (1/2) 326 -12.42 22.12 ? 56.2 Pass T14 20-0 Horizontal 2L 3 x 3 x 3/16 (1/2) 392.. -13.75 19.14 71.8 Pass a T6 180 - 160 Secondary Horizontal .. L 2.5 x 2.5 x 3/16 94 -3.44 10.67 i 32.2 33.0 (b)_ Pass 3 T7 160 - 140 Secondary L 3 x 3 x 3116 115 -4.69 14.12 .. j 33.2 Pass ( - Horizontal i 40.8 (b) TB 140 - 120 Secondary L 3 x 3 x 3/16 136 -6.02 11.04 54.5 Pass Horizontal � Secondary L 3 x 3 x 1/4 157 -7.39 11.56 t 63.9 Pass ( Horizontal j Tt ; 250 - 240 ( Top Girt L 2 x 2 x 3/16 5 -0.12 J 6.81 j 1.8 Pass T10 100 - 80 Redund Horz 1 2L 2 x 2 x 3/16 (1/2) 181 -8.37 1 37.60 ' i 22.3 Pass Bracing I T11 80 - 60 � Redund Horz 1 2L 2 x 2 x 3/16 (1!2) 222 � 9.77 34.30 1 28.5 Pass Bracing i T12 60-40 Re rz 1 2L2x2x3/16 (1/2) 271 -11.06 30.68 36.0 Pass B c ng R T13 40 - 20 1 Redund 1 2L 2 x 2 x 3/16 (1/2) 331 -12.42 26.74 46.5 - Pass ( Bracingng T14 ) 20 - 0 Redund Horz 1 I 2L 2 x 2 x 3/16 (1/2) 388 -13.75 23.14 59.4 Pass Bc _ T10 100 - BO RedB cD9 g 1 2L 2 x 2 x 3/16 (112) 204. -5.93 22.31 26.6 Pass T11 ' 80 - 60 Redund 1 2L 2 x 2 x 3/16 (1/2) 246 -6.64 20.05 , 33.1 Pass inniag Bracg T12 60-40 Re Brdo'�Dngg1 2L2x2x3/16(1/2) 297 -7.26 18.14 40.0 Pass T13 + 40 - 20 Redund Dia 1 9 2L 2 x 2 x 3/16 (1/2) 360 -7. 22 16.45 ' 48.1 Pass Bracing tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 7 Section Elevation QQ, CohiponentType• sl�L Critical P-jK) SF*P_allow -A `(K) Pass I 7F�f Element Capacity T14 20-0 Redund Diag 1 2L 2.5 x 2.5 x 3/16 (1/2) 422 -8 .55 28.64 29.8 Pass Bracing..,._ 9 - -,-- I I --J--, F T12 60-40 Reli.in� Hip I L 2.5 x 2.5 x 3/16 314 -0.10 11.81 0.9 Pass Bra "'g T13 40-20 RedundHip 1 L2.5 x2.5x3/16 342 0.09 10.12 0.9 Pass J� Bracing ......... ...... . .. T14 20-0 Redund Hip 1 L 2.5 x 2.5 x 3/16 428 -0.09 8.78 1.0 Pass Bracing -------- ----- ---- - Redund Hip T12 60-40 Diagonal 1 L 2.5 x 2.5 x 3/16 315 -0.14 3.31 4.3 Pass Bracing Redund Hip T13 40-20 Diagonal 1 L 2.5 x 2.5 x 3/16 372 -0.12 2.91 4.1 Pass Bracing Redund Hip T14 20-0 Diagonal 1 L 2.5 x 2.5 x 3116 429 -0.12 2.57 I 4.7 Pass Bracing T10 100-80 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 195 -0.03 10.31 0.3 Pass ["T11 80-60 2 x 3/16 (3/8) 240 -0,03 8.59 0.4 Pass F-112 60-40 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 290 -0.06 7.27 0.8 Pass T13 40-20 Inner Bracing 2L 2.5x 2.5 x 3/16 (318) 347 -0.08 12.48 0.6 Pass T 2.5 x 3/16 (318) 404 -0.04 10.81 0.4 Pass {Summary Leg J14) I 73.4 Pass Di(Ti?)-agonal 75.6 Pass -- Horizontal 1, 73.1 Pass (T 12) Secondary Horizontal 63.9 Pass Top Girt 1.8 Pass M) Redund Horz I T 59.4 Pass, Bracing (T14) Redund Diag 1 I 48.1 Pass I ff Bracing (T13) • Redund Hip 1 Bracling 1.0 Pass (T14) Redund Hip Diagonal 1 4.7 Pass Bracing (T14) Inner Pass 1Bolt Checks; 75.6 Pass Rating = 1 75.6 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 5 - Tower Component Stresses J May 1, 2019 CC/ BU No 813700 Page 8 1 ( Anchor Rods (......._._..__. ) 82.8 t Pass --- ------- - Base Foundation 1,2 (Compared w/ - 90.4 Pass Notes: 1) See additional documentation in "Appendix C —Additional Calculations for calculations supporting the % capacity consumed. 2) Foundation capacity determined by comparing analysis reactions to original design reactions. 3) All structural ratings are per TIA-222-H Section 15.5 4.1) Recommendations • The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. 1 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order475132, Revision 4 APPENDIX A TNXTOWER OUTPUT May 1, 2019 CCI BU No 813700 Page 9 tnxTower Report - version 8.0.5.0 250.0R 9 C e i i I a m xl I I jJl I !I I Ijl !xl zl I s I ai z � I I I I I.6 I=I I I � I o I N al I I^I I;q) n' j ill. cl Ix I � Iml ice'. =i Icl rjrl z x i lei Icl c ^� - hl I I^i w j4 "e I m m u. IJm. m` s xOlolfl ejaiaj m n �!Oj0 F 2 W KK p5 �g li R �i 240OR 220Ofl II�/��1� - 2000n t 1867 flfl 180.011 1600fl Boon ) l� 60.0 fl' 40_0 R I' 20.0R �. DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE I ELEVATION Beams 250 (2)RRUS-11800MH2 1207 ! 119Nhurg Ra05Rx4' 2W HPA R-CSO K1-1M RN 12(W 932DG33T2A-Mw/Ma Rpe M7 RRU592ww0 sHIELD .207 j !742218w/Mw MW 237 ACU-A20N 1207 950G6SYRE-Mw/Maml Rpe 237 Swim Ma [am 301-1] '2W 95pGW'V�d:M w/Maml Rpe 237 Sector Ma ISM 301-11 12W ISideMm MOM1503053] 237 S Mamt[SM m2-1] !M7 (3)DBs48H105ESxw/Mwml Pipe 224 (3)SBNHH-1D85Cw/Ma Rpa !195 (3)DB878H120ESxw/Mwm1Rp0 =4 RRUS32 Jim Swim Mam1I5M409-1] 224 RRUS 4449 B51912 110 Seem Mamt[SM409-11 T24 RRUS SW B2/BWA i195 ' SBNHH-1D65C w/MwiM1 Rpa 217 OC6<Bfi0l1 .195 I SBNHH-1DWW/Mm PiM 217 P 1233985etlar Frame 195 j SSNHH-1D65Cw/Ma Rpe 217 (3)DBHEBH105ESX w/Maurt Rpe !178 - (2)CMA-BDHHI85201E68 217 Seam Mamt piMd09.1] 1I8 (2)CMA-BDMHI652dE68 217 (2) D06dB50-188F Jim 1(2) CMA-WHHI6521VE08 217 RRUS 32 1160 FRIG 217 RRUs 444985'B12 '180 FRIG 217 RRUs 8B43B2IB884 160 !FRIG 217 (3)80010866Kw/Mamt RN Jim j RNSNDC-Trr1-PF 217 RRUs 32 1160 RNSNOC-7RI-PF-0B 217 RRUS 4449 M12 Jim(2)FXFB 217 RRUS8843B2/866. Jim (2)FXR3 217 (3)&xnmswW/Ma Rpe '160 i(2)F 217 DC640-6 i1 11m SetlarMmrM1 ISM 40431 217 P 1233965ecbr Rene Jim TT7TBSM imw/Maml RN 207 P 123998rFrame 1W 1(2)RRUS 31 Ras 47 RpeM.1[PM 601-1] i128 RRUSa2W15p SHIF 2W sPD2-6.8 lin I 1RRUS1180DMH2 M7 0Oe0Nc5m Wt '125 I(2)ACu-a2aN zD7 ocswamuam 125 1 pPXV9ERRi8C.A20 wfmq Rpe 207 ObaW timli9M 1125 ! ,HPA33RLSIAAK1 w/MavBRpa M7 RBEAIR1500HP �12 IRRUS31 B25 arr jgwmq [PM601-1] Jim RRUS 82 W/SOLAR SHIELD IW7 HPx649PWK 1120 MATERIAL STRENGTH GRADE Fy Fu 1 GRADE ! Fy Fu jA .m JWW low 1A36 1361 WW 1 TOWER DESIGN NOTES 1. Tower designed for Exposure C to the TIA-222-H Standard. 2. Tower designed for a 153.00 mph basic wind in accordance with the TIA-222-H Standard. 3. Deflections are based upon a 60.00 mph wind. 4. Tower Risk Category II. 5. Topographic Category 1 with Crest Height of 0.00It 6. TIA-222-H Annex S 7. TOWER RATING: 75.6% ALL REACTIONS AREFACTORED MAX. CORNER REACTIONS AT BASE: DOWN: 830 K SHEAR: 96 K UPLIFT., -712 K SHEAR: 85 K AXIAL /128 KK SHEAR/ j \ MOMENT TORQUE 274 kip-ft REACTIONS-153.00 mph WIND Paul J. Ford and Company " 250-ft Self 250 East Broad St., Suite 600 "I'BU11B13700 Columbus, OH 43215 G1Q1h Crown Caste Phone: (614) 221.6679 Cade' TIA-222-H Dort Tower Ft. Pierce m'w N. 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 Tower In ut Data May 1, 2019 CCI BU No 813700 Page 10 The main tower is a 3x free standing tower with an overall height of 250.00 ft above the ground line. The base of the tower is set at an elevation of 0.00 ft above the ground line. The face Width of the tower is 6.00 ft at the top and 30.00 ft at the base. This tower is designed using the TIA-222-H standard. The following design criteria apply: 1) Tower base elevation above sea level: 24.00 ft. 2) Basic wind speed of 153.00 mph. 3) Risk Category II. 4) Exposure Category C. 5) Simplified Topographic Factor Procedure for wind speed-up calculations is used. 6) Topographic Category: 1. 7) Crest Height: 0.00 ft. 8) Deflections calculated using a wind speed of 60.00 mph. 9) TIA-222-H Annex S. 10) A non -linear (P-delta) analysis was used. 11) Pressures are calculated at each section. 12) Stress ratio used in tower member design is 1.05. 13) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile 4 Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) SR Members Have Cut Ends SR Members Are Concentric Options Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wind Area Use Clear Spans For KUr Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area of Appurt. Autocalc Torque Am Areas Add IBC .6D+W Combination Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feed Line Bundles As Cylinder Ignore KUry For 60 Deg. Angle Legs Use ASCE 10 X-Brace Ly Rules 4 Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feed Line Torque 4 Include Angle Block Shear Check Use TIA-222-H Bracing Resist Exemption Use TIA-222-H Tension Splice Exemption Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Comer Radii Are Known tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 Wind 180 Len A Wind 90 -► ��� em Q m Leg C i Z Leg B Face C Wind Normal Triangular Tower -- ` °Tower Section Geometry, May 1, 2019 CC/ BU No 813700 Page 11 Tower Tower Assembly Desorption Section Number Section Section Elevation Database Width of Length Sections ft ft ft T1 250.00-240.06 6.00 1 10.00 T2 240.00-220.00 6.00 1 20.00 T3 220.00-200.00 8.00 1 20.00 T4 200.00-186.67 10.00 1 13.33 T5 186.67-180.00 11.33 1 6.67 T6 180.00-160.00 12.00 1 20.00 T7 160.00-140.00 14.00 1 20.00 T8 = 140.00-120.00 16.00 1 20.00 T9 120.00-100.00 18.00 1 20.00 T10 100.00-80.00 20.00 1 20.00 T11 80.00-60.00 22.00 1 20.00 T12 60.00-40.00 24.00 1 20.00 T13 40.00-20.00 26.00 1 20.00 T14 20.00-0.00 28.00 1 20.00 Tower Section Geometryfcorit'al , Bottom Girt Tower Tower Diagonal Bracing Has Has Top Girt Section Elevation Spacing Type K Brace Horzontals Offset Offset End It It Panels in in Tt 250.00-240.00 5.00 X Brace No No 0.000 0.000 T2 240.00-220.00 6.67 X Brace No No 0.000 0.000 T3 220.00-200.00 6.67 X Brace No No 0.000 0.000 T4 200.00-186.67 6.67 X Brace No No 0.000 0.000 T5 186.67-180.00 6.67 X Brace No No 0.000 0.000 T6 180.00-160.00 10.00 X Brace No Yes 0.000 0.000 T7 160.00-140.00 10.00 X Brace No Yes 0.000 0.000 - T8 140.00-120.00 10.00 X Brace No Yes 0.000 0.000 T9 120.00-100.00 10.00 X Brace No Yes 0.000 0.000 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CCI BU No 813700 Page 12 Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section , Elevation Spacing Type KBrace Horizontals Offset Offset End ft ft Panels in in T10 100.00-80.00 10.00 Double K1 No Yes 0.000 0.000 T11 80.00E0.00 10.00 Double K1 No Yes 0.000 0.000 T12 60.00-40.00 10.00 Double Kt No Yes 0.000 0.000 T13 40.00-20.00 10.00 Double K1 No Yes 0.000 0.000 T14 20.00-0.00 10.00 Double K1 No Yes 0.000 0.000 Tower Section Geometry (cont'd Tower Leg Leg Leg Diagonal Diagonal Diagonal Elevation Type Size Grade Type Size Grade T1 250.00- Solid Round 2" solid A572-50 Equal Angle L 2 x 2 x 3/16 A35 240.00 (50 ksi) (36 ksi) T2 240.00- Solid Round 3" solid A572-50 Equal Angle L 3 x 3 x 3116 A36 220.00 (50 ksi) (36 ksi) T3 220.00- Solid Round 3 1/2" solid A572-50 Equal Angle L 3 x 3 x 1/4 A36 200.00 (50 ksi) (36 ksi) T4 200.00- Solid Round 4" solid A572-50 Equal Angle L 3 x 3 x 1/4 A36 186.67 (50 ksi) (36 ksi) T5 186.67- Solid Round 4" solid A572-50 Double Equal 2L 3 x 3 x 1/4 (3/8) A36 180.00 (50 ksi) Angle (36 ksi) T6 180.00- Solid Round 4" solid A572-50 Double Equal 2L 2.5 x 2.5 x 3/16 (112) A36 160.00 (50 ksi) Angle (36 ksi) T7 160.00- Solid Round 4 1/4" solid A572-50 .Double Equal 2L 2.5 x 2.5 x 3/16 (1/2) A36 140.00 (50 ksi) Angle (36 ksi) T8 140.00- Solid Round 4 1/2" solid A572-50 Double Equal 2L 3 x 3 x 3/16 (1/2) A36 120.00 (50 ksi) Angle (36 ksi) T9 120.00- Solid Round 4 3/4" solid A572-50 Double Equal 2L 3 x 3 x 3/16 (1/2) A36 100.00 (50 ksi) Angle (36 ksi) T10 100.00- Solid Round 5" solid A572-50 Double Equal 2L 3 x 3 x 5116 (1/2) A36 80.00 (50 ksi) Angle (36 ksi) T11 80.00- Solid Round 5" solid A572-50 Double Equal 2L 3 x 3 x 5/16 (1/2) A36 60.00 (50 ksi) Angle (36 ksi) T12 60.00- Solid Round 5 1W' solid A572-50 Double Equal 2L 3 x 3 x 1/4 (1/2) A36 40.00 (50 ksi) Angle (36 ksi) T13 40.00- Solid Round 5 1/2" solid A572-50 Double Equal 2L 3 x 3 x 5/16 (112) A36 20.00 (50 ksi) Angle (36 ksi) T14 20.00-0.00 Solid Round 5 3/4" solid A572-50 Double Equal 2L 3 x 3 x 5116 (1/2) A36 (50 ksi) Angle (36 ksi) Tower Section Geometry cont'd Tower Top Girt Top Girt Top Girt Bottom Girt Bottom Girt Bottom Girt Elevation Type Size Grade Type Size Grade It T1 250.00- Equal Angle L 2 x 2 x 3116 A36 Equal Angle A36 240.00 (36 ksi) (36 ksi) Tower Section Geometry cont'd Tower No. Mid Girt Mid Girt Mid Girt Horizontal Horizontal Horizontal Elevation of Type Size Grade Type Size Grade Mid ft Gins T10 100.00- None Single Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 A36 80.00 (36 ksi) Angle (1/2) (36 ksi) tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 13 Tower No. Mid Girt Mid Girt Mid Girt Horizontal Horizontal Horizontal Elevation of Type Size Grade Type Size Grade Mid It Girls T11 80.00- None Single Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 A36 60.00 (36 ksi) Angle (112) (36 ksi) T12 60.00- None Single Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 A36 40.00 (36 ksi) Angle (1/2) (36 ksi) T13 40.00- None Single Angle A36 Double Equal 2L 3 x 3 x 3/16 (1/2) A36 20.00 (36 ksi) Angle (36 ksi) T14 20.00-0.00 None Single Angle A36 Double Equal 2L 3 x 3 x 3/16 (1/2) A36 (36 ksi) Angle (36 ksi) = Tower.Section`Geomet cont'd Tower Secondary Secondary Horizontal Secondary Inner Bracing Inner Bracing Size Inner Bracing Elevation Horizontal Type Size Horizontal Type Grade Grade it T6 180.00- Equal Angle L 2.5 x 2.5 x 3/16 A36 Equal Angle L 2 x 2 x 3/16 A36 160.00 (36 ksi) (36 ksi) T7 160.00- Equal Angle L 3 x 3 x 3116 A36 Equal Angle L 2 x 2 x 3/16 A36 140.00 (36 ksi) (36 ksi) T8 140.00- Equal Angle L 3 x 3 x 3/16 A36 Equal Angle L 2.5 x 2.5 x 3116 A36 120.00 (36 ksi) (36 ksi) T9 120.00- Equal Angle L 3 x 3 x 1/4 A36 Equal Angle L 2.5 x 2.5 x 3116 A36 100.00 (36 ksi_) ksi)_ T10 100.00- _ Equal -Angle - - - - A36 Double Equal 2L 2 x 2 x 3/16 (3/8) __(36 A36 80.00 (36 ksi) Angle (36 ksi) T11 80.00- Equal Angle A36 Double Equal 2L 2 x 2 x 3/16 (3/8) A36 60.00 (36 ksi) Angle (36 ksi) T12 60.00- Equal Angle A36 Double Equal 2L 2 x 2 x 3/16 (3/8) A36 40.00 (36 ksi) Angle (36 ksi) T13 40.00- Equal Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 (3/8) A36 20.00 (36 ksi) Angle (36 ksi) T14 20.00-0.00 Equal Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 (3/8) A36 (36 ksi) Angle (36 ksi) ',-Tower Section Geometry contd .. Tower Redundant Redundant Redundant KFactor Elevation Bracing Type Size Grade T10 100.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3/16 (1/2) 80.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3/16 (1/2) Double Equal Angle T11 80.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3116 (1/2) 60.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3116 (112) Double Equal Angle T12 60.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3116 (1/2) 40.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3/16 (1/2) Hip (1) Double Equal L 2.5 x 2.5 x 3/16 Hip Diagonal Angle L 2.5 x 2.5 x 3/16 (1) Equal Angle Equal Angle T13 40.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3/16 (1/2) 20.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3116 (1/2) Hip (1) Double Equal L 2.5 x 2.5 x 3116 Hip Diagonal Angle L 2.5 x 2.5 x 3/16 (1) Equal Angle tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CCI BU No 813700 Project Number 37519-0281.002.8700, Order 47513Z Revision 4 Page 14 Tower Redundant Redundant Redundant KFactor Elevation Bracing Type size Grade it Equal Angle T14 20.00- A36 Horizontal (1) Double Equal 21- 2 x 2 x 3/16 (1/2) 1 0.00 (36 ksi) Diagonal (1) Angle 2L 2.5 x 2.5 x 3/16 (1/2) 1 Hip (1) Double Equal L 2.5 x 2.5 x 3/16 1 Hip Diagonal Angle L 2.5 x 2.5 x 3/16 1 (1) Equal Angle Tower Section Geometry cont'd Tower Gusset Gusset Gusset GradeAdjust. Factor Adjust. Weight Mult Double Angle Double Angle Double Angle Elevation Area Thickness Ar Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) A, - Spacing Spacing Spacing Diagonals Hodzonta/s Redundants it fF in in in in T1 250.00- 2.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 240.00 (36 ksi) T2240.00- 0.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 220.00 (36 ksi) T3 220.00- 0.