Loading...
HomeMy WebLinkAboutPROJECT INFORMATION2431 SE Dixie Hwy SCANNED Stuart, FL 34996 W B,, Phone: (772) 287-0526 MATHERS ENGINEERING St. Email: mathersengineers@bellsouth.net CORPORATION Lucie County Memo PXCE/ED To: Plan Reviewer From: Holly Mathers AVg 0 2019 Co: St Lucie Co. Building Dept. Pages: SEE ATTACHED Pe St. oepartm Lucie coun ' tY 2300 Virginia Avenue Fort Pierce, FL 34982 Fax: Date: 08/19/2019 Re: Oceandse Condominium Phone: 10310 S. Ocean Drive, Jensen Beach Concrete Restoration Permit #SLC 1906-0221 ❑ Please Reply X Mailed ❑ Hand Delivered ❑ Faxed Only ❑ Faxed and Mailed Enclosed is 1 signed and sealed engineer's field observation report #1 for the concrete restoration permit #SLC 1906-0221 for Oceanrise Condonimium. Thank you, Holly, �..`- i This message is intended only for use of the individual or entity to which it is addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of the message is not the intended recipient, or the employee or agent responsible for delivering the message, you are hereby notified that any dissemination, distribution or copying of the communication is strictly prohibited. If you have received this communication in error, please notify us immediately by telephone and return the original message to us at the address above via the U.S. Postal Service. 2431 SE Dixie Highway Stuart. FL 34996 MATHERS ENGINEERING Phone: (772) 287-0525 CORPORATION EB#0004456 Post -Building Permit Addendum Engineer's Field Observations Report #1 Date: August 19, 2019 To: Plan Reviewer St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Referenced Project: Concrete Restoration for Common Walkways and Exterior Balconies (decks, beams & columns) For Units Numbers for Stack 7 (107, 207, 307, 407, 507, 607 and 707) for Oceanrise Condominium Located at 10310 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: DMF Construction 312 S. Old Dixie Hwy. Jupiter, FL 33458 Permit #SLC 1906-0221 Mathers Engineering Corporation visited the job site and made the following observations of the on going concrete restoration and repairs of exterior balconies: Stack #7 Balconies: • Unit 107: Chipping is underway for concrete deck and column and wall repairs. • Unit 207: Chipping is underway for concrete deck and column and wall repairs. • Unit 307: Chipping is underway for concrete deck and column and wall repairs. • Unit 407: Chipping is underway for concrete deck'and column and wall repairs. • Unit 507: Chipping is underway for concrete -deck and column and wall repairs. iy • Unit 607: Chipping is underway for concrete deck and column and wall repairs. 1 T, t_vn_Q7' Q - ,�v fc�Lcgncrete deck: and columz''and wall repairs.. _ Limitations: Our professional services have been performed, our findings obtained and our opinions prepared in accordance with general accepted engineering principles and practices. This company is not responsible for the conclusions, opinions or recommendations made by others based on our findings. \�Xkj IIIII////I Approved by, \�\� \pM I: MqT Z •'�� ,EN SF i _ PE 19658 ' N 0 �%TATE OF ..t0R10P•'���� William J. Mathers, PE Florida License #19658 Special Inspector FL License #SI-155 MATHERS ENGINEERING CORPORATION Memo c OCl.9' �Fo t�aP oPc 7pip a CP e,�OP 24z,, �E Dixie Hwy Stuart, FL 34996 Phone: (772) 287-0525 Email: mathersengineers@bellsouth.net To: Plan Reviewer From: Holly Mathers Co: St Lucie Co. Building Dept. Pages: SEE ATTACHED 2300 Virginia Avenue Fort Pierce, FL 34982 Fax: Date: 10/03/2019 Re: Oceandse Condominium Phone: 10310 S. Ocean Drive, Jensen Beach Concrete Restoration Permit #SLC 1 ❑ Please Reply X Mailed ❑ Hand Delivered ❑ Faxed Only ❑ Faxed and Mailed Enclosed is 1 signed and sealed engineer's field observation report #2 for the concrete restoration permit #SLC 1906-0221 for Oceanrise Condonimium. Thank you, Holly This message is intended only for use of the individual or entity to which it is addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of the message is not the intended recipient, or the employee or agent responsible for delivering the message, you are hereby notified that any dissemination, distribution or copying of the communication is strictly prohibited. If you have received this communication in error, please notify us immediately by telephone and return the original message to us at the address above via the U.S. Postal Service. Or B 2431 SE Dixie Highway �1p Stuart, FL 34996 MATHERS ENGINEERING CG% On 9 Phone: (772) 287-0525 CORPORATION °o���P'f EB#0004456 Post -Building Permit Addendum