Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE� r Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34981— (772) 462-1553 Certification for Design Load Compliance Project Name: Dollar General Port St. Lucie FL Project Address: 7180 U.S. Highway 1 Permit #: 1906-0472 Occupancy Type: M Construction Type: IIB • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition o Any accessory structure requiring a building permit BY o Any non-residential structure. St. Lucie County Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I x II _III _ IV Exposure Category: _B. X C _D 4. Design Wind Velocity 1! mph x ASO _LRFD End Zone Width: 70-0" ft S. Mean Roof Height 16'-0' ft Roof Pitch: 3/8" :12 Parapet: +1- 00" ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:22.16 Zone 2: 22.16 Zone 3: 22•16 Zone 4:22.16 Zone 5:44•9 Garage: WA 7. Design Loads: Floor: 125 PSF Roof/Dead: 2.0 PSF Roof/Live: 20 Balcony: wA PSF Dock: WA PSF Deck: NSA PSF Stairs: NIA PSF Fence: NSA PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not: Moment resisting steel frame. Engineered metal building. 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: `A Print Name Cart # & Co. Cert Auth. n/��t V 11,1 Signature, Date, and teal Company Name & Address Revised 07/25/2014 LL copy