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 200.00 (36 ksi) T4 200.00- 0.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 186.67 (36 ksi) T5 186.67- 0.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 180.00 (36 ksi) T6 180.00- 0.00 0.375 A36 1.03 1 1.1 47.400 Mid -Pt Mid -Pt 160.00 (36 ksi) T7 160.00- 0.00 0.375 A36 1.03 1 1.1 26.175 Mid -Pt Mid -Pt 140.00 (36 ksi) TB 140.00- 0.00 0.375 A36 1.03 1 1.1 57.480 Mid -Pt Mid -Pt 120.00 (36 ksi) T9 120.00- 0.00 0.375 A36 1.03 1 1.1 31.380 Mid -Pt Mid -Pt 100.00 (36 ksi) T10 100.00- 0.00 0.500 A36 1.03 1 1.1 39.400 58.500 Mid -Pt 80.00 (36 ksi) T11 80.00- 0.00 0.500 A36 1.03 1 1.1 42.000 64.500 Mid -Pt 60.00 (36 ksi) T12 60.00- 0.00 0.500 A36 1.03 1 1.1 44.000 70.500 Mid -Pt 40.00 (36 ksi) T13 40.00- 0.00 0.500 A36 1.03 1 1.1 46.400 76.500 Mid -Pt 20.00 (36 ksi) T14 20.00- 0.00 0.500 A36 1.03 1 1.1 49.000 82.500 Mid -Pt 0.00 (36 ksi) Tower Section Geometry cont'd K Factors' Tower Calc Calc Legs X K Single Gids Hodz Sec. Inner Elevation K K Brace Brace Diags Horiz Brace Single Solid Diags Diags Angles Rounds X X X X X X X It Y Y Y Y Y Y Y T1250.00- No No 1 1 1 1 1 1 1 1 240.00 1 1 1 1 1 1 1 T2 240.00- No No 1 1 1 1 1 1 1 1 220.00 1 1 1 1 1 1 1 T3 220.00- No No 1 1 1 1 1 1 1 1 200.00 1 1 1 1 1 1 1 T4 200.00- No No 1 1 1 1 1 1 1 1 186.67 1 1 1 1 1 1 1 T5186.67- No No 1 1 1 1 1 1 1 1 tnxTower Report - version 8.0.6.0 W ANOI�NOproNaoA� T�t>t�AN W NNNN.-. R7y OAN �000000000000000000�ol W �O�OONO NNAN ooc{o oo�o N O' O. O. O. O. OI. O. O. O. �,�myF O' O' O• O 0 O O 000. c O O O O O o 0 0 0 V o 0 0 0 0 0 0 m p 1 0 09 0 o p p o 0 V � 0 0 0 0 � 0 0 0 0 0 o 0 O 0 0 0 0 0 O 0 o 0 o o O c o o O 0 O o o g e O O O O O O O O O O O O O O »$ m O O o O o 0 0 o O O o O o 0 o O 0 0 0 0 0 0 0 0 0 0 0 o a o 0 0 ogy�m Z � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ^>•^ 0 0 0 0 0 0 0 0 0 0 0 0 0 o m N N C ^ fJT fJll tJl� tJT IVII N N fJT N N N N 0 0 0 0 0 0 0 0 0 0 0 0 0 o m^ O O O O G G G O O O O O O O 0 c ti 0 0 0 0 0 0 0 0 0 0 0 0 o 0 O 0 o 0 O 0 0 0 0 0 o 0 O 0 ^� 0 0 o O o 0 o O o o O o 0 o a N C 4Ji tJll N N N N N N N N VJi fVli N 0 o O o o O O 0 0 0 0 0 0 o O 0 0 0 0 0 0 o c c o 0 0 0 ognRX m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �� •� o 3 0 0 0 0 0 0 o O o o O o 0 0 N C a. IJT fJT (Jll UVi fJlf UJI IJT IJT fJT UVi fJl� IJT N O O O O O O O O O O O O O O 0 S 2 ^l ^ O O O O O O O O O O O O O O Ji C c� 0 0 0 0 0 0 0 0 0 0 C vi vJi ai a O o 0 o O O O 0 0 0 o O O o 0 0 2 O O O O a O O O O O O a O O [� S•• IQ O O O O O O O O O O O O O O O N ut Ut N N N ut Vt Ut N N N N tit O O O O O O O O O O O O O O C,cn 0 O O O O O O O O O O O O O O O O O O O O O 0: p O O O O O O O O O O O O O O O O O O O O C + x w C O O O O O O O O O O O O O O N' U1 N ut N N N N Vt N Ut N Ut U1 Vt m ON A. DI. O. OONOAOOlOmO 00000000 O' O' O' O' �o a d Z Z Z `Z Z Z Z Z Z 0 0 0 0 0 0 0 0 0 me - 0 a3 0 0 0 0 0 0 0 0 0 l0 �O JC N N � n Om <k��� m Om <kmax 122 O O O O p fT N in r 250 Ft Self Support Tower Structural Analysis Project Number 3 7519-0281.002.8 700, Order47513Z Revision 4 Tower Section Geometry cont'd May 1, 2019 CCI BU No 813700 Page 16 Tower Elevation It Leg Connection Type Leg Bolt Size No. Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. in in in in in in in T1250.00- Flange 0.625 4 0.625 2 0.625 1 0.000 0 0.625 0 0.000 0 0.000 0 240.00 A325N A325N A325N A325N A325N A325N A325N T2 240.00- Flange 0.875 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.000 0 220.00 A325N A325N A325N A325N A325N A325N A325N T3 220.00- Flange 1.000 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.000 0 200.00 A325N A325N A325N A325N A325N A325N A325N T4 200.00- Flange 1.250 0 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.000 0 186.67 A325N A325N A325N A325N A325N A325N A325N T5186.67- Flange 1.250 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.000 0 180.00 A325N A325N A325N A325N A325N A325N A325N T6180.00- Flange 1.250 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.625 1 160.00 A325N A325N A325N A325N A325N A325N A325N T7160.00- Flange 1.250 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.625 1 140.00 1A325N A325N A325N A325N A325N A325N A325N T8140.00- Flange 1.375 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.625 1 120.00 A325N A325N A325N A325N A325N A325N A325N T9120.00- Flange 1.500 6 0.625 2 0.000 0 0.000 0 0.625 0 0.000 0 0.625 1 100.00 A325N A325N A325N A325N A325N A325N A325N T10100.00- Flange 1.500 6 0.625 2 0.000 0 0.000 0 0.625 0 0.625 1 0.625 0 80.00 A325N A325N A325N A325N A325N A325N A325N T1180.00- Flange 1.500 6 0.625 2 0.000 0 0.000 0 0.625 0 0.625 1 0.625 0 60.00 A325N A325N A325N A325N A325N A325N A325N T12 60.00- Flange 1.750 6 0.625 2 0.000 0 0.000 0 0.625 0 0.625 1 0.000 0 40.00 A325N A325N A325N A325N A325N A325N A325N T13 40.00- Flange 1.750 6 0.625 2 0.000 0 0.000 0 0.625 0 0.625 1 0.000 0 20.00 A325N A325N A325N A325N A325N A325N A325N T14 20.00- Flange 2.500 0 0.625 2 0.000 0 0.000 0 0.625 0 0.625 1 0.000 0 0.00 A36 A325N A325N A325N A325N A325N A325N Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Face Allow Exclude Componen Placement Face Lateral # # Clear Width or Pedmete Weight or Shield From t Offset Offset Per Spacin Diameter r Leg Torque Type ff in (Frac FW) Row g in pff Calculation in in LDF7.50A(1- A No No 5/8") LDF7-50A(1- A No No 518") 1.5" flat A No No Cable Ladder Rail LDF7-50A(1- A No No 5/8") 3X4AWG(1 A No No 114) 1.5" flat A No No Cable Ladder Rail " Face B"*"* 1.5" Flat B No No FWT Climb Ladder Rail 3/16" safety B No No cable tnxTower Report - version 8.0.5.0 Ar (CaAa) 178.00 - -0.500 0.25 12 12 1.000 1.980 0.82 0.00 0.500 Ar (CaAa) 237.00 - -0.500 0.25 9 9 1.000 1.980 0.82 178.00 0.500 Af (CaAa) 237.00 - -0.500 0.25 2 2 36.000 1.500 1.80 0.00 0.500 Ar (GaAs) 217.00 - -6.000 -0.22 12 4 1.000 1.980 0.82 0.00 0.500 Ar (Calks) 217.00 - -1.000 -0.2 3 3 1.000 1.300 0.88 0.00 0.500 Af (CaAa) 217.00 - -0.500 -0.21 2 2 36.000 1.500 1.80 0.00 0.500 Af (CaAa) 250.00 - 0.000 0 2 2 12.000 1.500 1.80 0.00 0.000 Ar (CaAa) 250.00 - 0.000 0 1 1 0.250 0.188 0.35 0.00 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 17 Description Face Allow Exclude Componen Placement Face Lateral # # Clear Width or Perimete Weight or Shield From t Offset Offset Per spacin Diameter r Leg Torque Type ft in (Fiac FM Row g in pff Calculation in in LCF158- B No No Ar (CaAa) 224.00 - 1.000 0.25 6 6 1.000 2.010 0.92 50J(1-5/8") 0.00 0.500 ' 1.5" flat B No No Af (CaAa) 224.00 - 0.000 0.25 2 2 18.000 1.500 1.80 Cable Ladder 0.00 0.500 Rail LDF5- B No No Ar (Calks) 128.00 - -0.500 -0.25 1 1 1.910 1.090 0.33 50A(7/8") 0.00 0.500 TSZ 999 B No No Ar (CaAa) 207.00 - -0.500 -0.23 3 2 1.000 1.039 0.71 066/xxxM- 0.00 1.039 8AWG( 1- 1/32") 1.5" flat B No No At (CaAa) 210.00 - -0.500 .0.25 2 2 36.000 1.500 1.80 Cable Ladder 0.00 0.500 Rail Face C 1" lighting C No No Ar (Calks) 250.00- 1.000 0.5 1 1 24.000 1.000 2.00 conduit 0.00 0.000 LCF158- C No No Ar (CaAa) 195.00 - 0.000 0.4 6 6 0.890 2.010 0.92 50J(1-5/8") 160.00 0.500 LCF158- C No No Ar (CaAa) 160.00- 0.000 0.4 20 12 0.890 2.010 0.92 50J(1-5/8") 0.00 0.500 WR- C No No Ar (CaAa) 160.00- 2.000 0.43 9 4 0.774 0.774 0.59 VG86ST- 0.00 BRD(3/4) WR- C No -No- Ar (CaAa) 195.00- 2.000. 0.43 3 3 0.774 0.774 __ _0.59 -- VG86ST- 160.00 BRD(3/4) LDF2- C No No Ar (Calks) 160.00- 0.000 0.38 8 4 0.440 0.440 - 0.08 50(3/8") 0.00 LDF2- C No No Ar (CaAa) 195.00 - 0.000 0.38 4 4 0.440 0.440 0.08 50(3/8") 160.00 1.5" flat C No No Af (Calks) 250.00- 0.000 0.4 2 2 36.000 1.500 1.80 Cable Ladder 0.00 0.500 Rail Discrete Tower Loads r .. Weight Description Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert It it ft2 ft' K ft " ft Beacon B From Leg 0.00 0.000 250.00 No Ice 3.60 3.60 0.10 0.00 ' 0.00 Obstruction light A From Leg 1.00 0.000 125.00 No Ice 0.50 0.50 0.01 0.00 0.00 Obstruction light B From Leg 1.00 0.000 125.00 No Ice 0.50 0.50 0.01 0.00 0.00 Obstruction light C From Leg 1.00 0.000 125.00 No Ice 0.50 0.50 0.01 0.00 0.00 Lightning Rod 5/8x4' C From Leg 0.00 0.000 250.00 No Ice 0.25 0.25 0.03 0.00 2.00 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CCI BU No 813700 Project Number 37519-0281.002.8700, Order475132, Revision 4 Page 18 Description Weight Face Offset Offsets: Azimuth Placement CAAA C,k or Type Horz Adjustmen Front Side Leg Lateral t Vert ft it fR fF K ft ° it 932DG33T2A-M w/ Mount A From Leg 4.00 0.000 237.00 No Ice 5.91 3.22 0.05 Pipe 0.00 1.00 742 218 w/ Mount Pipe B From Leg 4.00 0.000 237.00 No Ice 4.10 3.00 0.04 0.00 1.00 950G65VTZE-M w/ Mount B From Leg 4.00 0.000 237.00 No Ice 4.23 4.20 0.03 Pipe 0.00' 1.00 95OG65VTZE-M w/ Mount C From Leg 4.00 0.000 237.00 No Ice 4.23 4.20 0.03 Pipe 0.00 1.00 Side Arm Mount [SO 305- C None 0.000 237.00 No Ice 2.64 2.64 0.09 3] (3) DB848HI05ESX w/ A From Leg 4.00 0.000 224.00 No Ice 7.43 10.49 0.06 Mount Pipe 0.00 1.00 (3) DBB78H120ESXw/ C From Leg 4.00 0.000 224.00 No Ice 11.70 8.16 0.05 Mount Pipe 0.00 1.00 Sector Mount ISM 409-1] A None 0.000 224.00 No Ice 8.76 11.22 0.34 Sector Mount ISM 409-11 C None 0.000 224.00 No Ice 8.76 11.22 0.34 SBNHH-1 D65C w/ Mount A From Leg 4.00 0.000 217.00 No Ice 5.56 4.47 0.08 Pipe 0.00 0.00 SBNHH-1 D65C w/ Mount B From Leg 4.00 0.000 217.00 No Ire 5.56 4.47 0.08 Pipe 0.00 0.00 SBNHH-1D65C w/ Mount C From Leg 4.00 0.000 217.00 No Ice 5.56 4.47 0.08 Pipe 0.00 0.00 (2) CMA-BDHH/6520/EO-B A From Leg 4.00 0.000 217.00 No Ice 9.05 3.58 0.06 0.00 0.00 (2) CMA-BDHH/6520/EO-B B From Leg 4.00 0.000 217.00 No Ice 9.05 3.58 0.06 0.00 0.00 (2) CMA-BDHH/6520/EO-B C From Leg 4.00 0.000 217.00 No Ice 9.05 3.58 0.06 0.00 0.00 FRIG A From Leg 4.00 0.000 217.00 No Ice 2.39 0.97 0.06 0.00 0.00 FRIG B From Leg 4.00 0.000 217.00 No Ice 2.39 0.97 0.06 0.00 0.00 FRIG C From Leg 4.00 0.000 217.00 No Ice 2.39 0.97 0.06 0.00 0.00 RNSNOC-7771-PF-48 A From Leg 4.00 0.000 217.00 No Ice 3.20 1.03 0.01 0.00 0.00 RNSNOC-7771-PF-48 C From Leg 4.00 0.000 217.00 No Ice 3.20 1.03 0.01 0.00 0.00 (2) FXFB A From Leg 4.00 0.000 217.00 No Ice 3.54 1.02 0.06 0.00 0.00 (2) FXFB B From Leg 4.00 0.000 217.00 No Ice 3.54 1.02 0.06 0.00 0.00 (2) FXFB C From Leg 4.00 0.000 217.00 No Ice 3.54 1.02 0.06 0.00 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No 813700 Project Number37519-0281.002.8700, Order47513Z Revision 4 Page 19 Weight Description Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert ft it ft2 fF K ft ° ft 0.00 Sector Mount [SM 404-3] C None 0.000 217.00 No Ice 20A7 20.47 0.92 TTTT65AP-1XR w/ Mount A From Leg 4.00 0.000 207.00 No Ice 6.98 4.47 0.05 Pipe 0.00 3.00 (2) RRUS 31 B25 A From Leg 4.00 0.000 207.00 No Ice 1.62 1.28 0.06 0.00 3.00 RRUS 82 W/SOLAR A From Leg 4.00 0.000 207.00 No Ice 2.98 1.43 0.06 SHIELD 0.00 3.00 RRUS-11 80OMHZ A From Leg 4.00 0.000 207.00, No Ice 2.52 1.30 0.05 0.00 3.00 (2) ACU-A20-N A From Leg 4.00 0.000 207.00 No Ice 0.07 0.12 0.00 0.00 3.00 APXV9ERR18-C-A20 w/ A From Leg 4.00 0.000 207.00 No Ice 8.26 7.47 0.09 Mount Pipe 0.00 3.00 HPA33RLS4AA-K1 w/ B From Leg 4.00 0.000 207.00 No Ice 7.47 4.93 0.07 Mount Pipe 0.00 3.00 .RRUS 311325 B. _From Leg 4.00 0.000 _ 207.00_ No Ire 1.62 1.28 _ 0.06 _ 0.00 3.00 RRUS 82 W/SOLAR B From Leg 4.00 0.000 207.00 No Ice 2.98 1.43 0.06 SHIELD 0.00 3.00 (2) RRUS-11 80OMHZ B From Leg 4.00 0.000 207.00 No Ice 2.52 1.30 0.05 0.00 3.00 HPA33R-CS4AA-K1 w/ C From Leg 4.00 0.000 207.00 No Ice 7.47 4.93 0.07 Mount Pipe 0.00 3.00 RRUS 82 W/SOLAR C From Leg 4.00 0.000 207.00 No Ice 2.98 1.43 0.06 SHIELD 0.00 3.00 ACU-A20-N C From Leg 4.00 0.000 207.00 No Ice 0.07 0.12 0.00 0.00 3.00 Sector Mount [SM 301-1] A From Leg 2.00 0.000 207.00 No Ice 15.43 10.89 0.43 0.00 0.00 Sector Mount [SM 301-1] B From Leg 2.00 0.000 207.00 No Ice 15.43 10.89 0.43 0.00 0.00 Sector Mount [SM 502-1] C From Leg 2.00 0.000 207.00 No Ice 15.35 14.00 0.56 0.00 0.00 (3) SBNHH-1 D85C w/ C From Leg 4.00 0.000 195.00 No Ice 5.56 4.47 0.08 Mount Pipe 0.00 5.00 RRUS 32 C From Leg 4.00 0.000 195.00 No Ice 2.86 1.78 0.06 0.00 5.00 RRUS 4449 85/1312 C From Leg 4.00 0.000 195.00 No Ice 1.97 1.41 0.07 0.00 5.00 RRUS 8843 13211366A C From Leg 4.00 0.000 195.00 No Ice 1.64 1.35 0.07 0.00 5.00 13064MO-18-13F C From Leg 4.00 0.000 195.00 No Ice 1.21 1.21 0.03 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No 813700 Project Number 37519-0281.002.8700, Order 475132, Revision 4 Page 20 Description Face Offset Onsets: Aamuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert It it ft ft, K it ' 5.00 PVFM12-3-3-96 Sector C From Leg 2.00 0.000 195.00 No Ice 15.35 14.00 0.56 Frame 0.00 0.00 ... .TBR."'• (3) DBB48H105ESX w/ B From Leg 4.00 0.000 178.00 No Ice 7.43 10.49 0.06 Mount Pipe 0.00 2.00 Sector Mount [SM 409-1] B None 0.000 178.00 No Ice 8.76 11.22 0.34 (2) DC6-4MO-18-8F B From Leg 4.00 0.000 160.00 No Ice 1.21 1.21 0.03 0.00 0.00 RRUS 32 A From Leg 4.00 0.000 160.00 No Ice 2.86 1.78 0.06 0.00 0.00 RRUS 4449 B5112112 A From Leg 4.00 0.000 160.00 No Ice 1.97 1.41 0.07 0.00 0.00 RRUS 8843 B2/B66A A From Leg 4.00 0.000 160.00 No Ice 1.64 1.35 0.07 0.00 0.00 (3) 80010966K w/ Mount A From Leg 4.00 0.000 160.00 No Ice 17.60 9.64 0.15 Pipe 0.00 0.00 RRUS 32 B From Leg 4.00 0.000 160.00 No Ice 2.86 1.78 0.06 0.00 0.00 RRUS 4449 B5/B12 B From Leg 4.00 0.000 160.00 No Ice 1.97 1.41 0.07 0.00 0.00 RRUS 8843 B2/B66A B From Leg 4.00 0.000 160.00 No Ice 1.64 1.35 0.07 0.00 0.00 (3) 80010966K w/ Mount B From Leg 4.00 0.000 160.00 No Ice 17.60 9.64 0.15 Pipe 0.00 0.00 DC6-48-60-18-BF A From Leg 4.00 0.000 160.00 No Ice 1.21 1.21 0.03 0.00 0.00 PVFM12-3-3-96 Sector A From Leg 1.00 0.000 160.00 No Ice 13.12 10.18 0.54 Frame 0.00 0.00 PVFM12-3-3-96 Sector B From Leg 1.00 0.000 160.00 No Ice 13.12 10.18 0.54 Frame 0.00 0.00 ...."'TBR...... Pipe Mount [PM 601-1] A From Leg 0.00 0.000 128.00 No Ice 3.00 0.90 0.07 0.00 0.00 Pipe Mount [PM 601-1] C From Leg 0.50 0.000 120.00 No Ice 3.00 0.90 0.07 0.00 0.00 FIBEAIR 1500HP C From Leg 1.00 0.000 120.00 No Ice 0.97 1.74 0.02 0.00 0.00 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No,813700 Project Number37519-0281.002.8700, Order47513Z Revision 4 Page 21 Dishes Weight Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture or Type Type Horz Adjustment Beam Diameter Area Leg Lateral Width Vert ft It ft it, K SPD2-5.8 A Paraboloid From 1.00 -70.000 128.00 2.00 No Ice 3.14 0.02 w/Radome Leg 0.00 0.00 HPX6-59-P3A/K C Paraboloid From 1.00 -34.000 120.00 6A6 No Ice 32.76 0.32 w/Shroud (HP) Leg 0.00 0.00 Load Combinations _ . Comb. Description - No. 