Engineer's Field Observations Report #2 Date: October 03, 2019 To: Plan Reviewer St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Referenced Project: Concrete Restoration for Common Walkways and Exterior Balconies (decks, beams & columns) For Units Numbers for Stack 7 (107, 207, 307, 407, 507, 607 and 707) for Oceanrise Condominium Located at 10310 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: DMF Construction 312 S. Old Dixie Hwy. Jupiter, FL 33458 Permit #SLC 1906-0221 Mathers Engineering Corporation visited the job site and made the following observations of the on going concrete restoration and repairs of exterior balconies: Stack 97 Balconies: • Unit 107: Concrete deck repairs have been completed. Guardrails and shutters reinstalled. All work on this unit is completed. • Unit 207: Concrete deck repairs have been completed. Guardrails and shutters reinstalled. All work on this unit is completed. • Unit 307: Concrete deck repairs have been completed. Guardrails and shutters reinstalled. All work on this unit is completed. • Unit 407: Concrete deck repairs have been completed. Guardrails and shutters reinstalled. All work on this unit is completed. • Unit 507: Concrete deck repairs have been completed. Waiting on installation of impact glass sliding doors by owner. • Unit 607: Concrete deck repairs have been completed. Guardrails and shutters reinstalled. All work on this unit is completed. • Unit 707: Concrete deck repairs have been completed. Guardrails and shutters reinstalled. All work on this unit is completed. MATHERS ENGINEERING CORPORATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#0004456 Limitations: Our professional services have been performed, our findings obtained and our opinions prepared in accordance with general accepted engineering principles and practices. This company is not responsible for the conclusions, opinions or recommendations made by others based on our findings. Approved by, MqT Z/i�i tP Williams Ebo Florida Lie Special Inspe'6fArIR i��#SI-155 r- /� 2431SEDixie Highway we S !� 1/ivart, FL 34996 WWII \\ /t Phone: (772) 287-0525 MATHERS ENGINEERING E13#0004456 CORPORATION FINAL CLOSE-OUT ON RESTORATION WORK Date: January 15, 2019 To: St. Lucie County Building Department SCANNED 2300 Virginia Avenue St. Lucie County Fort Pierce, FL 34982 11t Referenced Project: Concrete Restoration for Common Walkways and Exterior Balconies (decks, beams & columns) For Units Numbers for Stack 7 (107, 207, 307, 407, 507, 607 and 707) for Oceanrise Condominium Located at 10310 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: DAIF Construction 312 S. Old Dixie Hwy. Jupiter, FL 33458 Permit #SLC 1906-0221 The completed concrete restoration did not reduce the structural integrity of the remaining existing structural systems and, therefore,,a requirement to upgrade them by this permit was not warranted. Existing building's components and elements outside the renovation area of this permit do not have their current wind load resistant capacity or gravity load capacity compromised by the completed concrete. restoration. Mathers Engineering Corporation performed onsite inspections as the job progressed. Repairs did not require shoring. As the demolition exposed areas of exterior concrete deterioration and steel corrosion of the exterior. balcony deck, we initiated and inspected restoration work such as concrete applications. The enclos6d Record Drawing (Sheet #1) shows the areas of repair for Stack 7, and is made part of this final close lout document approval under Permit Number SLC 1906-0221. Materials used and work performed to date has been substantially completed in conformance with the specifications outlined in the IRCI Guideline No. 03730, as well as the applicable 2017 Florida Building Codes 6' Edition (and updates), other industry guidelines, or standard engineering practices. Approved by, 3.IM,47 �11 1 yC� i +,;:fE N19658 STATE OF ' Q WilliamJ. Mathers, PE �iSlzlftl O' . FCORI9P•` / Florida License #19658 S/ONALSpecial Inspector FL License 111110 1I � Oceanrise Condominium Association 1 10310 S. Ocean Dr. #105 Jensen Beach, FL 34957 St. Lucie County Building Department 21 SW Port St Lucie Blvd Port St. Lucie, FL 34984 June 27, 2019 RE: Oceanrise Condominium Association Inc. Dear Sir or Madame: Please allow this letter to serve as notice that Mathers Engineering is to perform the threshold inspections for the concrete restoration project to be completed at Oceanrise Condominium Association. The Board ofDirectors