HomeMy WebLinkAboutINSPECTION CARDPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fax:(772)462-6443
Permit#
SLC-1906-0398
Issued:
9/12/2019
Job Location:
3847 Us Hwy 1
Jurisdiction:
SAINT LUCIE COUNTY
Subdivision:
Flood:
X
Set backs:
Left:
Inspection�C
Permit # : 1906-(
Online address:
Permit Status Looki
Online Building Inspection
St. 4Uc e ),
County
Confirmation 186 Status EXP
M
Type: COMMERCIAL RENOVATION
City: Fort Pierce
Parcel: 1421-323-0002-000/2
Lot: Block:
Elev: Flood Map: SSG
Right: Front: Rear:
1 of 2
Job Description: Code Case - After The Fact - Siding On North And South Side, Adjust 4 Windows, 1 Sliding Glass Door And
Wooden Wall.
Contractor Lloyd M Constant — Cert # 25568 Andros Roofing & Construction Llc (772) 475-4915
2706 Atlantic Ave Fort Pierce, FL 34947
Property Owner Ft. Pierce Driving Range Prop (772) 467-2566
6460 Nw 62Nd Terr Parkland, FL 33067
Tenant J.R. Siwirki Jr
3847 N Us Hwy 1 Fort Pierce, FL 34947
SUB -PERMITS
Perm it No Status Permit Tvne Cert # DBA Owner/Builder
Go to httwilcodeinspectionoubiic stlucieco oov to schedule online. For the Automated inspection system call (866) 284-1280.
All inspections requested prior to 9:00 PM will be scheduled for the next business day. Inspection requests between 9:00 PM
Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you require any assistance please contact the
Building Department at (772) 462-1574. YOU ARE REQUIRED TO REQUEST INSPECTIONS IN THE ORDER
THEY ARE LISTED BELOW UNDER DESCRIPTION.
Inspection Notes:
Permit # Code Description Priority Sched. Date Res Description Insnector Insp. Date
1906-0398 900 PLAN REVISION 0 12118/2019 90 Approved Dave Johnson 12/182019
REVISED FENCE DETAIL TO LOCATE SUPPORT POSTS ON INSIDE OF FENCE. IMPACT PROTECTION CHANGED TO PLYWOOD PANELS FOR
WINDOWS AND NOA 18-1114.03 FOR SGD
WINDOW/DOOR //� Cancelled by
1906-0398 148 ATTACHMENT 1 9/27/2019 V 75 Contractcr/Gusto Dave Johnson
mer
1906-0398 148 WINDOW/DOOR 1 10/9/20190 81 Disapproved Dave Johnson 10/102019
ATTACHMENT
Job description needs to be revised to reflect 4 windows replaced. Stickers removed from windows. The only sticker on window indicate the windows are
Silvedine. Product approval that was submitted is for CGI vdndows. SGD Had no stickers on them & no product approval for SGD. Product approval in permit
package is for Masonite swing door. Job description does not include a swing door.Engineer approval may be required for window installation
Report prepared on 5/6/2021 9:19:16 AM
Planning& Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fax:(772)452.6443
1906-0398 148 WINDOW/DOOR
ATTACHMENT
Inspection Card
Permit # : 1906-0398
Online address:
hftp://www.stludeco.org/planning/permftting.htm
Quick Links:
Permit Status Lookup
Online Building Inspection System
REINSPECTION. No access to inspect windows/doors 110.5 FBC
1906-0398 148 WINDOW/DOOR
ATTACHMENT
1/29/202081 Disapproved Dave Johnson
8121/2020 81 Disapproved Dave Johnson
1/29/2020
8121/2020
REINSPECTION.
No access to inside to properly inspect windows/doors. Windows do not appear to be installed per manufacturers specifications from exterior only inspection.
Not able to inspect SGD do to no access to inside.
1906-0398 148 WINDOW/DOOR
ATTACHMENT
REINSPECTION.
1906-0398 187 REVISION PICKED UP
PICKED UP BY SHENIQUA MINNS-A HUMPHREY
1906-0398 999 FINAL INSPECTION
12/1812019 92 Accepted as Office
noted
Cancelled by
9127/2019 (2) 75 Contractor/Custo Dave Johnson
mer
12/18/2019
Cancelled by
1906-0398 999 FINAL INSPECTION 1 1013/2019 75 ContrectodCusto Dave Johnson 10/3/2019
mer
1906-0398 999 FINAL INSPECTION 1 10/14/2019 81 Disapproved Dave Johnson 10114/2019
1)A COMPLETE SET OF APPROVED PERMIT PLANS MUST BE ON SITE FOR INSPECTION. WHAT WAS ON SITE DID NOT MATCH WITH WHAT
WAS APPROVED.
2) APPROVED PLANS INDICATE SIX (6)WINDOWS WERE REPLACED. NEW WINDOWS REQUIRE IMPACT PROTECTION. PRODUCT APPROVAL
SUBMITTED FOR IMPACT PROTECTION MUST BE CORRECTED WITH A CURRENT PRODUCT APPROVAL IN THE FORM OF A REVISION TO
PLANS.
3) WOODEN WALL MUST BE CONSTRUCTED PER FENCE DETAIL ON APPROVED PLANS.
4) JOB DESCRIPTION MUST BE CORRECTED TO STATE WINDOW REPLACEMENT WITH IMPACT PROTECTION INSTEAD OF ADJUST FOUR
(4)WINDOWS. AND INSTALLATION OF TWO (2) SWING DOORS.
5) REVSION FOR HURRICANE BUTTERS. PRODUCT APPROVAL FOR STORM SHUTTERS IS OUTDATED.
6) EXTERIOR WALL MUST HAVE A WEATHER RESISTANT EXTERIOR WALLENVELOPE. 1403.2 FBC
1906-0398 999 FINAL INSPECTION 1 1/1312020 91 Partial Approval Dave Johnson 1/1312020
REINSPECTION. Engineers approval required for this project: wood wall, wall repairs, windows, doors, shutters.
Disapproved-
1906-0398 999 FINAL INSPECTION 1 1129121210
82 Reinspect Fee Dave Johnson 1/2912020
Required
Siding not screwed per plans (plan spec's 2 3/4" screws or 10 D nails). Screws must be 6" OC on edges and 12" OC in field. Screws must be in heavy part of
siding into solid framing. Siding not properly lapped in places. Storm panels installed do not match product approval. 4x4 posts not attached to 2x4 according to
plans. Gap between 4x4 & 2x4 does not provide for proper embedment of fastener. Need to see what the 3" pipe exiting exl. wall on south side is. This pipe may
require proper termination and cover. 107.4 FBC
1906-0398 999 FINAL INSPECTION
Disapproved-
821/2020 82 Reinspect Fee Dave Johnson 8/21/2020
Required
REINSPECTION.
See all notes from previous inspections. Siding still does not appear to be attached to structural members. Siding s611 not installed correctly in places not
correctly lapped ( see previous notes). Plywood around replaced windows needs to be replaced with siding that provides a weather resistant barrier. All replaced
siding that is delaminating or compromised from weather exposure needs to be replaced. Storm shutter over SGD is does not match with the product approval
submitted, once corrected bottom track should be attached to structure of building not detached wooden deck.
1906-0398 999 FINALINSPECTION
REINSPECTION.
Total Inspections: 14
Report prepared on 5/6/2021 9:19:16 AM