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg - No Ice - 3 0.9 Dead+1.0 Wind 0 deg - No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice 6 1.2 Dead+1.0 Wind 60 deg - No Ice 7 0.9 Dead+1.0 Wind 60 deg - No Ice 8 1.2 Dead+1.0 Wind 90 deg - No Ice 9 0.9 Dead+1.0 Wind -90deg - No Ice- - - - - -- - --- -- 10 1.2 Dead+1.0 Wind 120 deg - No Ice 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice 14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice - 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg - Service 28 Dead+Wind 60 deg - Service 29 Dead+Wind 90 deg - Service 30 Dead+Wind 120 deg - Service 31 Dead+Wind 150 deg - Service 32 Dead+Wind 180 deg - Service 33 Dead+Wind 210 deg - Service 34 Dead+Wind 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+Wind 330 deg - Service Maximum'. Tower Deflections;= Service Wind section Elevation Horz Gov. Tilt Twist No. Deflection Load it in Comb. ° T1 250 - 240 3.69 30 0.111 0.030 . T2 240 - 220 3.46 30 0.111 0.030 T3 220 - 200 2.99 30 0.109 0.029 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 Section Elevation Hor7 Gov. Tilt Twist No. Deflection Load ft in Comb. ° T4 200 - 186.667 2.53 30 0.105 0.028 T5 186.667 - 180 2.23 26 0.100 0.026 T6 180 - 160 2.09 26 0.098 0.025 T7 160 - 140 1.68 26 0.088 0.022 T8 140 - 120 1.31 26 0.077 0.021 T9 120 - 100 0.98 26 0.066 0.018 T10 100 - 80 0.69 26 0.055 0.014 T11 80 - 60 0.46 26 0.044 0.012 T12 60-40 0.28 26 0.032 0.009 T13 40 - 20 0.14 26 0.021 0.005 T14 20 - 0 0.04 26 0.010 0.003 May 1, 2019 CCI BU No 613700 Page 22 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in oft 250.00 Beacon 30 3.69 0.111 0.030 Inf 237.00 932DG33T2A-M w/ Mount Pipe 30 3.39 0.111 0.030 Inf 224.00 (3) D88481-1105ESX w/ Mount 30 3.08 0.110 0.029 Inf Pipe 217.00 SBNHH-1 D65C w/Mount Pipe 30 2.92 0.109 0.029 Inf 207.00 TTTT65AP-1 XR w/ Mount Pipe 30 2.69 0.107 0.029 628701 195.00 (3) SBNHH-1 D85C w/ Mount 30 2.41 0.103 0.027 134902 Pipe 178.00 (3) DB848H105ESXw/Mount 26 2.05 0.097 0.025 313356 Pipe 160.00 (2) DC648-60-18-8F 26 1.68 0.088 0.022 126694 128.00 SPD2-5.8' 26 1.10 0.070 0.019 116344 125.00 Obstruction light 26 1.06 0.069 0.019 126871 120.00 HPX6-59-P3AIK 26 0.98 0.066 0.018 137872 Maximumlower Deflections - Design Wind Section Elevation Hors Gov. Tilt Twist No. Deflection Load ft- in Comb. ° T1 250 - 240 24.28 10 0.731 0.193 T2 240 - 220 22.74 10 0.730 0.193 T3 220 - 200 19.66 10 0.719 0.191 T4 200 - 186.667 16.60 10 0.688 0.182 T5 186.667 - 180 14.62 10 0.660 0.167 T6 180 -160 13.69 10 0.642 0.161 T7 160 -140 10.99 10 0.578 0.142 T8 140 - 120 8.52 10 0.507 0.133 T9 120 - 100 6.38 2 0.433 0.118 T10 100 - 80 4.50 2 0.359 0.093 T11 80 - 60 2.99 2 0.286 0.075 T12 60-40 1.80 2 0.208 0.057 T13 40 - 20 0.89 2 0.135 0.036 T14 20 - 0 0.28 2 0.065 0.018 Critical Deflections and'Radiu§ of Curvature .- Desi n Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft tnxTower Report - version 8.0.5.0 n 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 23 Elevation R Appurtenance Gov. Load Comb. Deflection in Tilt Twist Radius of Curvature it 250.00 Beacon 10 24.28 0.731 0.193 751640 237.00 932DG33T2A-M w/ Mount Pipe 10 22.28 0.729 0.193 467264 224.00 (3) DB848H105ESX w/ Mount 10 20.28 0.722 0.191 525820 Pipe 217.00 SBNHH-1D65C w/ Mount Pipe 10 19.20 0.715 0.190 222580 207.00 TTTT65AP-1XR w/ Mount Pipe 10 17.67 0.700 0.187 99376 195.00 (3)SBNHH-1 D85C w/Mount 10 15.85 0.679 0.176 21479 Pipe 178.00 (3) DB8481-1105ESX w/ Mount 10 13.41 0.636 0.160 50996 Pipe 160.00 (2) DC6-48-60-18-BF 10 10.99 0.578 0.142 19579 128.00 SPD25.8 2 7.20 0.463 0.126 17623 125.00 Obstruction light 2 6.89 0.452 0.123 19153 120.00 HPX6-59-P3A/K 2 6.38 0.433 0.118 20947 Bolt Design Data Criteria Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable No. Type Grade Of Load Load Load Ratio ft in Bolts per Bolt per Bolt Allowable K K T1 250 Leg A325N 0.625 4 0.29 20.34 0.014 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 0.38 6.79 0.057 ✓ 1.05 Member Block _ Shear__ Top Girt A325N 0.625 1 0.10 7.88 ✓ 1.05 Member Block 0.013 Shear T2 240 Leg A325N 0.875 6 2.38 41.56 0.057 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 2.20 8.31 0.265' ✓ 1.05 Member Block Shear T3 220 Leg A325N 1.000 6 9.47 54.52 0.174 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 4.82 11.09 0.435 ✓ 1.05 Member Block Shear T4 200 Diagonal A325N 0.625 2 5.75 11.09 ✓ 1.05 Member Block 0.519 Shear T5 186.667 Leg A325N 1.250 6 19.07 87.22 0.219 ✓� 1.05 Bolt Tension Diagonal A325N 0.625 .' 2 6.00 22.17 0.271 V 1.05 Member Block Shear T6 180 Leg A325N 1.250 6 28.09 87.22 0322 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 7.20 15.61 0.461 ✓ 1.05 Member Block Shear Secondary A325N 0.625 1 3.44 9.91 ✓ 1.05 Member Block Horizontal 0.347 Shear T7 160 Leg A325N 1.250 6 39.27 8722 0.450 ✓� 1.05 Bolt Tension Diagonal A325N 0.625 2 8.91 15.61 1.05 Member Block 0.571 Y Shear Secondary A325N 0.625 1 4.69 10.93 ✓ 1.05 Member Block Horizontal 0429 Shear T8 140 Leg A325N 1.375 6 50.72 103.94 0.488 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 10.19 16.63 0.613 ✓ 1.05 Member Block Shear Secondary A325N 0.625 1 6.02 10.93 ✓ 1.05 Member Block Horizontal 0.551 Shear T9 120 Leg A325N 1.500 6 62.28 126.47 0492 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 12.36 16.63 ✓ 1.05 Member Block 0.743 Shear Secondary A325N 0.625 1 7.39 13.81 1.05 Bolt Shear 0.535 Honzontal T10 100 Leg A325N 1.500 6 70.36 126.47 0.556 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 17.99 27.61 0.651 ✓ 1.05 Bolt Shear tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision May 1, 2019 CC/ BU No 813700 Page 24 Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable Criteria No. Type Grade Of Load Load Load Ratio ft in Bolts per Bolt per Bolt Allowable T11 T12 T13 T14 0.625 1 8.37 19.83 0.422 V 80 Leg A325N 1.500 6 81.77 126.47 0.647 V/ Diagonal A325N 0.625 2 17.74 27.61 0.643 Horizontal A325N 0.625 1 9.77 19.83 0.493 60 Leg A325N 1.750 6 92.44 170.95 0.541 YI Diagonal A325N 0.625 2 17.61 22.17 0.794 V� Horizontal A325N 0.625 1 11.06 19.83 0.558 40 Leg A325N 1.750 6 103.23 170.95 0.604 Vr Diagonal A325N 0.625 2 19.12 27.61 0.692 Horizontal A325N 0.625 1 12.42 21.87 0.568 20 Diagonal A325N 0.625 2 20.14 27.61 0.729 Horizontal A325N 0.625 1 13.75 21.87 0.629 'Compression Checks . Leg Design Data (Compression), 1.05 1.05 1.05 1.05 1.05 1.05 1.05 1.05 1.05 1.05 1.05 1.05 Member Block Shear Bolt Tension Bolt Shear Member Block Shear Bolt Tension Member Block Shear Member Block Shear Bolt Tension Bolt Shear Member Block Shear Bolt Shear Member Block Shear Section No. Elevation It Size L it L. ft KI1r A irtz P. K op" K Ratio P 0P„ T1 250 - 240 2" solid 10.00 5.00 120.0 3.142 -1.94 49.29 0.0371 K=1.00 V T2 240 - 220 3" solid 20.03 6.68 106.8 7.069 -18.51 138.05 0.1341 K=1.00 T3 220-200 31/2'solid 20.03 6.68 91.6 9.621 -68.39 234.48 0.2921 K=1.00 `/" T4 200 - 186.667 4" solid 13.36 6.68 80.1 12.566 -110.81 353.60 0.3131 K=1.00 V T5 186.667 - 180 4" solid 6.68 6.68 80.1 12.566 -132.10 353.60 0.3741 K=1.00 V T6 180 - 160 4" solid 20.03 5.19 62.3 12.566 -193.01 425.67 0.4531 K=1.00 V/ T7 160 - 140 4 1/4" solid 20.03 5.17 58.4 14.186 -270.24 497.53 0.6431 K=1.00 V T8 140 - 120 4 1/2" solid 20.03 5.15 54.9 15.904 347.23 573.92 0.6051 K=1.00 V T9 120 - 100 4 3/4" solid 20.03 5.14 51.9 17.721 -425.94 654.83 0.6501 K=1.00 T10 100 - 80 5" solid 20.03 5.01 48.1 19.635 -482.62 746.17 0.6471 K=1.00 V T11 80 - 60 5" solid 20.03 5.01 48.1 19.635 -563.25 746.17 0.755 1 K=1.00 t/ T12 60-40 51/4"solid 20.03 5.01 45.8 21.647 -637.60 835.68 0.7631 K=1.00 V T13 40-20 51/2"solid 20.03 5.01 43.7 23.758 -716.41 929.74 0.7711 K=1.00 V T14 20 - 0 5 3/4" solid 20.03 5.01 41.8 25.967 -792.65 1028.33 0.7711 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 25 Section Elevation Size L L„ KUr A P„ op Ratio No. P. it it it in' K K op„ K=1.00 `/ 1 P � / op, controls Dia` onal-Desi`n-D'ata Comb ression ,,-,,y Ratio Section Elevation Size L L„ Mr A P„ OP„ No. P. it tt It in2 K K OP„ T1 250 - 240 L 2 x 2 x 3/16 7.81 3.80 115.6 0.715 -0.88 14.92 0.059' T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 240 - 220 220 - 200 200-186.667 186.667 - 180 180 - 160 160 - 140 140 - 120 120 -100 100-80 80-60 60-40 40-20 20-0 1 P„ / op, controls L3x3x3/16 L3x3x1/4 L3x3x1/4 2L 3 x 3 x 1/4(3/8) 2L'a' > 38.495 in - 83 2L 2.5 x 2.5 x 3/16 (1/2) 2L 2.5 x 2.5 x 3/16 (1/2) 2L 3 x 3 x 3116(1/2) 2L 3 x 3 x 3116(1/2) 2L 3 x 3 x 6116(1/2) 2L 3 x 3 x 5116(1/2) 2L 3 x 3 x 1/4(1/2) 2L 3 x 3 x 5116(1/2) 2L 3 x 3 x 5116(112) 10.16 5.14 11.74 5.90 12.86 6A3 13.44 6.72 16.80 8.51 18.45 9.31 20.16 10.15 21.92 11.02 14.87 14.59 15.62 15.35 16.40 8.20 17.21 8.60 18.03 9.02 K=1.00 103.4 1.090 4.67 K=1.00 119.5 1.440 -10.11 K=1.00 130.4 1.440 -11.76 K=1.00 89.6 2.880 -12.24 K=1.00 131.1 1.805 -15.38 K=1.00 143.6 1.805 -18.38 K=1.00 129.7 2.180 -21.09 K=1.00 140.7 2.180 -24.97 K=1.00 138.3 3.555 -35.98 K=1.00 145.9 3.555 35A9 K=1.00 105.8 2.875 38.65 K=1.00 112.0 3.555 38.24 K=1.00 117.4 3.555 40.28 K=1.00 25.59 0.1821 II/ 28.55 0.354' 24.25 0.4851 76.23 0.161 ' V 30.03 0.5121 25.06 0.7331 36.03 0.585' t/ 31.50 0.793' 52.65 0.683' 47.31 0.750' 67.08 0.576' 77.48 0.494' 72.53 0.5555' Y ` Horizontal Design Data Com ression Ratio Section Elevation Size L L. KI1r A P. OP„ No. P If @ R LF K K mPn T10 100 - 80 2L 2.5 x 2.5 x 3116 (1/2) 21.00 10.29 158.7 1.805 -8.37 20.51 0.4081 T11 80-60 2L 2.5 x 2.5 x 3/16 (1/2) T12 60-40 2L 2.5 x 2.5 x 3116(1/2) 2L'a' > 70.285 in - 262 T13 40-20 2L 3 x 3 x 3116(1/2) tnxTower Report - version 8.0.6.0 K=1.00 V 23.00 11.29 174.1 1.805 -9.77 17.04 0.573' K=1.00 V 25.00 12.28 189.4 1.805 -11.08 14.40 0.768' K=1.00 t/ 27.00 13.27 170.2 2.180 -12.42 21.06 0.590, 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CCI BU No 813700 Page 26 Section Elevation Size L L KI1r A P. OP„ Ratio No. P it If If in2 K K 1hp- 2L'a' > 75.820 in - 326 T14 20-0 2L 3 x 3 x 3116 (1/2) 2L'a' > 81.474 in - 383 1 P„ / opn controls 29.00 14.26 183.3 2.180 -13.75 18.23 0.754' K=1.00 V Sedondary Horizontal Design Data Com ression ' ' Ratio Section Elevation Size L L„ KI1r A P. OP„ No. P it ft ft in2 K K op, T6 180 - 160 L 2.5 x 2.5 x 3/16 13.48 6.57 159A 0.902 -3.44 10.16 0.338' K=1.00 t/ T7 160 -140 L 3 x 3 x 3/16 15.48 7.56 152.3 1.090 -4.69 13.45 0.3481 K=1.00 1/ T8 140 - 120 L 3 x 3 x 3/16 17.49 8.56 172.3 1.090 -6.02 10.51 0.573' K=1.00 V T9 120 - 100 L 3 x 3 x 1/4 19.49 9.55 193.5 1.440 -7.39 11.01 0.6711 K=1.00 V ' P � / op. controls To Girt Desi n Data Com ression Ratio Section Elevation Size L L„ KI(r A P„ OP„ No. P It ft It in2 K K OP„ T1 250 - 240 L 2 x 2 x 3/l6 6.00 5.83 177.7 0.715 -0.12 6.48 0.019, K=1.00 1 P„ / op, controls Redundant Horizontal 1 Design Data Com ression Section. No. Elevation it Size L It L. it KI(r A in2 P. K OP„ K Ratio P. OP„ T10 100 - 80 2L 2 x 2 x 3/16 (1/2) 5.25 5.D4 - 98.0 1.430 -8.37 35.81 0.234' K=1.00 2L'a' > 28.945 in - 177 T11 80 - 60 2L 2 x 2 x 3/16 (112) 5.75 5.54 107.7 1.430 -9.77 32.67 0.299' K=1.00 V/ 2L'a' > 31.815 in - 222 T12 60 - 40 2L 2 x 2 x 3116 (112) 6.25 6.03 117.2 1.430 -11.06 29.22 0.378' K=1.00 6/ 2L la' > 34.626 in - 267 T13 40 - 20 2L 2 x 2 x 3116 (1/2) 6.75 6.52 126.8 1.430 -12.42 25.47 0.488' K=1.00 2L'a' > 37.437 in - 331 T14 20-0 2L 2 x 2 x 3116 (1/2) 7.25 7.01 136.3 1.430 -13.75 22.03 0.624' tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 27 Section Elevation Size L L. MY A P. op„ Ratio No. P ft ft It inz K K OP„ K=1.00 r/ 2L'a' > 40.247 in - 388 1 P � / op. controls Redundant D a onaf. 1 Desi nbD to Coni ression Ratio Section Elevation Size L L„ KI1r A P. QP„ No. P It It ft in K K OP„ T10 100 - 80 2L 2 x 2 x 3/16 (1/2) 7.43 7.14 138.8 1.430 -5.93 21.24 0.279' K=1.00 0/ 2L'a'>40.991 in-201 T11 80 - 60 _ 2L 2 x 2 x 3116 (1/2) 7.81 7.53 146.4 1.430 -6.64 19.10 0.3471 K=1.00 2L'a'>43.231 in-246 T12 60 - 40 2L 2 x 2 x 3/16 (1/2) 8.20 7.92 153.9 1.430 -7.26 17.28 0.4201 K=1.00 2L'a' > 45.453 in - 297 T13 40 - 20 2L 2 x 2 x 3116 (1/2) 8.60 8.31 161.6 1.430 -7.92 15.66 0.505 1 K=1.00 �I 2L'a' > 47.734 in - 360 T14- 20 = 0 2L 2.5x 2.5 x 3116 (112) 9.02 8.72 136.0 1.805 --8.55 27.27 - -0.313' K=1.00 21-'a' > 49.908 in - 417 1 P � / QP„ controls Redundant Hip. 1 Desi n Data (Coin Cession ` _ . ` Ratio Section Elevation Size L L. KI1r A P. ¢P No. P It ft It W K K OP„ T12 60 - 40 L 2.5 x 2.5 x 3/16 6.25 6.25 151.5 0.902 -0.10 11.25 0.009' T13 40-20 L2.5 x2.5 x3/16 T14 20-0 L2.5 x2.5 x3/16 1 P„ / op, controls K=1.00 V 6.75 6.75 163.6 0.902 -0.09 9.64 0.0101 K=1.00 tf 7.25 7.25 175.8 0.902 -0.09 8.36 0.0111 K=1.00 9% Redundant Hi'° '.Dia oval 1 Desi n Data (Compression) Ratio Section Elevation Size L L. KI1r A P. OP„ No. P it ft It irP K K 4P„ T12 60 - 40 L 2.5 x 2.5 x 3116 11.80 11.80 286.0 0.902 -0.14 3.16 0.0451 K=1.00 KUR > 250 (C) - 315 T13 40 - 20 L 2.5 x 2.5 x 3/16 12.59 12.59 305.1 0.902 -0.12 2.77 0.043' K=1.00 `f tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CCI BU No 813700 Page 28 Section Elevation Size L L„ IGr A P„ OP„ Ratio No. P. ft it it in2 K K OP, KUR > 250 (C) - 372 T14 20 - 0 L 2.5 x 2.5 x 3116 13.38 13.38 324.5 0.902 -0.12 2.46 0.0491 K=1.00 KUR > 250 (C) - 429 1 P u f ¢P„ controls inner Bracing Desi 'n Data (Compression) Ratio Section Elevation Size L L. KI1r A P. OP„ No. P. It If ft in2 K K OP" T10 100 - 80 2L 2 x 2 x 3/16 (3/8) 10.50 10.50 204.2 1.430 -0.03 9.81 0.003 1 K=1.00 V T11 80- 60 2L 2 x 2 x 3/16 (3/8) 11.50 11.50 223.7 1.430 -0.03 8.18 0.004' K=1.00 V T12 60 - 40 2L 2 x 2 x 3/16 (3/8) 12.50 12.50 243.1 1.430 -0.06 6.93 0.009 1 K=1.00 V T13 40 - 20 2L 2.5 x 2.5 x 3/16 (3/8) 13.50 13.50 208.2 1.800 -0.08 11.88 0.0071 K=1.00 V T14 20 - 0 2L 2.5 x 2.5 x 3116 (3/8) 14.50 14.50 223.6 1.800 -0.04 10.30 0.041 K=1.00 V 1 P" f QP" Controls Tension Checks °Le Desi "n Data Tension Section Elevation Size L L„ KI1r A P„ OP„ Ratio No. P. it it ft in2 K K 6p- T2 240 - 220 3" solid 20.03 6.68 106.8 7.069 14.30 318.09 0.0451 T3 220 - 200 3 1/2" solid 20.03 6.68 91.6 9.621 56.85• 432.95 0.1331 1 V T4 200 - 186.667 4" solid 13.36 6.68 80.1 12.566 95.17 565.49 0.1681 T5 IB6.667-180 4" Solid 6.68 6.68 80.1 12.566 114.43 565.49 0.2021 T6 180 - 160 4" solid 20.03 4.82 57.9 12.566 168.75 565.49 0.2981 T7 160 - 140 4 1/4" solid 20.03 4.85 54.7 14.186 235.84 638.38 0.3691 T8 140 - 120 4 1/2" solid 20.03 4.87 51.9 15.904 304.58 715.69 0.42`61 Y T9 120 - 100 4 3/4" solid 20.03 4.88 49.3 17.721 374.05 797.42 0.4691 T10 100 - 80 5" solid 20.03 5.01 48.1 19.636 423.41 883.57 0.4791 V tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 29 Section No. Elevation ft Size L ft L. ft Kl/r A in2 P" K �P" K Ratio P. OP„ T11 80 - 60 - 5" solid 20.03 5.01 48.1 19.635 491.75 883.57 0.5571 V T12 60-40 5IM'solid 20.03 5.01 45.8 21.647 555.40 974.14 0.5701 V T13 40-20 51/2"solid 20.03 5.01 43.7 23.758 620.80 1069.12 0.5811 4� T14 20.0 5 3/4" solid 20.03 5.01 41.8 25.967 680.24 1168.63 0.5821 tr 1 P„ / op, controls Dia6onal Design. Data' ;Tension Ratio Section Elevation Size L L„ KI1r A P. op. No. P. It ft ft in2 K K 413" T1 250 - 240 L 2 x 2 x 3/16 7.81 3.80 73.8 0.431 0.77 18.74 0.041 1 T2 240 - 220 L 3 x 3 x 3116 10.16 5.14 65.6 0.712 4.41 30.97 0.1421 T3 220 - 200 L 3 x 3 x 1/4 11.74 5.90 76.1 0.939 9.64 40.86 0.236 1 • T4 200 - 186.667 L 3 x 3 x 1/4 12.86 6.43 83.0 0.939 11.51 40.88 0.2821 T5 186.667 - 180 2L 3 x 3 x 1/4 (3/8) 13.44 6.72 86.7 1.879 12.01 81.73 0.1471 2L'a' > 38.495 in - 83 T6 180 - 160 2L 2.5 x 2.5 x 3/16 (1/2) 16.80 8.51 131.1 1.143 14.39 49.70 0.2901 T7 160 - 140 2L 2.5 x 2.5 x 3/16 (112) 18.45 9.31 143.6 1.143 17.82 49.70 0.3581 T8 140 - 120 2L 3 x 3 x 3/16 (1/2) 20.16 10.15 129.7 1 A24 20.38 61.94 0.329 1 . .y T9 120 - 100 2L 3 x 3 x 3/16 (1/2) 21.92 11.02 140.7 1.424 24.72 61.94 0.399 1 T10 100 - 80 2L 3 x 3 x 5/16 (1/2) 14.87 14.59 121.0 2.314 32.97 100.68 0.3271 T11 80 - 60 2L 3 x 3 x 5116 (1/2) 14.87 14.60 121.1 2.314 34.31 100.68 0.3411 T12 60 - 40 2L 3 x 3 x 1/4 (1/2) 16.40 8.20 105.8 1.875 35.22 81.56 0.4321 T13 40 - 20 2L 3 x 3 x 5/16 (1/2) 16.40 8.20 106.8 2.314 36.71 100.68 0.3651 T14 20 - 0 2L 3 x 3 x 5116 (112) 17.21 8.60 112.0 2.314 36.53 100.68 0.363 1 V 1 P" / op, controls Horizontal-Desi n Data` Tension , . Ratio Section Elevation Size L L. K11r A P. OP" No. P. It ft it in2 K K 4p" T10 100 - 80 2L 2.5 x 2.5 x 3116 (112) 21.00 10.29 158.7 1.143 8.37 49.70 0.1681 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC1 BU No 813700 Page 30 Section Elevation Size L L. Mr A P. Wn Ratio No. P ft It it in, K K mp- T11 80 - 60 T12 60 - 40 T13 40-20 T14 20-0 1 P, / op. controls 2L 2.5 x 2.5 x 3/16 (1/2) 23.00 11.29 174.1 1.143 9.77 49.70 0.1971 V 2L 2.5 x 2.5 x 3116 (1/2) 25.00 12.28 189.4 1.143 11.06 49.70 0.2221 2L'a' > 70.285 in - 269 2L 3 x 3 x 3116 (1/2) 27.00 13.27 169.5 1.424 12.42 61.94 0.201 2L'a' > 75.820 in - 326 ' 2L 3 x 3 x 3/16 (112) 29.00 14.26 182.2 1.424 13.75 61.94 0.2221 2L 'a' > 81.474 in - 383 Secondary Horizontal Desi n Data Tension Section Elevation Size L L„ KI1r A P. OP„ Ratio No. P 1t it it in' K K AP_ T6 180 - 160 L 2.5 x 2.5 x 3116 13.48 6.57 202.8 0.571 3.44 24.84 0.138' le T7 160 - 140 L 3 x 3 x 3/16 15.48 7.56 193.4 0.712 4.69 30.97 0.151, Y T8 140 - 120 L 3 x 3 x 3116 17.49 8.56 218.7 0.712 6.02 30.97 0.194' T9 120 - 100 L 3 x 3 x 1/4 19.49 9.55 246.3 0.939 7.39 40.86 0.181 1 1 P u / op, controls Top Girt Design Data Tension Section Elevation Size L L„ KI/r A P„ ¢P„ Ratio No. P. ft ft 1t in' K K OP„ T1 250 - 240 L 2 x 2 x 3/16 6.00 5.83 1 1 P u / @P„ controls Redundant Horizontal 1 Design Data Tension Ratio Section Elevation Size L L„ K11r A P. OP„ No. P If It ft in2 K K op� T10 100 - 80 2L 2 x 2 x 3116 (1/2) 5.25 5.04 98.0 1.430 8.37 46.32 0.181 1 2L'a' > 28.945 in - 177 T11 80 - 60 2L 2 x 2 x 3116 (1/2) 5.75 5.54 107.7 1.430 . 