Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
COMPONENT & CLADDING WIND LOADS
Component & Cladding Wind Loads Prepared for DVT Hurricane Shutters Project: Franceschl Marble and Granite Inc Location: 7361 Commercial Or Vero Beach, FL Project ID: Date: 5/29/2019 Design Information Risk Category 2 Windspeed 160 mph Exposure C Int. Press. Cost, GCy(+/-) 0.18 a 8.00 feet Calculations by Seaside Engineers File Copy Certificate of Authorization No. 32048 426560th Court Vero Beach, Florida 3296 i (722) 202-80M '`�- - �a _-wm SCANNED ff�O ®R BY St. Lucie County CODE COMPL NCE ST. LUCIE/Cpp��OUNTY ®®CC These pressures are calculated using the Allowable Stress Design. Select the appropriate fastener size and spacing using the pre-engineered attachment schedule for the Florida Approved Product(s) used on this job. Contact Seaside Engineers Immediately if the product attachment schedule is derived on ultimate design pressures Instead of allowable stress design. Opening Description Area (sgft) Zone Florida Product Approval d or NOA Manufacturer Model Building Design Pressure (PSF) Product Design Pressure (PSF) Shutter Ni 25.7 5 FL389.2 ASSA Bertha HV Accordian 30.6 -39.5 64.0 -72.0 Shutter42 28.7 5 FL389.2 ASSA Bertha HV Accordian 30.4 .39.0 64.0 .72.0 Shutter 03 26.3 5 F1.389.2 JAM Bertha HV Accordian 30.5 -39.4 64.0 -72.0 Shutter N4 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 .39.4 64.0 -72.0 Shutter05 26.3 S FL389.2 ASSA Bertha HV Accordian 30.5 -39.4 64.0. .72.0 5hutterli6 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 -39.4 64.0 .72.0 Shutter M7 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 -39.4 64.0 -72.0 Shutterg8 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 -39.4 64.0 -72.0 Shutter7N 26.3 5 F1389.2 ASSA Bertha HV Accordian 30.5 -39.4 64.0 -72.0 Shutter#10 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 -39A 64.0 -72.0 Shutter Nll 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 -39.4 64.0 -72.0 Shutternl2 26.3 5 FL389.2 ASSA Bertha HV Accordian 30.5 --39.4 64.0 -72.0 Shutter N13 26.3 5 FL389.2 ASSA _ Bertha HV Accordan 30.5 -39.4 64.0 .72.0 Shutter N34 14.9 5 FL389.2 ASSA Bertha HV Accordian 31.7 >S.8 64.0 -72.0 ROOF: WALL: uuF Pp D K. 90q��iii .,, E 04 n �I �..• �,� Sic .••� No. 72228 • i • 1 ' '• 'I. 4/ :1� •.4OR1006 0:•' Edward K Roske, PE May 29, 2019 Franceschi Residence 7361 commercial Cir. Fort Pierce, FL 34951 Rear SHOP #14 Front Franceschi Residence 7361 Commercial Cir. Fort Pierce, FL 34951 OPENING WIDTH HEIGHT # 1 82.25" 45" # 2 46.50" 89" # 3 82.25" 45" # 4 82.25" 45" # 5 82.25" 45" # 6 82.25" 45" # 7 82.25" 45" # 8 82.25" 45" # 9 82.25" 45" # 10 82.25" 45" # 11 82.25" 45" # 12 82.25" 45" # 13 82.25" 45" # 14 46.50" 45"