Loading...
HomeMy WebLinkAboutMISC LETTERRECEIVED Chief Building Official July 2, 2019 St Lucie County Building Department JUL 0 2 2019 2300 Virginia Avenue ST. Lucie county, Permitting Ft Pierce, FL 34982 Reference: Nettles Island HOA Bath House #5 9801 S Ocean Drive SCB�NFD Jensen Beach, FL 34957 St. Cu% CoUnfy Subject: New Roof Material — Pool Building The roofer may install Dynamic Metals 1" nail strip, 0.032aluminum panels on the existing one story pool bldg. per the attached FL- 21082-R2 Florida Test Report. #10X1" pancake head fasteners, spaced @ 6" from each end and 6" o/c/ field are to be installed in all zones. The required applied uplifts in their appropriate zones for a mean roof height of < 15 feet, in exposure "D" during a 170 mph it,132 mph asd wind event are as follows: Zone #1 (45 psf) Zone #2 (-75 psf) Zone #3 (413 psf) The product, installed per the aforementioned pattern / spacing, has been tested to provide a maximum total uplift design pressure of 168.5 psf psf, clearly exceeding the requirements for all three zones If you have any questions, please call me at your convenience. Dr. Ernest A. Kuonen, PE 022920 President, The Erning Corporation CA-8327 228 Moccasin Trail West Jupiter, FL 33458 IIOq —004- SEVIVWED F R CODE COMPLIANCE S-r. LU BOCC C FILE COPY