9.77 46.32 0.2111 V tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 31 Section Elevation Size L L„ KOr A P„ op. Ratio No. P. it ft It In2 K K op„ 2L'a'>31.815 in-222 T12 60 - 40 2L 2 x 2 x 3/16 (1/2) 6.25 6.03 117.2 1.430 11.06 46.32 0.239' 2L'a' > 34.626 in - 267 T13 40 - 20 2L 2 x 2 x 3/16 (112) 6.75 6.52 126.8 1.430 12.42 46.32 0.2681 2L'a' > 37.437 in - 331 T14 20 - 0 2L 2 x 2 x 3/16 (112) 7.25 7.01 136.3 1.430 13.75 46.32 0.2971 2L'a' > 40.247 in - 394 1 P � / op, controls Redundant Dia " onal 1 Design Data Tension ' . Ratio Section Elevation Size L L. KI/r A P. op. No. P ft ft it io2 K K OP„ T10 100 - 80 2L 2 x 2 x 3116 (1/2) 7.43 7.14 138.8 1.430 5.93 46.32 - 0.128' 2L'a' > 40.991 in - 201 T11 80 - 60 2L 2 x 2 x 3/16 (1/2) 7.81 7.53 146.4 1.430 6.64 46.32 0.143' 2L'a' > 43.231 in - 246 T12 60 - 40 2L 2 x 2 x 3116 (1/2) 8.20 7.92 153.9 1.430 7.26 46.32 0.157' 2L'a' > 45.453 in - 300 T13 40 - 20 2L 2 x 2 x 3116 (1/2) 8.60 8.31 161.6 1.430 7.92 46.32 0.1711 Y 2L'a' > 47.734 in - 365 T14 20 - 0 2L 2.5 x 2.5 x 3/16 (1/2) 9.02 8.72 134.5 1.805 8.55 58.47 0.146' 2L'a' > 49.908 in - 417 1 P„ / ¢P„ Controls Redundant Hi " 1 Desi n Data (Tension)` Section Elevation Size L L. KUr A P„ �P„ Ratio No. P. It it It in K K a P_ T12 60 - 40 L 2.5 x 2.5 x 3116 6.25 6.25 96.4 0.902 0.06 29.22 0.002' - T13 40 - 20 L 2.5 x 2.5 x 3116 6.75 6.75 104.1 0.902 0.05 29.22 0.002' T14 20 - 0 L 2.5 x 2.5 x 3/16 7.25 7.25 111.8 0.902 0.04 29.22 0.002' 1 P„ / op, controls Redundant Hip Dia onal- 1 Desi n.Data Tension tnxTower Report - version 8.0.6.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 32 Section Elevation Size L L„ KI1r A P. Ratio No. P T12 60-40 L2.5 x2.5 x3116 T13 40-20 L2.6 x2.5 x3/16 T14 20-0 L2.5 x2.5 x 3116 1 P u / ¢P„ controls in ir.2 K K 0.902 0.15 29.22 12.85 12.85 198.2 0.902 0.13 29.22 13.65 13.65 210.6 0.902 0.12 29.22 Inner Bracing Design Data Tension 0.005 ' V 0.004' 0.004' Section Elevation Size L L. KI1r A P„ ¢P„ Ratio No. A, in2 K K Tl l 80 - 60 2L 2 x 2 x 3/16 (3/8) 11.50 11.50 223.7 1.430 0.00 46.33 0.000' V T12 60 - 40 2L 2 x 2 x 3/16 (3/8) 12.50 12.60 243.1 1.430 0.03 46.33 0.001, T13 40 - 20 2L 2.5 x 2.5 x 3116 (318) 13.50 13.50 208.2 1.800 0.02 58.32 0.000' V T14 20 - 0 2L 2.5 x 2.5 x 3/16 (318) 14.50 14.50 223.6 1.800 0.02 58.32 0.000, Ili 1 P„ / ¢P, controls Section Capacity Table Section No. Elevation It Component Type Size Critical Element P K opa . K % Capacity Pass Fail T1 250 - 240 Leg 2" solid 2 -1.84 51.75 3.6 Pass T2 240 - 220 Leg 3" solid 20 -18.51 144.96 12.8 Pass T3 220-200 Leg 31/2"solid 41 -68.39 246.21 27.8 Pass T4 200 - 186.667 Leg 4" solid 61 -110.81 371.28 29.8 Pass T5 186.667 - 180 Leg 4" solid 76 -132.10 371.28 35.6 Pass T6 180 - 160 Leg 4" solid 86 -193.01 446.95 43.2 Pass T7 160-140 Leg 4lW'solid 107 -270.24 522.41 51.7 Pass T8 140 - 120 Leg 4 1/2" solid 128 -347.23 602.61 57.6 Pass T9 120 - 100 Leg 4 3/4" solid 149 -425.94 687.57 61.9 Pass T10 100 - 80 Leg 5" solid 170 -482.62 783.48 61.6 Pass Tl l 80 - 60 Leg 5" solid 215 -563.25 783.48 71.9 Pass T12 60 - 40 Leg 5 1/4" solid 260 -637.60 877.46 72.7 Pass T13 40 - 20 Leg 5 1/2" solid 318 -716.41 976.23 73.4 Pass T14 20 - 0 Leg 5 3/4" solid 375 -792.65 1079.75 73.4 Pass T1 250 - 240 Diagonal L 2 x 2 x 3116 7 -0.88 15.66 5.6 Pass T2 240 - 220 Diagonal L 3 x 3 x 3116 27 -4.67 26.87 17.4 Pass 25.2 (b) T3 220 - 200 Diagonal L 3 x 3 x 1/4 48 -10.11 29.97 33.7 Pass 41.4 (b) T4 200 - 186.667 Diagonal L 3 x 3 x 1/4 68 -11.76 25.46 46.2 Pass 49A (b) T5 186.667 - 180 Diagonal 2L 3 x 3 x 1/4 (3/8) 83 -12.24 80.04 15.3 Pass 25.8 (b) T6 180 - 160 Diagonal 2L 2.5 x 2.5 x 31% (112) 92 -15.38 31.54 48.8 Pass T7 160 - 140 Diagonal 2L 2.5 x 2.5 x 3/16 (1/2) ill -18.38 26.31 69.8 Pass T8 140 - 120 Diagonal 2L 3 x 3 x 3/16 (1/2) 134 -21.09 37.83 55.8 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 May 1, 2019 ' CC/ BU No 813700 Page 33 No. it Type Element K K Capacity Fail 58.4 (b) T9 120 - 100 Diagonal 21. 3 x 3 x 3/16 (1/2) 155 -24.97 33.07 75.5 Pass T10 100 - 80 Diagonal 21. 3 x 3 x 5/16 (112) 187 -35.98 55.28 65.1 Pass T11 80 - 60 Diagonal 21. 3 x 3 x 5/16 (1/2) 232 -35.49 49.67 71.4 Pass T12 60 -40 Diagonal 2L 3 x 3 x 1/4 (1/2) 279 -38.65 70.43 54.9 Pass 75.6 (b) T13 40 - 20 Diagonal 21. 3 x 3 x 5/16 (1/2) 336 -38.24 81.35 47.0 Pass 66.0 (b) T14 20 - 0 Diagonal 2L 3 x 3 x 5/16 (1/2) 393 -40.28 76.16 52.9 Pass 69.5 (b) T10 100 - 80 Horizontal 2L 2.5 x 2.5 x 3116 (1/2) 172 -8.37 21.54 38.9 Pass 40.2 (b) T11 80 - 60 Horizontal 2L 2.5 x 2.5 x 3116 (1/2) 217 -9.77 17.89 54.6 Pass T12 60 - 40 Horizontal 21. 2.5 x 2.5 x 3/16 (1/2) 262 -11.06 15.12 73.1 Pass T13 40 - 20 Horizontal 21. 3 x 3 x 3/16 (1/2) 326 -12.42 22.12 56.2 Pass T14 20 - 0 Horizontal 21. 3 x 3 x 3/16 (1/2) 392 -13.75 19.14 71.8 Pass T6 180 - 160 Secondary L 2.5 x 2.5 x 3/16 94 -3.44 10.67 32.2 Pass Horizontal 33.0 (b) T7 160 - 140 Secondary L 3 x 3 x 3/16 115 -4.69 14.12 33.2 Pass Horizontal 40.8 (b) T8 140 - 120 Secondary L 3 x 3 x 3/16 ,136 -6.02 11.04 54.5 Pass Horizontal T9 120 -100 Secondary L 3 x 3 x 1/4 157 -7.39 11.56 63.9 Pass Horizontal T1 250 - 240 Top Girt L 2 x 2 x 3/16 5 -0.12 6.81 1.8 Pass T10 100 - 80 Redund Horz 1 2L 2 x 2 x 3/16 (112) 181 -8.37 37.60 22.3 Pass Bracing T11 80 - 60 Redund Horz 1 2L 2 x 2 x 3/16 (112) 222 -9.77 34.30 28.5 Pass Bracing T12 60 - 40 Redund Horz 1 21. 2-x 2 x 3/16 (112) 271 -11.06 30.68 36.0 - - - --Pass -- Bracing T13 40 - 20 Redund Horz 1 21. 2 x 2 x 3116 (112) 331 -12.42 26.74 46.5 Pass Bracing T14 20 - 0 Redund Horz 1 21. 2 x 2 x 3116 (112) 388 -13.75 23.14 59.4 Pass Bracing T10 100 - 80 Redund Diag 1 21. 2 x 2 x 3116 (1/2) 204 -5.93 22.31 26.6 Pass Bracing T11 80 - 60 Redund Diag 1 2L 2 x 2 x 3116 (1/2) 246 -6.64 20.05 33.1 Pass Bracing T12 60 - 40 Redund Diag 1 2L 2 x 2 x 3116 (1/2) 297 -7.26 18.14 40.0 Pass Bracing T13 40 - 20 Redund Diag 1 2L 2 x 2 x 3116 (1/2) 360 -7.92 16.45 48.1 Pass Bracing T14 20 - 0 Redund Diag 1 2L 2.5 x 2.5 x 3/16 (1/2) 422 -8.55 28.64 29.8 Pass Bracing T12 60 - 40 Redund Hip 1 L 2.5 x 2.5 x 3116 314 -0.10 11.81 0.9 Pass Bracing T13 40 - 20 Redund Hip 1 L 2.5 x 2.5 x 3116 342 -0.09 10.12 0.9 Pass Bracing T14 20 - 0 Redund Hip 1 L 2.5 x 2.5 x 3/16 428 -0.09 8.78 1.0 Pass Bracing T12 60 - 40 Redund Hip L 2.5 x 2.5 x 3116 315 -0.14 3.31 4.3 Pass Diagonal 1 Bracing T13 40 - 20 Redund Hip L 2.5 x 2.5 x 3/16 372 -0.12 2.91 4.1 Pass Diagonal 1 Bracing T14 20 - 0 Redund Hip L 2.5 x 2.5 x 3/16 429 -0.12 2.57 4.7 Pass Diagonal 1 Bracing T10 100 - 80 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 195 -0.03 10.31 0.3 Pass T11 80 - 60 Inner Bracing 2L 2 x 2 x 3/16 (318) 240 -0.03 8.59 0.4 Pass T12 60 - 40 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 290 -0.06 7.27 0.8 Pass T13 40 - 20 Inner Bracing 21. 2.5 x 2.6 x 3116 (3/8) 347 -0.08 12.48 0.6 Pass T14 20 - 0 Inner Bracing 2L 2.5 x 2.5 x 3116 (3/8) 404 -0.04 10.81 0.4 Pass Summary Leg (T14) 73.4 Pass Diagonal 75.6 Pass (T12) Horizontal 73.1 Pass (T12) - Secondary 63.9 Pass Horizontal tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 May 1, 2019 CCI BU No 813700 Page 34 Section Elevation Component Size Critical P opm % Pass No. R Type Element K K Capacity Fail (T9) Top Girt.. 1.8 Pass (T1) - Redund 59.4 Pass Horz 1 Bracing (T14) Redund 48.1 Pass Diag 1 Bracing (T13) Redund 1.0 Pass Hip 1 Bracing (T14) . Redund 4.7 Pass Hip Diagonal 1 Bracing (T14) Inner 0.8 Pass Bracing (T12) Bolt 75.6 Pass Checks RATING = 75.6 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 APPENDIX B BASE LEVEL DRAWING May 1, 2019 CC/ BU No 813700 Page 35 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 APPENDIX C ADDITIONAL CALCULATIONS May 1, 2019 CC/ BU No 613700 Page 36 tnxTower Report - version 8.0.5.0 C�I�late ' 1 ect Information Site Name Order# .Applied 1 1 Comp. I Uplift Axial k -,r' 830.00 ,--712.00° Shear k ; 96:OOr k'w'm8500� Anchor '11 Data, Quantity Diameter (in):2 75 Material Grade _^ A36 Grout Considered: Yes Eta Factor, : 0.55 Thread Type] 'N-Included "' Configuration: '-S "mmet'ncal„ ,Anchor• 1 1 Results Axial, Pu c (kips) 138.33 Shear, Vu (kips) 16.00 Moment, Mu (kip -in) - Axial Cap., Pn c (kips) 177.48 Shear Cap., (bVn (kips) 53.24 Moment Cap., Q)Mn kip -in - Stress Rating 82.8% ❑✓ Apply TIA-222-H Section 15.5 Fy=36 ksi Fu=58 ksi Not Considered, lar<=1(d) Pass CClplate - version 3.5.0 Analysis Date: 5/1/2019 6 & OF COMPANY 250 E Broad St, Ste 600 • Columbus, OH 43215 Phone 614.221.6679 www.pauljford.Com Tower Manufacturer's Drawing Information Manufacturer: FWT Drawing #: S98-1019-A Drawings Date: 1 5/15/1998 Reactions Modified Page 1 of 1 By MRB Date 2/14/2019 Project # 37519-0281 Current Analvsis I Ratio The original tower design was completed in accordance with TIA/EIA-222-F standard. Per section 15.6.2 of the TIA-222-H standard, the reactions from the original design shall be multiplied by 1.35 for comparison to the reactions from this analysis. v0.1 - Effective Date 2-20-14 ASCEO Address: No Address at This Location Wind Results: ASCE 7 Hazards Report Standard: ASCE/SEI 7-10 Elevation: 23.53 ft (NAVD 66) Risk Category: II Latitude: 27.4833 Soil Class: D - Stiff Soil Longitude:-80.567 j Q I i vi - � /vw _ µ 45 Wind Speed: 153 Vmph 10-year MRI 66 Vmph 25-year MR[ 104 Vmph 50-year MR[ 115 Vmph 100-year MRI 126 Vmph Data Source: ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1—CC-4, incorporating errata of March 12, 2014 Date Accessed: Tue Jan 22 2019 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is in a hurricane -prone region as defined in ASCE/SEI 7-10 Section 26.2. Glazed openings shall be protected against wind-borne debris as specified in Section 26.10.3. Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind conditions. httosj/asee7hazardtool.online/ Page 1 of 3 Tue Jan 22 2019 A -MCE AMatlCAN SO' C EN OFO MENONEM Seismic Site Soil Class: D - Stiff Soil Results: Ss : 0.059 Sos : 0.063 S, : 0.03 SDI : 0.048 Fa : 1.6 TE : 8 F,.: 2.4 PGA: 0.028 SMs 0.094 PGA M : 0.045 SMI 0.072 FPS, 1.6 Ia : 1 Seismic Design Category A Data Accessed: Tue Jan 22 2019 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2. Additional data for site -specific ground motion procedures in accordance with ASCE/SEI 7-10 Ch. 21 are available from USGS. httos://asce7hazardtool.onfine/ Page 2 of 3 Tue Jan 22 2019 a• AMM1CMSe MYOFMENGINM Ice Results: Ice Thickness: Concurrent Temperature: Gust Speed: Data Source: Date Accessed: 0.00 in. 25 F 30 mph Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8 Tue Jan 22 2019 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Toot is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, _ currency, or quality of any data provided herein: Any third -parry links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third -parry content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. httpsJ/asee7hazardtool online/ Page 3 of 3 Tue Jan 22 2019 V UL J. FORD 0F &COMPANY Date: May 1, 2019 Andera Slaughter Crown Castle 8000 Avalon Blvd, Suite 700 Alpharetta, GA 30009 Subject: Carrier Designation: Crown Castle Designation: SCANNED BY St. Lucie County Paul J. Ford and Company 250 East Broad st., Suite 600 Columbus, OH 43215 (614) 221-6679 Structural Analysis Report AT&T Mobility Co -Locate Carrier Site Number: Carrier Site Name: Crown Castle BU Number: Crown Castle Site Name: Crown Castle JDE Job Number: Crown Castle Work Order Number: Crown Castle Order Number: 10080462 FP33 (MINUMAID) 813700 MINUTE MAID BRA360 553217 1694638 475132 Rev. 4 Engineering Finn Designation: Paul J. Ford and Company Project Number: 37519-0281.002.8700 R1 Site Data: 2651 Minute Maid Road, Ft. Pierce St. Lucie County, F Latitu a 27' 29' ",Longitude -80' 34' 1.3" 250 Foot - Self Support Tower Dear Andera Slaughter, Paul J. Ford and Company is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 153 mph as required by the 2017 Florida Building Code, 6t^ Edition. Applicable Standard referen1n pI j design criteria are listed in Section 2- Analysis Criteria. Respectfully submitted by: \e-. LEE `F1.gLi. Matthew Buske, P.E. Project Engineer mbuske@pauljford.com * No. 80107 1� �1 STATE OF /1ko .,O�� sLNA; FILE Copy MAY 012019 tnxTower Report - version 8.0.4.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order475132, Revision 4 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 — Tower Component Stresses vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations _ u May 1, 2019 CCI BU No 813700 Page 2 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0261.002.8700, Order47513Z Revision 4 1) INTRODUCTION May 1, 2019 CCI BU No 813700 Page 3 This tower is a 250 ft Self Support tower designed by FWT INC. in May of 1998. The tower was originally designed for a wind speed of 110 mph per TIA/EIA-222-F. The tower has been modified multiple times in the past to accommodate additional loading. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 153 mph Exposure Category: C Topographic Factor: 1 Service Wind Speed: 60 mph Table 1 - Proposed Equipment Configuration - Mounting Level (ft) Center Line Elevation Elevation Number of Antennas Antenna Antenna Model Manufacturer Number of Feed Lines .r Feed Line Size (in)(ft' 3 commscope SBNHH-1D85C 1 j— ericsson RRUS 32 200.0 6 1 5/8 1 ericsson RRUS 4449 B5/B12 195.0 3 3/4 r 1 erics_son RRUS 8843 B2/B66A 4 3/8 1 ra ca DC6-48-60-18-8F 195.0 1 connect -it PVFM12-3-3-96 Sector Frame j 2 ericsson RRUS 32 2 ericsson RRUS 4449 B5/B12 14 1 5/8 2 ericsson RRUS 8843 B2/B66A 160.0 160.0 6 3/4 6 kathrein 80010966K 4 3/8 3 raycap DC6-48-60-18-8F 2 t connect -it PVFM1 6 Sector Frame tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 Table 2 - Other Considered Equipment May 1, 2019 CCI BU No 813700 Page 4 -Mounting( Lever(fty Center - Line Elevation of Antenna - s Antenna. Manufacturer Antenna Model Number o0d"ed t4nes Feed Line Size (in) 11370 238.0 1 decibel 932DG33T2A-M 9 15/8 2 decibel 950G65VTZE-M 1 kathrein 742218 237.0 1 liii tower mounts Side Arm Mount [SO 305- 2124.0 225.0 3 decibel DB848H105ESX 6 15/8 3 decibel DB878H120ESX 224.0--- 2 tower mounts Sector Mount [SM 409-1] 217.0 217.0 3 andrew SBNHH-1D65C 12 3 15/8 11/4 6 cellmax technologies CMA-BDHH/6520/EO-8 3 nokia FRIG 6 2 nokia raycap FXFB _RNSNDC-7771-PF-48._ 1 tower mounts Sector Mount [SM 404-3] 207.0 210.0 2 cci antennas HPA33R-CS4AA-K1 3 1 3/32 1 commscope TTTT65AP-lXR 3 encsson RRUS 31 B25 3 ericsson RRUS 82 W/SOLAR -SHIELD f 3 ericsson I RRUS-1 1 80OMHZ f 3 rfs celwave ACU-A20-N I rfs celwave APXV9ERR18-C-A20 207.0 - 2 tower mounts Sector Mount [SM 301 -1] I tower mounts Sector Mount [SM 502-1] 780T 180.0 1 3 decibel D6848H105ESX 1 I 178.0 1 1 tower mounts Sector Mount [SM 409-1] 3 5/8 128.0 128.0 1 radlowaves; SPD2-5.8 1 1/2 I tower mounts Ripe Mount [PM 601-1] 120.0 120.0 1 1 a drew HPX6-59-P3A/K____ 1 ceragon FIBEAIR 1500HP 1 tower mounts Pipe Mount [PM 601-1] tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 3) ANALYSIS PROCEDURE Table 3 - Documents Provided May 1, 2019 CC/ BU No 813700 Page 5 Document s Remarks Reference Source GEOTECHNICAL REPORTS PSI, 097 85050-3, 10/12/1998 4 429429 CCISITES POST -MODIFICATION B&T/Morrison Hershfield, INSPECTION #82906.002/6110008.00/CNO- 3041481 CCISITES 223R8, 10/14/11 TOWER FOUNDATION PSI #772-80085-16a, 12/07/1998 447987 CCISITES DRAWINGS/DESIGN/SPECS TOWER MANUFACTURER FWT, #16922, 05/15/1998 245820 CCISITES DRAWINGS . _ .._._...._....