DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
ECO Windows Systems, LLC
9114 N. W.106'" Street,
Medley, FL 33178
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this
acceptance; if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series "750" Aluminum Sliding Glass Door w/ Reinforcements-L.M.I.
APPROVAL DOCUMENT: Drawing No. 18-20D, titled "Series- 750 Alum Sliding. Glass Door (L.M.I.)", sheets
1 through 8 of 8, prepared by Al-Farooq Corporation, dated 01/18/18, signed and sealed by Javad Ahmad, P.E.,
bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and
approval date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
Limitations:
1. Exterior (positive) design pressures are limited to +70 PSF w / 2-3/4" sill riser and +47.0 PSF w/ 2" sill riser.
Doors with 1" sill heights are not approved for water infiltration resistance.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and
following statement: "Miami -Dade County Product Control Approved", noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displaye_,d then it shall be
done in its entirety. ® Fayti
INSPECTION: A copy of this entire NOA sball be provided to the use MaW(
(rltors and
shall be available for inspection at the job site at the request of the 1311 ' "QThis NOA consists of this page 1 and evidence page E-1, aswell as WU) a acfLie �m ►A
The submitted documentation was reviewed by Sifang Zhao, P.E. ST . t . 000
s Z NOA No.18-0129.09
MIAMFnnoECOUNTY Expiration Date: May 30, 2024
OS�30 f ZOl C% Approval Date: May 30, 2019
FILE ,COPY Page 1
ECO Windows Systems, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBNIITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. 18-20D, titled "Series-750 Alum Sliding Glass Door (S.M.I.)", sheets 1
through 8 of 8, prepared by Al-Farooq Corporation, dated 01/18/18, signed and sealed by
Javad Ahmad, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Small Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagrams of Alum sliding Glass doors,
prepared by Fenestration Testing Lab, Inc., Test Report No. FTL-9831 dated 12/08/2017,
signed and sealed by Idalmis Ortega, P. E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-2017 (61h
Edition), prepared by Al Farooq Corporation, dated 01/09/18, signed and sealed by Javad
Ahmad, P.E.
2. Glazing complies w/ ASTME-1300-09.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc for "1'rosifol": Ultra
clear, clear & color PVB glass interlayer, expiring on 07/08/24.
F. STATEMENTS
1. Statement letter of conformance to FBC 2017(61 edition) prepared by Al-Farooq
Corporation, dated January 09, 2018, signed and sealed by Javad Ahmad, P.E.
2. Lab compliance as part of the above referenced test report.
G. OTHER
1. Test proposal #17-0580, dated 06/13/17 approved by Ishaq Chanda, P.E.
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 18-0129.09
Expiration Date: May 30, 2024
Approval Date: May 30, 2019
E-1