HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM t� S160 N.W. Milner Drive Port Saint Lucie, FL 34983 a Telephone:772-621-3322 OISs" Fax: 772-621-3604 Web Address: www.sidd.com Building Dept. FMOPermit# B-19-222 Project Name Dunkin Donuts ,. BLDG Permit# 1907-0231 Address 903 East Pima Vista.. Blvd _ ` city PSL Contractor Commercial Contracting Div Address 709 SE 5 Street v city Stuart .State Florida .Zip I34994 Telephone (772)260-2450 ArchitectlEngineer Atlantic Engineering Services Telephone (904) 743:4633 Occupancy Type Business Construction Type VB Square Feet 2967 Occupant Load 49 per plans Numberof Stories--- Access Box AFS Permit I FA Permit. General Notes ' Access Key Switch I FFPPermit Required II 1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be.pdf only. 2'. All revisions; including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. S. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. B. Plans and construction are subjectto corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC systemis that exceed 2,000 cfm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed. Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2015 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. The Installation or a Fixed Fire Protection Systems require a separate review and permit. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and spect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector. portable fire extinguishers from a licensed contractor are required. Page 11.of 11 Reviewed by Tony Jerger Date 07-18-2019