understand that the Association is responsible forpayment of the Threshold Engineer for his services during this project. Should you have any questions regarding this matter please contact me at 772-807-5215 or Tracy.laurett@fsresidential.com Sincerely, Tracy Laurett LCAM On Behalf of the Board of Directors Oceanrise Condominium Association Inc. SCANNED BY St. Lucie County 106_ OGZ REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 4001 MATHERS ENGINEERING CORPORAT/ON 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#004456 PRE -BUILDING PERMIT ADDENDUM SCANNED Date: May 30, 2019 SfBY . Lucie County To: St: Lucie County Building Departmenf 2300 VirgA inia Avenue'- Fort Pierce, FL 34982; Referenced project: Concrete Restoration for Common Walkways and Exterior Balconies (decks, beams & ;columns) For UnitNumbers for Stack 7 (107, 207, 307, 407, 507, 607 and 707) for Oceanrise Condominium Located at,10310 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: DMF'Constrdcfion - 312 S. Old Dixie Hwy. Jupiter, FL 33458 Background: The removal and restoration of deteriorated concrete and steel within beams, columns, decks and adjacent walls will comply with the IRCI Guideline No. 03730 (a copy of which is attached hereto) or as modified by Engineer as work progresses. The anticipated work involves the initial demolition, and then the removal, replacement and restoration of concrete and reinforcement as required. The degree of restoration is currently unknown, until such time as the initial demolition has begun. The anticipated sequence of repairs is as follows: • Shoring required for repairs of all columns, beams and decks (if required by engineer) • Removal and restoration of concrete and reinforcement steel within beams, columns and decks. (ICRI Guideline No. 03730) • Minor chipping and patching of areas not requiring full depth repairs. o Applied deck coating. The following materials are approved for anticipated use in this restoration (see attached manufacturers specifications): • Sikacrete211 Concrete Mix. REVIEWED FOR • SikaQuick 1000. E COMPLIANCE • Sika Armatec 110 EpoCem bonding agent and rebar L� ��++R • Sika FerroGard 903. ' ' ST. LUCIE COUNTY • Sikagard701W. EOCC • SikaTop 123 Plus • TREMCO Vulkem@350NF O MATHERS'ENGINEERING CORPORATION The above sequence is general.ir nature;ai Observations of the initial demolition"will procedures and materials selected for the f Based on initial -visual observations, repau demolition work reveals that shoring will .l shore the area as well as the number of lei be submitted to the Buildmgl)epartmeni 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#004456 id will be modified as restoration work -progresses. determine any required modifications to the above Trial restoration.proeess. 's will not require shoring; however, in the event the .)e_required,:the engineer will instruct the contractor to. els required. The instructions given•to the contractor will vith the final.clbse-out documents. We have been authorized by: the Association to'work with the contractor during the restoration and, Will inspect work 'partially completed as':well.as observe results. of the new demolition prior to field authorizing the repairs to be,complete'd; The proposed concrete restoration wor. except as authorized by the engineer's modified instructions, will comply: with specifications outlined in the IRCI Guideline No. 03730, as well as the applicable m;nimum building codes and the applicable fire safety standards as determined by the local authority in accordance with.Chapter 553 and Chapter 633 of the Florida Statutes where applicable to concrete restoration., Approved, G M� \ 9658ZZ �N D p�jTE, OF �j,� RIOP•'����� WilliamJ. Mathers, PE ONALENG����\ Florida License #19658 /01/1111111\\ Special Inspector FL License #SI-155 MATHERS ENGIIIIEERING CORPORATION Date: To: Refere nced It and 'kUeCKS,: Deams;,&; columns For-Units,.:Nimibijes,for Sfack7 (107,207,307,407, PrO&anriseCim&minium Located at 10310'S. Ocean Drive, Jensen Beach, FL Contrador: DMF Construction 312 S. Old Dixie Hwy. Jupiter, FL 33458 Enclose:d is a 'copy of the structural'threshold license for William J. Mathers, I inspector for the project referenced. above, in accordance with Florida Statutes, Approved, CEIV ..9658 ATE OF 40 William J. MatPE tORIVP� Z� --------- Florida Licens el hers # 6658 // - NAL Special Inspector FL License #SI-,155 or 10/1111111\0 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 E13#0o4456 Balconies 607 and 707) as the threshold .79.