--._.___.-- TOWER REINFORCEMENT Morrison Hershfield, #6013009, 3106450 CCISITES DESIGN/DRAWINGS/DATA 06/01/2001 3 TOWER REINFORCEMENT B&T Engineering, #82906.002, 2918494 CCISITES DESIGN/DRAWINGS/DATA 7/7/2011 3.1) Analysis Method tnxTower (version 8.0.5.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturers specifications. 2) The tower and structures have been maintained in accordance with the manufacturers specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Paul J. Ford and Company should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) q Section { Section Elevation (ft) Component Type Size Critical Element; P (� SF•P allow (IQ % Capacity Pass /Fail T1 250 - 240 Leg 2" solid 2 -1.84 51.75 3.6 Pass T2 240 - 220 Leg 3" solid 20 -18.51 144.96 ' 12.8 Pass T3 220-200 Leg 31/2'solid 41 -68.39 246.21 27.8 Pass i T4 1200 - 186.667 ? Leg 4' solid 61 -110.81 371.28 ' 29.8 Pass i T5 1186.667 - 180 Leg 4" solid 76 -132.10 371.28 I 35.6 Pass T6 180 - 160 ? Leg 4- solid 86 -193.01 446.95 43.2 Pass j T7 160 - 140 Leg 4 1/4' solid 107 -270.24 522.41 51.7 Pass T8 ( 140 - 120 # Leg 4 1/2' solid 128 347.23 602.61 57.6 Pass T9 i 120 - 100 Leg 4 3/4" solid 149 f -425.94 687.57 61.9 Pass T10 100 - 80 Leg 5" solid 170 -482.62 783.48 61.6 Pass T11 j 80 - 60 Leg 5" solid 215 +-563.25. 783.48 71.9 Pass F T12 ; 60 - 40 Leg 5 1/4" solid 260 -637.60 877.46 72.7 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 6 6 Seetlon Crlttcat - SF'P allow `°k - t No. Elevation (ft). ;- Component Type S,=® _ . Element ' P (In -, .. ` (iq ; ,, Capaeity Pass / Fall - T13 40-20 Leg 51/2'solid 318 -716.41 976.23 73.4 Pass T14 20 - 0 _ �_. Leg 5 3/4' solid 375 -792.65 1079.75 ' 73.4 Pass T1 250 - 240 Diagonal L 2 x 2 x 3/16 7 -0.88 15.66 5.6 Pass T2 240 - 220 Diagonal L 3 x 3 x 3/16 27 -4.67 26.87 17'4 125.2_(b) Pass T3 220 - 200 Diagonal L 3 x 3 x 1/4 48 ; -10.11 29.97 33.7 Pass 41.4 IT4 200 - 186.667 Diagonal L 3 x 3 x 1/4 68 -11 76 25.46 2 1 Pass 49.4 I T5 186 .6 67- 180 Diagonal 2L 3 x 3 x 1/4 (3/8) 83 ( 12.24 80.04 5 3 15.325.8 Pass T6 180 - 160 Diagonal 2L 2.5 x 2.5 x 3/16 (1Y2) 92 -15.38 31.54 48.8 Pass T7 160 - 140 _.. Diagonal 2L 2.5 x 2.5 x 3/16 (112) 111.. ( -18.38 26.31 69.8 Pass T8 140 - 120 Diagonal 2L 3 x 3 x 3/16 (112) 134 -21.09 37.83 55.8 Pass 5B.4 (b) T9 120 - 100 Diagonal 2L 3 x 3 x 3116 (1/2) 155 ! -24.97 33.07 75.5 Pass i T10 100 - 80 Diagonal 2L 3 x 3 x 5/16 (1/2) 187 } -35.98 55.28 65.1 Pass _T11 4 80 - 60 Diagonal 2L 3 x 3 x 5/16 (1/2) 232 -35A9 49.67 71 A Pass T12 60 - 40 Diagonal 2L 3 x 3 x 1/4 (112) 279 -38.65 70.43 4.9 Pass 7 T13 40 - 20 Diagonal 2L 3 x 3 x 5/16 (1/2) 336 .38.24 81.35 Pass 647 (b) T14 20 - 0 Diagonal 2L 3 x 3 x 5/16 (1/2) 393 -40.28 76.16 9 Pass--- 69.5 T10 100 - 80 Horizontal 2L 2.5 x 2.5 x 3/16 (1/2) 172 -8.37 21.54 Pass l 438 (b) Tl l 80 - 60 Horizontal 2L 2.5 x 2.5 x 3116 (1/2) 217 ( -9.77 17.89 54.6 Pass T12 60 - 40 Horizontal 2L 2.5 x 2.5 x 3/16 (1/2) 262 -11.06 15.12 73.1 Pass T13 40 - 20 _ .. Horizontal 2L 3 x 3 x 3116 (112) 326 -12.42 22.12 56.2 Pass ' T14 20 - 0 l Horizontal 2L 3 x 3 x 3116 (1/2) 392 -13.75 _ 19.14 71.8 - Pass 6 T6 180 - 160 Secondary L 2.5 x 2.5 x 3/16 94 -3.44 10.67 32.2 Pass Horizontal 33.0 (b) T7 160 - 140 (( Secondary L 3 x 3 x 3/16 115 i 4.69 14.12 33.2 1 Pass 1 Horizontal 40.8 (b) I T8 140 - 120 Secondary L 3 x 3 x 3/16 136 -6.02 11.04 54.5 Pass I Horizontal 1 T9 - 100 SecondaHorizontal L 3 x 3 x 1/4 157 -7.39 11.56 63.9 Pass _120 T1 250 - 240 Top Girt L 2 x 2 x 3116 5 ( -0.12 6.81 1.8 Pass T10 100 - 80 Redund1 2L 2 x 2 x 3/16 (1/2) 181 -8.37 37.60 22.3 Pass Brac' ngrz _ T11 80 - 60 Redund Horz 1 2L 2 x 2 x 3/16 (1/2) 222 -9.77 34.30 28.5 Pass Bracing T12 60 - 40 Redund Horz 1 2L 2 x 2 x 3/16 (1/2) 271 -11.06 30.68 36.0 Pass Bracing 513 40-20Redund T13 40 - 20 Horz 1 2L 2 x 2 x 3l16 (1/2) 331 -12.42 26.74 46.5 Pass Bracing T14 20 - 0 Redund 1 2L 2 x 2 x 3/16 (1/2) 388 -13.75 23.14 I 59.4 Pass ngrz BraciT10 100 - 80 Redund Diag 1 2L 2 x 2 x 3/16 (1/2) 204 -5.93 22.31 26.6 Pass Bracing ' Tit 80 - 60 Redund Diag 1 2L 2 x 2 x 3/16 (1/2) 246 -6.64 20.05 33.1 Pass Bracing T12 60 -40 ! Redund 1 2L 2 x 2 x 3/16 (1/2) 297 -7.26 18.14 40.0 Pass t BracinDgiag T13 40 - 20 Re grading g 1 2L 2 x 2 x 3/16 (1/2) 360 -7.92 16.45 48.1 Pass tnxTower Report - version 8.0.5.0 250 Ft Sell Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CCI BU No 813700 Page 7 {Section - Elevatlon (8) Component Type Size Critical' P (K) - SF'P allow %' Pass [Fall' No. e .. , ,;; Element , . (� C2padty , T14 20 - 0 �_ dcDigagl 2L 2.5 x 2.5 x 3/16 (1/2) 422 -8.55 28.64 29.8 Pass _.. ..j.RedB i ... _ -r ._... ._..._ T12 60-40 Redund Hip 1 L2.Sx2.5x3/16 314 -0.10 11.81 f 0.9 Pass _..... Bracing _ _ P { T13 4 40 - 20 Redund Hip 1 Bracing L 2.5 x 2.5 x 3/16 342 -0.09 10.12 _ 0.9 Pass �. T14 20 0 ReB eai gip 1 L 2.5 x 2.5 x 3/16 428 -0.09 8.78 1.0 Pass _ Redund Hip f T12 60 - 40 Diagonal 1 L 2.5 x 2.5 x 3/16 315 f -0.14- 3.31 4.3 Pass Bracing j Redund Hip T13 40 - 20 Diagonal 1 L 2.5 x 2.5 x 3/16 372 ( -0.12 2.91 4.1 Pass Bracing ji -Redund Hip T14 i 20 - 0 Diagonal 1 L 2.5 x 2.5 x 3/16 429 -0.12 2.67 4.7 Pass j Bracing T10 100 - 80 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 195 -0.03 10.31 p 0.3 Pass Tit 80 - 60 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 240 -0.03 8.59 _ 0.4 Pass T12 j 60 - 40 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 290 -0.06 7.27 0.8 Pass T13 40 - 20 Inner Bracing 2L 2.5 x 2.5 x 3116 (3/8) 347 -0.08 12.48 0.6 Pass T14 20 - 0 Inner Bracing 2L 2.5 x 2.5 x 3/16 (3/8) 404 -0.04 10.81 .....;Summary. 0.4 Pass ..-.. _ Leg (T14)_ 73.4 _ Pass Diagonal 75.6 Pass R12) , ... HoM �. 73.1 Pass 2,fa1.. Secondary Horizontal 63.9 Pass .. - __. . _. Top Girt 1.8 Pass - � Redund Horz 1 59.4 Pass Bracing (T14) Redund Diag 1 48.1 Pass Bracing (T13) Redund Hip 1 Bracing 1.0 Pass (T14) Redund Hip Diagonal 1 4.7 Pass B14 (T)9 S! Inner Bracing 0.8 Pass j (T12) Bolt Checks 75.6 Pass Rating = 1 75.6 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 Table 5 - Tower Component Stresses vs. Capacity May 1, 2019 CC/ BU No 813700 Page 8 Notes Component Elevation tft).6paoly I Oass./-F ai 1 Anchor Rods 82.8 Pass Base Foundation 1,2 (Compared w/ 90-4 Pass Design Loads) Structure ROtinfg (m4x from all components) ,.�. Notes: 1) See additional documentation in 'Appendix C — Additional Calculations' for calculations supporting the % capacity consumed. 2) Foundation capacity determined by comparing analysis reactions to original design reactions. 3) All structural ratings are per TIA-222-H Section 15.5 4.1) Recommendations • The tower and its foundation have sufficient capacilyto carry the proposed load configuration. No modifications are required at this time. tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.6700, Order475132, Revision 4 APPENDIX A TNXTOWER OUTPUT May 1, 2019 CC/ BU No 813700 Page 9 tnxTower Report - version 8.0.5.0 :m p� F� i N �m N I 9 � I � rc m .� I g I - b d 2 did ziz d' z �I r y w Z N 2 a n M m � ;r�cl m N � m d z I I c' mi A C N 'a c C C rv' m irl NI z w N � N u3 A J 1% w cl N llflll 2404 R 220.0n 14, 20000 188.70 IB0_00 '. DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION BPaafl MO(Z)RRUS118p0MH2 207 '. UghhN Rod 5Rx4' Me HP/33RCS4A 1w/Mg R, 207 8320G3312A-Mw/Magid Rpe 237 RRU3 82 WISOLAR MnD Xr 742218WMard Rpe 237 AC11-A26N 207 SSGG65Vf�-Mw/MdeM1Pge Zi7 S Maad(SMWI-1) an 950G85VRE-Mw/Marl Pipe 237 SeaorMa Jsmwl-ij an SMeArm Mard($03054 M7 Sean Momd]SM502-1] M7 (3)DS84e1/05ESXw/M=t Rpe 04 ( smtiH-10BSCw/MasdAw 1d5 (3)OB81®11ZIF5%w/Mamt Rpa =4 RRU532 195 Saaor Moud(SM 40&1] JMUS444OBSIB12 Its Seaor Moa4(SM4041I 224 RRUS BB43 BNB684 195 SMHWID65C.t Maml RW 217 OC&18fiP188 105 SWHWIMSCw/Maud Rpe 217 P~2J398 Fwe 195 SMHWItX6Cw/Mamt Rpe 217 (3)D8848H1WESXw/Ma RN 178 CMA4XIHHB541ED8 217 Seav MauK[SM 4041] 176 CMABmH� 217 (2) DCB4B 1"F 160 (2)CMA-BOHHTb2WEm8 217 RRUSM 100 FRIG 217 RRUS 4449 BS/B12 160 FRIG 217 RRUSSa4392/B654 160 FRIG 217 (3)a0010966Kw/Moud Pipe 160 RNSNDC-7`M'F1B 217 RRUSU 160 RNSNOO'M14IF-48 217 RRU54449B&B12 160 (2)FXFB 217 RRUSaa4392/BBBn 1W (2)F)" 217 (3)8001aa86Kw/MmdRpa 160 (2) FXFB 217 DCB4Ba6184 160 Sector Ma [SM 40" 217 PVFa1123 965eaor Frame 160 TfriBSa Mw/MO Ppe M7 PVFa1123 96Sedor Frmne 160 (2)MUS31 B25 M7 Rpe Moad(PM601-1) In RRUSMW50LARSHK D =7 SPD2-5.6 in RRUSII SWMH2 M7 D64auo3m kin -in (2)ACWla1a4 207 COaaumon fight 125 A XA RR18GA2p w/Mamt Mm 21n OECWCOm ugM In HPXGRCS4A0.JOw/Mm Rpe 07' RSEAIR160191P In RRUS 31225 207 Rpe Mamt jPman-tl Im RRUSWWI60LARSHIEU) Jim SYMROI 1 IRT MARK- SIZE I MARK SIZE A SRTeald I C X3a3i1/4(3/8) B L2u2u&iB D 2L 25x2.5 u3116 (irzJ 80_0a TOWER DESIGN NOTES 1. Tower designed for Exposure C to the TIA-222-H Standard. \ / 2. Tower designed for a 153.00 mph basic wind in accordance with the TIA-222-H Standard. ---- ----- 3. Deflections are based upon a 60.00 mph wind. i 4. Tower Risk Category II. --"'� < ---- 5. ToDogmphic Category 1 with Crest Height of 0.00 it W.0a 6. TIA-222-H Annex S 7. TOWER RATING: 75.6% ALL REACTIONS C.�-..__...♦�,, \. __,... ... AREFACTORED -- MAX. CORNER REACTIONSAT BASE: 40.0 n - DOWN: 930 K SHEAR: 96 K ----- - - -- UPLIFT.- -712 K SHEAR: 85 K M.0 Rn AXIAL --- SHEAR MOMENT -- --- 159K 2044Ekp-8 a00 . TORQUE2741dp-ft REACTIONS-153.00 mph WIND Paul J. Ford and Coml 250 East Broad St., Suite I Columbus, OH 43215 Phone: (614) 221-6679 Tower Ft. 519-0281) May 1, 2019 250 Ft Self Support Tower Structural Analysis CCI BU No 813700 Project Number 37519-0281.002.8700, Order475132, Revision 4 Page 10 Tower Input Data The main tower is a 3x free standing tower with an overall height of 250.00 ft above the ground line. The base of the tower is set at an elevation of 0.00 ft above the ground line. The face width of the tower is 6.00 ft at the top and 30.00 ft at the base. This tower is designed using the TIA-222-H standard. The fallowing design criteria apply: 1) Tower base elevation above sea level: 24.00 ft. 2) Basic wind speed of 153.00 mph. 3) Risk Category II. 4) Exposure Category C. 5) Simplified Topographic Factor Procedure for wind speed-up calculations is used. 6) Topographic Category: 1. 7) Crest Height: 0.00 ft. 8) Deflections calculated using a wind speed of 60.00 mph. 9) TIA-222-H Annex S. 10) A non -linear (P-delta) analysis was used. 11) Pressures are calculated at each section. 12) Stress ratio used in tower member design is 1.05. 13) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios 4 Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile 4 Include Bolts In Member Capacity Leg Bolts Are At Top Of Section 4 Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) 4 SR Members Have Cut Ends SR Members Are Concentric Options Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wind Area Use Clear Spans For KUr Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area of Appurt. Autocalc Torque Ann Areas Add IBC .6D+W Combination 4 Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feed Line Bundles As Cylinder Ignore KUry For 60 Deg. Angle Legs Use ASCE 10 X-Brace Ly Rules 4 Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation 4 Consider Feed Line Torque 4 Include Angle Block Shear Check Use TIA-222-H Bracing Resist. Exemption Use TIA-222-H Tension Splice Exem tion 1'0as a Include Shear -Torsion Interaction Always Use Sub-Crifiral Flow Use Top Mounted Sockets Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Comer Radii Are Known tnxTower Report -version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 Wind 180 Lea A Wind 90 m� m Lem Z Leg B Face C Wmd Normal Triangular Tower May 1, 2019 CC/ BU No 813700 Page 11 Tower Section Geometryx Tower Tower Assembly Description Section Number Section Section Elevation Database Width of Length Sections It ft it T1 250.00-240.00 6.00 1 10.00 T2 240.00-220.00 6.00 1 20.00 T3 220.00-200.00 8.00 1 20.00 T4 200.00-186.67 10.00 1 13.33 T5 186.67-180.00 11.33 1 6.67 T6 180.00-160.00 12.00 1 20.00 T7 160.00-140.00 14.00 1 20.00 T8 140.00-120.00 16.00 1 20.00 T9 120.00-100.00 18.00 1 20.00 T10 100.00-80.00 20.00 1 20.00 T11 80.00-60.00 22.00 1 20.00 T12 60.00.40.00 24.00 1 20.00 T13 40.00-20.00 26.00 1 20.00 T14 20.00-0.00 28.00 1 20.00 Tower Section Geometry cont d Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type KBrace Horizontals Offset Offset End IT If Panels in in T1 250.00-240.00 5.00 X Brace No No 0.000 0.000 T2 240.00-220.00 6.67 X Brace No No 0.000 0.000 T3 220.00-200.00 6.67 X Brace No No 0.000 0.000 T4 200.00-186.67 6.67 X Brace No No 0.000 0.000 T5 186.67-180.00 6.67 X Brace No No 0.000 0.000 T6 180.00-160.00 10.00 X Brace No Yes 0.000 0.000 T7 160.00-140.00 10.00 X Brace No Yes 0.000 0.000 T8 140.00-120.00 10.00 X Brace No Yes 0.000 0.000 T9 120.00-100.00 10.00 X Brace No Yes 0.000 0.000 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.6700, Order475132, Revision 4 May 1, 2019 CCI BU No 813700 Page 12 Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type KBrace Horizontals Offset Offset End It it Panels in in T10 100.00-80.00 10.00 Double K1 No Yes 0.000 0.000 T11 80.00-60.00 10.00 Double K1 No Yes 0.000 0.000 T12 60.0040.00 10.00 Double K1 No Yes 0.000 0.000 T13 40.00-20.00 10.00 Double K1 No Yes 0.000 0.000 T14 20.00-0.00 10.00 Double K1 No Yes 0.000 0.000 Tower Section Geometry cont'd Tower Leg Leg Leg Diagonal Diagonal Diagonal Elevation Type Size Grade Type Size Grade R T1 250.00- Solid Round 2" solid A572-50 Equal Angle L 2 x 2 x 3/16 A36 240.00 (50 ksi) (36 ksi) T2 240.00- Solid Round 3" solid A572-50 Equal Angle L 3 x 3 x 3116 A36 220.00 (50 ksi) (36 ksi) T3 220.00- Solid Round 3 1/2" solid A572-50 Equal Angle L 3 x 3 x 1/4 A36 200.00 (50 ksi) (36 ksi) T4 200.00- Solid Round 4" solid A572-50 Equal Angle L 3 x 3 x 1/4 A36 186.67 (50 ksi) (36 ksi) TS 186.67- Solid Round 4" solid A572-50 Double Equal 2L 3 x 3 x 1/4 (3/8) A36 180.00 (50 ksi) Angle (36 ksi) T6 180.00- Solid Round 4" solid A572-50 Double Equal 2L 2.5 x 2.5 x 3/16 (1/2) A36 160.00 (50 ksi) Angle (36 ksi) T7 160.00- Solid Round 4 1/4" solid A572-50 Double Equal 2L 2.5 x 2.5 x 3/16 (1/2) A36 140.00 (50 ksi) Angle (36 ksi) T8 140.00- Solid Round 4 IM'solid A572-50 Double Equal 2L 3 x 3 x 3/16 (1/2) A36 120.00 (50 ksi) Angle (36 ksi) T9 120.00- Solid Round 4 3/4" solid A572-50 Double Equal 2L 3 x 3 x 3/16 (1/2) A36 100.00 (50 ksi) Angle (36 ksi) T10 100.00- Solid Round 5" solid A572-50 Double Equal 2L 3 x 3 x 5/16 (1/2) A36 80.00 (50 ksi) Angle (36 ksi) T11 80.00- Solid Round 5" solid A572-50 Double Equal 2L 3 x 3 x 5116 (1/2) A36 60.00 (50 ksi) Angle (36 ksi) T12 60.00- Solid Round 5'IM' solid A572-50 Double Equal 2L 3 x 3 x 1/4 (1/2) A36 40.00 (50 ksi) Angle (36 ksi) T13 40.00- Solid Round 5 1/2" solid A572-50 Double Equal 2L 3 x 3 x 5116 (1/2) A36 20.00 (50 ksi) Angle (36 ksi) T14 20.00-0.00 Solid Round 5 3/4" solid A572-50 Double Equal 2L 3 x 3 x 5/16 (1/2) A36 (50 ksi) Angle (36 ksi) Tower Section Geometry cont'd Bottom Girt Tower Top Girt Top Girt Top Girt Bottom Girt Bottom Girt Elevation Type Size Grade Type Size Grade it T1 250.00- Equal Angle L 2 x 2 x 3116 A36 Equal Angle A36 240.00 (36 ksi) (36 ksi) Tower Section Geometry cont'd Tower No. Mid Girt Mid Gift Mid Girt Horizontal Horizontal Horizontal Elevation of Type Size Grade Type Size Grade Mid T10 100.00- None Single Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 A36 80.00 (36 ksi) Angle (1/2) (36 ksi) tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 13 Tower No. Mid Girt Mid Girt Mid Girt Horizontal Horizontal Horizontal Elevation of Type Size Grade Type Size Grade Mid It Gifts T11 80.00- None Single Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 A36 60.00 (36 ksi) Angle (1/2) (36 ksi) T12 60.00- None Single Angle 'A36 Double Equal 2L 2.5 x 2.5 x 3/l6 A36 40.00 (36 ksi) Angle (1/2) (36 ksi) T13 40.00- None Single Angle A36 Double Equal 21. 