Loading...
HomeMy WebLinkAboutPLANr I LI U i'v Q u OMNOING THE WOXIO National Headquarters: 1077 West Blue Heron Blvd. West Palm Beach, Florida 33404 800.772.7932 www.atlasbtw.com SCANNED BY St. Lucie County Cumberland F A R ii101 S 1020 Shorewinds Drive Fort Pierce, Florida SCANNED BY St. Lucie County © Existing b/F pylon to to be removed and not replaced ® Existing S/F Wall Sign to receive (1) new pan -formed face replacement ® New S/F LED Price Board New S/F LED Price Board REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC I urawiny Nunivar. 24' 9 1 /2" � 11' `3 ; 00 REGOLAR4L NnartPaYMEMeFR� M C i Cumberland One 2' 4" x 11' LED Price Board on this elevation of canopy. *Pricer to be provided by client. 4'-8" Sign Face 6'-3 7/8" Sign Face 4" 4'-0" Logo B" °• .•' • REGULAR N L SmartPay MEM Cumberland F A. R M S Front Elevation 3 314" Z2 1/2" 11 2" L Side Elevation REVIEWED FOR CODE COMPLIANCE STD L,UCIE COUNT` sIAAAi National Headquarters: 1077 West Blue Heron Blvd West Palm Beach, Florida 33404 ri tiasaoo.772.7932 BRANDING THE WORLD www.atlasbtw.com Revisions: T C 0 n PM: SC Address: 1020 Sliorewinds Drive Revised iayoutoa.u.zois no Drawn By: MB City State: Fort Pierce, FL Date: 02/14/2019 Drawing Number: 97665-SO4 56' CABINET DAL 48' LOGO - CID I D1 3" 1� o (O Z O o -- ` c Do a N O c Uv m � N „ va POWER HOLE CUT IN FIELD LWHERE $ NOTCH ATALL OUTER SIDE PANELS m r+- FOR DISCONNECT SWITCH CLEARANCE NOTE: LEFT DISCONNECT SWITCH FOR LEDs) Z'> Do DoFront Elevation Scale: 1" = 1' (DI)Side Section - Logo Cabinet Scale: 1" = V 25" C TO C fma OVERALL LENGTH BOTH CABINETS 118° BETWEEN CABINETS 3" 23 5116' C TO 75 7/8' 3/4" ACRYLIC PUSH-THRU (6.323') -- 1ST SURFACE VINYL TEXT POWER HOLES FOR POWER JUMPS TO JOIN WITH CONDUIT AT REAR OF CABINETS TO PUSH-THRU LEDs. (NOTE: POWER JUMPSIHOLES INSTALLED ON SITE AT INSTALL) 3/8' DIAALL-THREAD 304 SS STEEL RODS THROUGH BACK OF CABINET AND CANOPY FACE AND FRAMEWORK TO UNISTRUTAT REAR. FASTENED WITH SS NUTS AND WASHERS. 2°H x 1/2' DEEP ALUM. U-CHANNEL STIFFENER BRACKETS AT MOUNTING LOCATIONS ATTACHED TO CABINET BACK PANELS. (D2)Side Section - Pricer Cabinet Scale: 1" =1' BRAKE FORMED ALUM. BACKER CABINET STRUCTURE (.06T) 118'ACM ALUMINUM BRAKE FORMED HII CABINET FACE W/ RETURNS CABINETS LED PRICE CHANGE BOARDS (SUPPLIED BY CUSTOMER) DISCONNECT SWITCH / POWERSUPPLY(IES) FOR LED NOTE: RIGHT DISCONNECT SWITCH FOR LED PRICE ( O1 EXISTING CANOPY STRUCTUREIBRACING. O2 PRIMARY ELECTRIC 120/277V(BYOTHERS) (DDECORATIVE MOLDING (BY OTHERS)APPROX ST. O PIANO HINGE ALONG TOP OF FACES O5 #10.16 TEK SCREWS, MIN (3) TOP &BOTTOM, MIN. (6) TOTAL (MIN CANOPY THICKNESS 0.060') © 0.125' BOLTEDALUMIACM FACE HINGED AT TOP FOR ACCESS TO INTERNAL SIGN COMPONENTS. 0 314°THICK CLEAR ACRYLIC PUSH-THRU LOGO & COPY W/TRANSLUCENT VINYLAPPLIED 1ST SURFACE O 0.063°ALUMINUM BACKER O9 SLOAN WHITE VL PLUS 2 LONG LED MODULES @ 6500K 70 SLOAN 12012T7V POWER SUPPLY 11 2112'DEEP x 3' TALL CUTOUT ON ALL OUTER SIDE RETURNS TO ALLOW PANEL TO CLOSE OVER DISCONNECT SWITCH AND POWER JUMP BETWEEN CABINETS AS WELL ON ALL CABINET SIDES EXCEPT FOR THE RIGHT SIDE OF THE PRICE COUNTER CABINET. 