3 x 3 x 3/16 (1/2) A36 20.00 (36 ksi) Angle (36 ksi) T14 20.00-0.00 None Single Angle A36 Double Equal 2L 3 x 3 x 3/16 (112) A36 (36 ksi) Anale (36 ksi) Tower Section Geoinet cont'd Tower Secondary Secondary Horizontal Secondary InnerBracing Inner Bracing Size InnerBracing Elevation Horizontal Type Size Horizontal Type Grade Grade B T6 180.00- Equal Angle L 2.5 x 2.5 x 3116 A36 Equal Angle L 2 x 2 x 3/16 A36 160.00 (36 ksi) (36 ksi) T7 160.00- Equal Angle L 3 x 3 x 3/16 A36 Equal Angle L 2 x 2 x 3/16 A36 140.00 (36 ksi) (36 ksi) T8 140.00- Equal Angle L 3 x 3 x 3/16 A36 Equal Angle L 2.5 x 2.5 x 3/16 A36 120.00 (36 ksi) (36 ksi) T9 120.00- Equal Angle L 3 x 3 x 1/4 A36 Equal Angle L 2.5 x 2.5 x 3116 A36 100.00 (36 ksi) (36 ksi) T10 100.00- Equal Angle A36 Double Equal -2L.2 x 2 x 3116 (3/8) A36 80.00 (36 ksi) Angle (36 ksi) T11 80.00- Equal Angle A36 Double Equal 2L 2 x 2 x 3/16 (3/8) A36 60.00 (36 ksi) Angle (36 ksi) T12 60.00- Equal Angle A36 Double Equal 2L 2 x 2 x 3/16 (3/8) A36 40.00 (36 ksi) Angle (36 ksi) T13 40.00- Equal Angle A36 Double Equal 2L 2.5 x 2.5 x 3116 (3/8) A36 20.00 (36 ksi) Angle (36 ksi) T14 20.00-0.00 Equal Angle A36 Double Equal 2L 2.5 x 2.5 x 3/16 (3/8) A36 (36 ksi) Angle (36 ksi) Tower.Section Geomet cont'd Tower Redundant Redundant Redundant KFactor Elevation Bracing Type Size Grade T10 100.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3116 (1/2) 80.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3116 (1/2) Double Equal Angle T11 80.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3/16 (112) 60.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3/16 (1/2) - Double Equal Angle T12 60.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3/16 (1/2) 40.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3116 (1/2) Hip (1) Double Equal L 2.5 x 2.5 x 3/16 Hip Diagonal Angle L 2.5 x 2.5 x 3116 (1) Equal Angle Equal Angle T13 40.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3/16 (112) 20.00 (36 ksi) Diagonal (1) Angle 2L 2 x 2 x 3/16 (112) Hip (1) Double Equal L2.5 x 2.5 x 3/16 Hip Diagonal Angle L 2.5 x 2.5 x 3/16 (1) Equal Angle tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No 813700 Project Number37519-0281.002.8700, Order475132, Revision 4 Page 14 Tower Redundant Redundant Redundant KFactor Elevation Bracing Type Size Grade Equal Angle T14 20.00- A36 Horizontal (1) Double Equal 2L 2 x 2 x 3/16 (1/2) 1 0.00 (36 ksi) Diagonal (1) Angle 2L 2.5 x 2.5 x 3/16 (1/2) 1 Hip (1) Double Equal L 2.5 x 2.5 x 3/16 1 Hip Diagonal Angle L 2.5 x 2.5 x 3/16 1 (1) Equal Angle Tower Section Geometry cont'd Tower Gusset Gusset Gusset GradeAdjust. Factor Adjust. Weight Mutt. Double Angle Double Angle Double Angle Elevation Area Thickness At Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Spacing Diagonals Horizontals Redundants T1 250.00- 2.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid-rt Mid-Yt 240.00 - (36 ksi) T2 240.00- 0.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 220.00 (36 ksi) T3 220.00- 0.00 0.375 A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 200.00 (36 ksi) T4 200.00- 0.00 0.375. A36 1.03 1 1.1 Mid -Pt Mid -Pt Mid -Pt 186.67 (36 ksi) T5 186.67- 0.00 0.375 A36 1.03 - 1 1.1 Mid -Pt Mid -Pt Mid -Pt 180.00 (36 ksi) T6 180.00- 0.00 0.375 A36 1.03 1 1.1 47.400 Mid -Pt Mid -Pt 160.00 (36 ksi) T7 160.00- 0.00 0.375 A36 1.03 1 1.1 26.175 Mid -Pt Mid -Pt 140.00 (36 ksi) T8 140.00- 0.00 0.375 A36 1.03 1 1.1 57.480 Mid -Pt Mid -Pt 120.00 (36 ksi) T9 120.00- 0.00 0.375 A36 1.03 1 1.1 31.380 Mid -Pt Mid -Pt 100.00 (36 ksi) T10 100.00- 0.00 0.500 A36 1.03 1 1.1 39.400 58.500 Mid -Pt 80.00 (36 ksi) T11 80.00- 0.00 0.500 A36 1.03 1 1.1 42.000 64.500 Mid -Pt 60.00 (36 ksi) T12 60.00- 0.00 0.500 A36 1.03 1 1.1 44.000 70.500 Mid -Pt 40.00 (36 ksi) T1340.00- 0.00 0.500 A36 1.03 1 1.1 46.400 76.500 Mid -Pt 20.00 (36 ksi) T1420.00- 0.00 0.500 A36 1.03 1 1.1 49.000 82.500 Mid -Pt 0.00 (36 ksi) Tower Section Gedmet cont'd K Factors' Tower Cato Cato Legs X K Single Gins Hodz Sec. Inner Elevation K K Brace Brace Diags Hodz Brace Single Solid Diags Diags Angles Rounds X X X X X X X it Y Y Y Y Y Y Y T1250.00- No No 1 1 1 1 1 1 1 1 240.00 1 1 1 1 1 1 1 T2 240.00- No No 1 1 1 1 1 1 1 1 220.00 1 1 1 1 1 1 1 T3 220.00- No No 1 1 1 1 1 1 1 1 200.00 1 1 1 1 1 1 1 T4 200.00- No No 1 1 1 1 1 1 1 1 186.67 1 1 1 1 1 1 1 T5186.67- No No 1 1 1 1 1 1 1 1 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 May 1, 2019 CCI BU No 813700 Page 15 K Factors' Tower Calc Cato Legs X K Single Gins Hodz Sec. Inner Elevation K K Brace Brace Diags Hodz Brace Single Solid Diags Diags Angles Rounds X X X X X X K R Y Y Y Y Y Y Y 180.00 1 1 1 1 1 1 1 - T6180.00- No No 1 1 1 1 1 1 1 1 160.00 1 1 1 1 1 0.5 1 77160.00- No No 1 1 1 1 1 1 1 1 140.00 1 1 1 1 1 0.5 1 T8140.00- . No No 1 1 1 1 1 1 1 1 120.00 1 1 1 1 1 0.5 1 T9120.00- No No 1 1 1 1 1 1 1 1 100.00 1 1 1 1 1 0.5 1 T10100.00- No No 1 1 1 1 1 1 1 1 80.00 1 1 1 1 1 1 1 T1180.00- No No 1 1 1 1 1 1 1 1 60.00 1 1 1 1 1 1 1 T1260.00- No No 1 1 1 1 1 1 1 1 40.00 1 1 1 1 1 1 1 T13 40.00- No No 1 1 1 1 1 1 1 1 20.00 1 1 1 1 1 1 1 T14 20.00- No No 1 1 1 1 1 1 1 1 0.00 1 1 1 1 1 1 1 'Note: K factors are applied t plane direction applied to the have the Kfactorin the out-cf- Tower Section Geomet cont'd __.___; _ _•' Tower Elevation It Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Net Width U Net U Net Width U Net U Net U Net U Net U Deduct Width Deduct Width Width Width Width in Deduct in Deduct Deduct Deduct Deduct in in in in in T1250.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 240.00 T2 240.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 220.00 T3 220.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 200.00 T4 200.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 186.67 T5186.67- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 180.00 T6180.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 160.00 T7160.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 140.00 T8140.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 120.00 T9120.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.76 100.00 T10100.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 80.00 T1180.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 60.00 T12 60.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 40.00 T13 40.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 20.00 T14 20.00- 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.00 tnxTower Report - version 8.0.5.0 O r O r r :pm '01•m� -_o •m m m1,10y m 3» o D w a— nD D i� o m D 0 m m D D D D D D CD m z z z z z z z z Sn p, O O O O O O O O. Q F r 0 0 0 0 0 0 0 0 =aa 0 u C r D D D D D D O O O O p O V O V O V O V V V O m O 00 00 0a a a 00'00006 m 0 0 6 S 6 b 6 o OT C1 O O O O (n O O O O O UI in fn O O o m O O O O O O O O \. CD 0 0 o p p ao� y 1 O O N N N INn p + N N W N N O N # M CL o ON O5'O+O+ O,P. . tJ OI O m O M O Z. O N C O OOOO m O m O m O O 0000 fp m m T O am O a 0 0 0 0 O mamma /y w O o 0 0 o O O = m a m� a p O + + O O + O O I ,m 0 O O o O+ O+ N+ A+ W+ m+ OC N O N N A N oN. A. 01. Ol. OONOA0010 W OCD O)OONOAON P7 V m p �� F 00000000 000000000mJ0000000 om O O O O G O O O O J o O O O C M Ip rp m Ip rn o m (c (p m ro o m � m m m m m m m m m m m m m m m m �p o ND+D+D+D+D�D+D+D+D+D+D+DoDo 0 D' W W W� W• W m W• W• W W• W W• W W W V t N J N J N O N O N O i N w N N N N N N N N N O N m N O O O O o V a N O J N •' [n Oi m m M O a z N M Z a Z z a z O ZoZOZOZoZOZrnZOZOZOZO ZOZ(n zM Z z z 0• m O O M O) W W T O] OI Ol W O W OI. A OZ DODODODODODODODODoDODODODODO o wwwWWWWWWww• ww• w NONONp1Np1N 01NTNOIN O)Np1N01N01NONTN W InNNN Nz Nz Nz Nz Nz NZNZNZNZN j'� zNtoNz Z N Z W Z N ZN Z N Z O Z N Z O Z N Z N Z N Z Z O Z O 0• O N N N N N N N N N N N N N N 02 N DO D O D o D O D o D O D o D o D oZ O D o D o �o D o 0 w• w� w� w� w� w� w� W� W� W� w_ W� s ZOZOZOZOZOZOZOZOZOZOZOZoZOZIn m' b O O O O O O O O O O O O O + Z p DoDoDoDoDoDoDoDoDoDoDoDoDo DO o m wWwwW• WWwWw• W• w• w• w N O N O N O N O N O N O N O N O N O N O N O N O N O N O� •� W O z O z O N O O O z O N O N O N O z O O O O O N O N O N z z z z z z z z z z z z z zOm O 3 O O O O O O O O O O O O O O OZ a DoDoDoDoDoDoDoDoDoDoDoDoDoDo 0 W. W W W W w. w. W w. w. w. w. w. W. NOf N W N W NONONO)NONOINONOlN01N OINO)N OI Nz Nz Nz Nz NzN j� VJ Z N Z Of Z W Z rn Z to Z N Z In Z W Z m Z to Z N Z fn Z fn Z N ZNZNZNZNZNZNzNzNz 0• C O O O O O O O O O O O O O O OZ Z Do D O D OD OD O Do DoD OD OD O Do D O Do Do p O NOf NOIN O)N W NOINONON ON O NONONONONo = o �O m z a z m z m z m z a z O N O N O N O z 0 0 0 O O N z Z Z Z Z Z Z Z0IV Ox m s + + + + + O O O O O O O O O 01 D oDoDoDoDoDoDoDoDoDoDoDoDoDo 0 WWWW W W W W W W W W W W N ONONONOf NOIN Of NOIN OIN OINON ONO NONO 0 am O j �' (A O f n V l t Z OZOZOZf11Z O1ZNZ01 ZfllZ (nZOZOZOZOZO m 00 0 0 0 0 0 + + + + o 0 0 0 o p 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 17 Description Face Allow Fircluda Componen Placement Face Lateral # # Clear Moth or Pedmete Weight or Shield From t Offset Offset Per Spacin Diameter r Leg Torque Type ft in (Frac FWJ Row g in p/f Calculation In in LCF158- B No No Ar (CaAa) 224.00 - 1.000 0.25 6 6 1.000 2.010 0.92 50J(1-5/8") 0.00 0.500 1.5" flat B No No At (CaAa) 224.00 - 0.000 0.25 2 2 18.000 1.50IN 1.80 ' Cable Ladder 0.00 0.500 Rail LDF5- B No No Ar (CaAa) 128.00 - -0.500 -0.25 1 1 1.910 1.090 0.33 50A(7/8") 0.00 0.500 TSZ 999 B No No Ar (CaAa) 207.00 - -0.500 -0.23 3 2 1.000 1.039 0.71 066/)=M- 0.00 1.039 BAWG(1- 1/32") 1.5" flat B No No At (CaAa) 210.00 - -0.500 -0.25 2 2 36.000 1.500 1.80 Cable Ladder 0.00 0.500 Rail • Face C 1" lighting C No No Ar (CaAa) 250.00- 1.000 0.5 1 1 - 24.000 1.000 2.00 conduit 0.00 0.000 LCF158- C No No Ar (CaAa) 195.00 - 0.000 0.4 6 6 0.890 2.010 0.92 50J(1-5/8") 160.00 0.500 LCF158- C No No Ar (CaAa) 160.00- 0.000 0.4 20 12 0.890 2.010 0.92 50J(1-5/8") 0.00 0.500 WR- C No No Ar (CaAa) 160.00- 2.000 0.43 9 4 0.774 0.774 0.59 VG86ST- 0.00 BRD(3/4) WR- C No No Ar (CaAa) 195.00 - 2.000 0.43 3 3 0.774 0.774 _ 0.59 VG86ST- "- -- - 160.00 BRD( 3/4) LDF2- C No No Ar (CaAa) 160.00- 0.000 0.38 8 4 0.440 0.440 0.08 50(3/8") 0.00 LDF2- C No No Ar (CaAa) 195.00 - 0.000 0.38 4 4 0.440 0.440 0.08 50(3/8") 160.00 1.5" flat C No No M (CaAa) 250.00- 0.000 0.4 2 2 36.000 1.500 1.80 Cable Ladder 0.00 0.500 Discrete Tower Loads -- Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft flz fF K ft ° ft Beacon B From Leg 0.00 0.000 250.00 No Ice 3.60 3.60 0.10 0.00 0.00 Obstruction light A From Leg 1.00 0.000 125.00 No Ice 0.50 0.50 0.01 0.00 0.00 Obstruction light B From Leg 1.00 0.000 125.00 No Ice 0.50 0.50 0.01 0.00 0.00 Obstruction light C From Leg 1.00 0.000 125.00 No Ice 0.50 0.50 0.01 0.00 0.00 Lightning Rod 5/8x4' C From Leg 0.00 0.000 250.00 No Ice 0.25 0.25 0.03 0.00 2.00 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CCI BU No 813700 Page 18 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Herz Adjustmen Front Side Leg Lateral - t Vert ft ft fF fl2 K ft ' ft 932DG33T2A-M w/ Mount A From Leg 4.00 0.000 237.00 No Ice 5.91 3.22 0.05 Pipe 0.00 1`AO 742 218 w/ Mount Pipe B From Leg 4:00 0.000 237.00 No Ice 4.10 3.00 0.04 0.00 1.00 950G65VTZE-M w/ Mount B From Leg 4.00 0.000 237.00 No Ice 4.23 4.20 0.03 Pipe 0.00 1.00 950G65V'rZE-M w/ Mount C From Leg 4.00 0.000 237.00 No Ice 4.23 4.20 0.03 Pipe 0.00 1.00 Side Arts Mount [SO 305- C None 0.000 237.00 No Ice 2.64 2.64 0.09 3] (3) DB848H105ESXw/ A From Leg 4.00 0.000 224.00 No Ice 7.43 10.49 0.06 Mount Pipe 0.00 1.00 (3) DB878H120ESXw/ C From Leg 4.00 0.000 224.00 No Ice 11.70 8.16 0.05 Mount Pipe 0.00 1.00 Sector Mount [SM 409-1] A None 0.000 224.00 No Ice 8.76 11.22 0.34 Sector Mount [SM 409-1] C None 0.000 224.00 No Ice 8.76 11.22 0.34 SBNHH-1D65C w/ Mount A From Leg 4.00 0.000 217.00 No Ice 5.56 4.47 0.08 Pipe 0.00 0.00 SBNHH-1D65C w/ Mount B From Leg 4.00 0.000 217.00 No Ice 5.56 4.47 0.08 Pipe 0.00 0.00 SBNHH-1D65C wi Mount C From Leg 4.00 0.000 217.00 No Ice 5.56 4.47 0.08 Pipe 0.00 0.00 (2) CMA-BDHH/6520/EO-8 A From Leg 4.00 0.000 217.00 No Ice 9.05 3.58 0.06 0.00 0.00 CMA-BDHH/6520/EO-8 B From Leg 4.00 0.000 217.00 No Ice 9.05 3.58 0.06 ,(2) 0.00 0.00 (2) CMA-BDHH/6520/EO-8 C From Leg 4.00 0.000 217.00 No ice 9.05 3.58 0.06 0.00 0.00 FRIG A From Leg 4.00 - 0.000 217.00 No Ice 2.39 0.97 0.06 0.00 0.00 FRIG B From Leg ' 4.00 0.000 217.00 No Ice 2.39 0.97 0.06 0.00 0.00 FRIG C From Leg 4.00 0.000 217.00 No Ice 2.39 0.97 0.08 0.00 0.00 RNSNDC-7771-PF-48 A From Leg 4.00 0.000 217.00 No Ice 3.20 1.03 0.01 0.00 0.00 RNSNDC-7771-PF-48 C From Leg 4.00 0.000 217.00 No Ice 3.20 1.03 0.01 0.00 0.00 (2) FXFB A From Leg 4.00 0.000 217.00 No Ice 3.54 1.02 0.06 0.00 0.00 (2) FXFB B From Leg 4.00 0.000 217.00 No Ice 3.54 1.02 0.06 0.00 0.00 (2) FXFB C From Leg 4.00 0.000 217.00 No Ice 3.54 1.02 0.06 0.00 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CCI BU No 813700 Project Number 37519-0281.002.8700, Order 475132, Revision 4 Page 19 Weight Description Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert. It tt ft2 ttz K ft ° it 0.00 Sector Mount [SM 404-3] C None 0.000 217.00-�, No Ice 20.47 20.47 0.92 TTTT65AP-lXR w/ Mount A From Leg 4.00 0.000 207.00 V No Ice 6.98 4.47 0.05 Pipe 0.00 3.00 (2) RRUS 31 B25 A From Leg 4.00 0.000 207.00 No Ice 1.62 1.28 0.06 0.00 3.00 RRUS 82 W/SOLAR A From Leg 4.00 0.000 207.00 No Ice 2.98 1.43 0.06 SHIELD 0.00 3.00 RRUS-11 80OMHZ A From Leg 4.00 0.000 207.00 No Ice 2.52 1.30 0.05 0.00 3.60 (2) ACU-A20-N A From Leg 4.00 0.000 207.00 No Ice 0.07 0.12 0.00 0.00 3.00 APXV9ERR18-C-A20 w/ A From Leg 4.00 0.000 207.00 No Ice 8.26 7.47 0.09 Mount Pipe 0.00 3.00 HPA33R-CS4AA-K1 w/ B From Leg 4.00 0.000 207.00 No Ice 7.47 4.93 0.07 Mount Pipe 0.00 3.00 RRUS 31 B25 B From Leg 4.00 0.000 207.00 No Ice 1.62 1.28 0.06 0.00 --- -- 3.00 RRUS 82 W/SOLAR B From Leg 4.00 0.000 207.00 No Ice 2.98 1.43 0.06 SHIELD 0.00 3.00 (2) RRUS-11 800MHZ B From Leg 4.00 0.000 207.00 No Ice 2.52 1.30 0.05 0.00 3.00 HPA33R-CS4AA-K1 w/ C From Leg 4.00 0.000 207.00 No Ice 7.47 4.93 0.07 Mount Pipe 0.00 3.00 RRUS 82 W/SOLAR C From Leg 4.00 0.000 207.00 No Ice 2.98 1.43 0.06 SHIELD 0.00 3.00 ACU-A20-N C From Leg 4.00 0.000 207.00 No Ice 0.07 0.12 0.00 0.00 3.00 Sector Mount [SM 301-1] A From Leg 2.00 0.000 207.00 No Ice 15.43 10.89 0.43 0.00 0.00 Sector Mount [SM 301-1] B From Leg 2.00 0.000 207.00 No Ice 15.43 10.89 0.43 0.00 0.00 Sector Mount [SM 502-1] C From Leg 2.00 0.000 207.00 No Ice 15.35 14.00 0.56 0.00 _ 0.00 (3) SBNHH-1 D85C w/ C From Leg 4.00 0.000 195.00 No Ice 5.56 4.47 0.08 Mount Pipe 0.00 5.00 RRUS 32 C From Leg 4.00 0.000 195.00 No Ice 2.86 1.78 0.06 0.00 5.00 RRUS 4449 B51B12 C From Leg 4.00 0.000 195.00 No Ice 1.97 1.41 0.07 0.00 5.00 RRUS 8843 13211366A C From Leg 4.00 0.000 195.00 No Ice 1.64 1.35 0.07 0.00 5.00 DC6-48-60-18-8F C From Leg 4.00 0.000 195.00 No Ice 1.21 1.21 0.03 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No 813700 Project Number 37519-0291.002.8700, Order 475132, Revision 4 Page 20 Description weight Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert ft it ft2 RZ K ft " ft 0.00 5.00 PVFM1233-96 Sector C From Leg 2.00 0.000 195.00 No Ice 15.35 14.00 0.56 ' Frame 0.00 0.00 ""TBR..... (3) DB848H105ESXw/ B From Leg 4.00 0.000 178.00 No Ice 7.43 10.49 0.06 Mount Pipe. 0.00 2.00 Sector Mount ISM 409-11 B None 0.000 178.00 No Ice 8.76 11.22 0.34 (2) DC6-48-60-18-BF B From Leg 4.00 0.000 160.00 No Ice 1.21 1.21 0.03 0.00 0.00 RRUS 32 A From Leg 4.00 0.000 160.00 No Ice 2.86 1.78 0.06 0.00 0.00 RRUS 4449 135/1312 A From Leg 4.00 0.000 160.00 No Ice 1.97 1.41 0.07 0.00 0.00 RRUS 8843 B2lB66A A From Leg 4.00 0.000 160.00 No Ice 1.64 1.35 0.07 0.00 0.00 (3) 80010966K w/ Mount A From Leg 4.00 0.000 160.00 No Ice 17.60 9.64 0.15 Pipe 0.00 0.00 RRUS 32 B From Leg 4.00 0.000 160.00 No Ice 2.86 1.78 0.06 0.00 0.00 RRUS 4449 135/812 B From Leg 4.00 0.000 160.00 No Ice 1.97 1 Al 0.07 0.00 0.00 RRUS 8843 82I666A B From Leg 4.00 0.000 160.00 No Ice 1.64 1.35 0.07 0.00 0.00 (3) 80010966K w/ Mount B From Leg 4.00 0.000 160.00 No Ice 17.60 .9.64 0.15 Pipe 0.00 0.00 OC6-48-60-18-BF A From Leg 4.00 0.000 160.00 No Ice 1.21 1.21 0.03 0.00 0.00 - PVFM12-3-3-96 Sector A From Leg 1.00 0.000 160.00 No Ice 13.12 10.18 0.54 Frame 0.00 ` 0.00 PVFM12-3-3-96 Sector S From Leg 1.00 0.000 160.00 No Ice 13.12 10.18 0.54 Frame 0.00 0.00 Pipe Mount [PM 601-1] A From Leg 0.00 0.000 128.00 No Ice 3.00 0.90 0.07 0.00 0.00 Pipe Mount [PM 601-1] C From Leg 0.50 0.000 120.00 No Ice 3.00 0.90 0.07 0.00 0.00 FIBEAIR 1500HP C From Leg 1.00 0.000 120.00 No Ice 0.97 1.74 0.02 0.00 0.00 tnxTower Report - version 8.0.5.0 May 1, 2019 250 Ft Self Support Tower Structural Analysis CC/ BU No 813700 Project Number 37519-0281.002.8700, Order475132, Revision 4 Page 21 Dishes. Weight Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture or Type Type Horz Adjustment Beam Diameter Area Leg Lateral Moth Vert It ft ft ft2 K SPD2-5.8 A Paraboloid From 1.00 -70.000 128.00 2.00 No Ice 3.14 0.02 w/Radome Leg 0.00 0.00 HPX6-59-P3AIK C Paraboloid From 1.00 -34.000 120.00 6.46 No Ice 32.76 0.32 w/Shroud (HP) Leg 0.00 0.00 Load: -Combinations comb. Description No. 2 1.2 Dead+1.0 Wind 0 deg - No Ice 3 0.9 Dead+1.0 Wind 0 deg' No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice - 6 1.2 Dead+1.0 Wind 60 deg - No Ice 7 0.9 Dead+1.0 Wind 60 deg - No Ice 8 1.2 Dead+1.0 Wind 90 deg - No Ice __9 _ 0.9Dead+'I.0 Wind 90 deg_No Ice_ 10 1.2 Dead+1.0 Wind 120 deg - No Ice 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice 14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice _ 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg - Service 28 Dead+Wind 60 deg - Service 29 Dead+Wind 90 deg - Service 30 Dead+Wind 120 deg -Service 31 Dead+Wind 150 deg - Service 32 Dead+Wind 180 deg. - Service 33 Dead+Wind 210 deg - Service 34 Dead+Wind 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+Wind 330 deg - Service .. Maximum Tower Deflections -.Service Wind-, . I I I 17 Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° T1 250 - 240 3.69 30 0.111 0.030 T2 240 - 220 3.46 30 0.111 0.030 T3 220 - 200 2.99 30 0.109 0.029 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 Section Elevation Horz Gov. Tilt Twist No. Deflection Load T4 200 - 186.667 2.53 30 0.105 0.028 T5 186.667 - 180 2.23 26 0.100 0.026 T6 180 - 160 2.09 26 0.098 0.025 T7 160 - 140 1.68 26 0.088 0.022 T8 140 - 120 1.31 26 0.077 0.021 T9 120 - 100 0.98 26 0.066 0.018 T10 100 - 80 0.69 26 0.055 0.014 T11 80 - 60 0.46 26 0.044 0.012 T12 60 - 40 0.28 26 0.032 0.009 T13 40 - 20 0.14 26 0.021 0.005 T14 20 - 0 0.04 26 0.010 0.003 May 1, 2019 CCI BU No 813700 Page 22 Critical Deflectionsand Radius of Curvature -'Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature 250.00 Beacon 30 3.69 0.111 0.030 Inf 237.00 932DG33T2A-M w/ Mount Pipe 30 3.39 0.111 0.030 Inf 224.00 (3) DB848H105ESX w/ Mount 30 3.08 0.110 0.029 Inf Pipe 217.00 SBNHH-1 D65C w/ Mount Pipe 30 2.92 0.109 0.029 Inf 207.00 TTTT65AP-1XR w/ Mount Pipe 30 2.69 0.107 0.029 628701 195.00 (3) SBNHH-1 D85C w/ Mount 30 2.41 0.103 0.027 134902 Pipe 178.00 (3) DS848H105ESXw/ Mount 26 2.05 0.097 0.025 313356 Pipe 160.00 (2) DC6A8-60-18AF 26 1.68 0.088 0.022 126694 128.00 SPD2-5.8 26 1.10 0.070 0.019 116344 125.00 Obstruction light 26 1.06 0.069 0.019 126871 120.00 HPX6-59-P3AIK 26 0.98 0.066 0.018 137B72 Maximum Tower Deflections - Design Wind ._ _ Section Elevation Horz Gov. Tilt Twist No. Deflection Load T1 250 - 240 24.28 10 0.731 0.193 T2 240 - 220 22.74 10 0.730 0.193 T3 220 - 200 19.66 10 0.719 0.191 T4 200 - 186.667 16.60 10 0.688 0.182 T5 186.667 - 180 14.62 10 0.660 0.167 T6 180 - 160 13.69 10 0.642 0.161 T7 160 - 140 10.99 10 0.57B 0.142 T8 140 - 120 8.52 10 0.507 0.133 T9 120 - 100 6.38 2 0.433 0.118 T10 100 - 80 4.50 2 0.359 0.093 T'l l 80 - 60 2.99 2 0.286 0.075 T12 60 - 40 1.80 2 0.208 0.057 T13 40 - 20 0.89 2 0.135 0.036 T14 20 - 0 0.28 2 0.065 0.018 Critical Deflections and Radius of Curvature- Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 23 Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature It Comb. in it 250.00 Beacon 10 24.28 0.731 0.193 751640 237.00 932DG33T2A-M w/ Mount Pipe 10 22.28 0.729 0.193 467264 224.00 (3) DB848H105ESX w/ Mount 10 20.28 0.722 0.191 525820 Pipe 217.00 SBNHH-1 D65C w/ Mount Pipe 10 19.20 0,715 0.190 222580 207.00 TTTT65AP-1XR w/ Mount Pipe 10 17.67 0.700 0.187 99376 195.00 (3) SBNHH-1 D85C w/ Mount 10 15.85 0.679 0.176 21479 Pipe 178.00 (3) DB848H105ESX w/ Mount 10 13.41 0.636 0.160 50996 Pipe 160.00 (2) DC6-48-60-18-BF 10 10.99 0.578 0.142 19579 128.00 SPD2-5.8 2 7.20 0.463 0.126 17623 125.00 Obstruction light 2 6.89 0.452 0.123 19153 120.00 HPX6-59-P3A/K 2 6.38 0.433 0.118 20947 " Bolt De'si `n Data, Criteria Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable No. Type Grade Of Load Load Load Ratio @ in Bolts per Bolt per Bolt Allowable K K T1 250 Leg A325N 0.625 4 0.29 20.34 0014 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 0.38 6.79 0.057 ✓ 1.05 Member Block Shear Top Girt A325N 0.625 1 -0.10- 7.88 / Y 1.05 - Member Block 0.013 Shear T2 240 Leg A325N 0.875 6 2.38 41.56 0.057 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 2.20 8.31 0.265 ✓ 1.05 Member Block Shear T3 220 Leg A325N 1.000 6 9.47 54.52 ♦ 0174 Y 1.05 Bolt Tension Diagonal A325N 0.625 2 4.82 11.09 ✓ 1.05 Member Block 0.435 Shear T4 200 Diagonal A325N 0.625 2 5.75 11.09 1.05 Member Block 0.519 Shear T5 186.667 Leg A325N 1.250 6 19.07 87.22 0219 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 6.00 22.17 0.271 // 1.05 Member Block Shear T6 180 Leg A325N 1.250 6 28.09 87.22 1.05 Bolt Tension 0322 t,/ Diagonal A325N 0.625 2 7.20 15.61 1.05 Member Block 0.461 �/ Shear Secondary A325N 0.625 1 3.44 9.91 ✓ 1.05 Member Block Horizontal 0.347 Shear T7 160 Leg A325N 1.250 6 39.27 87.22 0.450 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 8.91 15.61 1.05 Member Block 0.571 1/ Shear Secondary A325N 0.625 1 4.69 10.93 ✓ 1.05 Member Block Horizontal 0.429 Shear T8 140 Leg A325N 1.375 6 50.72 103.94 04881,/ 1.05 Bolt Tension Diagonal A325N 0.625 2 10.19 16.63 ✓ 1.05 Member Block 0.613 Shear Secondary A325N 0.625 1 6.02 10.93 ✓ 1.05 Member Block Horizontal 0.551 Shear T9 120 Leg A325N 1.500 6 62.28 126.47 0492 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 12.36 16.63 0.743 ✓ 1.05 Member Block Shear Secondary A325N 0.625 1 7.39 13.81 0.535 1.05 Bolt Shear Horizontal T10 100 Leg A325N 1.500 6 70.36 126.47 0.556 ✓ 1.05 Bolt Tension Diagonal A325N 0.625 2 17.99 27.61 0.651 ✓ 1.05 Bolt Shear tnxTower Report - version 8.0.5.0 U U C U C U U C O {YJ o `m o 4 0 0 N c t m N c m N m N N L m N t anto d N o m mN aEim aEiN o m aim wN m m m a m m N m m m m m m m m N O O O O O O O O O O O O O J V f0 V N tO f00 Lm0 n (NO Q G O O O O O O O O O O O A m m m No m io 0°f o Y ai fO r< of o of ai r N r n N N N N N N t�0 m m n f0 O N N a r J m Y m .^- m ONi m 4 N a N 10 O N m O m m O m m m m N O N N m N N h N N N N C m N m m A m m A m m m m 0 Z Z Z Z Z Z Z Z Z Z Z Z m m m 10 b 10 m m m m N m M m m m m m m m �Nn a a a cNi a �Nn a s a a a a a s �ppoN y o o+ o m o pNc m o o 0 0 {� C N C J N "O J N c N C x o x m x m x a x d N M V }6 iN SM �i Prl�6 S6 S��1�1n yn a�1 0 0 0 0 0 0 6 0 6 0 a, 0 0 0 6 0 6 0 m o pap f00 q R N q IR m n M d y< m m m O N aN} fND 'N t00 O IQ OJ ' O M OMi N t�l N m N M f� M v LO O N m A m m O O O mo O o O o O Mo O vo O rno O mo O �o O �o O mo O ra m ti O Y �Y �Y rnY mY mY mY �nY �iy 0Y vY oY vY vY v C O �y o ro m m m m 6 6 6 0 6 0 0 0 ui so re 6 m m m m 6 m m m 0 vi C o M M m m M M M m M M M M M tm m N N N N N N N N N V Q tm d a H O O O c 0 m N m J N N N ry O O m O O O O O O O N a 111 N N ryO N � � N C N 3 2 HP F F F F V r r y F- x 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 25 Section Elevation Size L L KUr A P„ OP„ Ratio No. P. R R It in2 K K op„ P„ / op, controls Diagonal Design, Data Com ression ' y Ratio Section Elevation Size L L. KI1r A P„ ¢P No. P R R R if? K K OP„ T1 250 - 240 L 2 x 2 x 3/16 7.81 3.80 115.6 0.715 -0.88 14.92 0.0591 K=1.00 V T2 240 - 220 L 3 x 3 x 3/16 10.16 5.14 103.4 1.090 -4.67 25.59 0.1821 K=1.00 V T3 220 -200 L 3 x 3 x 1/4 11.74 5.90 119.5 1.440 -10.11 28.55 0.3541 K=1.00 V T4 200 - 186.667 L 3 x 3 x 1/4 12.86 6.43 130.4 1.440 -11.76 24.25 0.485' K=1.00 V T5 186.667 - 180 2L 3 x 3 x 1/4 (3/8) 13.44 6.72 89.6 2.880 -12.24 76.23 0.1611 K=1.00 21-'a' > 38.495 in - 83 T6 180 - 160 2L 2.5 x 2.5 x 3116 (1/2) 16.80 8.51 131.1 1.805 -15.38 30.03 0.512' K=1.00 t/ T7 160 - 140 2L 2.5 z 2.5 x 3/16 (1/2)' - 18.45 9.31- 143.6 - 1.805 -18.3B- 25.06 - - 0.7331 K=1.00 V T8 140 - 120 2L 3 x 3 x 3/16 (1/2) 20.16 10.15 129.7 2.180 -21.09 36.03 0.585, K=1.00 V T9 120 - 100 2L 3 x 3 x 3/16 (1/2) 21.92 11.02 140.7 2.180 -24.97 31.50 0.7931 K=1.00 V T10 100 - 80 2L 3 x 3 x 5116 (112) 14.87 14.59 '138.3 3.555 -35.98 52.65 0.683' K=1.00 // T11 80 - 60 2L 3 x 3 x 5/16 (1/2) 15.62 15.35 145.9 3.555 -35.49 47.31 0.750' K=1.00 V T12 60 -40 2L 3 x 3 x 1/4 (1/2) 16.40 8.20 105.8 2.875 -38.65 67.08 0.5761 K=1.00 V T13 40 - 20 2L 3 x 3 x 5116 (112) 17.21 8.60 112.0 3.555 -38.24 77AS 0.4941 K=1.00 6/ T14 20 - 0 2L 3 x 3 x 5116 (1/2) 18.03 9.02 117.4 3.555 -40.28 72.53 0.555' K=1.00 1 P„ / oP„ controls HorizontafDesign Data (Compression),, Section Elevation Size L L„ K11r A P„ ¢P„ Ratio No. P. R R R in' K K 4P7 T10 100 - 80 2L 2.5 x 2.5 x 3/16 (1/2) 21.00 10.29 158.7 1.805 -8.37 20.51 0.408' K=1.00 6/ T11 80 - 60 2L 2.5 x 2.5 x 3116 (112) 23.00 11.29 174.1 1.805 -9.77 17.04 0.573' K=1.00 V T12 60 - 40 2L 2.5 x 2.5 x 3/16 (1/2) 25.00 12.28 189.4 1.805 -11.06 14.40 0.768' K=1.00 6/ 2L'a' > 70.285 in - 262 T13 40 - 20 2L 3 x 3 x 3/16 (1/2) 27.00 13.27 170.2 2.100 -12.42 21.06 0.5901 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 26 Section Elevation Size L L„ K11r A P„ op„ Ratio No. P ft ft ft in' K K .IMP_ 2L'a' > 75.820 in - 326 T14 20-0 2L 3 x 3 x 3116 (1/2) 2L'a' > 81 A74 in - 383 1 P v / QP„ Controls 29.00 14.26 183.3 2.180 -13.75 18.23 0.754 K=1.00 6/ Secondary Horizontal Design Data (Compression) Section Elevation Size L L„ KI(r A P„ OP„ Ratio No. P It it ft iR2 K K OPT T6 180 - 160 L 2.5 x 2.5 x 3/16 13.48 6.57 159.4 0.902 -3.44 10.16 0.3381 K=1.00 V T7 160 - 140 L 3 x 3 x 3/16 15.48 7.56 152.3 1.090 -4.69 13.45 0.3481 K=1.00 V T8 140 - 120 L 3 x 3 x 3116 17.49 8.56 172.3 1.090 -6.02 10.51 0.573 1 K=1.00 V T9 120 - 100 L 3 x 3 x 1/4 19.49 9.55 193.5 1.440 -7.39 11.01 0.6711 K=1.00 `/ 1 P u / op, controls Top Girt Design Data (Compression) Ratio Section Elevation Size L L„ KI1r A P. OP„ No. I P ft ft ft in2 K K OP„ T1 250 - 240 L 2 x 2 x 3116 6.00 5.83 177.7 0.715 -0.12 6.48 0.0191 K=1.00 `/ 1 P u / ¢P„ controls Redundant Horizontal 1 Design Data (Compression Section Elevation Size L L„ KI/r A P. OP„ Ratio No. P ft If R in2 K K OP„ T10 100 - 80 2L 2 x 2 x 3116 (1/2) 5.25 5.04 98.0 1.430 -8.37 35.81 0.2341 K=1.00 2L'a' > 28.945 in - 177 T11 80 - 60 2L 2 x 2 x 3116 (1/2) 5.75 5.54 107.7 1.430 -9.77 32.67 0.2991 K=1.00 2La'>31.815 in-222 T12 60 -40 2L 2 x 2 x 3116 (1/2) 6.25 6.03 117.2 1.430 -11.06 29.22 0.3781 K=1.00 d/ 2L'a' > 34.626 in - 267 T13 40 - 20 2L 2 x 2 x 3116 (1/2) 6.75 6.52 126.8 1.430 -12.42 25.47 0.4881 K=1.00 2L'a' > 37.437 in - 331 T14 20 - 0 2L 2 x 2 x 3116 (1/2) 7.25 7.01 136.3 1.430 -13.75 22.03 0.6241 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 27 Section Elevation Size L L. KUr A, P. OP„ Ratio No. P. ft ft It irk K_ K-_-4R- 2L'a' > 40.247 in - 388 1 P � / op, controls Redundant Diagonal (1), Design Data Coni cession Section Elevation Size L L. KI1r A P. 017n Ratio No. P It it it in2 K K 4P„ T10 100 - 80 2L 2 x 2 x 3116 (1/2) 7.43 7.14 138.8 1.430 5.93 21.24 0.2791 K=1.00 2L'a' > 40.991 in - 201 T11 80 - 60 2L 2 x 2 x 3116 (1/2) 7.81 7.53 146.4 1.430 -6.64 19.10 0.3471 K=1.00 2L'a'>43.231 in-246 T12 60 - 40 2L 2 x 2 x 3116 (1/2) 8.20 7.92 153.9 1.430 -7.26 17.28 0.4201 K=1.00 2L'a' > 45.453 in - 297 T13 40 - 20 2L 2 x 2 x 3116 (112) 8.60 8.31 161.6 1.430 -7.92 15.66 0.505, K=1.00 2L'a' > 47.734 in - 360 T14 20 - 0 2L 2.5 x 2.5 x 3/16 (1/2) _ 9.02 8.72 136:0 1.805 -8.55 27.27 _ 0.3131 K=1.00 2L'a' > 49.908 in -417 1 P / oP Controls Redundant Hi' 1 Design Data (Compression) Section Elevation Size L L. KI1r A P. op. Ratio No. P ft It ft in' K K mp- T12 60 - 40 L 2.5 x 2.5 x 3/16 6.25 6.25 151.5 0.902 -0.10 11.25 0.009, K=1.00 I/ T13 40 - 20 L 2.5 x 2.5 x 3/16 6.75 6.75 163.6 0.902 -0.09 9.64 0.0101 K=1.00 V T14 20 - 0 L 2.5 x 2.5 x 3116 7.25 7.25 175.8 0.902 -0.09 8.36 0.0111 K=1.00 9/ 1 P u / op, Controls Redundant Hip Diagonal 1 Design Data Com ression Section Elevation Size L L K11r A P. OP„ Ratio No. P it ft If ir,2 K K 4P„ T12 60 - 40 L 2.5 x 2.5 x 3/16 11.80 11.80 286.0 0.902 -0.14 3.16 0.045 1 K=1.00 KUR > 250 (C) - 315 T13 40 - 20 L 2.5 x 2.5 x 3/16 12.59 12.59 305.1 0.902 -0.12 2.T7 0.043' K=1.00 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 28 Section Elevation Size L L„ KI1r A P. OP„ Ratio No. P. ft It It /n' K K gyp" KUR > 250 (C) - 372 T14 20 - 0 L 2.5 x 2.5 x 3/16 13.38 13.38 324.5 0.902 -0.12 2.45 0.0491 K=1.00 KUR > 250 (C) - 429 I P„ / �P" controls Inner Bracing Design Data (Compression) Section Elevation Size L L. KI1r A P. ¢P„ Ratio No. P., it it it in2 K K W. T10 100 - 80 2L 2 x 2 x 3116 (3/8) 10.50 10.50 204.2 1.430 -0.03 9.81 0.003 1 K=1.00 V T11 80 - 60 2L 2 x 2 x 3116 (318) 11.50 11.50 223.7 1.430 -0.03 8.18 0.004 1 K=1.00 V T12 60 - 40 2L 2 x 2 x 3/16 (318) 12.50 12.50 243.1 1.430 -0.06 6.93 0.009 1 K=1.00 V T13 40 - 20 2L 2.5 x 2.5 x 3116 (3/8) 13.50 13.50 208.2 1.800 -0.08 11.88 0.007 1 K=1.00 V T14 20 - 0 2L 2.5 x 2.5 x 3116 (3/8) 14.50 14.50 223.6 