12 SIGN ATTACHED TO CANOPY STRUCTURE WI 30 DIA. 304 SS ALLTHREAD AND BOLTED TO UNISTRUT AT REAR OF CANOPY STRUCTURE. (SEE DRAWING ABOVE FOR CITY AND LOCATION OF MOUNTING POINTS) Cumberland Farms, Fort Pierce, Florida 07.02.19 ID & price cabinets on the gasoline canopy (East Exposure) Wind Load per FBC 6" Edition, 2017; ASCE 7-10; Exposure D VuLT = 161 mph (FBC Fig. 1609.3(1) - County Map); Risk Category II VA,o = V"cT x (Ill = 125 mph (FBC Table 1609.3.1) ASCE Chapter 30, Part 1, components and cladding Gasoline canopy mounted signs. Wall zone 5; roof height < 20 ; K„ =1.08 (Table 26.10-1) K„ -- 1; K, = 0.85 (Table 26.6-1) p = qT (GC)A (Eq. 29.3-1) (GC P) _ -1.4 (away from wall) (Fig. 30.3-1) Note: (G,Cp) = 0 (Sec 29.3.2); A„ < 10 sf q, = 0.00256 x 0.85 x 1.08 x (125)'= 36.72 psf (Eq. 26.10-1) p = 36.72 psf x -1.4 = 51.4 psf acting as pullout ID cabinet: A = 4.667' x 2.771' = 12.93 sf per attachment (6): A' = 12.93 / 6 = 2.16 Price cabinet: A = 6.323' x 2.771' = 17.53 sf Per attachment (8): A' = 17.53 sf 18 = 2.19 (critical loading) Cabinet attachments to canopy wall: (8) 3/8" threaded SS rods 318" dia. threaded steel rods; Am = 0.0775 sq.in. PA = 30 ksi x 0.0775 in' = 2,325# / rod Sign geometry is such that bottom row of (4) rods takes 63% of load. P= 17.52 sf x.51.4 psf = 901# x 63% = 567# NumNoteb�C� A 1 grants to) the panel are OK CODE COMPLIANCE ST. LUCIE NOTE: VERIFY POWER SUPPLY'SA AMPS/CIRCUITS FOR LED'S NEEDED BEFORE PRODUCTION Dedicated M4 atedals and fasteners meet 3004.4 9. electrical components are UL listed and approved. 3. Sign grounded according to NEC600.7. 4. Signs manufactured and listed NEC 6DO.3 and marked per NEC 600.4. 5. Al branch circuits per NEC 600.5(B).1 or (B).2. 6. All Signs corbelled by photocell or time clock per NEC 2017, FBC 2017. 6th Edition. 7. One visible 20 amp disconnect per sign per circuit per NEC 600.6(A).1 8. All Class 2 rated LED modules and LED power supplies will be in compliance with a nationally recognized test laboratory. atlas BRANDING THE WORLD Headquarters 1077 West Blue Heron BNd, West Palm Beach, FL 3 04 Northeast Division 707 Commerce Dr. Concord, NC 28D25 Western Division 1585 Hlgh Meadows We, Cedar Hills, Tx 75104 1-B00-772-7932 wwvvstlasblw.c:m PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLE PROPERTY OF ATLAS SIGN INDUSTRIES. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF ATLAS SIGN INDUSTRIES IS PROHIBITED. TITLE CUMBERLAND FARMS 28"H LED PRICE BOARD CABINETS (CANOPY MOUNT) ADDRESS 1020 SHOREWINDS DRIVE FORT PIERCE, FL 34949 DRAWING NENG-97665-SO4 REV.# 1 OF 1 NAME DATE DRAWN BY SHAWN G. 06/26/2019 PROJECT NOR. M. GARCIA Code Provisions for Sign Installation: Florida Building Code V Edition: 2017 Wind load perASCE7-10; FBC sections 1609.1.1; 1620; Exposure D; Risk Category 11 V„T = 161 mph (FigA 609.3(1) - County Map) ENGINEER INFORMATION NAME: Theodore M. McAnlis, P.E. ADDRESS: P.O. Box 14724 North Palm Beach, Florida 33408 E-MAIL: mcanlis.engr@gmail.com LICENSE: FL 19239 As witnessed by my seal, I certify that the sign or letter attachments meet or exceed the requirements of the 2017 FBC for wind speed, Vu, = 161 mph. \VIIIII IIII/II' .`` FtE M. 4, i No 19239 `N =_ «*Q1GGilJS• 07. d 3. I ¢ Qom` �)30 STATE OF FCORIOP..•'G�\