1.800 -0.04 10.30 0.004 1 K=1.00 V 1 P„ / �P„ controls Tension Checks Leg Design Data Tension Section Elevation Size L L„ KI1r A P. OP„ Ratio No. P. it ft It in K K op" T1 250 - 240 2" solid 10.00 5.00 120.0 3.142 1.17 141.37 0.008, T2 240 - 220 3" solid 20.03 6.68 106.8 7.069 14.30 318.09 0.045 1 T3 220 - 200 3 1/2" solid 20.03 6.68 91.6 9.621 56.85 432.95 0.131 1 T4 200 - 186.667 4" solid 13.36 6.68 80.1 12.566 95.17 565.49 0.1681 T5 186.667 - 180 4" solid 6.68 6.68 80.1 12.566 114.43 565.49 0.2021 T6 180 - 160 4" solid 20.03 4.82 57.9 12.566 168.75 565.49 0.2981 T7 160 -140 4 114" solid 20.03 4.85 54.7 14.1 B6 235.84 638.38 0.3691 T8 140 - 120 4 1/2" solid 20.03 4.87 51.9 15.904 304.58 715.69 0.4261 T9 120 - 100 4 3/4" solid 20.03 4.88 49.3 17.721 374.05 797.42 0.4691 T10 100 - 80 5" solid 20.03 5.01 48.1 19.635 423.41 883.57 0.4791 tnxTower Report -version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 29 Section No. Elevation it Size L ft L„ ft Kdr A /rr2 P„ K op. K Ratio P. OP" T11 80 - 60 5" solid 20.03 5.01 48.1 19.635 491.75 883.57 0.5571 T12 60 - 40 5 114" solid 20.03 5.01 45.8 21.647 555AO 974.14 0.5701 T13 40 - 20 5 1/2" solid 20.03 5.01 43.7 23.758 620.80 1069.12 0.581 1 T14 20 - 0 5 3/4" solid 20.03 5.01 41.8 25.967 680.24 1168.53 0.5821 1 P u / ¢P„ controls = Diagonal onal -Design Data Tension '- Ratio Section Elevation Size L L KUr A P. OP" No. P. ft ft ft W K K OP" T1 250 - 240 ' L 2 x 2 x 3116 7.81 3.80 73.8 0.431 0.77 18.74 0.0411 f✓ T2 240 - 220 L 3 x 3 x 3/16 10.16 5.14 65.6 0.712 4.41 30.97 0.1421 T3 220 - 200 L 3 x 3 x 1/4 11.74 5.90 76.1 0.939 9.64 40.86 0.236 1 T4 200 - 186.667 L 3-x 3x1/4 12.86 6A3 83.0 0.939 11.51 40.86 - 0282 1 I✓ T5 186.667 - 180 2L 3 x 3 x 1/4 (3/8) 13.44 6.72 86.7 1.879 12.01 81.73 0.1471 2L'a' > 38.495 In - 83 T6 180 - 160 2L 2.5 x 2.5 x 3116 (112) 16.80 8.51 131.1 1.143 14.39 49.70 0.2901 T7 160 - 140 2L 2.5 x 2.5 x 3116 (1/2) 18.45 9.31 143.6 1.143 17.82 49.70 0.3581 T8 140 - 120 2L 3 x 3 x 3/16 (1/2) 20.16 10.15 129.7 1.424 20.38 61.94 0.3291 T9 120 - 100 2L 3 x 3 x 3/16 (1/2) 21.92 11.02 140.7 1.424 24.72 61.94 0.3991 T10 100 - 80 2L 3 x 3 x 5/16 (1/2) 14.87 14.59 121.0 2.314 32.97 100.68 0.3271 T11 80 - 60 2L 3 x 3 x 5/16 (1/2) 14.87 14.60 121.1 2.314 34.31 100.68 0.341 1 T12 60 - 40 2L 3 x 3 x 114 (1/2) 16.40 8.20 105.8 1.875 35.22 81.56 0.432 1 T13 40 - 20 2L 3 x 3 x 5/16 (1/2) 16.40 8.20 106.8 2.314 36.71 100.68 0.3651 T14 20 - 0 2L 3 x 3 x 5/16 (1/2) 17.21 8.60 112.0 2.314 36.53 100.68 0.3631 I✓ 1 P" / oP" controls Horizontal'Desi' n Data Tension Ratio Section Elevation Size L L. K11r A P„ OP" No. P. _ it It ft in' K K mP" T10 100 - 80 2L 2.5 x 2.5 x 3/16 (1/2) 21.00 10.29 158.7 1.143 8.37 49.70 0.1681 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CC/ BU No 813700 Page 30 Section Elevation Size L L„ K11r A P. OP„ Ratio No. P ft It ft in, K K 6p- T11 80 - 60 T12 60-40 T13 40-20 T14 20-0 1 P � / QP„ controls 2L 2.5 x 2.5 x 3116 (112) 23.00 2L 2.5 x 2.5 x 3/16 (112) 25.00 2L'a' > 70.285 in - 269 2L 3 x 3 x 3116(1/2) 27.00 2L'a' > 75.820 in - 326 2L 3 x 3 x 3116(1/2) 29.00 2L'a' > 81.474 In - 383 11.29 174.1 1.143 9.77 49.70 0.197' 11/ 12.28 189.4 1.143 11.06 49.70 0.222' 13.27 169.5 1.424 12.42 61.94 ' 0.20011 Y 14.26 182.2 1.424 13.75 61.94 0.222' f ` Secondary Horizontal Design Data Tension Section Elevation Size L L. K11r A P. ¢P„ Ratio No. 17 ft ft ft in K K hP- T6 180-160 L2.5 x 2.5 x31' T7 160-140 L 3 x 3 x3/16 TB 140-120 L3x3x3/16 T9 120-100 L3x3x1/4 1 P„ / OP„ controls V 15.48 7.56 193.4 0.712 4.69 30.97 0.151 ' V 17.49 8.56 218.7 0.712 6.02 30.97 0.194' 19.49 9.55 246.3 0.939 7.39 40.86 0.181 ' Top Girt Design Data Tension Section Elevation Size L L„ K11r A P. OP. Ratio No. P ft ft ft in K K pp„ Tt 250-240 L2x2x3/16 1 P v / OP„ controls Redundant Horizontal 1 Design Data Tension Ratio Section Elevation Size L L„ K11r A P. OP„ No. P ft ft ft in2 K K �P T10 100 - 80 21-2 x 2 x 3116 (112) 5.25 5.04 98.0 1.430 8.37 46.32 0.181, 2L 'a' > 28.945 in - 177 T11 80 - 60 2L 2 x 2 x 3116 (1/2) 5.75 5.54 107.7 1.430 9.77 46.32 0.2111 6/ tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order475132, Revision 4 May 1, 2019 CCI BU No 813700 Page 31 Section Elevation Size L L„ KI/r A P. op. Ratio No. PU it ft it ir>z K K bP- 2L'a' > 31.815 in - 22 T12 60-40 2L 2 x 2 x 3116 (1/2) 2L'a' > 34.626 in - 267 T13 40-20 2L 2 x 2 x 3/16 (1/2) 2L'a' > 37.437 in - 331 T14 20-0 2L 2 x 2 x 3116 (1/2) 2L'a' > 40.247 In - 394 1 P u / QP controls 6.25 6.03 117.2 1.430 11.06 6.75 6.52 126.8 1.430 12.42 7.25 7.01 136.3 1.430 13.75 46.32 0.239 1 46.32 0.268 1 t/ 46.32 0.297 Redundant Da onal 1 -Desi n Data (Tension), Ratio Section Elevation Size L L„ KIIr A P. OP„ No. P R it it Jr? K K 4p� T10 100 - 80 2L 2 x 2 x 3116 (112) 7.43 7.14 138.8 1.430 5.93 46.32 0.1281 2L'a'>40.991 in-201 T11 , 80 - 60 2L 2 x 2 x 3116 (1/2) 7.81 7.53 146.4 1.430 6.64 46.32 0.143 1 2L'a'>43.231 in-246 _ _ _ T12 60 - 40 2L 2 x 2 x 3/16 (1/2) 8.20 7.92 153.9 1.430 7.26 46.32 0.1571 2L'a' > 45.453 in - 300 T13 40 - 20 2L 2 x 2 x 3/16 (1/2) 8.60 8.31 161.6 1.430 7.92 46.32 0.171 1 2L'a' > 47.734 in - 365 T14 20 - 0 2L 2.5 x 2.5 x 3/16 (1/2) 9.02 8.72 134.5 1.805 8.55 58.47 0.1461 2L'a' > 49.908 in - 417 1 P / oP Controls Redundant Hi` 1 Design Data Tension Ratio Section Elevation Size L L„ K11r A P. ¢P„ No. P ft ft it iR2 K K op� T12 60 - 40 L 2.5 x 2.5 x 3/16 6.25 6.25 96.4 0.902 0.06 29.22 0.002 1 T13 40 - 20 L 2.5 x 2.5 x 3/16 6.75 6.75 104.1 0.902 0.05 29.22 0.0021 t✓ T14 20 - 0 L 2.5 x 2.5 x 3/16 7.25 7.25 111.8 0.902 0.04 29.22 0.0021 1 P u / op, controls Redundant Hip Dia tonal .1 Desi n`:Data Tension tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 47513Z Revision 4 May 1, 2019 CC/ BU No 813700 Page 32 Section Elevation Size L L. KUr A P. Op" Ratio No. P. it 1t it M12 K K Op" T12 60 - 40 L 2.5 x 2.5 x 3116 12.06 12.06 186.0 0.902 0.15 29.22 0.0051 T13 40 - 20 L 2.5 x 2.5 x 3116 12.85 12.85 198.2 0.902 0.13 29.22 0.004' T14 20 - 0 L 2.5 x 2.5 x 3/16 13.65 13.65 210.6 0.902 0.12 29.22 0.0041 ' P v l OP. Controls Inner Bracing Design Data Tension Ratio Section Elevation Size L L" Kt(r A P. OP„ No. P. it ft It ir2 K K 4p" T10 100 - 80 2L 2 x 2 x 3/16 (3/8) 10.50 10.50 204.2 1.430 0.00 46.33 0.0001 ✓ Tl l 80 - 60 2L 2 x 2 x 3116 (3/8) 11.50 11.50 223.7 1.430 0.00 46.33 0.000' T12 60 - 40 2L 2 x 2 x 3/16 (3/8) 12.50 12.50 243.1 1.430 0.03 46.33 0.001 ' T13 40 - 20 2L 2.5 x 2.5 x 3116 (318) 13.50 13.50 208.2 1.800 0.02 58.32 0.000, ✓ T14 20 - 0 21- 2.5 x 2.5 x 3/16 (318) 14.50 14.50 223.6 1.800 0.02 58.32 0.0001 I P„ / OP" Controls Section Capacity Table Section Elevation Component Size Critical P oP� % Pass No. It Type Element K K Capacity Fail T1 250 - 240 Leg 2" solid 2 -1.84 51.75 3.6 Pass T2 240 - 220 Leg 3" solid 20 -18.51 144.96 12.8 Pass T3 220 - 200 Leg 3 1/2" solid 41 -68.39 246.21 27.8 Pass T4 200 - 186.667 Leg 4" solid 61 -110.81 371.28 29.8 Pass T5 186.667 -180 Leg 4" solid 76 -132.10 371.28 35.6 Pass T6 180 - 160 Leg 4" solid 86 -193.01 446.95 43.2 Pass T7 160 - 140 Leg 4 1/4" solid 107 -270.24 522.41 51.7 Pass T8 140-120 Leg 41/2"solid 128 347.23 602.61 57.6 Pass T9 120 - 100 Leg 4 3/4" solid 149 -425.94 687.57 61.9 Pass T10 100 - 80 Leg 5' solid 170 -482.62 783.48 61.6 Pass Tl l 80 - 60 Leg 5" solid 215 -563.25 783.48 71.9 Pass T12 60-40 Leg 51/4"solid 260 -637.60 877.46 72.7 Pass T13 40 - 20 Leg 5 1/2" solid 318 -716.41 976.23 73.4 Pass T14 20 - 0 Leg 5 3/4" solid 375 -792.65 1079.75 73.4 Pass TI 250 - 240 Diagonal L 2 x 2 x 3116 7 -0.88 15.66 5.6 Pass T2 240 - 220 Diagonal L 3 x 3 x 3116 27 -4.67 26.87 17.4 Pass 25.2 (b) T3 220 - 200 Diagonal L 3 x 3 x 114 48 -10.11 29.97 33.7 Pass 41.4 (b) T4 200 - 186.667 Diagonal L 3 x 3 x 114 68 -11.76 25.46 46.2 Pass 49.4 (b) T5 186.667 - 180 Diagonal 2L 3 x 3 x 1/4 (3/8) 83 -12.24 83.04 15.3 Pass 25.8 (b) T6 180 - 160 Diagonal 2L 2.5 x 2.5 x 3/16 (1/2) 92 -15.38 31.54 48.8 Pass T7 160 - 140 Diagonal 2L 2.5 x 2.5 x 3116 (1/2) ill -18.38 26.31 69.8 Pass T8 140 - 120 Diagonal 2L 3 x 3 x 3/16 (1/2) 134 -21.09 37.83 55.8 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 CCI BU No 813700 Page 33 Section No. Elevation It Component Type size Critical Element P K 017 „ K % Capacity Pass Fall 58.4 (b) T9 120 - 100 Diagonal 2L 3 x 3 x 3116 (1/2) 155 -24.97 33.07 75.5 Pass T10 100 - 80 Diagonal 2L 3 x 3 x 5/16 (112) 187 -35.98 55.28 65.1 Pass T11 80 - 60 Diagonal 21. 3 x 3 x 5/16 (1/2) 232 -35.49 49.67 71.4 Pass T12 60 -40 Diagonal 2L 3 x 3 x 1/4 (1/2) 279 -38.65 70.43 54.9 Pass 75.6 (b) T13 40 - 20 Diagonal 2L 3 x 3 x 5/16 (1/2) 336 -38.24 81.35 47.0 Pass 66.0 (b) T14 20 - 0 Diagonal 2L 3 x 3 x 5/16 (1/2) 393 -40.28 76.16 52.9' Pass 69.5 (b) T10 100 - 80 Horizontal 2L 2.5 x 2.5 x 3116 (1/2) 172 -8.37 21.54 38.9 Pass 40.2 (b) T11 80 - 60 Horizontal 21. 2.5 x 2.5 x 3116 (1/2) 217 -9.77 17.89 54.6 Pass T12 60 - 40 Horizontal 21. 2.5 x 2.5 x 3/16 (1/2) 262 -11.06 15.12 73.1 Pass T13 40 - 20 Horizontal 2L 3 x 3 x 3/16 (1/2) 326 -12.42 22.12 56.2 Pass T14 20 - 0 Horizontal 2L 3 x 3 x 3/16 (1/2) 392 -13.75 19.14 71.8 Pass T6 180 - 160 Secondary L 2.5 x 2.5 x 3/16 94 -3.44 10.67 32.2 Pass Horizontal 33.0 (b) T7 160 - 140 Secondary L 3 x 3 x 3/16 115 -4.69 14.12 33.2 Pass Horizontal 40.8 (b) T8 140 - 120 Secondary L 3 x 3 x 3/16 136 -6.02 11.04 54.5 Pass Horizontal T9 120 - 100 Secondary L 3 x 3 x 1/4 157 -7.39 11.56 63.9 Pass Horizontal T1 250 - 240 Top Girt L 2 x 2 x 3/16 5 -0.12 6.81 1.8 Pass T10 100 - 80 Redund Horz 1 2L 2 x 2 x 3116 (1/2) 181 -8.37 37.60 22.3 Pass Bracing T11 80 - 60 Redund Horz 1 2L 2 x 2 x 3116 (1/2) 222 -9.77 34.30 28.5 Pass Bracing T12 60 - 40 Redund Horz 1 21- 2 x 2 x 3/16 (1/2) 271 -11.06 30.68 36.0 Pass Bracing - - - -- - - T13 40 - 20 Redund Horz 1 2L 2 x 2 x 3116 (1/2) 331 -12.42 26.74 46.5 Pass Bracing T14 20 - 0 Redund Horz 1 21. 2 x 2 x 3/16 (1/2) 388 -13.75 23.14 59A Pass Bracing T10 100 - 80 Redund Diag 1 21. 2 x 2 x 3116 (1/2) 204 -5.93 22.31 26.6 Pass Bracing T11 80 - 60 Redund Diag 1 2L 2 x 2 x 3/16 (1/2) 246 -6.64 20.05 33.1 Pass Bracing T12 60 -40 Redund Diag 1 2L 2 x 2 x 3/16 (1/2) 297 -7.26 18.14 40.0 Pass Bracing T13 40 - 20 Redund Diag 1 2L 2 x 2 x 3116 (112) 360 -7.92 16.45 48.1 Pass Bracing T14 20 - 0 Redund Diag 1 2L 2.5 x 2.5 x 3/16 (1/2) 422 -8.55 28.64 29.8 Pass Bracing T12 60-40 Redund Hip L2.5 x2.5 x 3116 314 -0.10 11.81 0.9 Pass Bracing T13 40 - 20 Redund Hip 1 L 2.5 x 2.5 x 3/16 342 -0.09 10.12 0.9 Pass Bracing T14 20 - 0 Redund Hip 1 L 2.5 x 2.5 x 3/16 428 -0.09 8.78 1.0 Pass Bracing T12 60 - 40 Redund Hip L 2.5 x 2.5 x 3/16 315 -0.14 3.31 4.3 Pass Diagonal 1 Bracing T13 40 - 20 Redund Hip L 2.5 x 2.5 x 3/16 372 -0.12 2.91 4.1 Pass Diagonal 1 Bracing T14 20 - 0 Redund Hip L 2.5 x 2.5 x 3/16 429 -0.12 2.57 4.7 Pass Diagonal 1 Bracing T10 100 - 80 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 195 -0.03 10.31 0.3 Pass T11 BO - 60 Inner Bracing 2L 2 x 2 x 3116 (3/8) 240 -0.03 8.59 0.4 Pass T12 60 - 40 Inner Bracing 2L 2 x 2 x 3/16 (3/8) 290 -0.06 7.27 0.8 Pass T13 40 - 20 Inner Bracing 2L 2.5 x 2.5 x 3/16 (3/8) 347 -0.08 12.48 0.6 Pass T14 20 - 0 Inner Bracing 2L 2.5 x 2.5 x 3/16 (3/8) 404 -0.04 10.81 0.4 Pass Summary Leg (T14) 73.4 Pass Diagonal 75.6 Pass (T12) Horizontal 73.1 Pass (T12) Secondary 63.9 Pass Horizontal tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 May 1, 2019 M BU No 813700 Page 34 No. ft Type Element K K Capacity Fail (T9) Top Girt 1.8 Pass (Ti) Redund 59.4 Pass Horz 1 Bracing (T14) Redund 48.1 Pass Diag 1 Bracing (T13) Redund 1.0 Pass Hip 1 Bracing (T14) Redund 4.7 Pass Hip Diagonal 1 Bracing (T14) Inner 0.8 Pass Bracing (T12) Bolt 75.6 Pass Checks RATING = 75.6 Pass tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number 37519-0281.002.8700, Order 475132, Revision 4 APPENDIX B BASE LEVEL DRAWING May 1, 2019 CC/ BU No 813700 Page 35 tnxTower Report - version 8.0.5.0 250 Ft Self Support Tower Structural Analysis Project Number37519-0281.002.8700, Order475132, Revision 4 APPENDIX C ADDITIONAL CALCULATIONS May 1, 2019 M BU No 813700 Page 36 tnxTower Report - version 8.0.5.0 Ozophla Project Information BU # 81,876 - Site Name , Order # ` Jower Information Tower Type " Self Su ' ort . TIA-222 Rev ' '. H 0 Apply TIA-222-H Section 15.5 Applied o.d Comp. Uplift Axial k - 830.00 , - 712.00 Shear k - 96:00 85.00 ' �Anchor Rod Data Quantity: 6,. Diameter (in): ' '`.' 2.75 ° Material Grade: _ A36 Grout Considered: Yes Iar (in): °p 1.75 ,. Eta Factor, ri: 0.55 Thread Type:, N'-Included Configuration: 1. S rometrical'" Anchor . . Axial, Pu c (kips) 138.33 Shear, Vu (kips) 16.00 Moment, Mu (kip -in) - Axial Cap., Pn c (kips) 177.48 Shear Cap., 4)Vn kips 53.24 Moment Cap., ¢Mn (kip -in) - Stress Rating, 82.8% Fy=36 ksi Fu=58 ksi Not Considered, lar<=1(d) Pass CClplate - version 3.5.0 Analysis Date: 5/1/2019 UL J. FORD 0F &/COMPANY 250 E Broad St, Ste 600 * Columbus, OH 43215 Phone 614.221.6679 www.pauljford.com Tower Manufacturer's Drawing Information Manufacturer: FWT Drawing #: S98-1019-A Drawings Date: 5/15/1998 Page By Project # MRR Of 1 Date 2/14/2019 37519-0281 Reactions Original Design Modified Original Design* Current Analysis Ratio Compression (kips) 817 1102.95 830.00 0.75253 Tension (kips) 722.4 975.24 712.00 0.73008 * The original tower design was completed in accordance with TIAIEIA-222-F standard. Per section 15.6.2 of the TIA-222-H standard, the reactions from the original design shall be multiplied by 1.35 for comparison to the reactions from this analysis. vO.1 - Effective Date 2-20-14 AMa MSOM OFCNRfNeNa3lS Address: No Address at This Location Wind Results: ASCE 7 Hazards Report Standard: ASCE/SEI 7-10 Elevation: 23.53 ft (NAVD 88) Risk Category: II Latitude: 27.4833 Soil Class: D - Stiff soil Longitude:-80.567 i it C Wind Speed: 153 Vmph 10-year MRI 86 Vmph 25-year MRI 104 Vmph 50-year MRI 115 Vmph 100-year MRI 126 Vmph Data Source: ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1—CC-4, incorporating errata of March 12, 2014 Date Accessed: Tue Jan 22 2019 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is in a hurricane -prone region as defined in ASCE/SEI 7-10 Section 26.2. Glazed openings shall be protected against wind-borne debris as specified in Section 26.10.3. Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind conditions. httos•J/asGe7hazardtool.online/ Page 1 of 3 Tue Jan 22 2019 ASiE Seismic Site Soil Class: D - Stiff Soil Results: Ss : 0.059 SDs : 0.063 • S, : 0.03 Sol : 0.048 F• : 1.6 TL : 8 F, : 2.4 PGA: 0.028 SMs : 0.094 PGA M : 0.045 SM7 : 0.072 FPGA 1.6 I• 1 Seismic Design Category A Data Accessed: Tue Jan 22 2019 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2. Additional data for site -specific ground motion procedures in accordance with ASCE/SEI 7-10 Ch. 21 are available from USGS. htlpsJ/asce7hazardtooLoNine/ Page 2 of 3 Tue Jan 22 2019 ;ASCE' AWCUsocttrorovamanEM Ice Results: Ice Thickness: Concurrent Temperature: Gust Speed: Data Source: Date Accessed: 0.00 in. . it 25 F 30 mph Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8 Tue Jan 22 2019 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is' and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third parry providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE_ does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as ari endorsement, - -- affiliation, relationship, or sponsorship of such third -party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. httpsJ/asce7hazardtool.online/ Page 3 of 3 Tue Jan 22 2019